| Brand | HTNMR (Huanton NMR) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Benchtop NMR |
| Model | GY-PNMR12-6 |
| Price Range | USD 70,000 – 140,000 |
| Instrument Type | Low-Field Pulsed Fourier Transform NMR Spectrometer |
| Sample Form | Liquid Solutions Only |
| Operating Frequency | 60 MHz (¹H resonance) |
| Excitation Method | Pulsed Fourier Transform (PFT-NMR) |
| Sensitivity | 10,000:1 (S/N ratio, CH₃ signal of 98% ethanol, 32 scans) |
| Resolution | ≤ 0.03 ppm (full width at half maximum, FWHM, in ¹H spectrum of CHCl₃ in CDCl₃) |
| Quantitative Reproducibility (¹H) | < 1% RSD (relative standard deviation, n = 10) |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | High-Field Benchtop NMR Spectrometer |
| Sample Form | Liquid |
| Operating Frequency | 90 MHz (¹H) |
| Data Acquisition Method | Pulsed Fourier Transform (PFT-NMR) |
| Sensitivity | 10,000:1 (S/N, CH₃ peak of 98% ethanol, 32 scans) |
| Resolution | 0.5 Hz (0.011 ppm at 90 MHz) |
| Magnet System | Permanent Rare-Earth Magnet (No Cryogen Required) |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P (software-selectable) |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Preclinical MRI Scanner |
| Sample Compatibility | Solid & Liquid Samples (In Vivo & Ex Vivo) |
| Sensitivity | 52 dB |
| Spatial Resolution | 0.05 mm (Isotropic, Water Phantom Standard) |
| Magnetic Field Strength | 1.2 T ± 0.05 T |
| Proton Resonance Frequency | 51 MHz ± 2 MHz |
| Magnet Bore Diameter | 300 mm |
| Effective Imaging Volume | Φ50 mm × H75 mm |
| Magnetic Homogeneity | <8 ppm over 50 mm × 50 mm × 70 mm DSV |
| Gradient Strength | 100 mT/m (X/Y/Z) |
| Image Matrix | Up to 256 × 256 × 128 |
| Linearity | >98% in X/Y/Z (50 mm × 50 mm × 75 mm FOV) |
| Temperature Stability | ±0.005 °C (Cavity Control), Display Resolution: 1 m°C |
| Field Drift | <100 Hz/h (Larmor Frequency) |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Model | HT-MRSI40-60KY |
| Magnetic Field Strength | 1.0 T ± 0.05 T |
| Proton Larmor Frequency | 42 MHz ± 2 MHz |
| Magnet Bore Diameter | 300 mm |
| Effective Sample Volume (RF Coil) | Φ60 mm × H80 mm |
| Spatial Resolution (Max) | 0.05 mm (measured with 0.05 mm water phantom) |
| Gradient Strength | 100 mT/m (X/Y/Z) |
| Field Homogeneity | < 8 ppm over 50 mm × 50 mm × 80 mm DSV |
| Image Linearity | > 98% in X/Y/Z (50 mm × 50 mm × 80 mm) |
| Temporal Stability | < 100 Hz/h Larmor frequency drift |
| Temperature Control Stability | ±0.005 °C (cavity), display resolution 1 m°C |
| Image Matrix | Up to 256 × 256 × 128 |
| DICOM Compliance | Yes |
| Sensitivity | 52 dB |
| Resolution | 98% |