Empowering Scientific Discovery

Cole-Parmer 74903-06 Single-Channel High-Pressure Syringe Pump

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Cole-Parmer
Origin USA
Model 74903-06
Flow Rate 1 nL/h – 145.5 mL/min
Accuracy ±0.5%
Repeatability ±0.2%
Linear Force >45 kg
Syringe Capacity Range 2.5–200 mL
Syringe Drive Speed 9.5 nm/min
Output Interface RS232
Dimensions (W×H×D) 28 × 15.2 × 24 cm
Power Supply 230 V, 50/60 Hz
Compliance CE-certified

Overview

The Cole-Parmer 74903-06 Single-Channel High-Pressure Syringe Pump is an electromechanically actuated precision fluid delivery system engineered for demanding laboratory and process applications requiring controlled, pulseless, and highly reproducible volumetric dosing. Operating on a stepper motor-driven linear actuator principle, the pump converts rotational motion into precise axial displacement of the syringe plunger—enabling accurate metering across an exceptionally wide dynamic flow range (1 nL/h to 145.5 mL/min). Its high-force architecture (>45 kg linear thrust) supports injection into elevated backpressure environments—including pressurized reactors, microfluidic chips with narrow channels, packed-bed columns, and viscous chemical systems—without flow deviation or stalling. Designed for integration into automated workflows and continuous process monitoring, the 74903-06 meets fundamental requirements for traceable, repeatable liquid handling in analytical chemistry, catalysis research, pharmaceutical formulation development, and materials synthesis.

Key Features

  • High-force linear actuation system delivering >45 kg of push/pull force—optimized for high-viscosity fluids (e.g., polymer melts, slurries, silicone oils) and elevated backpressure conditions up to 10 MPa when paired with compatible stainless-steel syringes.
  • Wide programmable flow range: 1 nanoliter per hour (nL/h) to 145.5 milliliters per minute (mL/min), enabling both ultra-trace reagent addition and bulk transfer within a single platform.
  • High metrological performance: ±0.5% volumetric accuracy and ±0.2% repeatability under ISO 8536-4 and ASTM D3418 verification protocols; validated using gravimetric and timed-volume methods.
  • Backlit LCD interface with intuitive menu navigation; supports multi-step programmable protocols including ramped flow profiles, pause/resume sequences, and volume-triggered endpoint actions.
  • RS232 serial communication port for bidirectional control and data logging—compatible with LabVIEW, MATLAB, Python-based automation frameworks, and SCADA systems.
  • CE-marked design compliant with IEC 61000-6-2 (EMC immunity) and IEC 61000-6-3 (EMC emissions); constructed with industrial-grade PCBs and reinforced chassis for long-term operational stability.

Sample Compatibility & Compliance

The 74903-06 is fully compatible with glass, polypropylene, and 316 stainless-steel syringes (2.5–200 mL), with optional Viton® fluoroelastomer plungers ensuring chemical resistance against organic solvents, strong acids, and bases. Swagelock®, Luer Lock, and NPT interface options allow secure, leak-tight connections to reactor manifolds, HPLC lines, or custom microfluidic assemblies. The pump’s mechanical design conforms to GLP and GMP-aligned operation principles: all parameter changes are timestamped and logged via RS232 output, supporting audit-ready documentation. While not inherently 21 CFR Part 11 compliant, its deterministic firmware behavior and external logging capability enable integration into validated systems when paired with compliant software platforms.

Software & Data Management

Native operation requires no proprietary software—parameter configuration and real-time status monitoring occur directly via front-panel controls. For advanced automation, Cole-Parmer provides ASCII command protocol documentation (including ‘RUN’, ‘STOP’, ‘SET RATE’, ‘GET STATUS’) facilitating seamless integration with third-party control environments. Users may implement full audit trails by capturing RS232 output streams into timestamped CSV files, aligning with ISO/IEC 17025 data integrity expectations. Optional PC-based utilities (e.g., Cole-Parmer Pump Control Software v3.x) support graphical protocol building, batch execution, and export of flow-vs.-time datasets for post-acquisition analysis in Origin or Excel.

Applications

  • Precise catalyst or initiator dosing into high-pressure hydrogenation or polymerization reactors.
  • Controlled reagent addition in kinetic studies where stoichiometric accuracy at sub-microliter increments affects reaction pathway selectivity.
  • Calibration fluid delivery for flow sensor validation across multiple decades of flow rate.
  • Continuous infusion in electrochemical cell experiments requiring stable electrolyte replenishment under variable cell impedance.
  • Microscale sample introduction into ICP-MS or LC-MS systems where pulsation-induced signal noise must be minimized.
  • Long-duration environmental simulation studies involving slow-release nutrient or contaminant dosing into bioreactors.

FAQ

What syringe materials are recommended for high-pressure operation?
316 stainless-steel syringes with Viton® or Kalrez® seals are strongly recommended for pressures exceeding 1 MPa and aggressive chemistries. Glass syringes are limited to ≤0.5 MPa and non-corrosive media.
Can this pump operate in continuous unattended mode for 72+ hours?
Yes—when configured with appropriate syringe size and flow rate, the 74903-06 maintains thermal stability and positional fidelity over extended runs; internal temperature rise remains <2 °C after 48 h at rated load.
Is firmware upgrade support available from Cole-Parmer?
Firmware updates are distributed exclusively through authorized Cole-Parmer service centers and require hardware-level verification; no user-accessible flash interface is provided.
Does the RS232 interface support hardware handshaking (RTS/CTS)?
No—the interface implements basic asynchronous serial communication (8N1, 9600 baud default); flow control must be managed at the host application layer.
How is calibration traceability established for regulatory submissions?
Users perform in-house calibration using NIST-traceable gravimetric standards; Cole-Parmer supplies calibration certificates upon request for factory-tested units (additional fee applies).

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0