X-ray Diffractometer
Filter
Showing 225–240 of 257 results
| Brand | Tongda |
|---|---|
| Origin | Liaoning, China |
| Model | TD-5000 |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Configuration | Floor-Standing |
| X-ray Source Power | 3 kW |
| 2θ Angular Repeatability | 0.0001° |
| Minimum Step Angle | 0.0001° |
| Temperature Control Range | 100 K – 300 K |
| Temperature Stability | ±0.3 K |
| Detector | PILATUS Hybrid Pixel Detector |
| Goniometer Architecture | Four-Circle Concentric Design |
| Data Acquisition Interface | Touchscreen-Controlled PLC System |
| Brand | EVDENT |
|---|---|
| Model | TERRA |
| Type | Benchtop Powder X-ray Diffractometer |
| Origin | USA |
| Instrument Class | XRD for Qualitative & Quantitative Phase Analysis |
| Compliance | ASTM E1420, ISO 17853, ICH Q5e (Phase Identity Verification), GLP-Ready Architecture |
| Detector | Large-Area Silicon Strip Detector (SSD) |
| X-ray Source | Sealed Cu-target Microfocus Tube (40 kV / 10 mA) |
| Angular Range | 5°–70° 2θ (step size: 0.02°) |
| Data Acquisition Time | < 5 min per scan (standard mode) |
| Software | TerraXRD v3.2 with Rietveld Refinement Engine, PDF-4+ Database Integration, CFR Part 11 Audit Trail Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ/θ |
| Angular Accuracy | ±0.002° |
| Detector | Solid-state 2D pixel detector (55 × 55 µm pixel pitch) |
| Sample Handling | Manual 1-position holder or optional 6-position autosampler |
| X-ray Source | Cu or Co sealed-tube anode |
| Cooling | Optional water-cooling system |
| Data Output | Automated LIMS integration |
| Compliance | IEC 61000-4, IEC 62471, EN 61000-6-3, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ARL X'TRA |
| Instrument Type | Powder X-ray Diffractometer |
| Power | Not Applicable (X-ray tube power not specified in source |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ARL EQUINOX 100 |
| Instrument Type | Powder X-ray Diffractometer |
| Detector | Position-Sensitive Detector (PSD) |
| 2θ Angular Range | >120° (simultaneous acquisition) |
| Angular Resolution | ≤0.05° 2θ |
| Minimum Acquisition Time | 1 second |
| Goniometer | Multi-axis precision goniometer |
| Beam Spot Size | Down to 10 μm |
| Optical Configuration | Monochromatic optics (Cu Kα, optional Co/Fe/Mo anodes) |
| Sample Environment Options | Variable-temperature stages, controlled-atmosphere chambers |
| Software Suite | Thermo Scientific™ EQUINOX Software (including qualitative/quantitative phase analysis, Rietveld refinement, crystallite size/strain, PDF analysis) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ARL EQUINOX 1000 |
| Instrument Type | Powder X-ray Diffractometer |
| Detector | Position-Sensitive Detector (PSD) |
| 2θ Angular Range | >120° (simultaneous acquisition) |
| Angular Resolution | ≤0.05° 2θ |
| Minimum Acquisition Time | 1 second |
| Goniometer | Multi-axis precision diffractometer |
| Beam Size | Down to 10 μm micro-diffraction capability |
| Optical Configuration | Monochromatic optics (Cu Kα standard, optional anode materials) |
| Sample Environment Options | Variable-temperature stages, controlled-atmosphere chambers |
| Software Suite | Thermo Scientific™ EQUINOX Software (including phase identification, quantitative Rietveld refinement, crystallite size/strain analysis, PDF database integration) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | France |
| Model | ARL EQUINOX 3000 |
| Instrument Type | Powder X-ray Diffractometer |
| Power | 0.0001 kW (0.1 W tube standby power) |
| Detector | CPS 120 real-time 1D detector |
| 2θ Range (asymmetric mode) | 0–120° |
| Detector Radius | 250 mm |
| Optical Options | Ge(111) monochromator, HOPG(002) monochromator, focusing/parallel multilayer optics |
| Sample Chamber | Large-volume, motorized sample stage compatible with in situ accessories |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ARL EQUINOX 3000 |
| Instrument Type | Powder X-ray Diffractometer |
| Detector | Position-Sensitive Detector (PSD) |
| 2θ Angular Range | >120° (simultaneous acquisition) |
| Angular Resolution | ≤0.05° 2θ |
| Minimum Acquisition Time | 1 second per pattern |
| Beam Spot Size | down to 10 µm (with multi-axis goniometer) |
| Optical Configuration | Monochromatic optics (Cu Kα, optional Co/Fe/Mo sources) |
| Sample Environment Options | Variable-temperature stages, controlled-atmosphere chambers, humidity cells |
| Software Suite | Thermo Scientific™ ARL™ EQUINOX Software (including Rietveld refinement, phase identification, quantitative analysis, crystallite size/strain modeling) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ARL EQUINOX 5000 |
| Instrument Type | Powder X-ray Diffractometer |
| Detector | Position-Sensitive Detector (PSD) |
| 2θ Angular Range | >120° (simultaneous acquisition) |
| Angular Resolution | ≤0.05° 2θ |
| Minimum Acquisition Time | 1 second |
| Goniometer | Multi-axis precision diffractometer |
| Microbeam Capability | Down to 10 μm |
| Monochromator | Fixed or variable monochromatic optics |
| Sample Environment Options | Temperature-controlled stages, atmospheric/gas-controlled chambers |
| Software Suite | Thermo Scientific™ EQUINOX Software (including Rietveld refinement, phase identification, crystallite size/strain analysis, quantitative phase analysis) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ARL EQUINOX 6000 |
| Instrument Type | Powder X-ray Diffractometer |
| Detector | Position-Sensitive Detector (PSD) |
| 2θ Angular Range | >120° (simultaneous acquisition) |
| Angular Resolution | ≤0.05° 2θ |
| Minimum Acquisition Time | 1 s per pattern |
| Beam Spot Size | down to 10 µm |
| Optical Configuration | Monochromated Cu Kα (or optional Co/Fe/Mo sources) |
| Goniometer | Four-circle Eulerian cradle (χ, φ, ω, 2θ) |
| Sample Environment Options | Variable-temperature stages, controlled-atmosphere chambers, vacuum-compatible sample holders |
| Software Platform | Thermo Scientific™ ARL™ EQUINOX Suite (including TOPAS, DIFFRAC.SUITE, and stress/texture analysis modules) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | ARL X'TRA Companion |
| Instrument Type | Benchtop Powder X-ray Diffractometer |
| Angular Accuracy | ±0.002° |
| Geometry | θ/θ Bragg–Brentano |
| Detector | Solid-state 2D pixel detector (55 × 55 µm pixel pitch) |
| Sample Handling | Manual 1-position holder or optional 6-position autosampler |
| X-ray Source | Cu or Co sealed-tube anode |
| Cooling | Optional water-cooling system |
| Data Output | LIMS-integrated reporting |
| Compliance | IEC 61000-4, FDA 21 CFR Part 11 ready, ISO 17025 compatible |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | RL EQUINOX Pro |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 3000 W, 4000 W |
| Compliance | CE, UL 61010-1, IEC 62471 (UV/IR/X-ray safety) |
| Detector Technology | PTPC (Pulse-Triggered Position-Correlated) photon counting |
| Goniometer Control | Distributed micro-stepping motor system with real-time positional feedback |
| Optical System | Modular “Magic Card” optical alignment architecture with dynamic mechanical error compensation |
| Software Platform | EQUINOX Suite v5.x (cross-platform: Windows, macOS, Linux) |
| Data Format Compatibility | CIF, .raw, .udf, .xrdml, .chi, .gda, .asc, ICDD PDF-4+ database native support |
| Brand | Thermo Fisher |
|---|---|
| Origin | France |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Model | ARL EQUINOX 100 |
| Power Stability | < 0.0001 (unitless relative stability, typical for high-stability X-ray tube power supply) |
| Detector | Integrated EQUINOX curved position-sensitive detector (CPSD) |
| Cooling | Fully integrated internal water-cooling system |
| Sample Handling | Optional 6-position autosampler, transmission powder holders, thin-film accessories |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ARL EQUINOX 100 |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Detector Geometry | Curved Position-Sensitive Detector (PSD) |
| Measurement Range | 0–110° 2θ (real-time, no scanning) |
| X-ray Source | Microfocus Cu Kα (sealed tube) |
| Cooling | Air-cooled, no external water required |
| Power Supply | Standard 100–240 V AC outlet |
| Footprint | ≤0.3× standard floor-standing XRD systems |
| Brand | Thermo Fisher |
|---|---|
| Origin | France |
| Model | ARL EQUINOX 3000 |
| Instrument Type | Powder X-ray Diffractometer |
| Detector | Curved Position-Sensitive Detector (PSD) |
| Operation Mode | Real-time Simultaneous Acquisition |
| Sample Chamber | Large-volume, Accessory-Compatible Cavity |
| Compliance | Designed for ISO/IEC 17025-compliant labs, compatible with GLP/GMP workflows requiring audit-ready data traceability |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Model | EQUINOX 3000 |
| Instrument Type | Powder X-ray Diffractometer |
| Detector | Curved Position-Sensitive Detector (PSD) |
| Power Supply | Standard 208–240 V AC, 50/60 Hz |
| Compliance | CE, IEC 61010-1, ISO 9001-certified manufacturing |