| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-SPMZ |
| Product Type | Motorized Translation Stage |
| Motion Range (Coarse) | 25 mm |
| Coarse Step Size | 95 nm |
| Encoder Resolution (Optional) | 20 nm |
| Nanopositioning Range | 30 µm |
| Nanopositioning Resolution | 0.06 nm |
| Resonant Frequency (Unloaded) | 4 kHz ±20% |
| Resonant Frequency (100 g Load) | 2 kHz ±20% |
| Stiffness | 3.0 N/µm ±20% |
| Max Horizontal Load | 1.0 kg |
| Max Vertical Load | 0.5 kg |
| Body Material | Aluminum |
| Controller | MicroDrive® + Nano-Drive® |
| Interface | Bidirectional USB |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-T Series |
| Product Type | Motorized Nanopositioning Stage |
| Motion Axes | 2-Axis (XY) or 3-Axis (XYZ) |
| XY Travel Range | 100 μm / 200 μm |
| Z Travel Range | 20 μm / 50 μm |
| XY Resolution | 0.2 nm / 0.4 nm |
| Z Resolution | 0.04 nm / 0.1 nm |
| Closed-Loop Positioning Accuracy | Picometer-Level |
| Aperture | Large Central Opening for Optical Components |
| Control Architecture | Integrated PicoQ® Capacitive Sensing |
| Body Material | Aluminum or Invar |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.2 kg |
| Resonant Frequency (X) | 450 Hz / 400 Hz ±20% |
| Resonant Frequency (Y) | 250 Hz / 200 Hz ±20% |
| Resonant Frequency (Z) | 450 Hz / 350 Hz ±20% |
| Angular Deviation (Roll/Pitch) | ≤1 μrad |
| Angular Deviation (Yaw) | ≤3 μrad |
| Compatible Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Theta |
| Product Type | Motorized Rotational Translation Stage |
| Motion Range | 2.0 mrad |
| Resolution | 4 nrad |
| Resonant Frequency (unloaded) | 2.0 kHz ±20% |
| Body Material | Aluminum or Invar |
| Control Architecture | Closed-loop with integrated PicoQ® position sensing |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Theta/H |
| Product Type | Motorized Rotational Positioning Stage |
| Motion Range | ±2.5 mrad (total 5 mrad) |
| Resolution | 10 nrad |
| Repeatability | <20 nrad |
| Resonant Frequency (unloaded) | 300 Hz ±20% |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.2 kg |
| Body Materials | Aluminum, Invar, or Titanium |
| Control | Closed-loop via integrated PicoQ® capacitive sensors |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-UHV100 |
| Product Type | Motorized Translation Stage |
| Motion Range (X/Y) | 100 µm × 100 µm |
| Resolution (XY) | 0.2 nm |
| Resonant Frequency (X) | 500 Hz ±20% |
| Resonant Frequency (Y) | 250 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Angular Deviation (Roll/Pitch) | ≤1 µrad |
| Angular Deviation (Yaw) | ≤3 µrad |
| Max. Horizontal Load | 0.5 kg |
| Max. Vertical Load | 0.2 kg |
| Body Material | Invar or Titanium |
| Bakeout Temperature | 100 °C |
| Vacuum Compatibility | ≤10⁻¹⁰ Torr |
| Control | Closed-loop with PicoQ® position sensing |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | Canada |
| Model | Nano-UHV200 |
| Motion Range (X/Y/Z) | 200 µm × 200 µm × 200 µm |
| Resolution (XYZ) | 0.4 nm |
| Resonant Frequency (X) | 300 Hz ±20% |
| Resonant Frequency (Y) | 150 Hz ±20% |
| Resonant Frequency (Z) | 175 Hz ±20% |
| Stiffness | 2 N/µm |
| Angular Deviation (Roll/Pitch) | ≤1 µrad |
| Angular Deviation (Yaw) | ≤3 µrad |
| Max. Horizontal Load | 0.5 kg |
| Max. Vertical Load | 0.2 kg |
| Construction | Titanium & 316 Stainless Steel |
| UHV Compatibility | ≤1×10⁻¹⁰ Torr |
| Control | Closed-loop with PicoQ® absolute position sensing |
| Aperture | 2″ × 2″ center optical access |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-UHV50 |
| Motion Range (X/Y) | 50 µm × 50 µm |
| Resolution (XY) | 0.1 nm |
| Resonant Frequency (X) | 500 Hz ±20% |
| Resonant Frequency (Y) | 250 Hz ±20% |
| Stiffness | 0.5 N/µm |
| Angular Deviation (Roll/Pitch) | ≤1 µrad |
| Angular Deviation (Yaw) | ≤3 µrad |
| Max. Horizontal Load | 0.5 kg |
| Max. Vertical Load | 0.2 kg |
| Body Material | Invar or Titanium |
| Bakeout Temperature | 100 °C |
| UHV Compatibility | ≤1×10⁻¹⁰ Torr |
| Aperture | 25 mm (1 inch) |
| Position Sensing | PicoQ® closed-loop absolute sensing |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-View® Series |
| Type | Motorized Translation Stage with Integrated Piezoelectric Nanopositioners |
| Travel (Micropositioning) | 25 mm per axis (X/Y) |
| Travel (Nanopositioning) | up to 300 µm per axis (X/Y/Z) |
| Micropositioner Step Size | 95 nm |
| Micropositioner Repeatability | 50 nm |
| Encoder Resolution (optional) | 20 nm |
| Nanopositioner Resolution | 0.2–0.6 nm (depending on range) |
| Closed-Loop Positioning Accuracy | Picometer-level (PicoQ® sensor technology) |
| Stiffness | 1.0 N/µm |
| Angular Deviation (Roll/Pitch) | ≤1 µrad |
| Angular Deviation (Yaw) | ≤3 µrad |
| Max Horizontal Load | 0.5 kg |
| Body Materials | Aluminum, Invar, or Titanium |
| Controllers | Nano-Drive® (nanopositioning) + Micro-Drive™ (micropositioning), USB interface |
| Software Compatibility | LabVIEW-ready, includes native motion control routines |
| Microscope Compatibility | Olympus IX/IX2, Nikon TE2000/Ti, Leica DMI, Zeiss Axiovert/Axio Observer, MCL RM21™ Platform |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-YT500 |
| Motion Axis | Single-axis (X) |
| Travel Range | 500 µm |
| Resolution | 1.0 nm |
| Resonant Frequency | 150 Hz ±20% |
| Stiffness | 0.8 N/µm |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.1 kg |
| Guiding Mechanism | Monolithic Flexure |
| Sensor Technology | PicoQ® Absolute Position Sensing |
| Control Architecture | Closed-loop with Nano-Drive® Controller |
| Body Material | Aluminum |
| Cycle Life | >1,000,000 full-range cycles |
| Aperture | Central rectangular optical pass-through |
| Orientation Independence | Yes |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-Z Series |
| Product Type | Motorized Precision Translation Stage |
| Motion Axis | Single-Axis (Z) |
| Travel Range | 100 µm or 200 µm |
| Resolution | 0.2 nm (Nano-Z100) / 0.4 nm (Nano-Z200) |
| Resonant Frequency | 600 Hz ±20% (100 µm) / 450 Hz ±20% (200 µm) |
| Stiffness | 1.0 N/µm |
| Max Recommended Load (Horizontal) | 0.5 kg |
| Body Material | Aluminum or Invar |
| Control Mode | Closed-Loop with Integrated PicoQ® Position Sensing |
| Step Response Time | ≤4 ms (with Nano-Drive®85) |
| Aperture | 2.6" × 2.6" |
| Height | 0.8" |
| Software Compatibility | Nano-Control Suite, Third-Party LabVIEW/Python API Support |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Z50HS |
| Motion Range | 50 µm |
| Resolution | 0.1 nm |
| Resonant Frequency | 1000 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max. Horizontal Load | 200 g |
| Body Material | Aluminum |
| Controller | Nano-Drive®85 |
| Control Mode | Closed-loop with PicoQ® position sensing |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-ZL Series |
| Motion Range | 100 μm or 500 μm (Z-axis) |
| Position Resolution | 0.2 nm (Nano-ZL100) / 1 nm (Nano-ZL500) |
| Resonant Frequency | 250 Hz |
| Max. Horizontal Load | 0.5 kg |
| Body Material | Aluminum |
| Control | Closed-loop with integrated PicoQ® absolute position sensing |
| Software Compatibility | Nano-Drive® controller suite |
| Compliance | Designed for GLP-compliant optical microscopy workflows requiring traceable, reproducible Z-positioning |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-ZS Series |
| Product Type | Motorized Precision Translation Stage |
| Motion Axis | Single-Axis (Z) |
| Travel Range | 100 μm or 200 μm |
| Resolution | 0.2 nm (Nano-ZS100) / 0.4 nm (Nano-ZS200) |
| Resonant Frequency | 450 Hz (100 μm) / 250 Hz (200 μm) |
| Stiffness | 1.0 N/μm |
| Max Recommended Load (Horizontal) | 0.5 kg |
| Body Material | Aluminum or Invar |
| Control Mode | Closed-Loop |
| Sensor Technology | PicoQ® Absolute Position Sensing |
| Controller Compatibility | Nano-Drive® and Nano-Drive®85 |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nanopositioning and Micropositioning Accessories |
| Product Type | Motorized Translation Stage |
| Compatibility | Nano-BioS, Nano-LPS, Nano-Z500, Motorized MicroStage, Manual MicroStage-LT |
| Mounting Standards | RMS (Olympus/Zeiss/Leica), M25-0.75 (Nikon) |
| Rack Format | 2U (3.47 in height), Full-width & Half-width options |
| Control Interface | USB |
| Software | NanoControl & MicroControl (LabVIEW-based, Windows-compatible, free with USB-enabled systems) |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | OEM Nano-Drive® Series |
| Product Type | Motorized Translation Stage |
| Compliance | RoHS, CE (2004/108/EC, 2006/95/EC) |
| Power Input | 12 W @ 24 VDC |
| Amplifier Output Voltage Range | −20 V to +165 V |
| Continuous Power Output | 10 W |
| Max Continuous Drive Current | 50 mA |
| Feedback Sensor | PicoQ® capacitive position sensor |
| Control Loop | Proportional-Integral (PI) closed-loop servo |
| Analog Input | 0–10 V (configurable), BNC interface |
| Sensor Output | 0–10 V, BNC interface |
| USB Interface Option | 16-bit or 20-bit digital daughter board |
| Operating Temperature | 5–40 °C |
| Dimensions | 193.68 × 171.45 × 63.5 mm |
| Steady-State Power Consumption | <0.5 W |
| Input Impedance | 10 kΩ |
| Short-Circuit Protection | Yes |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | PZT1 / PZT2 / PZT3 / PZT4 |
| Actuator Type | Low-Voltage Multilayer Piezoelectric Actuator |
| Max. Displacement | 4.6–17.4 µm |
| Max. Driving Voltage | 150 VDC |
| Capacitance | 0.10–0.75 µF ±20% |
| Resonant Frequency | 69–276 kHz |
| Blocking Force | 200–850 N |
| Operating Temperature Range | −25 to +85 °C |
| Cross Section | 3.5×4.5 mm or 6.5×6.5 mm |
| Young’s Modulus | 4.4×10¹⁰ N/m² |
| Tensile Strength | 20–85 MPa |