| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Helios-LL Series |
| Light Source Type | Tungsten-Halogen |
| CCT | 2856 K ±50 K |
| Spectral Distribution | Blackbody-like |
| Integrating Sphere Coating | Spectraflect or Spectralon |
| Output Port Diameter | 2–8 in (0.05–0.2 m) |
| Sphere Diameter | 7.5–20 in (0.19–0.5 m) |
| Max Luminance | 1,600–9,500 cd/m² |
| Illuminance at Port | 5,000–30,000 lux |
| Dynamic Range | 4.00E+09 to 1.00E+10 (31–32 bits, 196–199 dB) |
| Angular Uniformity (FOV ±35°) | ±2.0% |
| Attenuation System | Advanced Variable Attenuator (VAA), 6.00E+06 to 8.80E+06 steps |
| Detector Configuration | Dual Silicon Detectors (SD-S1 & SD-L1) |
| Software Interface | HELIOSense GUI with LSAPI support |
| Compliance | MIL-STD-810G, ISO/IEC 17025 traceable calibration options available |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Helios-Plus AMA |
| Light Source Type | Xenon Arc Lamp |
| Illumination Mode | Internal Illumination |
| CCT Range | 3000 K to 6000 K |
| Spectral Range (Standard) | 350–1000 nm |
| Spectral Range (UV-Optimized) | 200–850 nm |
| Opening Diameter | 4 in or 8 in |
| Max Luminance | Up to 47,300 cd/m² |
| Opening Illuminance | Up to 182,000 lux |
| Field of View Uniformity | ±2.0% over 35° |
| Attenuation Options | Advanced Variable Attenuator (VAA), Dynamic Variable Attenuator (VAD), Manual Micrometer Attenuator (VA-MM) |
| Attenuator Resolution | Up to 2.00E+06 steps |
| Dynamic Range | Up to 152 dB |
| Integrated Spectroradiometer | Yes |
| Calibration Traceability | NIST-traceable |
| Compliance | ASTM E927, ISO 9050, MIL-STD-810G (optical testing), USP <1059>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | Labsphere |
|---|---|
| Model | Helios-V Series |
| Origin | USA |
| Light Source Type | Tungsten-Halogen (3000K Blackbody Simulated) |
| Integrating Sphere Diameter | 12 in |
| Output Port Diameter | 4 in (0.1 m) |
| Luminance Range | 0.001–11,500 cd/m² |
| Illuminance at Port | Up to 36,000 lux |
| CCT | 3000K ±50K |
| Spectral Range | 300–2400 nm |
| Uniformity (FOV 35°) | ±2.0% |
| Attenuation Method | Manual VA-MM or Dynamic VAD |
| Attenuator Steps | 1.00E+04 (NMNN) / 1.20E+04 (NDNN) |
| Dynamic Range | 5.00E+04 (93 dB, 16-bit) / 1.20E+04 (81 dB, 14-bit) |
| Internal Coating | Spectraflect® |
| Compliance | ASTM E308, ISO/CIE 11664, NIST-traceable calibration options available |
| Software Interface | HELIOSense™ via Labsphere LSAPI |
| Brand | Labsphere |
|---|---|
| Model | HLMS-200P |
| Origin | USA |
| Instrument Type | Handheld Photometer |
| Photometric Range | 0.5–7000 lm |
| Calibration Traceability | NIST-traceable |
| Spectral Correction | Yes |
| Auto-ranging | Yes |
| Auto-zero | Yes |
| Display | 4-digit LCD |
| Power Supply | 9 V battery |
| Auto-power-off | Yes |
| Low-battery Indicator | Yes |
| Weight | Lightweight, ergonomic handheld design |
| Compliance | Designed for photometric compliance with CIE 1931 standard observer and ISO/CIE 8981, IES LM-79–2019 (where applicable) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | Illumia Pro LED |
| Component Category | Optical Instrument System |
| Sphere Sizes Available | 0.5 m, 1.0 m, 1.65 m, 2.0 m |
| Measurement Geometries | 2π and 4π |
| Compliant Standards | IESNA LM-79, IESNA LM-80 |
| Software | Illumia Pro Measurement & Analysis Suite |
| Thermal Control | Integrated TEC stage with real-time temperature monitoring |
| Electrical Source | Precision programmable current source |
| Spectral Instrument | High-resolution CCD-based spectrometer |
| Accessories | Calibration lamps, auxiliary reference sources, environmental chamber option (optional) |
| Brand | Labsphere |
|---|---|
| Model | Infragold |
| Origin | USA |
| Component Type | Optical Element |
| Coating | Infragold® (700 nm – 20 µm) |
| Cooling | Water-cooled (max. 2 kW/cm² power density) |
| Detector Ports | 2 fixed, expandable to 4 |
| Compliance | ASTM E275, ISO 9001-certified manufacturing |
| Optional Configurations | Dual-detector, spectrometer-coupled, polarizer-filtered attenuation |
| Brand | Labsphere |
|---|---|
| Model | LFFP-200-N |
| Origin | USA |
| Light Source Type | Tunable White LED Array |
| Color Temperature Range | 3000 K – 6000 K (continuously adjustable) |
| Luminance Range | 100 – 15,000 cd/m² (nit) |
| Active Emitting Area | 200 mm × 200 mm |
| Spatial Uniformity | ≥95% across active area |
| Control Interface | SDK available for C/C++, Python, LabVIEW, and .NET (English, Chinese, Japanese localizations supported) |
| Compliance | CE, RoHS, FCC Class A |
| Brand | LabSphere |
|---|---|
| Model | LFUSS |
| Coating | Spectraflect® or Spectralon® |
| Internal Diameter Options | 15 cm – 200 cm |
| Spectral Range | 350–2500 nm |
| Calibrated Radiance Range | 0–40,000 nit |
| Uniformity | ≥98% |
| Stability | ±0.1% |
| Light Source Type | Tungsten-halogen (150 W external + multiple internal options: 35/75/100/150 W) |
| Illumination Method | Internal illumination |
| Motorized Attenuator | ≥35,000 steps |
| Calibration Traceability | NIST and NIM (China National Institute of Metrology) |
| Operating Temperature | 20–40 °C |
| Detector Type | Silicon photodiode |
| Validated Spectral Calibration Range | 360–1100 nm |
| Color Temperature | 2856 ± 50 K |
| Aperture Configurations | Dual detector ports + variable source access ports |
| Software Compatibility | LabSphere Uniform Source Measurement Software (customizable) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LPM |
| Coating | Infragold (700 nm – 20 µm) |
| Max Incident Power Density | 2 kW/cm² @ 10.6 µm (CW) |
| Cooling | Water-cooled (NPT 0.25", max 15 psi operating, 35 psi safety relief) |
| Detector Ports | Two standard SMA or flanged ports |
| Spectral Range | UV–Vis–NIR–MIR (compatible with Labsphere calibrated detectors) |
| Target Plate | Integrated energy-diffusing plate |
| Compliance | ASTM E275, ISO/IEC 17025-aligned calibration traceability, GLP-ready documentation support |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LS-LED-Production |
| Uniformity (Exit Port) | ≥98% |
| Exit Port Diameter | 45 mm |
| CCT Tuning Range | Adjustable Continuous from Warm to Cool White (Typ. 2700 K – 6500 K) |
| Illuminance Tuning Range | Continuously Adjustable (0–10,000 lx typical at port) |
| Control Resolution | Millisecond-level Setpoint Response |
| Power Supply | Integrated Multi-channel Constant-Current LED Drivers |
| Monitoring | Real-time Photometric Feedback (Illuminance, LED Forward Voltage/Current Decay) |
| Compliance | Designed for ISO/IEC 17025-compliant calibration workflows |
| Optional Add-on | Spectral Monitoring Module (VIS, 380–780 nm) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | LSA 3000 |
| Component Category | Optical Instrument System |
| Compliance | ASTM E2617, CIE S 025/E:2015, IES LM-79-19 (spatial extension), ISO/CIE 13370 |
| Software Integration | Labsphere TeraLED™ v5.0+ |
| Motion Control | Dual-axis goniometric stage (θ: ±90°, φ: 0–360°) |
| Angular Resolution | Adjustable from 0.1° to 5.0° |
| Detector | Calibrated silicon photodiode + optional integrated spectroradiometer (e.g., CAS 140D or I2000) |
| Measurement Modes | Absolute radiant intensity (W/sr), luminous intensity (cd), spectral radiant intensity (W/sr/nm), chromaticity (CIE 1931 x,y), CCT, CRI/Rf, Rg |
| Data Output Format | IESNA LM-63, EULUMDAT (.ldt), CSV, XML |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LSS |
| Component Category | Light Source |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | PT-038-PLS |
| Light Source Type | Tungsten-Halogen (Standard Configuration) |
| Spectral Range | 380–1000 nm (Typical) |
| Luminance Range | 0.1–10,000 cd/m² (Adjustable via Precision Attenuation) |
| Uniformity | ≤ ±0.5% over Central 80% Area |
| Stability | ≤ ±0.2% over 30 min (Thermally Stabilized) |
| Portability | Integrated Battery Option (Optional), < 8 kg |
| Compliance | NIST-Traceable Calibration Certificate Included |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Model | RT-060-SF |
| Coating | Spectraflect® |
| Spectral Range | 250–2500 nm |
| Sphere Diameter | 6 inches |
| Detector Port | 0.5 inch |
| Sample/Reference Ports | Five 1-inch ports |
| Mirror Trap | Included |
| Mounting | 1/4-20 threaded stud with adjustable rod-and-base stand |
| Compliance | ASTM E1331, ISO 9050, CIE S 014, USP <857> (for optical characterization) |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPECTRA-CT |
| Light Source Type | Tunable Broadband LED-Based Integrating Sphere Source |
| Illumination Method | Internal Illumination |
| Key Dimensions (CT-1000-S / M / L) | 20/30/50 cm sphere diameter |
| Output Aperture | 5/10/20 cm |
| Spectral Range | UV-Vis-NIR (250–1700 nm) |
| Luminance Range | 0.1–500,000 cd/m² (model-dependent) |
| Uniformity | >99% (per EMVA 1288 Annex A) |
| Color Temperature Range | 2800–7500 K |
| CCT Uniformity | ±15 K |
| Short-Term Stability | ±0.1% over 10 min |
| Warm-up Time | ≤30 s |
| Monitoring Sensor | Integrated Silicon Photodiode |
| Control Interface | USB + Ethernet |
| Software SDK | Yes (C/C++, Python, LabVIEW compatible) |
| Compliance | Fully supports EMVA 1288:2016 for camera characterization |
| Brand | Labsphere |
|---|---|
| Model | Spectra-FT |
| Origin | USA |
| Light Source Type | Tungsten-Halogen & LED Hybrid Spectral Engine |
| Spectral Range | 390–1000 nm |
| Luminance Range | 10–25,000 cd/m² |
| Field Uniformity | >98% over 360° × 200° FOV |
| Calibration Traceability | NIST-traceable spectral radiance |
| Feedback System | Integrated spectroradiometric real-time feedback loop |
| Re-calibration | User-executable via SpectraSoft™ v4.2 |
| Compliance | ASTM E308, ISO/CIE 11664, USP <1033>, FDA 21 CFR Part 11 (audit trail enabled) |