X-ray Diffractometer
Filter
Showing 209–224 of 257 results
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TFXRD-300/200 |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Form Factor | Benchtop |
| Application Focus | Near-Fab GaN Wafer Characterization & XRD Mapping |
| Optical Configurability | Modular Optics Selection Available |
| Compliance Context | Designed for ISO/IEC 17025-aligned QC labs and semiconductor fab-adjacent environments |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Ultima IV Series |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Generator Power | 3 kW |
| Goniometer | Horizontal Type |
| Minimum Angular Step | 0.0001° |
| Optical System | CBO Cross-Beam Optics (Patented) |
| Detector | D/teX-Ultra High-Speed Energy-Dispersive Detector |
| Optional Modules | In-Plane Geometry Unit, Small-Angle X-ray Scattering (SAXS) Module, Thin-Film Analysis Module, Micro-Beam Mapping Unit, XRD-DSC Simultaneous Measurement System |
| Software Suite | PDXL (with Rietveld), NANO-Solver, GXRR, and XRD Analysis Package |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Ultima IV Series |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Generator Power | 3 kW |
| Goniometer | Horizontal θ–θ configuration |
| Minimum Angular Step | 0.0001° (1/10,000°) |
| Goniometer Slit | Programmable Variable Aperture |
| Monochromator | High-efficiency Graphite Monochromator |
| Optics | CBO Cross-Beam Optics (patented Rigaku technology) enabling both focused-beam and high-intensity/high-resolution parallel-beam modes with mirror optics |
| Optional Modules | SAXS attachment, Thin-Film Analysis stage, Micro-Beam stage, In-Plane stage (Rigaku-exclusive) |
| Detector | D/teX-Ultra high-speed silicon strip detector |
| Integrated Hybrid System | XRD-DSC simultaneous measurement module |
| Software Suite | PDXL (XRD analysis), NANO-Solver (nanoscale scattering & particle size distribution), GXRR (grazing-incidence X-ray reflectivity) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Configuration | Floor-Standing |
| Detector | PILATUS200K Hybrid Pixel Array Detector |
| Detector Pixel Size | 172 µm |
| Dynamic Range | 1 × 10⁶ photons/pixel |
| Operating Temperature | Ambient (No Cryogenic Cooling Required) |
| X-ray Source Options | MicroMax003 (Cu or Mo), DualSource (Cu + Mo), MicroMax007HF, MicroMax007HF-DW, MultiMax9 |
| Goniometer Types | Partial χ, Fixed χ, Three-Axis AFC-Kappa, Four-Axis Kappa |
| Optional Accessories | Low-Temperature Device (e.g., Oxford Cryostream) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | XtaLAB Synergy |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Configuration | Floor-Standing |
| Power Stability | < 0.0001 (unitless, indicating angular reproducibility or beam stability per manufacturer specification) |
| Detector | HyPix-6000HE Photon-Counting Pixel Array Detector |
| Detector Active Area | 77.5 mm × 80.0 mm |
| Pixel Size | 100 µm × 100 µm |
| Cooling Method | Air-Cooled |
| Dynamic Range | Up to 31-bit equivalent |
| Readout Mode | Shutterless, 0-ms dead time |
| Goniometer | AFC-Kappa Four-Axis |
| X-ray Source Options | Microfocus Sealed-Tube (Cu/Mo), MM007HF Rotating Anode, FR-X High-Brilliance Rotating Anode |
| Anode Materials | Cu, Mo, or Dual Cu/Mo |
| Cryogenic Capability | Integrated Low-Temperature System (e.g., Oxford Instruments Cryostream-compatible) |
| Software Suite | CrysAlisPro (data collection & processing), AutoChem (automated structure solution and refinement) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | XtaLABmini |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Source | Mo Kα, 600 W high-frequency generator |
| Goniometer Axes | χ fixed at 54°, Φ rotation: −360° to +360° about sample center axis, ω range: 2θ ± 90° (−60° to +120°), 2θ fixed at 30° |
| Sample Viewing | 70× CCD microscope with 50 mm camera-to-sample distance |
| Detector | CCD, active area Φ75 mm, pixel sizes 73.2 µm / 146.4 µm, resolution modes 1024 × 1024 / 512 × 512, readout times 2.24 s / 0.56 s, dark current 0.1 e⁻/pixel/s |
| Optional | Cryogenic sample stage (e.g., Oxford Instruments Cryostream-compatible) |
| Brand | Ruishenbao |
|---|---|
| Model | CW-W |
| Type | Integrated Water-Cooled Circulating Chiller |
| Application | Cooling Support for X-ray Diffractometers (XRD) and Other High-Heat-Load Analytical Instruments |
| Origin | Tianjin, China |
| Cooling Capacity Range | 5–25 kW |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±0.1 °C to ±2 °C (model-dependent) |
| Flow Rate | 3–110 L/min |
| Refrigerant | R22 |
| Power Supply | AC 380 V, 3-phase, 50 Hz |
| Water Tank Volume | 35–140 L |
| Protection Features | Compressor overload, high/low pressure, anti-freeze, and delayed start protection |
| Compliance | Designed for laboratory integration per IEC 61000-6-3 (EMC), ISO 13849-1 (functional safety architecture), and GLP-compliant operational logging capability |
| Brand | Haoyuan |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DX-2700BH |
| Instrument Type | High-Resolution X-ray Diffractometer |
| Configuration | Floor-Standing |
| X-ray Generator Power | 3 kW |
| Angular Accuracy | ±0.001° |
| Angular Resolution | 0.03° |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | XRD-6100 |
| Instrument Type | Powder X-ray Diffractometer |
| Scan Geometry | θ/2θ |
| Monochromator | Focusing Bent-Crystal Monochromator |
| Typical X-ray Tube Power | 2.2 kW (Cu Kα) |
| X-ray Efficiency | >50% |
| Safety Compliance | IEC 61010-1, IEC 62471 (Radiation Safety Class 1) |
| Configuration | Benchtop, Fixed-Anode Cu Target Tube |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TK-201 |
| Price | USD 125,000 (FOB) |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Angular Resolution | 0.0001° |
| Angular Reproducibility | 0.0006° |
| Minimum Step Size | 0.0001° |
| Goniometer Radius | ≥150 mm |
| X-ray Source | Metal-Ceramic Cu Tube, 2.4 kW, Air/Water Cooled |
| Detector | MYTHEN 1D Photon-Counting Detector (Imported from Dectris, Switzerland) |
| Detector Performance | Zero noise, zero dark current, high dynamic range, linearity, and 150× intensity gain vs. scintillation counters |
| Beam Optics | Fixed Cu Kα, θ–θ geometry |
| Compliance | IEC 61000-6-3, IEC 61000-6-4, GB/T 18268.1–2010 (EMC), GBZ 128–2019 (Radiation Safety) |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Model | TK-333XRD |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Generator Max Power | 3000 W |
| Max Tube Voltage | 60 kV |
| Max Tube Current | 50 mA |
| Voltage/Current Stability | ±0.1% over 8 h |
| Angular Resolution | ω/θ = 0.0001°, κ/φ = 0.001° |
| Scan Speed Range | 0.005–3.0 °/s |
| Detector | DECTRIS PILATUS Hybrid Pixel Photon-Counting Detector |
| Cryostat Temperature Range | 120–400 K |
| Temperature Stability | ±0.1 K |
| Angular Accuracy | 0′11″ |
| Spatial Resolution (d-spacing) | 0.23 Å |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Model | TK-333 |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Configuration | Benchtop |
| Power Stability | ±0.1% (over 8 h) |
| Angular Accuracy | 0.11 arcsec |
| Angular Resolution | 0.03 arcsec |
| X-ray Source | Mo/Cu Metal-Ceramic Tube |
| Max. Output Power | 3000 W |
| Max. Voltage | 60 kV |
| Max. Current | 50 mA |
| Detector | DECTRIS PILATUS Hybrid Pixel Photon-Counting Detector |
| Goniometer | Kappa Four-Circle |
| Temperature Control Range (Cryo) | 120–400 K |
| Temp. Stability | ±0.1 K |
| Omega/Theta Resolution | 0.0001° |
| Kappa/Phi Resolution | 0.001° |
| Scan Speed | 0.005–3.0 °/s |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Model | TK-D-8 |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | θ–θ Vertical Goniometer |
| X-ray Source | Metal-Ceramic Cu Target Tube (2.4 kW, Air/Water Cooled) |
| Detector | MYTHEN 1D Photon-Counting Detector (Imported, Noise-Free, Dark-Current-Free) |
| Goniometer Radius | ≥150 mm |
| Angular Reproducibility | 0.0001° |
| Minimum Step Size | 0.0001° |
| Angular Accuracy | 0.001° |
| Resolution | 0.03° |
| Power Stability | ±0.0006° (drift over time) |
| Software | PDP Diffraction Data Processing Suite (Bilingual UI, ASTM E1421 & ISO 17873 Compliant Export Formats) |
| Compliance | GB/T 17029–2021, IEC 61000-6-3, FDA 21 CFR Part 11 Ready (Audit Trail Enabled) |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Model | TK-XRD-201 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Angular Resolution | 0.03° |
| Angular Accuracy | ±0.001° |
| Minimum Step Size | 0.0001° |
| Goniometer Reproducibility | ±0.0001° |
| Goniometer Precision (Repeatability) | ±0.0006° |
| X-ray Source | Metal-ceramic Cu anode tube, 2.4 kW, air- or water-cooled |
| Detector | MYTHEN1K single-photon-counting 1D strip detector (imported from Dectris, Switzerland) |
| Goniometer Radius | ≥150 mm |
| Radiation Shielding | Integrated lead-lined cabinet with motorized rotating shutter, external dose <1 µSv/h during operation |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Model | TK-XRD-201 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Tube Power | 2.4 kW |
| Angular Accuracy | ±0.001° |
| Angular Reproducibility | 0.0001° |
| Minimum Step Size | 0.0001° |
| Detector | MYTHEN1K 1D Photon-Counting Detector (Imported) |
| Goniometer Radius | ≥150 mm |
| X-ray Source | Metal-Ceramic Cu Target Tube |
| Cooling Options | Air or Water |
| Software | PDP Diffraction Data Processing Suite (Bilingual UI) |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Model | TK333 |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Instrument Configuration | Benchtop |
| Power Stability | ±0.1% (8 h) |
| Angular Accuracy | 0.1 arcsec |
| Resolution | 2.2 Å (Cu-Kα) |
| X-ray Source | Mo/Cu Metal-Ceramic Tube |
| Generator Max Output | 3000 W |
| Max Voltage | 60 kV |
| Max Current | 50 mA |
| Goniometer | Kappa Four-Circle |
| Detector | DECTRIS PILATUS Hybrid Pixel Photon-Counting Detector |
| Cryosystem Temperature Range | 120–400 K |
| Temp. Stability | ±0.1 K |
| Omega/Theta Resolution | 0.0001° |
| Kappa/Phi Resolution | 0.001° |
| Scan Speed | 0.005–3.0 °/s |