| Brand | LEJ |
|---|---|
| Origin | Germany |
| Model | LQ-HXP 120 |
| Lamp Lifetime | 2,000 h |
| Cooling | Active Airflow System |
| Dimming | 5-Step Mechanical (0–100%) |
| Shutter Response Time | ~6 ms |
| Control Interface | Front Panel Switch, TTL Remote Input, CAN-BUS |
| Optical Coupling | Liquid Light Guide (Multi-Pin Connector) |
| Available Spectral Versions | VIS, UV |
| Brand | LIEKKI |
|---|---|
| Core/Cladding Diameter | 8/125 µm |
| Numerical Aperture (NA) | 0.12 |
| Peak Absorption @ 1530 nm | 16 dB/m |
| Cutoff Wavelength | 1450 ± 100 nm |
| Mode Field Diameter @ 1550 nm | ~10.5 µm |
| Background Loss @ 1200 nm | < 10 dB/km |
| Coating Diameter | 245 ± 10 µm |
| Proof Test Level | 100 kpsi |
| Operating Temperature | −40 to +85 °C |
| Compliance | Telcordia GR-20-CORE, IEC 60793-2-50 |
| Brand | Microphotons |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | Passive-14/250DC |
| Pricing | Upon Request |
| Brand | LIEKKI® |
|---|---|
| Core Diameter | 10 µm |
| Cladding Diameter | 125 µm |
| Numerical Aperture (Pump Cladding) | 0.46 |
| Numerical Aperture (Core) | 0.07 |
| Cutoff Wavelength | 975 ± 30 nm |
| Polarization Extinction Ratio (PER) | ≥20 dB/10 m |
| Pump Absorption @ 915 nm | 1.2 ± 0.2 dB/m |
| Pump Absorption @ 976 nm | 2.5 ± 0.3 dB/m |
| Coating Diameter | 245 ± 10 µm |
| Proof Test Level | 100 kpsi |
| Operating Temperature | −40 °C to +85 °C |
| Brand | Lightsmyth |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | SNS-C Series |
| Price Range | USD 5,400 – 13,500 (FOB) |
| Substrate Material | Single-Crystal Silicon |
| Fabrication Method | Reactive Ion Etching (RIE) |
| Surface Profile | Slightly Trapezoidal (Straight Parallel Ridges and Grooves) |
| Period Accuracy | < ±0.5% |
| Depth & Feature Width Tolerance | ±15% of Target |
| Optional Coating | Metallic (Au, Al, Cr) or Dielectric (SiO₂, Ta₂O₅, HfO₂) |
| Standard Thickness | 0.675 ± 0.050 mm |
| Clear Aperture (CA) | Offset 0.5 mm from Edge (Pattern Extends to Edge Upon Request) |
| CA Surface Quality | 60/40 (Standard), 20/10 (Optional “-P” Grade), 80/100 (Research-Grade “-S”) |
| Brand | Lightsmyth |
|---|---|
| Origin | USA |
| Model | T-1000 |
| Wavelength Range | 1525–1565 nm |
| Groove Density | 1000.00 lines/mm |
| Design Incidence Angle | 50.6° ± 1° |
| Peak Diffraction Efficiency | ≥93% (averaged over s- and p-polarizations) |
| Polarization-Dependent Loss (PDL) | <0.25 dB |
| Substrate Material | Fused Silica |
| Certification | Telcordia GR-1221-CORE compliant |
| Manufacturing | Wafer-scale lithographic replication of master gratings |
| Surface Scatter | Ultra-low (RMS < 0.1 nm) |
| Line Uniformity | <0.001 lines/mm |
| Brand | Microphotons |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Optical Component |
| Model | LIM-1060-10G-PM-PM |
| Operating Wavelength Range | 600–2000 nm (customizable) |
| Modulation Bandwidth | 10 GHz (optional 20 GHz / 40 GHz variants available) |
| Input/Output Fiber Type | Polarization-Maintaining (PM) Fiber |
| Electro-Optic Material | Z-cut Lithium Niobate (LiNbO₃) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | BCS196 |
| Temperature Range | –196 °C to +125 °C |
| Temperature Stability & Accuracy | ±0.01 °C |
| Optical Aperture Diameter | 1.3 mm |
| Sample X–Y Travel | 16 mm |
| Active Sample Area | 22 mm |
| Quenching Rate | Up to 5000 °C/min |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Window Thickness | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.7 mm |
| Dimensions | 135 × 92 × 22.1 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CAP500 |
| Temperature Range | −180 °C to +500 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | <0.1 °C |
| Heating/Cooling Rate | 1–50 °C/min |
| Sample X-Axis Translation | 20 mm |
| Quartz Window Aperture | 22 mm long × 1.6 mm diameter groove for capillary insertion |
| Minimum Working Distance | Objective 4.5 mm / Condenser 12.5 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CCR1000 |
| Temperature Range | Ambient to 1000 °C |
| Heating Rate | 1–130 °C/min |
| Temperature Stability | ±1 °C |
| Maximum Pressure | 5 bar (with quartz window) |
| Sample Diameter | 7 mm |
| Sample Mass | 70–100 mg |
| Gas Inlet | 1/16″ stainless steel high-pressure tubing |
| Working Distance for Objective Lens | 6 mm |
| Window Compatibility | Reflectance microscopy, Raman spectroscopy, FTIR |
| Cooling | Integrated water-cooled jacket |
| Construction Materials | Non-reactive ceramics, inert ceramic fiber filter, quartz or sapphire optical windows |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CMS196 |
| Temperature Range | Ambient to −196 °C |
| EM Grid Compatibility | Standard TEM grids, Bessy, Planchette, FEI, Polara formats |
| Motorized XY Stage Resolution | 1 µm |
| Integrated Condenser | For transmitted light and phase contrast |
| LN₂ Hold Time | 30 min (standard Dewar) / 6 h (optional 3 L Dewar) |
| Startup Time | ≤10 min |
| Sample Drift | <1 nm over 10 min |
| Stage Architecture | Decoupled sample holder–Dewar mechanical interface |
| Automation | Magnetic sample cartridge auto-alignment system (up to 3 samples) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | CSS450 |
| Temperature Range | −50 °C to 450 °C |
| Temperature Accuracy & Stability | ±0.1 °C |
| Optical Aperture Diameter | 2.5 mm |
| Sample Heating Area | 30 mm |
| Max. Heating/Cooling Rate | 30 °C/min |
| Minimum Objective/Condenser Working Distance | 7.4 mm / 11.5 mm |
| Shear Modes | Oscillatory, Steady, Step |
| Shear Rate Range | 0.003–7500 s⁻¹ |
| Gap Control Range | 5–2500 µm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FTIR600 |
| Temperature Range | −196 °C to 600 °C |
| Temperature Stability | < 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Optical Aperture Diameter | 2.4 mm |
| Sample X–Y Translation Range | 16 mm |
| Heating Area | 22 mm² |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Window Thickness (CaF₂) | 0.17 mm |
| Condenser Angle | 85° |
| Objective Angle | 116° |
| Minimum Working Distance (Objective/Condenser) | 4.5 mm / 12.5 mm |
| Chamber | Sealed, Gas-Purged Compatible |
| Dimensions (L×W×H) | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420 |
| Temperature Range | −196 °C to 420 °C (liquid nitrogen cooling optional) |
| Temperature Stability | < 0.1 °C |
| Max Ramp Rate | 0.1–50 °C/min |
| Sample Area | 53.5 × 43 mm |
| XY Translation | 15 × 15 mm |
| Optical Aperture | 2.5 mm |
| Minimum Objective Working Distance | 6 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Dimensions (Stage Only) | 160 × 80 × 24 mm |
| Key | Temperature Range: -180 °C to +500 °C |
|---|---|
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | <0.1 °C |
| Heating/Cooling Rate | 1–50 °C/min |
| Sample Slot Length | 22 mm |
| Slot Diameter | 1.6 mm |
| X-Axis Translation Range | 20 mm |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Quartz Optical Window | Standard |
| Pressure Sensor Integration | Optional (for pressurized capillary cells) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTSE420 |
| Temperature Range | Ambient to +420 °C (with optional cryo-cooling: down to −196 °C) |
| Temperature Stability | <0.01 °C |
| Temperature Resolution | 0.01 °C |
| Electrode Configuration | Standard dual-electrode |
| Optical Aperture | Ø2.4 mm |
| Sample XY Translation | 15 × 15 mm |
| Stage Surface Area | 53.5 × 43 mm |
| Compatible Sample Holders | Standard 76 × 26 mm microscope slides or Ø16 mm coverslips |
| Heating Rate | 0.1–50 °C/min |
| Minimum Objective Working Distance | 6.0 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Stage Dimensions | 160 × 80 × 24 mm |