Empowering Scientific Discovery

Beijing Lihua Saisi Technology Co., Ltd. (Authorized Distributor of Rigaku Products)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelTMA8310
Sample CapacityØ9 mm × 20 mm
Heating RateUp to 100 °C/min
Cooling RateFrom 1000 °C to 50 °C in ≤15 min
Temperature ControlPre-emptive temperature regulation with hold-mode overshoot compensation
CalibrationIntegrated temperature and dimensional calibration routines
Power ModeECO standby mode (30% energy reduction)
Multi-unit ControlSingle PC controls up to 8 units
SafetyDual-stage furnace safety alarm + emergency stop switch
SoftwareFully integrated thermal analysis suite with auto-diagnosis, dual data backup, and remote firmware update capability
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelXRD-DSC
Heating Rate0.01–100 °C/min
Temperature RangeAmbient to 1500 °C
Temperature Stability±0.01 °C
Atmosphere OptionsInert, Oxidizing, Reducing (via optional gas modules)
ComplianceASTM E1269, ISO 11357, USP <1158>, FDA 21 CFR Part 11 (software-enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelTG-DTA
Heating RateUp to 100 °C/min
Cooling Rate1500 °C → 50 °C in ≤20 min
Balance TypeHorizontal Differential Triple-Coil Microbalance
Temperature ControlPre-Compensated PID with Isothermal Overshoot Compensation
CalibrationIntegrated Temperature & Mass Calibration Functions
Power ModeECO Standby (30% Energy Reduction)
SoftwareMulti-Station Control (Up to 8 Units), Auto-Diagnosis, Dual Data Backup, Remote Firmware Update
Sample HandlingPlug-and-Play Sample Holder, Front-Access Sample Placement, Drop-Tolerant Horizontal Design
Optional AccessoriesASC Automatic Sample Changer, TG-DTA/GC-MS Hyphenated Interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelDSC8230
Heating Rateup to 150 °C/min
Cooling Rate400 °C → 50 °C in ≤4 min
Multi-unit Controlup to 8 units via single PC
Temperature ControlPre-compensated PID with hold-mode overshoot correction
CalibrationBuilt-in temperature calibration function
Power ModeECO standby mode (30% energy reduction)
SoftwareIntegrated thermal analysis suite with auto-diagnosis, dual-data backup, remote firmware update, and configurable end-of-run actions
Sample AutomationOptional ASC (Automatic Sample Changer), field-installable
Hybrid CapabilityCompatible with simultaneous XRD-DSC coupling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelTG-DTA
Temperature RangeRT–1100°C (standard), RT–1500°C (high-temp)
Max Heating Rate100°C/min
Atmosphere OptionsAir, Inert Gas, Flowing Gas, Vacuum
Max Sample Mass1 g
TG Range±0.1–±250 mg
TG Sensitivity0.1 µg
DTA Range±1.5–±1000 µV
Sample CrucibleØ2 mm × 2.5 mm height
Sample Holder OrientationHorizontal
Forced CoolingYes (1500°C → 50°C in ≤20 min)
ECO ModeYes (30% power reduction in standby)
ASC CompatibilityUp to 24 samples
Optional IR FurnaceYes
Dynamic TG ModesSIA, DRC, CRC
Multi-unit ControlUp to 8 units per PC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelThermo Mass Photo
PriceUpon Request
InterfaceConical quartz inlet mounted inside furnace with jet separator
Temperature RangeAmbient to 1100 °C
Mass Rangem/z 1–410
Ionization ModesVacuum UV Photoionization (Patented Soft Ionization) and Electron Impact (EI)
Detection CapabilityFragment-free analysis of evolved gases including H₂ (m/z 1), CO, CH₄, H₂O, NH₃, NOₓ, VOCs, and high-mass organics up to m/z 410