| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Origin | Domestic (China) |
| Model | FLQ1004 |
| Light Source Type | Broadband Continuous Arc Lamp (Configurable for Xenon or Mercury Short-Arc Lamps) |
| Illumination Mode | External Illumination (Collimated or Diffuse Beam Delivery) |
| Integrating Sphere Diameter Options | 200 mm, 300 mm, 500 mm (Custom Diameters Available) |
| Control Interface | RS-232 / USB / Ethernet (via Integrated Controller) |
| Attenuation Mechanism | Motorized Iris Aperture + Motorized Neutral Density Filter Wheel + Electronic Shutter |
| Software Control | Windows-Based GUI with Real-Time Intensity Calibration & Log Data Export |
| Brand | Jingyigaoke |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZDS-10 |
| Component Type | Optical Instrument Subassembly |
| Focal Length | 100 mm |
| Wavelength Range | 330–900 nm (expandable to 190 nm–20 μm with optional gratings) |
| Wavelength Accuracy | ±1 nm (with 1200 lines/mm grating) |
| Wavelength Repeatability | 0.5 nm (with 1200 lines/mm grating) |
| Spectral Resolution | ≤1 nm (measured by spectral line half-width method per GB/T standard) |
| Stray Light | ≤1×10⁻³ (measured at 632.8±8 nm using He–Ne laser) |
| Dimensions (L×W×H) | 145×145×120 mm³ (optical head only, excluding motor) |
| Brand | JTONE |
|---|---|
| Model | GHX-A |
| Origin | Zhejiang, China |
| Light Source Compatibility | Mercury lamp, Xenon lamp, Metal halide lamp |
| Adjustable Power Range | 0–1000 W (Hg/Xe), 0–500 W (Metal Halide) |
| Sample Capacity | 8-position magnetic stirring station (30 mL or 50 mL quartz tubes) or optional large-volume glass reactors (250/500/1000 mL) |
| Cooling System | Dual-layer quartz cold well with external recirculating chiller (cooling capacity >1000 W, temp range: −5 °C to 100 °C) |
| Control System | Intelligent microcomputer controller with real-time voltage/current monitoring, stepwise timing, and over-temperature auto-shutdown |
| Safety Features | Radiation-shielded dark chamber with observation window, high-voltage shock-resistant lamp housing, internal irradiation design |
| Electrical Interface | Dual dedicated sockets (for lamp & stirrer), external water inlet/outlet ports |
| Compliance | Designed for laboratory-scale photochemical research under controlled irradiation conditions |
| Brand | JTONE |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GHX-AC Photocatalytic Reaction System |
| Price Range | USD 2,100 – 3,200 (FOB) |
| Light Source Compatibility | Mercury Lamp (0–1000 W), Xenon Lamp (0–1000 W), Metal Halide Lamp (0–500 W) |
| Sample Capacity | 8 × 30 mL or 50 mL quartz reaction tubes (customizable) |
| Temperature Control Range | −5 °C to 100 °C |
| Cooling Capacity | >1000 W (integrated recirculating chiller with casters and drain valve) |
| Stirring | 8-channel synchronized magnetic stirring |
| Core Components | Dual-layer quartz cold trap, light-shielded reaction chamber, integrated light source controller, quartz reaction vessels |
| Brand | JTONE |
|---|---|
| Model | GHXA |
| Origin | Zhejiang, China |
| Light Source Compatibility | Mercury Lamp (0–1000 W), Xenon Lamp (0–1000 W), Metal Halide Lamp (0–500 W) |
| Reaction Vessel Capacity | 30 mL or 50 mL quartz tubes (standard) |
| Parallel Sample Capacity | 8 positions (customizable) |
| Cooling | Dual-layer quartz cold well with external recirculating chiller interface |
| Control System | Integrated microprocessor-based light source controller with real-time voltage/current monitoring |
| Safety Features | Over-temperature cutoff, radiation-shielded reaction chamber with observation window |
| Stirring | Synchronized 8-channel magnetic stirring |
| Compliance | Designed for GLP-compliant photochemistry workflows |
| compatible with ISO 10678 | 2010 (photocatalytic activity assessment) and ASTM E2054 (standard practice for photochemical reactor calibration) |
| Brand | JTONE |
|---|---|
| Model | JT-GHX-A |
| Light Source Compatibility | Mercury (0–1000 W), Xenon (0–1000 W), Metal Halide (0–500 W) |
| Sample Capacity | 8 positions (30 mL or 50 mL quartz tubes, standard) |
| Cooling | Dual-layer quartz cold well with external recirculating chiller interface |
| Temperature Protection | Automatic thermal cutoff |
| Stirring | Synchronized 8-channel magnetic stirring |
| Power Control | Integrated microprocessor-based light controller with real-time voltage/current monitoring |
| Compliance | CE-marked per EN 61000-6-3/6-4 |
| Certifications | TÜV Rheinland test report included |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JT-GHX-A Photocatalytic Reaction System |
| Component Category | Optical Instrument Assembly |
| Light Sources Supported | 1000 W Mercury Lamp, 1000 W Xenon Lamp, 500 W Metal Halide Lamp |
| Sample Capacity | 8-position (30 mL or 50 mL quartz tubes, customizable) |
| Cooling | Dual-layer quartz cold trap with external recirculating chiller interface |
| Control | Intelligent microprocessor-based controller with real-time voltage/current monitoring, stepwise timing, and adjustable light intensity |
| Safety | Radiation-shielded reaction chamber with observation window, over-temperature protection with automatic power cutoff |
| Stirring | Synchronized 8-channel magnetic stirring |
| Compliance | Designed for laboratory-scale photocatalysis research under controlled irradiation conditions |
| Brand | JTONE |
|---|---|
| Origin | Beijing, China |
| Model | JT-GHX-AC |
| Light Source Type | Broadband UV-Visible Lamp System (Hg, Xe, Metal Halide) |
| Lamp Power Range | Hg/Xe: 0–1000 W (continuously adjustable) |
| Metal Halide | 0–500 W (continuously adjustable) |
| Sample Capacity | 8 × quartz tubes (30 mL or 50 mL standard) |
| Stirring | 8-channel synchronized magnetic stirring |
| Temperature Control | -5°C to 100°C via recirculating chiller (cooling capacity >1000 W) |
| Cooling | Dual-layer quartz cold trap + external water chiller with casters and drain valve |
| Compliance | Designed for laboratory-scale photochemical research under controlled irradiation and thermal conditions |
| Brand | JTONE |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JT-GHX-AC |
| Price Range | USD 2,400 – 3,250 (FOB) |
| Component Category | Photoreactor System |
| Light Sources Supported | 1000 W Mercury Lamp, 1000 W Xenon Lamp, 500 W Metal Halide Lamp |
| Illumination Modes | UV and Simulated Visible Light |
| Sample Capacity | 8-position (configurable to 6 or 12) |
| Reaction Vessel Options | Quartz tubes (30 mL or 50 mL standard) |
| Cooling System | Dual-layer quartz cold finger with external recirculating chiller (–5 °C to 100 °C control range, >1000 W cooling capacity) |
| Power Regulation | Continuous electronic dimming for all lamp types |
| Stirring | Synchronized magnetic stirring across all positions |
| Safety Features | Overtemperature cutoff, radiation-shielded reaction chamber with borosilicate observation window, high-voltage lamp housing |
| Compliance | Designed for GLP-compliant photochemical kinetics studies |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JT-GHX-D Mercury Lamp Reactor |
| Component Type | Optical Instrument Assembly |
| Cooling Capacity | >1000 W |
| Temperature Control Range | −5 °C to 100 °C |
| Quartz Tube Options | 30 mL, 50 mL (customizable) |
| Multi-position Reactor | 8-tube magnetic stirring station (6/12 optional) |
| Large-volume Vessels | 250 mL / 500 mL / 1000 mL glass reactors (customizable) |
| Light Sources Supported | Mercury lamp (0–1000 W), Xenon lamp (0–1000 W), Metal Halide lamp (0–500 W) |
| Dual-layer Quartz Cold Trap | Standard |
| Water-cooling System | Integrated compressor-based chiller with silent external circulation pump |
| Safety Features | Low-water-pressure alarm, grounded 3-pin power input, electrical isolation between control unit and reaction chamber |
| Brand | JTONE |
|---|---|
| Model | JT-GHX-D |
| Type | Photocatalytic Reactor System |
| Light Source Compatibility | Mercury, Xenon, Metal Halide Lamps (0–1000 W adjustable) |
| Sample Capacity | 8-position magnetic stirring station (30–50 mL quartz tubes) or large-volume glass reactors (250/500/1000 mL) |
| Temperature Control | Dual-layer quartz cold trap with external recirculating chiller (–5 °C to 100 °C) |
| Safety | Radiation-shielded dark chamber with observation window, over-temperature auto-shutdown, high-voltage lamp housing |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JT-GHX-DC |
| Light Source Compatibility | Mercury, Xenon, and Metal Halide Lamps |
| Adjustable Lamp Power | Hg up to 1000 W, Xe up to 1000 W, MH up to 500 W |
| Sample Capacity | 8 × 30–50 mL quartz tubes (customizable) |
| Temperature Control Range | −5 °C to 100 °C |
| Compliance | Designed for laboratory-scale photocatalysis under ISO/IEC 17025-aligned operational practices |
| Component Category | Optical Instrument Subsystem |
| Brand | JTONE |
|---|---|
| Origin | Heilongjiang, China |
| Model | JT-GHX-DC |
| Light Source Compatibility | Mercury lamp (0–1000 W continuous adjustment), Xenon lamp (0–1000 W), Metal halide lamp (0–500 W) |
| Sample Capacity | 8-position quartz tube holder (30 mL or 50 mL tubes) or optional large-volume glass reactors (250/500/1000 mL) |
| Temperature Control | Dual-layer quartz cold trap with external recirculating chiller (–5 °C to 100 °C |
| Stirring | Synchronized 8-channel magnetic stirring or high-power single-reactor magnetic stirrer |
| Safety Features | Radiation-shielded dark chamber with observation window, over-temperature auto-shutdown, isolated electrical control unit |
| Compliance | Designed for laboratory-scale photocatalytic research under controlled irradiation conditions |
| Brand | Juxin Photonics |
|---|---|
| Cladding Diameter | 125 µm |
| Core Type | Double-Clad (Inner Cladding Pump Guide + Single-Mode Signal Core) |
| Doping | Ytterbium (Yb³⁺) |
| Operating Wavelength | 1030–1080 nm (Signal), 915/976 nm (Pump) |
| Numerical Aperture (Inner Cladding) | 0.46 |
| Mode Field Diameter (Signal Core) | ~6.5 µm @ 1064 nm |
| Attenuation | <25 dB/km @ 1064 nm, <50 dB/km @ 976 nm |
| Proof Test Level | ≥100 kpsi |
| Coating Diameter | 245 ± 10 µm |
| Compliance | RoHS-compliant glass composition, ITU-T G.652.D compatible geometry |
| Customization | PM (Panda or Bowtie) and non-PM versions available |
| Manufacturing Origin | Taizhou, Zhejiang, China |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SKP5050 |
| Component Category | Optical Component |
| Spatial Resolution (Scanning Stage) | <317.5 nm |
| Work Function Resolution | <3 meV |
| Sample Size Range | 5–300 mm |
| Brand | Keopsys |
|---|---|
| Origin | France |
| Model | PUFL |
| Wavelength | 355 nm |
| Output Type | Free-space, collimated beam |
| Pulse Energy | up to 1.6 µJ |
| Peak Power | up to 1.6 kW |
| Average Power | up to 80 mW |
| Repetition Rate | 50 kHz |
| Beam Quality (M²) | < 1.3 |
| Power Consumption | Low |
| Package | Compact and rugged |
| Application Fields | Aerosol detection, fluorescence excitation, Raman spectroscopy, biological experimentation, wafer inspection |