| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MFS350 |
| Temperature Range | −195 °C to 350 °C |
| Sample Width | 0.001–22 mm |
| Sample Thickness | 0.001–2 mm |
| Minimum Sample Length | 26 mm |
| Tensile Speed | 1–5000 µm/s |
| Force Range | 0.01–20 N or 0.1–200 N |
| Force Resolution | 0.01 N or 0.1 N |
| Maximum Travel | 85 mm |
| Position Resolution | 1 µm |
| Objective Working Distance | 7.5 mm |
| Condenser Working Distance | 12.5 mm |
| Temperature Ramp Rate | 0.1–60 °C/min |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | PE100 |
| Temperature Range | −5 °C to 99 °C |
| Ramp Rate | ±10 °C/min |
| Temperature Accuracy & Stability | ±0.1 °C (full range) |
| Viewing Aperture Diameter | 16 mm |
| Sample Area Diameter | 108 mm |
| Minimum Objective Working Distance | 0.1 mm |
| Heating Element | Pt100-resistive |
| Control Interface | Integrated LCD touchscreen |
| Power Supply | DC |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | PE120 |
| Temperature Range | −25 °C to +120 °C |
| Heating/Cooling Rate | 0.1–20 °C/min |
| Stage Aperture Diameter | 5 mm |
| Sample Area | 35 × 32 mm |
| Temperature Stability & Accuracy | ±0.1 °C |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Control Interface | LCD Touchscreen |
| Minimum Objective Working Distance | 0.1 mm |
| Minimum Condenser Working Distance | 5 mm |
| Stage Dimensions (PE120XY) | 160 × 110 mm |
| Cooling Method | External Recirculating Chiller (ECP Series) |
| Compatibility | Olympus BX, Nikon Ni-E/Ni-U, Zeiss Axio Imager/Axioskop with Optional Mount Adapters |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS600 |
| Temperature Range | –196 °C to +600 °C |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Temperature Stability | <0.01 °C |
| Temperature Accuracy | ±0.1 °C (full range) |
| Sample Area Diameter | 22 mm |
| Optical Aperture Diameter | 2.0 mm |
| X/Y Translation Range | 16 mm each axis |
| Upper Window Thickness | 0.17 mm (coverslip-grade fused silica) |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Dimensions (Stage Body) | 160 × 80 × 24 mm |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | THMS600 |
| Price Range | USD 1,400 – 4,200 |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSE600 |
| Temperature Range | −196 °C to +600 °C (−196 °C requires optional liquid nitrogen cooling system) |
| Temperature Stability | < 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Optical Aperture Diameter | 2.4 mm |
| Sample XY Translation Range | 15 × 15 mm |
| Sample Area | 22 mm diameter |
| Electrode Configuration | Standard dual-electrode |
| Electrode Integration | Embedded in sealed chamber, compatible with conductive glass LC cells |
| Chamber Environment Control | Vacuum, inert gas (N₂, Ar), or humidity-controlled atmosphere |
| Window Thickness | 0.17 mm |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Stage Dimensions | 137 × 92 × 22 mm |
| Compatible Sample Format | 16 mm diameter cover slips with capillary-filled LC cells (5 µm cell gap) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSG600 |
| Temperature Range | −195 °C to +600 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Stability | <0.01 °C |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample XY Travel | 16 mm |
| Heating Area Diameter | 22 mm |
| Window Thickness | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Linkam THMSG600 |
| Price Range | USD 1,350 – 4,050 (FOB) |
| Temperature Range | −196 °C to +600 °C |
| Temperature Stability | < 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Optical Aperture Diameter | 1.3 mm |
| X–Y Sample Translation Range | 16 mm |
| Heating Zone Diameter | 22 mm |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Window Thickness (Cover Slip) | 0.17 mm |
| Minimum Working Distance (Objective/Condenser) | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1200 |
| Temperature Range | Ambient to 1200 °C |
| Temperature Accuracy & Stability | ±1 °C |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | Ø10 × 5 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Key | Brand: Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1400XY |
| Temperature Range | Ambient to 1400 °C |
| Heating Rate | 1–200 °C/min |
| Temperature Stability | ±1 °C |
| XY Translation Range | X = 4 mm, Y = 10 mm |
| Thermocouple Type | S-type (Pt-10% Rh / Pt) |
| Maximum Sample Size | 5 × 5 × 0.5 mm |
| Minimum Objective Working Distance | 6 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Optical Aperture | 1.7 mm |
| Gas-Tight Chamber | Yes |
| Cooling | Dedicated Water-Circulation System |
| Dynamic Thermal Response | Fast heating and cooling with real-time control |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1500 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy & Stability | ±1 °C over full range |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | φ7 × 6 mm or φ7 × 3 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Vacuum Compatibility | Down to 10⁻³ mbar |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Linkam TST350 |
| Price Range | USD 1,400 – 4,200 |
| Temperature Range | −196 °C to +350 °C |
| Sample Width | 0.001–22 mm |
| Sample Thickness | 0.001–2 mm |
| Minimum Sample Length | 26 mm |
| Extension Speed | 1–1000 µm/s |
| Force Range | 0.01–20 N or 0.1–200 N |
| Force Resolution | 0.01 N or 0.1 N |
| Maximum Travel | 80 mm |
| Position Resolution | 10 µm |
| Objective Working Distance | 7.5 mm |
| Condenser Working Distance | 12.5 mm |
| Temperature Ramp Rate | 0.01–30 °C/min |
| Brand | Linos |
|---|---|
| Origin | Germany |
| Type | Manual & Motorized Precision Angular Positioning Stage |
| Load Capacity | High |
| Translation Range | 5–40 mm (X/Y/Z configurable) |
| Angular Range | ±3° (Pitch), 360° Continuous Rotation (Rotational Stage) |
| Sensitivity | 3 arcseconds |
| Construction | Anodized Black Hard-Anodized Aluminum |
| Compliance | Designed for ISO/IEC 17025-aligned optical alignment workflows |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cage Series (Microbench / Nanobench / Tube C) |
| Pricing | Available Upon Request |
| Brand | Linos |
|---|---|
| Origin | Germany |
| Model | Linear Translation Stage |
| Travel Range | 5–40 mm |
| Load Capacity | High |
| Construction | Anodized Aluminum (Matte Black, Scratch-Resistant) |
| Adjustment Type | Manual (Micrometer-Driven) |
| Mounting Compatibility | X-Y, X-Y-Z Stackable Configuration |
| Tilt Range (for optional tilt stage) | ±3° |
| Tilt Sensitivity | 3 arcseconds |
| Rotation Stage Option | 360° Graduated, Lockable, Dual-Range (Coarse + Fine) Adjustment |
| Surface Finish | Hard-Anodized Aluminum |
| Brand | Linos |
|---|---|
| Origin | Germany |
| Model | Microbench |
| Platform Type | Cage-System Optical Breadboard |
| Construction | Anodized Aluminum Alloy |
| Surface Flatness | ≤±1.5 µm over 100 mm |
| Mounting Hole Pattern | Standard M4 and M6 threaded holes on 25 mm grid |
| Load Capacity | ≥5 kg uniformly distributed |
| Thermal Stability | Coefficient of Linear Expansion ≤23.6 × 10⁻⁶ K⁻¹ |
| Compatibility | Fully interoperable with Linos Nanobench, Tube C, and standard 30 mm cage systems |