- All
- Favorite
- Popular
- Most rated
| Brand | Huatong NMR (HTNMR) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Preclinical MRI System |
| Animal Model | Rat |
| Magnetic Field Strength | 1.2 T ±0.05 T |
| Proton Resonance Frequency | 51 MHz ±2 MHz |
| Magnet Pole Diameter | 300 mm |
| Effective Imaging Volume (Coil Bore) | Φ50 mm × H80 mm |
| Field Homogeneity | <8 ppm over 50 mm × 50 mm × 80 mm DSV |
| Spatial Resolution (in-plane) | 0.08 mm (measured on 0.05 mm water phantom) |
| Gradient Strength | 10 G/cm (100 mT/m) |
| Max Gradient Amplitude | 200 mT/m (X/Y/Z) |
| Image Matrix | Up to 256 × 256 × 128 |
| Image Linearity | >98% in X/Y/Z (50 mm × 50 mm × 80 mm) |
| Temperature Stability | ±0.005 °C chamber control, 1 m°C display resolution |
| Field Drift | <100 Hz/h (Larmor frequency drift) |
| Data Format | DICOM-compliant export |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HT-MRSI60-50 Series |
| Instrument Type | Preclinical Magnetic Resonance Imaging System |
| Animal Model | Mouse (also compatible with rat and small biological specimens) |
| Spatial Resolution (in vivo) | 0.15 mm (standard), down to 0.08 mm (high-resolution mode) |
| Field Strength | 1.5 T (permanent magnet) |
| Bore Diameter | Φ50 mm × H80 mm |
| Maximum Sample Depth | 50 mm |
| Image Matrix Options | 128×128×128 (standard), 256×256×128 (high-res), 512×512×128 (ultra-high-res) |
| Nuclei Supported | ¹H, ¹⁹F, ³¹P |
| Magnetic Field Homogeneity | ≤8 ppm over DSV 30 mm |
| Field Stability | ≤100 Hz/h frequency drift |
| Shielding | Integrated self-shielding (no external RF or magnetic shielding required) |
| Cryogen-Free | Yes (permanent magnet design) |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HTNMR (Huantong NMR) |
| Model | HT-3DNMR-25 |
| Instrument Type | Benchtop Permanent-Magnet MRI System |
| Field Strength | 0.45–0.5 T |
| ¹H Resonance Frequency | 18–22 MHz |
| Bore Diameter | 150 mm |
| Effective Imaging Volume (FOV) | 25 mm × 25 mm × 25 mm |
| Gradient Strength | 10 G/cm (max 70 mT/m per axis) |
| Spatial Resolution (isotropic) | 0.08 mm (high-res mode) |
| Image Matrix | Up to 256 × 256 × 128 |
| Magnetic Homogeneity | < 8 ppm over 25 mm DSV |
| Temperature Stability | ±0.06 K/h (after 2 h warm-up) |
| Field Drift | ≤100 Hz/h (Larmor frequency) |
| Linearity | >98% in X/Y/Z over 20 mm DSV |
| RF Probe ID | 25 mm diameter solenoid or saddle coil |
| Sample Compatibility | Live mice (≥4 weeks), plant tissues, insects, hydrogels, food samples, polymer phantoms |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HT-MRSI60-35 |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Animal Species | Mouse (also compatible with rat and small plant specimens) |
| Maximum Sample Diameter | 35 mm |
| Maximum Sample Height | 50 mm |
| Spatial Resolution | 0.08 mm (high-resolution mode) |
| Field Homogeneity | ≤ 8 ppm over DSV 20 mm |
| Field Stability | Frequency drift ≤ 100 Hz/h |
| Imaging Matrix Options | 128×128×128 (standard), 256×256×128 (high-res), 512×512×128 (ultra-high-res) |
| Multi-nuclear Capability | ¹H, ¹⁹F, ³¹P |
| Magnet Type | Permanent Magnet (1.5 T) |
| Cryogen-Free | Yes |
| Passive Shielding | Integrated self-shielding design |
| RF Coil Configuration | Tunable multi-nuclei volume coil (standard) |
| Number of Simultaneous Samples | 1 |
| Brand | HTNMR |
|---|---|
| Model | HT-LFMR |
| Field Strength | < 0.5 T |
| Animal Compatibility | Mouse (in vivo) |
| Maximum Sample Penetration Depth | 60 mm |
| Bore Diameter Options | 40 mm / 60 mm |
| Operating Temperature Range | Customizable (Low-Temp & High-Temp Options Available) |
| Primary Measurement Parameters | T₁ Relaxation Time, T₂ Relaxation Time, Diffusion Coefficient (D) |
| Application Domain | Non-Destructive Quantitative Analysis of Water Distribution, Oil Content, Seed Viability, Food Quality, and Biomaterial Microstructure |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HTNMR Scientific Equipment Co., Ltd. |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Animal Model | Rat (also compatible with mouse) |
| Spatial Resolution | 0.15 mm |
| Field of View (FOV) | 50 mm |
| Matrix Sizes | 128×128×128 (standard), 256×256×128 (high-resolution), 512×512×128 (ultra-high-resolution) |
| Maximum Sample Depth | 50 mm |
| Sample Capacity | 1 animal per scan |
| Magnet Type | Permanent magnet (cryogen-free) |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HT-AMNMR-50 |
| Instrument Type | Benchtop Permanent-Magnet MRI System |
| Animal Model Compatibility | Rat |
| Magnetic Field Strength | 0.3–0.54 T |
| ¹H Resonance Frequency | 18–23 MHz |
| Magnet Bore Diameter | 250 mm |
| Sample Aperture | Φ50 mm |
| Magnetic Field Homogeneity | <8 ppm over 45×45×45 mm³ |
| Image Matrix | up to 256×256×128 |
| Spatial Resolution | down to 0.08 mm (isotropic) |
| Temperature Stability | ±0.06 K/h (after 2-h warm-up) |
| Field Drift | ≤100 Hz/h (Larmor frequency) |
| Maximum Gradient Strength | 70 mT/m (X/Y/Z) |
| Image Linearity | >98% over 50×50×50 mm³ |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Animal Model Compatibility | Rat, Mouse |
| Field of View (FOV) | 50 mm diameter × 80 mm height |
| Maximum Sample Diameter | Φ50 mm |
| Detection Depth | 50 mm |
| Spatial Resolution | 0.15 mm (standard mode), 0.08 mm (high-resolution mode) |
| Image Matrix Options | 128×128×128, 256×256×128, 512×512×128 |
| Magnetic Field Homogeneity | ≤8 ppm over 20 mm DSV |
| Field Stability | Frequency drift ≤100 Hz/h |
| Multi-Nucleus Capability | ¹H, ¹⁹F, ³¹P |
| Magnet Type | Permanent Magnet (1.5 T) |
| Cryogen-Free Operation | Yes |
| Passive Shielding | Integrated self-shielding design |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HT-MRSI60-25 |
| Instrument Type | Magnetic Resonance Imaging (MRI) & Magnetic Resonance Spectroscopic Imaging (MRSI) System |
| Spatial Resolution | 0.8 ppm (chemical shift resolution) |
| Field of View (FOV) | 25 mm × 30 mm |
| Magnetic Field Strength | 1.5 T |
| ¹H Resonance Frequency | 55–59 MHz |
| Homogeneity | <2 ppm over 25 mm DSV |
| Temperature Stability | ±0.06 K/h after 2-h warm-up |
| SNR | 55 dB |
| Geometric Distortion | <1% |
| Image Matrix | Up to 512 × 512 (2D), 128 × 128 × 128 (3D), 64 × 64 × 64 × 64 (4D MRSI) |
Show next