| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET 02II |
| Standards Compliance | ISO 1432, ASTM D1053 |
| Test Stations | 6 independent automated stations |
| Temperature Control | Computer-regulated ramp (–70 °C to +100 °C, optional LN₂ cooling) |
| Output Parameters | RM2, RM5, RM10, RM100 torsional rigidity indices |
| Data Presentation | Real-time graphical curves + tabular export |
| Software | Windows-based control & analysis suite with audit trail capability |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET 05II |
| Compliance Standards | ISO 812, ISO 974, ASTM D746, ASTM D2137 |
| Operating Pressure | 6 bar compressed air required |
| Test Principle | Instrumented drop-weight impact with controlled thermal conditioning |
| Temperature Control | Computer-regulated cryogenic chamber (–70 °C to +50 °C typical range) |
| Impact Velocity Measurement | High-speed optical sensor with pre- and post-impact velocity verification |
| Energy Delivery | Adjustable via drop height and calibrated hammer mass |
| Software | Windows-based control & analysis suite with audit trail and report generation |
| Brand | Engelsmann |
|---|---|
| Origin | Germany |
| Model | STAV II Tap Density Tester |
| Instrument Type | Bulk Density Tester |
| Portability | Benchtop (not portable) |
| Sample Form | Powders, Granules, Fibers |
| Compliance | DIN ISO 787-11, ISO 3953, ASTM B527-93 |
| Cylinder Options | 10–1000 mL (standard set: 10, 25, 50, 100, 250, 500, 1000 mL) |
| Tapping Frequency | 250 rpm ±15 rpm |
| Stroke Amplitude | 3.0 mm ±0.1 mm |
| Maximum Sample Mass | 670 g ±45 g |
| Mass Resolution | 0.001 g |
| Operating Temperature | Ambient (15–30 °C recommended) |
| Minimum Sample Volume | 10 mL |
| Power Supply | Single-phase AC, 50 W |
| Noise Level | 80 dB (unshielded), 58 dB (with acoustic damping viewport) |
| Dimensions (W×D×H) | 290 × 330 × 180 mm |
| Net Weight | 9 kg |
| Brand | Engelsmann |
|---|---|
| Origin | Germany |
| Model | KDM01 |
| Instrument Type | Laboratory Benchtop Tap Density Analyzer |
| Measurement Principle | Mechanical Vibration-Based Volume Reduction (DIN ISO 3953 Compliant) |
| Sample Tube Capacity | 25 mL and 100 mL |
| Vibration Frequencies | 100 / 200 / 300 Hz |
| Amplitude | 3 mm |
| Dimensions (L×W×H) | 390 × 380 × 270 mm |
| Net Weight | 17 kg |
| Power Rating | 55 W |
| Voltage | 110/220 V AC |
| Minimum Sample Volume | 10 mL |
| Density Resolution | 0.001 g/cm³ |
| Operating Temperature | Ambient (15–30 °C) |
| Compliance | DIN ISO 3953, ASTM D4781, USP <616>, EP 2.9.34 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Bulk Density & Flow Tester |
| Instrument Type | Portable |
| Measurement Type | Solid Powder |
| Application | Metal powder flowability and apparent density testing |
| Standards Compliance | GB/T 1482–2010 (Hall Flow), GB/T 1479.1–2011 (Apparent Density) |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel Cone Angle | 60° |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel, 25 mm wide |
| Stopper Rod | Stainless steel 304 |
| Dimensions | Approx. 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Brand | Stable Micro Systems |
|---|---|
| Origin | United Kingdom |
| Model | TA.XT Plus C |
| Force Range | ±5 kg / ±30 kg / ±50 kg |
| Speed Range | 0.01–40 mm/s |
| Distance Resolution | 0.001 mm |
| Force Accuracy | 0.0002% of full scale |
| Test Distance Range | 0.001–295 mm |
| Operating Temperature | 0–40 °C |
| Dimensions (H×W×D) | 665 × 280 × 440 mm |
| Weight | 16.2 kg |
| Power Supply | 220 V, 50 Hz |
| Interface | RS232 or USB |
| Software | Multilingual (including English and Chinese), ASTM/ISO/AOAC-compliant method library |
| Probe Options | 300+ application-specific probes |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-B |
| Price Range | USD 11,200 – 21,000 |
| Sensor Dimensions | 460 mm × 620 mm |
| Active Sensing Area | 400 mm × 400 mm |
| Sensor Resolution | 2,288 discrete pressure points |
| Thickness | 0.2 mm |
| Maximum Load Capacity | 100 kg (≈981 N) |
| Accuracy | ±10% FS (as-received), ±5% FS (post-calibration) |
| Operating Temperature | −9 °C to +60 °C |
| Interface | USB 2.0 |
| Power Supply | Bus-powered via USB |
| Sampling Rate | 0–100 Hz |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(DK)TBRTY |
| Spindle Speed | 24,000 rpm |
| Feed Rate | 0–500 mm/min |
| Cutting Depth | 2–20 mm |
| Compatible Pipe Diameter | 50–250 mm |
| Max. Workpiece Length (Pipe/Sheet) | 260 mm |
| X-Axis Travel | 280 mm |
| Y-Axis Travel | 310 mm |
| Z-Axis Travel | 70 mm |
| Frame Material | Aluminum Alloy |
| Stepper Motor & Driver Sets | 3 |
| High-Speed Variable-Frequency Spindle Motor | 1 |
| Precision Linear Guide Rods | 6 |
| Precision Ball Screws | 3 |
| Standard Vise | 1 set |
| Tooling Options | Cylindrical end mill, 20° flat-bottom cutter, slitting blade, 45° chamfering cutter |
| Tool Diameters | Φ3 mm, Φ4 mm, Φ6 mm |
| Max. Machining Envelope | 300 × 150 × 100 mm |
| Power Supply | 220 V AC |
| Total Power Consumption | 1500 W |
| Net Weight | 45 kg |
| Brand | Guance Instruments |
|---|---|
| Model | GCZMD-10b |
| Origin | Beijing, China |
| Instrument Type | True Density Analyzer |
| Design | Portable |
| Sample Type | Solids and Liquids |
| Density Range | 0.1–20 g/cm³ |
| Maximum Sample Weight | 20 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1 g/cm³ (typical repeatability ≤0.3% RSD) |
| Measurement Principle | Gas Expansion Displacement (Helium Pycnometry) based on Boyle’s Law (PV = nRT) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Measurement Time | ~4 min per run |
| Operating Temperature | 0–40 °C |
| Pressure Range | 1.3–2.0 bar |
| Recommended Analysis Gas | Helium (N₂ compatible with calibration adjustment) |
| Data Interface | RS485, RJ45 Ethernet, USB for U-disk storage |
| Display | Touchscreen with handwriting input |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Minimum Sample Mass | 0.1 g |
| Data Output | Real-time process logging + CSV export via USB |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0.001–6000 HV |
| Total Test Forces | 10, 25, 50, 100, 200, 300, 500, 1000 gf |
| Standards Compliance | GB/T 4340.2, JJG 151 |
| Objective Lenses | 10×, 40× |
| Total Optical Magnification | 100×, 400× (digital zoom up to ~1600×) |
| X-Y Motorized Stage | 50 mm × 50 mm travel, 185 mm × 140 mm platform, 50 kg load capacity |
| Maximum Specimen Height | 180 mm |
| Indenter-to-Column Distance | 130 mm |
| Dwell Time | 0–60 s (1 s increments) |
| Illumination | Adjustable LED brightness |
| Data Acquisition | Encoded digital measurement |
| Software Interface | Multilingual (English, Chinese, German, Spanish, Russian) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 3351 |
| Pricing | Upon Request |
| Density Range | 0–2 g/cm³ |
| Accuracy Class | 0.2 or 0.5 |
| Resolution | 0.0005 g/cm³ |
| Supply Voltage | 18.5–30 V DC (nominal 24 V DC) |
| Ambient Temperature | −10 to +60 °C |
| Ambient Humidity | 5–90 % RH |
| Display | Smart LCD or LED digital indicator |
| Output Signal | 4–20 mA analog with optional HART protocol |
| Mechanical Mounting | Flanged connection |
| Installation Types | Top-mount (insertion depth 850 mm) or side-mount (insertion depth 700 mm, center-to-center tap distance 500 mm, side width 150 mm) |
| Intrinsic Safety Rating | Available (per IEC 60079-11) |
| Hygienic Design Option | Available (3-A compliant, FDA-compatible wetted materials) |
| Brand | AMAE |
|---|---|
| Model | MI-1000A |
| Origin | Guangdong, China |
| Dimensions (L×H×W) | 500 × 200 × 500 mm |
| Vibration Direction | Vertical |
| Max Load Capacity | 100 kg |
| Adjustable Peak-to-Peak Amplitude | 0–5 mm |
| Vibration Waveform | Sine |
| Frequency | 50 Hz |
| Insertion Rod Masses | 88 g and 177 g |
| Power Supply | 220 V ±10%, 5 A max |
| Environmental Requirement | Temperature- and humidity-controlled, draft-free |
| Sample Container Options | Small cylinder (1.7 L, for particles ≤10 mm) |
| Compliance | IMSBC Code Annex 1, Section 3.1.2 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERADEN X |
| Instrument Type | Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, ASTM D5002, ISO 12185, SH/T 0604 |
| Key Feature | Integrated Auto-Drying Pump, Built-in Ambient Pressure Sensor, FillingProof™ Bubble-Resistant Sampling Technology, Corrosion-Resistant Aluminum Housing, Vertical Oscillating X-U-Tube Design |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAdens X |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample State | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Repeatability | ±0.000005 g/cm³ |
| Resolution | 0.00001 g/cm³ |
| Temperature Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, SH/T 0604 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERADENS XS |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample State | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ |
| Density Resolution | 0.00005 g/cm³ |
| Temperature Range | 10–60 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D5931, ISO 12185, SH/T 0604 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #200 |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CP2000 |
| Pricing | Available Upon Request |
| Brand | ERWEKA |
|---|---|
| Origin | Germany |
| Model | SVM II |
| Instrument Type | Tap Density Tester |
| Application | Powder Bulk & Tapped Density Measurement |
| Compliance | USP <616>, EP 2.9.34, USP <1174>, ASTM B527-15, DIN EN ISO 787-11:1995 |
| Temperature Range | +10 °C to +30 °C |
| Dimensions (H×W×D) | 196.5 × 300 × 326 mm |
| Weight | 17 kg |
| Power Supply | 115/230 V, 50/60 Hz |
| Protection Class | IP21 / IEC 60529, Class I / EN 61140 |
| Test Stations | 1 or 2 (configurable via SwitchPlate system) |
| Tap Frequency & Height | USP Method 1: 300 ±15 taps/min, 14 ±2 mm |
| USP Method 2 | 250 ±15 taps/min, 3 ±0.2 mm |
| Data Storage | Last 10 test reports (local) |
| Interfaces | USB-A, USB-B, RS232, Ethernet |
| Report Export | XML/PDF via Export Manager software |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | EU501 |
| Laser Wavelength | 655 nm (red semiconductor, visible) |
| Laser Class | FDA CDRH 21 CFR Part 1040.10 Class 2 |
| Output Power | 220 μW |
| Thickness Measurement Repeatability | ±2 μm |
| Sample Volume Requirement | < 5 mL |
| Host Dimensions (mm) | W130 × D150 × H105 |
| Detector Dimensions (mm) | W120 × D165 × H180 |
| Origin | Japan |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | EyeScale-One, EyeScale-Two, EyeScale-Three, EyeScale-Four, EyeScale-4W, EyeScale-IP, Tester-21 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FID-100W |
| Pricing | Available Upon Request |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | HM2000S |
| Instrument Type | Microhardness Tester |
| Compliance | DIN EN ISO 14577 |
| Measurement Principle | Instrumented Indentation Testing (IIT) |
| Key Output Parameters | Martens Hardness (HM), Indentation Hardness (HIT), Indentation Modulus (EIT), Indentation Creep (CIT), Elastic Work Ratio (ηIT), Depth- and Load-Dependent Property Mapping via ESP Mode |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | IMVS/IMPS |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | <100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (optional ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (optional cryo-thermo stage) | −120 °C to +150 °C |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | OPV/PSC |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | < 100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V |
| Optional Modules | Multi-LED Source (360–1100 nm), Cryogenic Stage (−120 °C to +150 °C), Spectrometer Integration, SMU Extension (±60 V, 1 pA resolution) |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | PTC-TPV |
| Sampling Rate | 60 MS/s |
| Time Resolution | 18 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | < 100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V |
| Optional Modules | Solar Cell & OLED Dual Configuration, Multi-Wavelength LED Source (360–1100 nm), Cryogenic/Heated Stage (−120 °C to +150 °C), Integrated Spectrometer, SMU Extension (±60 V, 1 pA current resolution) |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | TEL |
| Key Features | DC/AC/Transient operation modes |
| Measurement Capabilities | TEL, TPC, TPV, Photo-CELIV, Dark-CELIV, IMPS, IMVS, IS, CV, C-f, DLTS, SCLC, Pulse Voltage, MIS-CELIV, Delaytime-CELIV, Injection-CELIV |
| Sampling Rate | 60 MS/s |
| Time Resolution | 18 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | <100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (extendable to ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (optional cryo/heating stage) | −120 °C to +150 °C |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | AVI800Z |
| Quotation | Upon Request |
| Laser Wavelength | 355 nm |
| Max. Average Laser Power | 15 W |
| Laser Repetition Rate | 40–120 kHz |
| Max. Processing Area | 200 mm × 270 mm |
| Overall Processing Accuracy (Zhengye Standard Conditions) | ±50 µm |
| Motor Speed | 500 mm/s |
| Motor Positioning Accuracy | ±4 µm |
| Motor Repeatability | ±2 µm |
| Laser Scanning Range | 40 mm × 40 mm |
| Host Power Supply | AC 220 V, 50 Hz / 1.5 kW |
| Dust Collector Power Supply | AC 380 V, 50 Hz / 1.5 kW |
| Weight | 1500 kg |
| Operating Temperature | 20 °C ± 2 °C |
| Relative Humidity | ≤60 % RH |
| Supported File Formats | .Gbr, .dxf |
| Dimensions (L×W×H) | 1100 mm × 1570 mm × 1700 mm |
| Cleanroom Classification | ISO Class 8 (100,000) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FUD-1 Model-12 |
| Pricing | Available Upon Request |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FLV-10ARS-F |
| Hardness Range | 0–3000 HV |
| Test Force Range | 10 gf – 10 kgf |
| Specimen Stage Travel | 180 mm × 150 mm |
| Maximum Specimen Height | 210 mm |
| Maximum Specimen Depth | 180 mm |
| Load Application | Load Cell-Based Closed-Loop Force Control |
| Optical System | Long Working Distance Objective Lens |
| Optional Imaging | 5 MP CMOS Camera |
| Software Features | Auto-Contour Mapping, Z-Axis Tilt Compensation, Programmable Test Path, Dynamic Load Switching, Custom Report Generation |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FLV-50ARS-F |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0–3000 HV |
| Total Test Force | 50 gf to 50 kgf (16 selectable steps) |
| Specimen Stage Travel | 180 mm × 150 mm |
| Maximum Specimen Height | 210 mm |
| Maximum Specimen Depth | 180 mm |
| Optical System | Long-working-distance objective lens |
| Optional Imaging | 5 MP CMOS camera |
| Compliance | ASTM E384, ISO 6507, JIS Z 2244, GB/T 4340 |