BrandHTNMR (Huanton NMR)
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic Benchtop NMR
ModelGY-PNMR12-6
Price RangeUSD 70,000 – 140,000
Instrument TypeLow-Field Pulsed Fourier Transform NMR Spectrometer
Sample FormLiquid Solutions Only
Operating Frequency60 MHz (¹H resonance)
Excitation MethodPulsed Fourier Transform (PFT-NMR)
Sensitivity10,000:1 (S/N ratio, CH₃ signal of 98% ethanol, 32 scans)
Resolution≤ 0.03 ppm (full width at half maximum, FWHM, in ¹H spectrum of CHCl₃ in CDCl₃)
Quantitative Reproducibility (¹H)< 1% RSD (relative standard deviation, n = 10)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeHigh-Field Benchtop NMR Spectrometer
Sample FormLiquid
Operating Frequency90 MHz (¹H)
Data Acquisition MethodPulsed Fourier Transform (PFT-NMR)
Sensitivity10,000:1 (S/N, CH₃ peak of 98% ethanol, 32 scans)
Resolution0.5 Hz (0.011 ppm at 90 MHz)
Magnet SystemPermanent Rare-Earth Magnet (No Cryogen Required)
Nuclei Supported¹H, ¹³C, ¹⁹F, ³¹P (software-selectable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypePreclinical MRI Scanner
Sample CompatibilitySolid & Liquid Samples (In Vivo & Ex Vivo)
Sensitivity52 dB
Spatial Resolution0.05 mm (Isotropic, Water Phantom Standard)
Magnetic Field Strength1.2 T ± 0.05 T
Proton Resonance Frequency51 MHz ± 2 MHz
Magnet Bore Diameter300 mm
Effective Imaging VolumeΦ50 mm × H75 mm
Magnetic Homogeneity<8 ppm over 50 mm × 50 mm × 70 mm DSV
Gradient Strength100 mT/m (X/Y/Z)
Image MatrixUp to 256 × 256 × 128
Linearity>98% in X/Y/Z (50 mm × 50 mm × 75 mm FOV)
Temperature Stability±0.005 °C (Cavity Control), Display Resolution: 1 m°C
Field Drift<100 Hz/h (Larmor Frequency)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypePreclinical Magnetic Resonance Imaging (MRI) System
ModelHT-MRSI40-60KY
Magnetic Field Strength1.0 T ± 0.05 T
Proton Larmor Frequency42 MHz ± 2 MHz
Magnet Bore Diameter300 mm
Effective Sample Volume (RF Coil)Φ60 mm × H80 mm
Spatial Resolution (Max)0.05 mm (measured with 0.05 mm water phantom)
Gradient Strength100 mT/m (X/Y/Z)
Field Homogeneity< 8 ppm over 50 mm × 50 mm × 80 mm DSV
Image Linearity> 98% in X/Y/Z (50 mm × 50 mm × 80 mm)
Temporal Stability< 100 Hz/h Larmor frequency drift
Temperature Control Stability±0.005 °C (cavity), display resolution 1 m°C
Image MatrixUp to 256 × 256 × 128
DICOM ComplianceYes
Sensitivity52 dB
Resolution98%