- All
- Favorite
- Popular
- Most rated
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TMA8310 |
| Sample Capacity | Ø9 mm × 20 mm |
| Heating Rate | Up to 100 °C/min |
| Cooling Rate | From 1000 °C to 50 °C in ≤15 min |
| Temperature Control | Pre-emptive temperature regulation with hold-mode overshoot compensation |
| Calibration | Integrated temperature and dimensional calibration routines |
| Power Mode | ECO standby mode (30% energy reduction) |
| Multi-unit Control | Single PC controls up to 8 units |
| Safety | Dual-stage furnace safety alarm + emergency stop switch |
| Software | Fully integrated thermal analysis suite with auto-diagnosis, dual data backup, and remote firmware update capability |
| Compliance | Designed for GLP/GMP environments |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | XRD-DSC |
| Heating Rate | 0.01–100 °C/min |
| Temperature Range | Ambient to 1500 °C |
| Temperature Stability | ±0.01 °C |
| Atmosphere Options | Inert, Oxidizing, Reducing (via optional gas modules) |
| Compliance | ASTM E1269, ISO 11357, USP <1158>, FDA 21 CFR Part 11 (software-enabled) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TG-DTA |
| Heating Rate | Up to 100 °C/min |
| Cooling Rate | 1500 °C → 50 °C in ≤20 min |
| Balance Type | Horizontal Differential Triple-Coil Microbalance |
| Temperature Control | Pre-Compensated PID with Isothermal Overshoot Compensation |
| Calibration | Integrated Temperature & Mass Calibration Functions |
| Power Mode | ECO Standby (30% Energy Reduction) |
| Software | Multi-Station Control (Up to 8 Units), Auto-Diagnosis, Dual Data Backup, Remote Firmware Update |
| Sample Handling | Plug-and-Play Sample Holder, Front-Access Sample Placement, Drop-Tolerant Horizontal Design |
| Optional Accessories | ASC Automatic Sample Changer, TG-DTA/GC-MS Hyphenated Interface |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | DSC8230 |
| Heating Rate | up to 150 °C/min |
| Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Multi-unit Control | up to 8 units via single PC |
| Temperature Control | Pre-compensated PID with hold-mode overshoot correction |
| Calibration | Built-in temperature calibration function |
| Power Mode | ECO standby mode (30% energy reduction) |
| Software | Integrated thermal analysis suite with auto-diagnosis, dual-data backup, remote firmware update, and configurable end-of-run actions |
| Sample Automation | Optional ASC (Automatic Sample Changer), field-installable |
| Hybrid Capability | Compatible with simultaneous XRD-DSC coupling |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TG-DTA |
| Temperature Range | RT–1100°C (standard), RT–1500°C (high-temp) |
| Max Heating Rate | 100°C/min |
| Atmosphere Options | Air, Inert Gas, Flowing Gas, Vacuum |
| Max Sample Mass | 1 g |
| TG Range | ±0.1–±250 mg |
| TG Sensitivity | 0.1 µg |
| DTA Range | ±1.5–±1000 µV |
| Sample Crucible | Ø2 mm × 2.5 mm height |
| Sample Holder Orientation | Horizontal |
| Forced Cooling | Yes (1500°C → 50°C in ≤20 min) |
| ECO Mode | Yes (30% power reduction in standby) |
| ASC Compatibility | Up to 24 samples |
| Optional IR Furnace | Yes |
| Dynamic TG Modes | SIA, DRC, CRC |
| Multi-unit Control | Up to 8 units per PC |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Mass Photo |
| Price | Upon Request |
| Interface | Conical quartz inlet mounted inside furnace with jet separator |
| Temperature Range | Ambient to 1100 °C |
| Mass Range | m/z 1–410 |
| Ionization Modes | Vacuum UV Photoionization (Patented Soft Ionization) and Electron Impact (EI) |
| Detection Capability | Fragment-free analysis of evolved gases including H₂ (m/z 1), CO, CH₄, H₂O, NH₃, NOₓ, VOCs, and high-mass organics up to m/z 410 |
Show next