| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | IPX-LC |
| Pricing | Upon Request |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Source | Sealed Mo-target Tube |
| Maximum Power | 1600 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.1° |
| Goniometer Geometry | Vertical θ–2θ |
| Goniometer Radius | 144 mm |
| Angular Range | 0°–150° |
| Detector | Photon-counting 2D Array Detector |
| Sample Stage | Temperature-Controlled Pouch-Cell Holder (−30 °C to 300 °C) |
| Dimensions | 900 mm × 680 mm × 550 mm |
| Weight | 100 kg |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Lattice Series |
| Instrument Type | Powder X-ray Diffractometer |
| Instrument Configuration | Benchtop |
| X-ray Power | 1200 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.1° |
| Detector | 256 × 256 Pixel Photon-Counting 2D Array Detector |
| Goniometer Geometry | θ–2θ (Lattice Basic) or θ–θ (Lattice Pro) |
| X-ray Tube Anode Material | Cu or Co (sealed tube) |
| Angular Range | –3° to 156° (Z-axis tilt ≤ –20°), 0° to 160° (Z-axis tilt > –20°) |
| Goniometer Radius | 150–228 mm (adjustable) |
| Detector Energy Resolution | 0.2 keV |
| Dimensions | 900 mm × 680 mm × 550 mm |
| Weight | 100 kg |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Model | FRINGE C1600 |
| Regulatory Classification | Domestic (China) |
| Key Features | θ–2θ coupled goniometer with single-axis drive |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Model | FRINGE CLASS |
| Power Supply | As specified in technical documentation |
| Detector | Proportional Counter (≥500 kcps count rate) |
| Geometry | Bragg–Brentano θ–2θ reflection mode |
| Cooling System | Integrated water recirculation cooling |
| Compliance | CE-marked, compliant with IEC 61000-6-3 (EMC) and IEC 61000-6-4 (emission standards) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FRINGE D200 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Rating | kW-class (air-cooled or integrated water-cooling system) |
| Detector | Xeye2D 2D hybrid pixel array detector |
| Goniometer | High-precision vertical θ–θ configuration |
| Software | CrystalX automated phase analysis suite |
| Sample Compatibility | Powders, bulk solids, thin films, liquids |
| Safety | Interlocked sample chamber, automatic beam shutter, real-time door status feedback |
| Optional Accessories | High-temperature stage, cryo-stage, humidity-controlled cell |
| Compliance | Designed to meet IEC 61010-1 (safety), ISO 17025 operational readiness guidelines, and GLP-aligned data integrity practices |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg-Brentano θ–2θ reflection mode |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ counts per second (CPS) |
| Power | kW-class microfocus X-ray source (exact rating per configuration) |
| Compliance | CE-marked, IEC 61000-6-3/6-4, IEC 62471 (LED/X-ray safety) |
| Sample Handling | Motorized sample stage with integrated Soller collimator, air-spring assisted large-window hinged door |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ–2θ reflection |
| Detector | Digital Pulse Processing Counter (DPPC) |
| Maximum Count Rate | ≥1 × 10⁷ counts per second (CPS) |
| Sample Forms | Powders, bulk solids, thin films |
| Software | CrystalX™ automated phase identification & quantification suite |
| Compliance | Designed for GLP-compliant workflows |
| Safety | Interlocked sample chamber with auto-shutdown, real-time door status feedback, full enclosure during operation |
| Optical Path | Integrated fixed Soller slits, divergence slit, anti-scatter slit, receiving slit |
| Power Supply | High-voltage generator rated for kW-class operation (exact rating model-specific |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ–2θ reflection |
| Power Rating | kW-class (rated for continuous operation) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ counts per second (CPS) |
| Optical Configuration | Integrated Soller slits, fixed divergence slit, anti-scatter slit, receiving slit |
| Sample Stage | Motorized goniometer with precision angular encoder |
| Safety Compliance | Interlocked sample chamber, automatic beam shutter activation upon door opening, real-time chamber status feedback on GUI |
| Software Platform | CrystalX — automated phase identification, quantitative Rietveld refinement, crystallinity index calculation, PDF-4+ database integration |
| Regulatory Alignment | Designed to support GLP-compliant workflows |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg-Brentano θ–2θ Reflection |
| Detector | Digital Pulse Processing Counter (DPPC) |
| Count Rate Capacity | ≥1 × 10⁷ counts per second (CPS) |
| Sample Stage | Fixed-center goniometer with integrated Soller slits |
| Power Supply | kW-class microfocus X-ray source (exact rating specified in technical documentation) |
| Compliance | CE-marked for laboratory use |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | FRINGE EV |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | kW-class (integrated sealed X-ray tube) |
| Geometry | Bragg–Brentano reflection (θs–θd) |
| Detector | High-sensitivity scintillation or silicon-strip detector (configurable) |
| Sample Stage | Motorized goniometer with ±0.001° angular resolution |
| Software Platform | CrystalX v3.x (with ICDD PDF-4+ database integration) |
| Compliance | CE, RoHS, IEC 61000-6-3/6-4, EN 62471 (UV/soft X-ray safety) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | FRINGE EV |
| Instrument Type | Powder X-ray Diffractometer |
| Power | kW-class (rated for continuous operation in desktop configuration) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ counts per second (CPS) |
| Geometry | Bragg–Brentano θ–2θ reflection mode |
| Sample Stage | Motorized goniometer with fixed center-of-rotation |
| Slit System | Integrated Soller collimators (no moving adjustment parts) |
| Safety | Interlocked sample chamber with auto-shutdown, door-closed status indicator |
| Software | CrystalX — automated phase identification, quantitative Rietveld refinement, crystallinity index calculation, and EDS-enabled hybrid XRD/EDS data correlation |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | FRINGE EV Pharmaceutical Crystal Diffractometer |
| Instrument Type | Benchtop Powder X-ray Diffractometer |
| Power Rating | kW-class (rated for high-flux operation) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ cps count rate |
| Optical Configuration | Integrated fixed Soller collimator, θs–θd reflection geometry |
| Safety | Interlocked fully enclosed sample chamber with auto-shutdown, real-time door status feedback |
| Software | CrystalX — automated phase identification, quantitative Rietveld refinement, crystallinity index calculation, and EDS-enabled hybrid data acquisition |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FRINGE EV |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | kW-class (rated for continuous high-intensity operation) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ counts per second (CPS) |
| Optical Configuration | Integrated Soller collimator (fixed, no moving parts) |
| Geometry | Bragg–Brentano θ–2θ reflection mode |
| Safety | Interlocked sample chamber with automatic beam shutter, real-time door status feedback in GUI |
| Software | CrystalX — automated phase identification, quantitative Rietveld refinement, crystallinity index calculation, and energy-dispersive spectral overlay |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FRINGE EV |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | kW-class (air-cooled, sealed-tube source) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ cps |
| Optical Configuration | Integrated Soller slits, fixed divergence geometry |
| Sample Geometry | Bragg–Brentano θ–2θ reflection mode |
| Safety Compliance | Interlocked sample chamber with auto-shutdown, full enclosure when closed |
| Software | CrystalX — automated phase identification, quantitative Rietveld refinement, crystallinity index calculation, EDS-enabled hybrid XRD/EDS data acquisition |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FRINGE EV |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | kW-class (rated for continuous high-intensity operation) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ counts per second (CPS) |
| Optical Configuration | Integrated fixed Soller slits, θ–2θ reflection geometry |
| Safety Compliance | Interlocked sample chamber with automatic beam shutter, full enclosure when closed |
| Software | CrystalX — automated phase identification, quantitative Rietveld refinement, crystallinity calculation, and EDS-enabled hybrid data acquisition |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ–2θ reflection mode |
| Power Supply | kW-class integrated X-ray source (exact rating per configuration) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1 × 10⁷ counts per second (CPS) |
| Sample Stage | Fixed-height goniometer with air-spring assisted large-window lift door |
| Software | CrystalX™ automated phase identification & quantification suite |
| Compliance | Designed for GLP-compliant labs |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FRINGE EV |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | kW-class (typical operational range: 1.2–2.4 kW, configurable per application requirements) |
| Detector | DPPC (Digital Pulse Processing Counter Detector), Count Rate ≥ 1 × 10⁷ cps |
| Optical Configuration | Integrated fixed Soller slits, Bragg–Brentano θ–2θ reflection geometry |
| Safety Compliance | Interlocked sample chamber with automatic beam shutdown, real-time door status feedback in GUI |
| Software Platform | CrystalX™ v3.2+ with automated phase identification, Rietveld refinement, quantitative phase analysis (QPA), crystallinity index calculation, and alumina polymorph transformation ratio reporting (α-, γ-, δ-, θ-, κ-, χ-Al₂O₃) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg-Brentano θ–2θ reflection mode |
| Power | kW-class sealed-tube X-ray source (rated output ≥ 1.8 kW) |
| Detector | Digital Pulse Processing Counter (DPPC), count rate capacity ≥ 1×10⁷ cps |
| Sample Stage | Motorized goniometer with integrated Soller slits, fixed divergence slit, anti-scatter slit, and receiving slit |
| Compliance | CE-marked, IEC 61010-1 safety certified, radiation-shielded enclosure with interlocked safety door and real-time chamber status feedback |
| Software | CrystalX™ v3.x — automated phase identification (ICDD PDF-4+ database), quantitative Rietveld refinement, crystallinity index calculation (e.g., Lc, La, graphitization degree via (002) peak FWHM & d-spacing), energy-dispersive spectroscopy (EDS) co-acquisition support |
| Sample Forms | Powders, solid blocks, thin films, coatings |
| Dimensions | 620 × 540 × 480 mm (W × D × H) |
| weight | ~95 kg |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg-Brentano θ–2θ reflection mode |
| Power | kW-class microfocus X-ray source (rated output ≥ 1.2 kW) |
| Detector | Digital Pulse Processing Counter (DPPC) with throughput ≥ 1×10⁷ counts per second (CPS) |
| Slit System | Integrated fixed Soller slits (no moving adjustable components) |
| Sample Stage | Motorized goniometer with ±0.001° angular reproducibility |
| Safety | Interlocked full-enclosure sample chamber with real-time door status monitoring and automatic beam shutdown |
| Software | CrystalX™ automated phase identification & quantification suite with Rietveld refinement, crystallinity index calculation, and ASTM E1426-compliant data reporting |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano reflection (θs–θd) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ cps |
| Power | kW-class (integrated high-power microfocus X-ray source) |
| Compliance | CE-marked, IEC 61000-6-3/6-4, EN 62471 (UV/X-ray safety) |
| Sample Stage | Motorized goniometer with air-spring assisted large-window lift door |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg-Brentano θ–2θ reflection mode |
| Power Supply | kW-class integrated X-ray source (rated output ≥ 1.2 kW) |
| Detector | Digital Pulse Processing Counter (DPPC), count rate ≥ 1×10⁷ cps |
| Sample Stage | Precision goniometer with fixed θs–θd alignment |
| Optical Path | Integrated Soller slits (no moving adjustment parts), anti-scatter slit, receiving slit |
| Software | CrystalX™ v3.2 — automated phase identification, Rietveld quantitative analysis, crystallinity index calculation, PDF-4+ database integration |
| Compliance | Designed to meet ISO 17025 laboratory requirements |
| Safety | Interlocked full-enclosure sample chamber with auto-shutdown on door opening, real-time status feedback on HMI |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FRINGE Series |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | kW-class (Integrated High-Intensity X-ray Source) |
| Detector | DPPC (Digital Pulse Processing Counter Detector), ≥1×10⁷ cps |
| Optical Configuration | Fixed integrated Soller slits, θ–2θ reflection geometry (Bragg–Brentano), air-spring assisted large-window safety door |
| Software | CrystalX™ — automated phase identification, quantitative Rietveld refinement, crystallinity calculation, and EDXRF co-acquisition capability |
| Compliance | Designed to meet ISO 17025 laboratory requirements |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Applicable Standard | SH/T 1827–2019 |
| Measurement Principle | X-ray Diffraction (XRD) with Whole-Pattern Fitting |
| Sample Form | Granular or Powdered Polyolefins (PE, PP), Injection-Molded or Compression-Molded Specimens (α- and β+α-phase) |
| Detector | High-Resolution Scintillation Detector |
| Goniometer Architecture | θ–2θ Coupled Drive System (Single-Axis Motorized) |
| Cooling | Integrated Water-Circulation Cooling (Real-Time Monitoring of Temperature, Flow Rate & Velocity) |
| Software | CrystalX — Automated Crystallinity Quantification (DOC Calculation), ASTM/ISO-Compatible Data Export, Audit Trail & User Access Control |
| Safety | Interlocked Sample Chamber, Automatic X-ray Shutoff, Visual Closure Confirmation |
| Optical Component | Monolithic Soller Slit (Fixed, No Moving Parts) |
| Mobility | Designed for Benchtop and Mobile Lab Integration |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LabStation-5 |
| Instrument Type | Powder X-ray Diffractometer |
| Instrument Configuration | Floor-standing |
| Detector | High-Performance Photon-Counting (HPC) Pixelated Detector |
| Goniometer | θ/θ Closed-Loop Drive System |
| Optical Geometry | Switchable Bragg-Brentano & Parallel-Beam Configurations |
| Sample Stage | Modular, Tool-Free Quick-Release Sample Holder System |
| Diffractometer Radius | ≥300 mm |
| Beam Path Architecture | Non-Coplanar Arm Design |
| Slit System | Motorized Variable Aperture |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | SHINE Metal Corrosion Edition |
| Instrument Type | Powder X-ray Diffractometer |
| Power Supply | Integrated Low-Power X-ray Source (Details in Technical Datasheet) |
| Detector | CCD-based 2D X-ray Detector |
| Connectivity | USB 3.0, Bluetooth 5.0, Wi-Fi 802.11ac |
| Sample Mass Requirement | ~20 mg per analysis |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic |
| Model | SHINE Soil Edition |
| Instrument Type | Powder X-ray Diffractometer |
| Power Supply | As specified in technical documentation |
| Anode Target Options | Cu or Co |
| Detector | CCD-based 2D X-ray detector |
| Sample Requirement | ~20 mg per analysis |
| Connectivity | USB, Bluetooth, Wi-Fi |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SHINE REX900 |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano (BB) |
| Portability | Fully Integrated Ruggedized Enclosure |
| Radiation Safety | Fully Shielded, Zero Leakage During Operation |
| Data Output Formats | Excel, PDF |
| Connectivity | USB 2.0, Bluetooth 5.0, Wi-Fi 802.11ac |
| Software | CrystalX — Automated Phase Identification & Quantification Engine |
| Brand | JWGB (Jingwei Gaobo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Lattice GO |
| Instrument Type | Powder X-ray Diffractometer |
| Instrument Configuration | Portable |
| X-ray Tube Power | 30 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.2° |
| Dimensions (L×W×H) | 120 mm × 300 mm × 305 mm |
| Weight | 12 kg |
| X-ray Tube | Cu anode, 30 kV / 1 mA |
| Goniometer Geometry | Vertical θ–2θ Bragg–Brentano |
| Goniometer Radius | 110 mm |
| Detector | Photon-counting 2D array detector |
| Scan Speeds | 6°/min or 13°/min (selectable) |
| 2θ Range | 0°–130° |
| Battery Runtime | 3 hours |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LC-06 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Angular Resolution | < 0.05° |
| Effective Detection Area | 30 cm × 30 cm |
| Data Acquisition Time | Seconds per Laue Pattern |
| Gas Replacement Interval | Every 6 months |
| Coolant Replacement Interval | Annually |
| Sample Rotation Capability | Yes |