Optical Laboratory Equipment
Filter
Showing 1585–1600 of 4287 results
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCP421V-ELP |
| Temperature Range | −190 °C to 400 °C (LN₂ required for sub-ambient operation) |
| Heating Zone Diameter | 26 mm |
| Sample Cavity Height | 4.3 mm |
| Incidence/Exit Angle | 70.0° |
| Minimum Working Distance | 5 mm |
| Temperature Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temp. Resolution | 0.001 °C |
| Max. Ramp Rate | 30 °C/min |
| Min. Controlled Ramp Rate | ±0.01 °C/min |
| Sensor | 100 Ω Pt RTD |
| Control Algorithm | PID |
| Enclosure | Hermetic vacuum/gas-fillable chamber with purge ports |
| Window | Removable, exchangeable optical window |
| Defrosting | Integrated gas-purge ducting for cryogenic window anti-frosting |
| Actuation | Horizontal slide-in sample loading |
| Software Interface | PC-controlled via SDK |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCP421V-MPS |
| Temperature Range | −190 °C to 400 °C |
| Sample Diameter | 10–30 mm |
| Max Heating Rate | 30 °C/min |
| Temp Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temp Resolution | 0.01 °C |
| Minimum Objective Working Distance | 12 mm |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCP621G |
| Temperature Range | −190 °C to 600 °C (LN₂ required for sub-ambient operation) |
| Heating Zone Diameter | 26 mm |
| Airtight Chamber | Yes, with gas inlet/outlet ports |
| Window Aperture | Ø18 mm, ±58.0° max viewing angle |
| Minimum Objective Working Distance | 5 mm |
| Temperature Stability | ±0.1 °C (at <25 °C) |
| Temp. Resolution | 0.001 °C |
| Max. Heating Rate | +150 °C/min (at −100 °C) |
| Max. Cooling Rate | −50 °C/min (at 100 °C) |
| Min. Ramp Rate | ±0.01 °C/min |
| Control Sensor | 100 Ω Pt RTD |
| Control Algorithm | PID |
| Housing Cooling | Optional water circulation jacket |
| Software Interface | SDK available, programmable ramp/soak profiles, real-time curve logging |
| Brand | Instec |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | HCP621G |
| Pricing | Upon Request |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCP621G-XRD |
| Temperature Range | −190 °C to 600 °C (LN₂ required for sub-ambient) |
| Heating Zone Diameter | 26 mm |
| Sample Cavity Height | 3.5 mm |
| Temperature Stability | ±0.1 °C (at <25 °C) |
| Temp. Resolution | 0.001 °C |
| Max. Heating Rate | +150 °C/min (at −190 °C) |
| Max. Cooling Rate | −50 °C/min (at 100 °C) |
| Min. Ramp Rate | ±0.01 °C/min |
| Sensor | 100 Ω Pt RTD |
| Control Algorithm | PID |
| Atmosphere Control | Sealed gas chamber (N₂-compatible) |
| Optical Access | Removable Kapton windows, 10 mm clear aperture, incidence angle 0°–170°, anti-frost purge ports |
| Cooling | External recirculating water jacket for housing thermal management |
| Software Interface | PC-based control with programmable ramp/soak profiles, real-time curve logging, and SDK for integration into custom lab automation |
| Brand | Instec |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HCS121VXY |
| Price Range | USD 105,000 – 158,000 |
| Temperature Range | −195 °C to +150 °C |
| Temp. Resolution/Stability | 0.01 °C |
| Sensor/Control | 100 Ω Pt RTD / PID |
| Max. Cooling/Heating Rate | −100 °C/min / +150 °C/min |
| Min. Controlled Ramp Rate | ±0.01 °C/min |
| Heating Block Material | Silver |
| Sample Area Diameter | φ26 mm |
| Chamber Height | 2.5 mm |
| Standard Substrate | Quartz Crucible |
| Optical Port Diameter (Top/Bottom) | φ2 mm / φ2 mm |
| Top Window Aperture | φ18 mm, Max. Viewing Angle: ±58° |
| Bottom Window Aperture | φ18 mm, Max. Viewing Angle: ±19° |
| XY Translation Stage (External) | 10 µm Resolution, 13 mm Travel |
| Anti-Frost System | Pneumatic Purge + Auto-LN₂ Cooling (3 L Dewar) |
| Vacuum Control Range | 1013 hPa to 1×10⁻³ mbar (1 Pa to 0.1 Pa) |
| Vacuum Resolution | 0.1 Pa |
| Vacuum Interface | KF25/KF16 |
| Integrated Microscope | Transmitted/Polarized Light, 10× Standard Objective (5×/20×/50× Optional), 4-Position Infinity-Corrected Nosepiece, 30 mm Coaxial Focus Travel (0.002 mm Fine Adjustment), 20 MP Color CMOS Camera (5440 × 3648 Pixels, 2.4 µm Pixel Size), C-Mount 0.7× Adapter |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS302, HCS302XY |
| Temperature Range | −60 °C to +400 °C (LN₂ required for sub-zero operation) |
| Heating/Cooling Rates | +80 °C/min (heating at 100 °C), −40 °C/min (cooling at 100 °C) |
| Temperature Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temperature Resolution | 0.01 °C |
| Control Sensor | 100 Ω Pt RTD |
| Control Algorithm | PID |
| Sample Area | 38 mm × 50 mm |
| Sample Cavity Height | 3.5 mm (no inner lid), 2.16 mm (with inner lid) |
| Standard Substrate | 25 mm × 75 mm microscope slide |
| Side-Loading Mechanism | Quick-insertion slide carrier with manual clamping |
| XY Translation (HCS302XY only) | 10 mm travel, 10 µm resolution |
| Objective Working Distance | 5.4 mm |
| Condenser Working Distance | 10.3 mm |
| Central Aperture | Φ2 mm |
| Top Window Diameter | Φ27 mm, Viewing Angle: ±61.25° |
| Bottom Window Viewing Angle | ±45° |
| De-icing | Pneumatic purge port for window defrosting |
| Housing Cooling | Integrated water-jacket for thermal isolation |
| Mounting | Horizontal or vertical orientation |
| Dimensions | 116.84 mm × 111.76 mm × 23.11 mm |
| Weight | 670 g |
| Optical Path Compatibility | Transmission and reflection configurations |
| Replaceable Windows | User-swappable optical windows |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS302 |
| Temperature Range | −60 °C to 400 °C |
| Heating Rate | 0.01–80 °C/min (at 100 °C) |
| Cooling Rate | −0.01 to −40 °C/min (at 100 °C) |
| Temperature Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temperature Resolution | 0.01 °C |
| Sensor | 100 Ω Platinum RTD |
| Control Method | PID |
| Sample Area | 38 mm × 50 mm |
| Sample Cavity Height | 3.5 mm (no inner cover), 2.16 mm (with inner cover) |
| Optical Aperture | Ø2 mm |
| Top Window Diameter | Ø27 mm, FOV ±61.25° |
| Bottom Window FOV | ±45° |
| Objective Working Distance | 5.4 mm |
| Condenser Working Distance | 10.3 mm |
| XY Micrometer Stage Resolution | 10 µm, Travel: 10 mm |
| Dimensions | 116.84 mm × 111.76 mm × 23.11 mm |
| Weight | 670 g |
| Optional Accessories | XY micrometer stage, LN₂ cooling system, water-cooled housing kit, cavity height spacers (1.5/3.0 mm), removable inner shell, custom window materials (CaF₂, Si, ZnSe, etc.) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model Series | HCS321Gi (-80 °C to 250 °C), TSA12Gi (-25 °C to 60 °C), CLM77Ki (-190 °C to 120 °C) |
| Gas Compatibility | N₂, Ar, dry air (via dual quick-lock gas inlets) |
| Optical Window | Removable & interchangeable (CaF₂, fused silica, sapphire options) |
| Integrated Dry-Gas Purge Channel | Yes |
| Control Interface | Analog I/O + USB/RS-232 + LabVIEW-compatible SDK |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS321Gi |
| Temperature Range | –190 °C to 250 °C (with LN₂ cooling system) |
| Heating/Cooling Rate | +80 °C/min (heating at 100 °C), –30 °C/min (cooling at 100 °C) |
| Temperature Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temperature Resolution | 0.01 °C |
| Control Method | 100 Ω Pt RTD sensor with PID algorithm |
| Optical Aperture | Ø5 mm |
| Top & Bottom Viewing Windows | Ø27 mm, ±40° and ±50° maximum viewing angles respectively |
| Sample Area | 23 mm × 28 mm |
| Sample Cavity Height | 11.2 mm (without inner lid), 5.4 mm (with inner lid) |
| Working Distance (Objective) | 5.39 mm |
| Working Distance (Condenser) | 11.21 mm |
| Heating Block Material | Aluminum Oxide |
| External Cooling | Optional water circulation jacket |
| Mounting | Horizontal or vertical installation |
| Dimensions/Weight | 135 mm × 134 mm × 23.5 mm / 610 g |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS321Gi |
| Temperature Range | −190 °C to 250 °C (with LN₂ cooling system) |
| Heating/Cooling Rate | +80 °C/min (heating at 100 °C), −30 °C/min (cooling at 100 °C) |
| Temperature Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temperature Resolution | 0.01 °C |
| Control Method | 100 Ω Pt RTD sensor with PID algorithm |
| Heating Zone Dimensions | 28 mm × 30 mm with Ø5 mm optical aperture |
| Sample Cavity Height | 11.2 mm (without inner lid), 5.4 mm (with inner lid) |
| Objectives Working Distance Compatibility | ≥5.39 mm |
| Condenser Working Distance Compatibility | ≥11.21 mm |
| Top & Bottom Viewport Diameter | Ø27 mm, Field of View: ±40° (top), ±50° (bottom) |
| Enclosure | Gas-tight chamber with purgeable atmosphere |
| Software Interface | PC-controlled via SDK |
| Physical Dimensions/Weight | 135 mm × 134 mm × 23.5 mm / 610 g |
| Mounting Options | Horizontal or vertical orientation |
| Optional Accessories | LN₂ cryogenic cooling system, recirculating chiller for stage housing, custom mounting brackets |
| Brand | Instec |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HCS350G-TNS |
| Price Range | USD 55,000 – 82,000 |
| Temperature Range | −190 °C to 350 °C (LN₂ required for sub-ambient operation) |
| Heating/Cooling Rates | +120 °C/min (heating at 100 °C), −40 °C/min (cooling at 100 °C) |
| Temp. Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temp. Resolution | 0.01 °C |
| Heating Zone | 34 mm × 14 mm |
| Tensile Stroke | 0–60 mm |
| Tensile Speed | 1–5000 µm/s |
| Max. Force Options | 2 N, 20 N, 200 N, 500 N, 1000 N, 2000 N, 5000 N |
| Force Resolution | ±0.1 N (at 200 N full scale) |
| Sample Dimensions (max) | 8 mm (w) × 80 mm (l) × 2 mm (t) |
| Optical Aperture (top) | Ø38 mm, ±60° max. viewing angle |
| Optical Aperture (bottom) | Ø18 mm, ±10° max. viewing angle |
| Objective Working Distance | ≥10 mm |
| Condenser Working Distance | ≥16 mm |
| Transmission Aperture | 2 × 1.5 mm |
| Gas Environment | Sealed chamber with inert gas purging capability |
| Dew Prevention | Integrated purge gas de-frosting lines |
| Housing Cooling | Optional integrated rack-mounted chiller |
| Brand | Instec |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HCS350G-TNS |
| Price Range | USD 55,000 – 82,000 |
| Temperature Range | −190 °C to +350 °C (LN₂ required for sub-ambient operation) |
| Heating Zone | 25 mm × 16 mm |
| Max Tensile Force Options | 2 N, 20 N, 200 N, 500 N, 1000 N, 2000 N, 5000 N |
| Force Resolution | ±0.1 N (at 200 N full scale) |
| Tensile Stroke | 0–60 mm |
| Speed Range | 1.6–1000 µm/s |
| Temp. Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temp. Resolution | 0.01 °C |
| Max. Heating/Cooling Rate | +150 °C/min (at 100 °C), −40 °C/min (at 100 °C) |
| Min. Ramp Rate | ±0.01 °C/min |
| Sensor | 100 Ω Pt RTD |
| Control Algorithm | PID |
| Optical Access | Dual-side (top Ø27 mm window, ±60° max view |
| Minimum Objective Working Distance | 7.5 mm |
| Minimum Condenser Working Distance | 16 mm |
| Transmission Aperture | 2 mm × 3 mm |
| Chamber Sealing | Hermetic gas-tight cavity with purge capability |
| Optional Features | Integrated chassis cooling, anti-frost gas purge lines, customizable window materials (UV–IR broadband options), SDK for LabVIEW/Python/C++ integration |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS402 |
| Temperature Range | -190 °C to 400 °C |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Heating Configuration | Dual-Zone Resistive Heating |
| Temp. Stability | ±0.5 °C at 100 °C |
| Temp. Accuracy | ±0.1 °C (full range) |
| Min. Temp. Resolution | 0.01 °C |
| Max. Heating Rate | +130 °C/min at 100 °C |
| Max. Cooling Rate | -80 °C/min at 100 °C (with LN2-P4 accessory) |
| Working Distance | ≥7.7 mm (objective), ≥10.0 mm (condenser) |
| Sample Area | 38 × 50 mm |
| Transmission Aperture Options | 2, 5, 8, or 10 mm diameter |
| Controller | STC200 (RS232 interface, 230 V input) |
| Optional Accessories | XY-A-01 Precision Positioner (10 µm resolution), LN2-P2UF2 Cryogenic Kit (2 L dewar + dual-stage pump), WP230C Recirculating Water Pump |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS402, HCS402XY |
| Temperature Range | −60 °C to 400 °C (LN₂ required for sub-zero operation) |
| Control Method | 100 Ω Pt RTD sensor with PID algorithm |
| Max. Heating Rate | +100 °C/min (at 100 °C) |
| Max. Cooling Rate | −40 °C/min (at 100 °C) |
| Min. Ramp Rate | ±0.01 °C/min |
| Temp. Resolution | 0.01 °C |
| Temp. Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Optical Access | Dual-side viewport (top & bottom), φ27 mm clear aperture, ±47° max. top viewing angle, ±45° max. bottom viewing angle |
| Transmission Hole | Ø2 mm |
| Minimum Objective Working Distance | 7.4 mm |
| Minimum Condenser Working Distance | 10.3 mm |
| Sample Area | 38 mm × 50 mm |
| Sample Cavity Height | 2.1 mm (expandable via 1.5 mm or 3.0 mm spacers) |
| XY Translation | 10 mm travel, 10 µm resolution |
| Quick-Load Mechanism | Side-access slide carrier for 25 mm × 75 mm standard microscope slides or Instec LCH sample holders |
| Enclosure Cooling | Integrated water-jacketed housing (external chiller compatible) |
| Mounting Options | Horizontal or vertical orientation |
| De-frosting | Pneumatic purge lines for window anti-fogging at sub-zero temperatures |
| Software Interface | PC-controlled via USB/Ethernet |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS402XY |
| Temperature Range | −60 °C to 400 °C (LN₂ required for sub-zero operation) |
| Heating/Cooling Rate | +100 °C/min (at 100 °C), −40 °C/min (at 100 °C) |
| Temp. Stability | ±0.05 °C (>25 °C), ±0.1 °C (<25 °C) |
| Temp. Resolution | 0.001 °C |
| Sample Area | 38 mm × 50 mm |
| Sample Height Clearance | 2.1 mm (expandable with 1.5 mm or 3.0 mm spacers) |
| XY Translation | 13 mm travel, 10 µm resolution |
| Optical Aperture | Ø2 mm |
| Top/Bottom Window Diameter | Ø27 mm |
| Max. Objective Working Distance | 7.4 mm |
| Max. Condenser Working Distance | 10.3 mm |
| Top Viewing Angle | ±47° |
| Bottom Viewing Angle | ±45° |
| Window Defrosting | Integrated purge gas tubing |
| Housing Cooling | Optional water circulation jacket |
| Mounting | Horizontal or vertical configuration |
