Other Physical Property Test Instruments
Filter
Showing 241–270 of 1035 results
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SPECIMEN CORING MACHINE |
| Drill Bit Internal Diameter | 21.5–63.5 mm (0.845–2.5 in) |
| Maximum Core Depth | 125 mm (5.0 in) |
| Cooling Medium | Water or Oil |
| Motor Power | 1,500 W |
| Dimensions (W×D×H) | 500 × 500 × 1800 mm |
| Weight | 150 kg |
| Power Supply | 220 V, 50–60 Hz |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SPECIMEN FLATNESS GAGE |
| Granite Base Dimensions | 200 mm × 300 mm × 50 mm |
| Max Sample Height | 300 mm (12 in) |
| Accuracy | ±0.0001 in |
| Resolution | 0.01 mm (0.0005 in) |
| Weight | 20 kg |
| Compliance | ASTM D4543 |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SPECIMEN GRINDER |
| Max Sample Diameter | 100 mm (4 in) |
| Max Sample Length | 200 mm (8 in) |
| Grinding Accuracy | ±0.001 in (±0.025 mm) |
| Grinding Wheel Diameter | 150 mm |
| Motor Power | 550 W |
| Speed | 3,000 rpm |
| Dimensions | 600 × 500 × 500 mm |
| Weight | 40 kg |
| Power Supply | 220 V, 50–60 Hz |
| Compliance | ASTM D4543 |
| Brand | FloXLab |
|---|---|
| Origin | France |
| Model | WCM |
| Sample Chamber Options | EX, AX, BX, NX, 1" Ø, 1.5" Ø |
| Drying Temperature | 150 °C |
| Drying Duration | 24 h |
| Vacuum Level | 10⁻³ mbar |
| Max Sample Weight | 2,500 g |
| Mass Resolution | 0.01 g |
| Sample Capacity | Variable (dependent on diameter) |
| Wetted Materials | ASTM A276 Type 316L Stainless Steel |
| Power Supply | 220 V/50 Hz or 110 VAC/60 Hz (configurable at order) |
| Brand | Floxlabs |
|---|---|
| Origin | France |
| Model | CAI 70 |
| Standard Compliance | ASTM D7625-10 |
| Load | 70 N |
| Max Sample Length | 150 mm |
| Max Sample Diameter | 76 mm |
| Scratch Resolution | 0.01 mm |
| Indenter Material | Steel, Rockwell Hardness HRC 54–56 |
| Weight | 25 kg |
| Dimensions (W × L × H) | 330 × 500 × 500 mm |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SPECIMEN TRIM SAW |
| Blade Diameter | 200 mm (8 in) |
| Blade Thickness | 2 mm |
| Max. Specimen Diameter | 54.7 mm (2.125 in) |
| Max. Specimen Length | 109.4 mm (4.3 in) |
| Positioning Accuracy (Dual-End Flatness) | ≤ 0.05 mm (0.002 in) |
| Motor Power | 550 W |
| Speed | 3,000 rpm |
| Coolant | Water (standard), Optional Oil-Based Coolant |
| Dimensions (W×D×H) | 700 × 800 × 600 mm |
| Weight | 60 kg |
| Power Supply | 220 V, 50–60 Hz |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | IMVS/IMPS |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | <100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (optional ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (optional cryo-thermo stage) | −120 °C to +150 °C |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | OPV/PSC |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | < 100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V |
| Optional Modules | Multi-LED Source (360–1100 nm), Cryogenic Stage (−120 °C to +150 °C), Spectrometer Integration, SMU Extension (±60 V, 1 pA resolution) |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | PTC-TPV |
| Sampling Rate | 60 MS/s |
| Time Resolution | 18 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | < 100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V |
| Optional Modules | Solar Cell & OLED Dual Configuration, Multi-Wavelength LED Source (360–1100 nm), Cryogenic/Heated Stage (−120 °C to +150 °C), Integrated Spectrometer, SMU Extension (±60 V, 1 pA current resolution) |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | TEL |
| Key Features | DC/AC/Transient operation modes |
| Measurement Capabilities | TEL, TPC, TPV, Photo-CELIV, Dark-CELIV, IMPS, IMVS, IS, CV, C-f, DLTS, SCLC, Pulse Voltage, MIS-CELIV, Delaytime-CELIV, Injection-CELIV |
| Sampling Rate | 60 MS/s |
| Time Resolution | 18 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | <100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (extendable to ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (optional cryo/heating stage) | −120 °C to +150 °C |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | AVI800Z |
| Quotation | Upon Request |
| Laser Wavelength | 355 nm |
| Max. Average Laser Power | 15 W |
| Laser Repetition Rate | 40–120 kHz |
| Max. Processing Area | 200 mm × 270 mm |
| Overall Processing Accuracy (Zhengye Standard Conditions) | ±50 µm |
| Motor Speed | 500 mm/s |
| Motor Positioning Accuracy | ±4 µm |
| Motor Repeatability | ±2 µm |
| Laser Scanning Range | 40 mm × 40 mm |
| Host Power Supply | AC 220 V, 50 Hz / 1.5 kW |
| Dust Collector Power Supply | AC 380 V, 50 Hz / 1.5 kW |
| Weight | 1500 kg |
| Operating Temperature | 20 °C ± 2 °C |
| Relative Humidity | ≤60 % RH |
| Supported File Formats | .Gbr, .dxf |
| Dimensions (L×W×H) | 1100 mm × 1570 mm × 1700 mm |
| Cleanroom Classification | ISO Class 8 (100,000) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FUD-1 Model-12 |
| Pricing | Available Upon Request |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FLV-10ARS-F |
| Hardness Range | 0–3000 HV |
| Test Force Range | 10 gf – 10 kgf |
| Specimen Stage Travel | 180 mm × 150 mm |
| Maximum Specimen Height | 210 mm |
| Maximum Specimen Depth | 180 mm |
| Load Application | Load Cell-Based Closed-Loop Force Control |
| Optical System | Long Working Distance Objective Lens |
| Optional Imaging | 5 MP CMOS Camera |
| Software Features | Auto-Contour Mapping, Z-Axis Tilt Compensation, Programmable Test Path, Dynamic Load Switching, Custom Report Generation |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FLV-50ARS-F |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0–3000 HV |
| Total Test Force | 50 gf to 50 kgf (16 selectable steps) |
| Specimen Stage Travel | 180 mm × 150 mm |
| Maximum Specimen Height | 210 mm |
| Maximum Specimen Depth | 180 mm |
| Optical System | Long-working-distance objective lens |
| Optional Imaging | 5 MP CMOS camera |
| Compliance | ASTM E384, ISO 6507, JIS Z 2244, GB/T 4340 |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM-300 |
| Hardness Scale Range | 1–5000 HV |
| Test Load | 1000 gf (9.807 N) |
| Maximum Specimen Height | 95 mm |
| Maximum Specimen Depth | 115 mm |
| Optical System | Dual Standard Objectives (10× & 50×), Expandable to Four Objectives |
| Indentation Measurement | Manual or Optional Digital XY Stage with 0.01 µm Resolution at 500× Magnification |
| Compliance | JIS B 7725, JIS B 7734, JIS B 7735, ASTM E-384, ISO 6507-2, ISO 8507-2 |
| Control Interface | FM-810 Smart Touch Panel (7″ Full-Color LCD), Supporting HV/HK/HBW/HBS/KC Toughness Testing, SAE-J417b & ASTM E140 Hardness Conversion, Cylindrical/Spherical Surface Correction, Data Logging, and GLP-Compliant Audit Trail |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM-310 |
| Hardness Tester Type | Micro-Vickers |
| Test Load Range | 1 g to 1000 g (selectable combinations) |
| Maximum Test Load | 1000 g |
| Specimen Height Clearance | 95 mm (H) × 115 mm (D) |
| Compliance | JIS B 7734, JIS B 7735, ASTM E384, ISO 6507-2 |
| Optical System | Dual-standard objective lenses (10× & 50×), expandable up to four objectives (5×, 20×, 40×, 100×) |
| Measurement Method | Manual or optional digital X-Y stage with encoder-based coordinate input |
| Indentation Evaluation | Manual measurement via eyepiece micrometer or optional AR-assisted automatic indentation recognition (1.3 MP CMOS camera + FT-ZERO software) |
| Display Interface | 7-inch full-color LCD touchscreen (FM-810 control unit) |
| Load Application | Fully automated loading–holding–unloading sequence at 60 µm/sec |
| Hold Time Range | 5–99 s |
| Focus Mechanism | Manual coarse/fine focusing |
| Turret Operation | Motorized auto-turret (FM-310/FM-810) |
| Hardness Scales Supported | HV, HK, HBW, HBS, KC fracture toughness |
| Hardness Conversion | Built-in SAE J417b and ASTM E140 lookup tables |
| Surface Correction Functions | Cylindrical and spherical surface compensation |
| Data Output | USB and RS-232C interfaces |
| Power Supply | AC 100–115 V / 240 V, 50/60 Hz |
| Dimensions (W×D×H) | 186 × 450 × 504 mm |
| Weight | ~40 kg (including tool case) |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM-310e |
| Test Load Range | 1 g to 1000 g (selectable combinations) |
| Maximum Test Load | 1000 g |
| Specimen Height Clearance | 95 mm (H) × 115 mm (D) |
| Compliance | JIS B7734, JIS B7735, ASTM E384, ISO 6507-2 |
| Display | 7-inch Full-Color LCD Touchscreen (FM-810 Controller Unit) |
| Optional Features | Digital Micrometer Integration, Automatic Indentation Measurement (AR System), Up to Four Objective Lenses (5×, 10×, 20×, 40×, 50×, 100×), Cylindrical & Spherical Surface Correction, HV/HK/HBW/HS/KC Toughness Testing Modes |
| Data Interface | USB & RS232C |
| Power Supply | AC 100–115 V / 240 V, 50/60 Hz |
| Dimensions (W×D×H) | 186 × 450 × 504 mm |
| Weight | ~40 kg (incl. tool case) |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM-700 |
| Instrument Type | Microhardness Tester |
| Measurement Range | 1–5000 HV |
| Total Test Load | 2 kgf |
| Maximum Specimen Height | 95 mm |
| Maximum Specimen Depth | 115 mm |
| Compliance | JIS B 7734, JIS B 7735, ASTM E384, ISO 6507-2 |
| Optional Automation | Motorized X-Y Stage, Auto-indent Recognition System (AR-Vickers), FT-ZERO Hardness Analysis Software |
| Standard Optical Configuration | 10× & 50× Objectives (up to 4 objectives supported) |
| Indentation Measurement | Digital Image-Based (1.3 MP CMOS camera), Resolution: 0.01 µm at 500× magnification |
| Load Application | Fully Automatic Loading–Holding–Unloading Cycle (60 µm/sec), Hold Time Adjustable from 5–99 s |
| Focus Mechanism | Manual Coaxial Fine/Coarse Adjustment |
| Turret | Motorized (FM-810 control unit) |
| Display Interface | 7-inch Full-Color LCD Touchscreen (FM-810 Unit) |
| Data Output | USB & RS-232C |
| Power Supply | AC 100–115 V / 240 V, 50/60 Hz |
| Dimensions (W×D×H) | 186 × 450 × 504 mm |
| Weight | ~40 kg (incl. tool case) |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM-810 |
| Indentation Load Range | 1 g to 2000 g (selectable combinations) |
| Maximum Test Load | 2000 g |
| Specimen Height Clearance | 95 mm (H) × 115 mm (D) |
| Optical System | Dual-standard objective lenses (10× & 50×), expandable up to four objectives (5×, 20×, 40×, 100×) |
| Measurement Resolution | 0.01 µm (at 500× magnification) |
| Display | 7-inch full-color LCD touch interface |
| Compliance | JIS B 7734 / B 7735, ASTM E384, ISO 6507-2, ISO 8507-2, SAE J417b, ASTM E140 |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM-810e |
| Indentation Load Range | 1 g to 2000 g (selectable combinations) |
| Maximum Test Load | 2000 g |
| Specimen Height Clearance | 95 mm (H) × 115 mm (D) |
| Optical System | Dual-standard objective lenses (10× & 50×), expandable up to four objectives (5×, 20×, 40×, 100×) |
| Measurement Accuracy | Compliant with JIS B7725, JIS B7734, ASTM E384, ISO 6507-2, and ISO 8507-2 |
| Display Interface | 7-inch full-color LCD touchscreen with integrated control logic |
| Data Output | USB and RS232C interfaces |
| X-Y Stage | Manual, 100 mm × 100 mm travel, 25 mm × 25 mm fine adjustment range |
| Weight | Approx. 40 kg (including tool case) |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | ARS-9000 |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 1–5000 HV/HK |
| Total Test Force | 1000 gf (9.807 N) |
| Maximum Specimen Height | 95 mm |
| Maximum Specimen Depth | 115 mm |
| Minimum Indentation Size | 16 µm (diagonal) |
| Repeatability | ±0.5% at HV500 |
| Minimum Measuring Unit | 0.1 µm |
| XY Stage Travel (FM/FV Series) | 50 mm × 50 mm |
| XY Stage Resolution | 1 µm |
| Camera | 1.3 MP CMOS |
| Software | FT-ZERO |
| Compatible Models | FM-110/310/810, FV-110/310/810, FLV-10/50 (ARS/ARS-F only) |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM-ARS9000 |
| Indentation Measurement Principle | Digital Image Analysis with Shadow-Based Edge Detection |
| Total Test Load | 1000 gf (9.807 N) |
| Measurement Range | HV 1–5000 |
| Maximum Specimen Height | 95 mm |
| Maximum Specimen Depth | 115 mm |
| Minimum Indentation Size | 16 µm (diagonal) |
| XY Stage Travel (FM/FV Series) | 50 mm × 50 mm |
| XY Stage Travel (FLV Series) | 180 mm × 110 mm |
| Minimum Stage Resolution | 1 µm |
| Optical Resolution | 0.1 µm |
| Hardness Scales | HV, HK |
| Repeatability | ±0.5% at HV500 (500 gf load) |
| Camera | 1.3 MP CMOS sensor |
| Software | FT-ZERO v3.x (with ASTM E384, ISO 6507, JIS Z2244 compliance support) |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM110-ARSF |
| Total Test Force | 1000 gf |
| Measurement Range | 1–1000 gf selectable |
| Test Height | 95 mm (H) × Depth: 115 mm |
| Minimum Indentation Size | 16 µm (diagonal) |
| Minimum Resolution | 0.1 µm |
| Repeatability | ±0.5% at HV500 (500 gf load) |
| XY Stage Travel (FM/FV Series) | 50 mm × 50 mm |
| Minimum Stage Step | 1 µm |
| Hardness Scales | HV, HK |
| Camera | 1.3 MP CMOS |
| Software | FT-ZERO |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM310-ARSF |
| Instrument Type | Vickers Hardness Tester |
| Test Force Range | 1 g to 2000 g (selectable combinations) |
| Maximum Test Load | 2000 g |
| Testing Space | 95 mm (H) × 115 mm (D) |
| Minimum Indentation Size | 16 µm (diagonal) |
| Measurement Resolution | 0.1 µm |
| Repeatability | ±0.5% at HV500 (≈500 gf) |
| Indentation Measurement Method | Shadow-image processing with automated optical recognition |
| Hardness Scales | HV (Vickers), HK (Knoop) |
| Auto XY Stage | FM/FV-series: 110 mm × 110 mm travel (X/Y ±50 mm), 1 µm step resolution |
| FLV-series | 150 mm × 150 mm travel (X/Y 180 mm × 110 mm), 1 µm step resolution |
| Camera | 1.3 MP CMOS sensor (1300 × 1024 pixels) |
| Software | FT-ZERO control and data analysis suite |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FM810-ARSF |
| Indentation Force Range | 1 g–2000 g (selectable) |
| Maximum Test Load | 2000 g |
| Test Height | 95 mm |
| Test Depth | 115 mm |
| Minimum Indentation Size | 16 µm (diagonal) |
| Measurement Resolution | 0.1 µm |
| Repeatability | ±0.5% at HV500 (~500 gf) |
| Hardness Scales | HV, HK |
| XY Stage Travel (FM/FV series) | 50 mm × 50 mm |
| Minimum Stage Step | 1 µm |
| Camera | 1.3 MP CMOS |
| Software | FT-ZERO |
| Compliance | ASTM E384, ISO 6507-1, JIS Z 2244 |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | FR-1E |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | 20–80 HRC (typical scale) |
| Total Test Force | 150 kgf (1471 N) |
| Maximum Specimen Height | 255 mm |
| Vertical Travel | 255 mm |
| Load Axis Stability | High-sensitivity vertical load column with anti-lateral displacement guide rods |
| Calibration | Multi-point reference correction (low/medium/high), compliant with JIS Z 2245, ISO 6508-1, ASTM E18 |
| Geometry Correction | Spherical & cylindrical specimen diameter input for curvature compensation |
| Indentation Depth Display | Max. penetration depth shown simultaneously with hardness value |
| Data Output | RS-232C + USB adapter supported |
| Power Supply | AC 100 / 115 / 220 V, 50 / 60 Hz |
| Net Weight | 82 kg |
| Dimensions (W×D×H) | 196 × 487 × 820 mm |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FR-3E |
| Rockwell Scale Range | 20–88 HRC/HRB equivalent |
| Total Test Force | 150 kgf |
| Maximum Specimen Height | 255 mm |
| Vertical Travel | 255 mm |
| Load Axis Stability | High-sensitivity vertical load column with lateral displacement suppression |
| Calibration | Multi-point reference correction (low/mid/high) per JIS Z 2245, ISO 6508-1, ASTM E18 |
| Geometry Correction | Spherical/cylindrical specimen diameter input for curvature compensation |
| Indentation Depth Display | Max. indenter penetration depth shown simultaneously with hardness value |
| Data Output | RS-232C + USB adapter supported |
| Power Supply | AC 100/115/220 V, 50/60 Hz |
| Net Weight | 82 kg |
| Dimensions (W×D×H) | 196 × 487 × 820 mm |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | FR-X1 |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | 20–88 HRC (typical scale) |
| Total Test Force | 150 kgf (1.471 kN) |
| Maximum Specimen Height | 255 mm |
| Depth of Throat | 165 mm |
| Power Supply | AC 100/115/220 V, 50/60 Hz |
| Net Weight | 82 kg |
| Dimensions (W×D×H) | 196 × 487 × 820 mm |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | FR-X3 |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | 20–88 HRC (typical scale) |
| Total Test Force | 150 kgf (1.471 kN) |
| Maximum Specimen Height | 255 mm |
| Vertical Travel | 255 mm |
| Load Axis Stability | Precision vertical guide rod with lateral displacement suppression |
| Indenter Penetration Depth Display | Yes, simultaneous with hardness value |
| Calibration Correction | Multi-point (low/mid/high) per JIS Z 2245 / ASTM E18 / ISO 6508 |
| Geometry Correction | Spherical & cylindrical specimen diameter input for curvature compensation |
| Data Output | RS-232C + USB via adapter |
| Power Supply | AC 100 / 115 / 220 V, 50 / 60 Hz |
| Net Weight | 83 kg |
| Dimensions (W×D×H) | 196 × 487 × 820 mm |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | FV-310 |
| Hardness Scale | Vickers (HV) |
| Measurement Range | 0–3000 HV |
| Total Test Force | 50 kgf |
| Maximum Specimen Height | 210 mm |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Weight | ~55 kg |
| Compliance | JIS R 1607 (Fracture Toughness Kc), ISO 6507, ASTM E384 |