- All
- Favorite
- Popular
- Most rated
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | GSP-45 |
| Temperature Range | RT+5–65°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity (Stability) | ±0.2°C |
| Heating Method | Water-jacketed |
| Power Consumption | 0.4 kW |
| Timer Range | 0–999.9 min/h |
| Chamber Dimensions (W×D×H) | 350×300×400 mm |
| External Dimensions (W×D×H) | 500×520×710 mm |
| Standard Shelving | 2 shelves, 15 kg/shelf |
| Net Weight | 43 kg |
| Gross Weight | 50 kg |
| Power Supply | 220 V / 50 Hz |
| Brand | Labotery |
|---|---|
| Model | MJL-80 / MJL-150 / MJL-250 / MJL-350 / MJL-450 |
| Temperature Range | 0–65 °C (without humidity), 10–65 °C (with humidity) |
| Humidity Range | 40–90 %RH |
| Humidity Accuracy | ±5–8 %RH |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.3 °C |
| Working Chamber Volume | 80–450 L |
| Power Supply | 220 V, 50 Hz |
| Refrigerant | R134a |
| Heating Power | 0.3–1.5 kW |
| Chamber Dimensions (W×D×H, mm) | 500×350×500 to 600×710×1000 |
| External Dimensions (W×D×H, mm) | 640×610×970 to 740×965×1470 |
| Net Weight | 70–140 kg |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | XJT16-20 / XJT20-20 / XJT40-20 / XJS60-24 / XJS20-42 / XJS40-42 |
| Heating Method | High-Purity Graphite Block with PTFE Coating |
| Max Temperature | 220 °C / 260 °C / 450 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Inter-hole Uniformity | ±1.5 °C |
| Sample Capacity | 20×100 mL / 40×50 mL / 60×50 mL / 20×100 mL / 40×50 mL |
| Heating Power | 1800–3000 W |
| Control System | 30-Step Programmable LCD Controller with PID Auto-Tuning |
| Safety Features | Over-Temperature Alarm, Acid-Resistant Modular Design, Reflux Venting |
| Compliance | Designed for EPA 3010a, 3050b, 3060 |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | DS12-35 / DS12-45 |
| Heating Power | 2.5 kW |
| Max. Temperature | 460 °C |
| Temperature Uniformity | ±2 °C |
| Plate Dimensions | 400 × 300 mm |
| Heating Zone | 380 × 280 mm |
| Display | Digital LED |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | LX-09A |
| Instrument Type | Integrated |
| Cooling Method | Water-cooled |
| Temperature Control Range | 8–35 °C |
| Temperature Stability | ±1.0 °C |
| Refrigeration Capacity | 900 W @ 25 °C |
| Circulation Pump Pressure | 1.5 bar |
| Flow Rate | 4 L/min @ 1.5 bar |
| Reservoir Volume | 9 L |
| Operating Mode | Continuous |
| Refrigerant | R-134a |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 400 × 590 × 541 mm |
| Temperature Resolution | 0.1 °C |
| Total Power Consumption | 660 W |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228A |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm / 50 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Control Method | PID Microprocessor |
| Shelf Dimensions | 850 × 530 mm |
| Single-Shelf Capacity | 100 mL × 95, 250 mL × 56, 500 mL × 38, 1000 mL × 22, or 2000 mL × 12 |
| Standard Shelf Load | 100 mL × 45, 250 mL × 28, 500 mL × 28, 1000 mL × 14, or 2000 mL × 9 |
| Power per Shelf | 1.5 kW |
| Voltage | AC 220 V ±10%, 50–60 Hz |
| Single-Shelf External Dimensions | 1368 × 900 × 600 mm |
| Net Weight per Shelf | 220 kg |
| Environmental Operating Range | 5–25 °C |
| Display | 7-inch 16-bit true-color touchscreen |
| Data Storage | 1-year history retention |
| Connectivity | USB data export, optional remote monitoring via mobile app |
| Safety Features | Door-safety interlock, over-temperature alarm & cutoff, self-diagnostic system, encrypted operation lock, condensate drainage port, IPX4-rated motor, double-layer waterproof baffle, UV sterilization lamp, integrated LED illumination |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | YPJ-300S |
| Instrument Type | Orbital Shaker (Dual-Layer) |
| Timing Range | 0–999.9 min/h |
| Oscillation Frequency | 30–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 35 mm |
| Tray Dimensions | 800 × 600 mm |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 0.3 kW |
| External Dimensions (L×W×H) | 900 × 780 × 725 mm |
| Net Weight | 400 kg |
| Operating Ambient Temperature | 5–25 °C |
| Storage Temperature | –10–50 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Compliance | CE-marked per IEC 61000-6-3 (EMI) and IEC 61000-6-2 (Immunity) |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | LX1811 |
| Instrument Type | Box Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 7.5 kW |
| Heating Rate (to Max Temp) | ≤20 °C/min |
| Heating Element | Alloy Wire |
| Internal Chamber Dimensions | 250 × 300 × 250 mm |
| Rated Voltage | 380 V |
| Working Temperature Range | 750–1100 °C |
| Chamber Volume | 18 L |
| Net Weight | 90 kg |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | CPY-180 |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.1°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% (±0.1% with IR sensor) |
| Humidity Control Method | Natural Evaporation (>95% RH at 37°C) |
| Chamber Capacity | 180 L |
| External Dimensions (W×D×H) | 580 × 650 × 775 mm |
| Sterilization Method | 140°C Dry-Heat Sterilization |
| Standard Configuration | High-Temperature Sterilization Cycle |
| Power Supply | AC 220 V / 50 Hz |
| Input Power | 700 W |
| Heating Method | Gas-Jacketed |
| Control Interface | Full-Color Touchscreen with PID Algorithm |
| CO₂ Recovery Time (after 30-sec door opening, to 5%) | ≤5 min |
| Temperature Recovery Time (to 37°C) | ≤8 min |
| Internal Chamber Material | 304 Mirror-Finish Stainless Steel |
| Air Filtration | Integrated HEPA Filter (≥99.99% @ 0.3 µm) |
| CO₂ Inlet Filtration | 0.3 µm Microbial Filter |
| Door Heating | Yes (prevents condensation on inner glass) |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | DS24-45F |
| Heating Power | 4 kW |
| Max. Temperature | 450 °C |
| Temperature Uniformity | ±2 °C |
| Plate Dimensions | 400 × 600 mm |
| Heating Zone | 380 × 580 mm |
| Display | Digital LED |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Type | Box-Type Muffle Furnace |
| Models | LX 0211 / LX 0711 / LX 1211 / LX 1811 / LX 3611 / LX 0414 / LX 1314 / LX 1814 |
| Max Temperature | 1200 °C / 1400 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 1.2–10 kW |
| Heating Rate (to Max Temp) | ≤10 °C/min |
| Heating Elements | Kanthal A1 Alloy Wire / Silicon Carbide Rods |
| Internal Chamber Dimensions | 120×200×80 mm to 300×400×300 mm |
| Insulation | Polycrystalline Molybdenum Fiber Blankets |
| Safety Features | Auto Power-Off on Door Opening, Over-Temperature Protection, Leakage Current Protection |
| Control System | Intelligent PID Controller with Fuzzy Logic, Self-Tuning, Parameter Memory, Optional 40-Step Programmable Ramp/Soak Profile |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | DB12-20 |
| Heating Power | 2–4.5 kW |
| Max. Operating Temperature | 460 °C |
| Temperature Uniformity | ±0.3 °C |
| Heating Surface Dimensions | 300 × 400 mm or 400 × 600 mm |
| Display | LCD |
| Control Technology | Fuzzy PID with Microprocessor |
| Temperature Resolution | 0.1 °C |
| Timer Range | 1–9999 min |
| Continuous Operation Capability | ≥48 h |
| Construction Materials | 304 Stainless Steel / PTFE-Coated Aluminum / Isostatic Graphite Options |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZHP-100G |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.3°C (at 37°C) |
| Humidity Range | 20–50% RH |
| Chamber Capacity | 100 L |
| Orbital Speed | 30–400 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | Φ0–50 mm (continuously adjustable) |
| Shelf Dimensions | 400 × 370 mm |
| Max Load Capacity | 100 mL × 23 or 250 mL × 16 or 500 mL × 9 or 1000 mL × 5 or 2000 mL × 4 |
| Timer Range | 0–999.9 min |
| Power Consumption | 0.8 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions | 550 × 780 × 640 mm |
| Temperature Resolution | 0.1°C |
| Temperature Stability | ±0.3°C (at 37°C) |
| Safety Features | Door-activated stop, over-temperature alarm & auto cut-off, motor over-current protection, power failure memory, self-diagnostic system |
| Control Interface | Full-color LCD touchscreen with navigational soft keys |
| Drive System | Brushless DC servo motor with reversible programmable operation (forward/reverse/stop cycles) |
| Air Circulation | Forced convection via optimized ducted airflow path |
| Brand | Labotery |
|---|---|
| Model | LX0711 |
| Type | Box Muffle Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 3000 W |
| Heating Rate to Max Temp | 20 min |
| Heating Element | Alloy Wire |
| Internal Chamber Dimensions | 200 × 300 × 120 mm (L×W×H) |
| Compliance | JB/T 8195.7–2007, GB/Z 18–2002 |
| Safety Features | Auto-Door Cut-off, Over-Temperature Protection, Leakage Current Protection, Dual-Skin Air-Cooled Casing |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | GPL-450A |
| Temperature Range (with lighting) | 10–60 °C |
| (without lighting) | 0–60 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 30–95 %RH |
| Chamber Volume | 450 L |
| Control System | PID-based microcomputer controller with multi-segment programmable logic |
| Lighting Source | Adjustable LED cold-light array (0–25,000 lx) |
| Construction | Mirror-finish 304 stainless steel interior |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 2100 W |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQP-100G |
| Instrument Type | Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–9999 min |
| Oscillation Frequency | 30–600 rpm |
| Orbit Diameter (Amplitude) | Φ0–50 mm (infinitely adjustable) |
| Temperature Range | Ambient +5°C to 60°C |
| Shelf Quantity | 1 platform |
| Platform Dimensions | 400 × 370 mm |
| Chamber Volume | 100 L |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 0.8 kW |
| External Dimensions (W×D×H) | 550 × 780 × 640 mm |
| Temperature Uniformity | ±0.3°C (at 37°C) |
| Temperature Stability | ±0.3°C (at 37°C) |
| Temperature Resolution | 0.1°C |
| Display | LCD touchscreen interface |
| Drive System | Brushless DC servo motor with bidirectional programmable control |
| Safety Features | Door-activated stop, over-temperature alarm & auto-shutoff, current overload protection, power failure memory, self-diagnostic system |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPW-70 |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Timer Range | 0–9999 min (configurable in minutes or hours) |
| Oscillation Speed | 10–400 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4–65°C |
| Temperature Resolution | 0.1°C |
| Temp. Uniformity | ±0.5°C (at 37°C) |
| Temp. Stability | ±0.3°C (at 37°C) |
| Shelf Dimensions | 520 × 430 mm |
| Standard Capacity | 100 mL × 25 |
| Standard Fixture | Universal Spring Clamps |
| Power Consumption | 0.7 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 860 × 680 × 570 mm |
| Display | LCD with PID Microprocessor Control |
| Motor Type | Brushless DC Motor |
| Drive Mechanism | Multi-axis Integrated Eccentric Cam Drive |
| Safety Features | Door-Interlock Stop, Over-Temp Audio-Visual Alarm + Auto Cut-off, Self-Diagnostic System, Power-Fail Data Retention |
| Operating Ambient | 5–25°C |
| Cooling System | Imported CFC-Free Compressor with Optimized Heat Dissipation Architecture |
| Air Circulation | Forced Convection via Centrifugal Air Duct |
| Illumination | Built-in White LED Light |
| UV Sterilization Lamp | Integrated (254 nm) |
| Viewing Window | Tempered Double-Layer Hollow Glass Door with Ø30 mm Access Port |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | SYWF-60 |
| Instrument Type | Water Bath Orbital Shaker |
| Timer Range | 0–9999 min |
| Oscillation Frequency | 20–200 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 20 mm |
| Temperature Range | Ambient to 99.9 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.2 °C (at 37 °C, 100 rpm) |
| Control System | Fuzzy PID Microprocessor Control |
| Tray Dimensions | 340 × 470 mm |
| Tray Quantity | 1 |
| Max Capacity | 100 mL × 24 / 250 mL × 15 / 500 mL × 11 / 1000 mL × 6 |
| Water Bath Tank Dimensions (W×D×H) | 600 × 420 × 260 mm |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 2.3 kW |
| Construction | 304 Stainless Steel Bath & Tray |
| Safety Features | Low-water cutoff, Overtemperature alarm, Isolated heating system, Drain valve, Quick-release tray mechanism |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | HWL-8 |
| Instrument Type | Standard Benchtop Drying Oven |
| Temperature Range | RT+5°C to 300°C |
| Temperature Uniformity | ±1°C |
| External Dimensions (W×D×H) | 310 × 320 × 400 mm |
| Internal Chamber Dimensions (W×D×H) | 200 × 200 × 200 mm |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Encapsulated Tubular Heater |
| Power Supply | 220 VAC, 50 Hz |
| Rated Heating Power | 0.1 kW |
| Max Load Capacity | 10 kg |
| Net Weight | 10 kg |
| Operating Ambient Temperature | 5–40°C |
| Relative Humidity Limit | ≤80% RH (non-condensing) |
| Brand | Labotery |
|---|---|
| Model | DW-12F / DW-24F |
| Origin | Tianjin, China |
| Heating Power | 2.0 kW |
| Max Operating Temperature | Ambient +5°C to 400°C |
| Temperature Uniformity | ±1°C |
| Heating Surface Dimensions | 300 × 400 mm |
| Display | LCD Screen |
| Control System | PID Microprocessor with Dual Modes (Setpoint & Multi-Step Programming) |
| Safety Features | Over-Temperature Alarm, Power-Fail Memory, Timer, Auto-Tuning (AT), Scheduled On/Off |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-200R |
| Temperature Range | 4–65 °C (CO₂ mode: 4–60 °C) |
| CO₂ Range | 0–20% |
| CO₂ Uniformity | ±0.1% |
| CO₂ Control Accuracy | ±0.1% |
| Oscillation Frequency | 30–300 rpm (±1 rpm) |
| Amplitude | 26 mm (Ø) |
| Timer Range | 0–999 h 59 min |
| Shelf Quantity | 2 |
| Shelf Dimensions | 439 × 528 mm |
| Temp. Uniformity | ±0.5 °C at 37 °C |
| Temp. Resolution | 0.1 °C |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 1.3 kW |
| Net Weight | 170 kg |
| External Dimensions (W×D×H) | 740 × 780 × 1260 mm |
| Brand | Labotery |
|---|---|
| Model | SY-20 |
| Type | Benchtop Constant-Temperature Water Bath |
| Origin | Tianjin, China |
| Power Supply | 220 V AC, 50 Hz |
| Heating Power | 800 W |
| Temperature Range | RT + 5 °C to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.5 °C |
| Chamber Dimensions (L×W×H) | 500 × 300 × 200 mm |
| External Dimensions (L×W×H) | 560 × 390 × 355 mm |
| Timer Range | 1–9999 minutes |
| Construction | Stainless Steel Inner Tank and Lid |
| Control System | Microprocessor-Based PID Controller with Dual Digital Display (Set & Actual Temperature) |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-500A |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Oscillation Amplitude | Ø26 mm (standard), 50 mm (optional) |
| Temperature Range | 4–65 °C |
| Number of Shaking Platforms | 2 |
| Platform Dimensions | 830 × 500 mm each |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Resolution | ±0.1 °C |
| Frequency Accuracy | ±1 rpm |
| Power Consumption | 2.1 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1080 × 850 × 1440 mm |
| Net Weight | 300 kg |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-500 |
| Instrument Type | Full-Temperature Orbital Shaker / Incubator Shaker |
| Timer Range | 0–9999 min (up to 166.6 h) |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm / 50 mm |
| Temperature Range | 4–65 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Fluctuation | ±0.3 °C (at 37 °C) |
| Temperature Resolution | 0.1 °C |
| Control Method | PID Microprocessor-Based Control |
| Shelf Quantity | 2 adjustable platforms |
| Platform Dimensions | 830 × 508 mm per shelf |
| Power Consumption | 2.1 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1080 × 850 × 1440 mm |
| Net Weight | 300 kg |
| Compliance | Designed for GLP-compliant laboratories |
Show next