Thermogravimetric Analyzer
Filter
Showing 1–30 of 102 results
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region Classification | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 1250 °C |
| Mass Resolution | 1 µg |
| Mass Accuracy | ±1 µg |
| Dynamic Weighing Capacity | 0.01 mg–3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Load | 50 g |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA201 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.001 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g (expandable to 50 g) |
| Balance Sensitivity | 0.01 µg |
| Mass Accuracy | 0.01 mg |
| Heating Rate | 0.1–100 °C/min |
| Cooling Rate | –0.1 to –40 °C/min |
| Maximum Sample Mass | 30 g |
| Mass Precision | 0.01 mg |
| Temperature Stability | ±0.01 °C |
| Cooling Time (1000 °C → 50 °C) | ≤20 min (standard), ≤15 min with optional cryo-cooling unit |
| Atmosphere Control | Triple-gas mass flow controller |
| Data Acquisition Intervals | Real-time, 2 s, 5 s, or 10 s selectable |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 55 |
| Temperature Range | Ambient to 1000 °C |
| Balance Sensitivity | 0.1 μg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | <25 μg |
| Brand | DAZHAN (Nanjing Dazhan Instrument Co., Ltd.) |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Mass Range | 0.01 mg – 3 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 0.1 – 100 °C/min |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Display | 7-inch 24-bit color touchscreen interface |
| Communication | USB 2.0 bidirectional interface with proprietary PC software |
| Compliance | Designed for GLP-compliant workflows |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Range | 0.01 mg–30 g |
| Mass Sensitivity | 0.01 mg |
| Atmosphere Control | Dual-gas channel with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Display | 7-inch LCD touchscreen |
| Data Interface | USB |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, and GLP-compliant reporting |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Range | 0.01 mg–3 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Interface | Standard USB |
| Software | Integrated TGA analysis suite with TG/DTG curve processing, Excel/PDF export, multi-point temperature calibration, and audit-ready reporting |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic) |
| Balance Sensitivity | 0.01 mg |
| Balance Range | 0.01 mg–3 g (extendable to 30 g) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Programmable Stages | Up to 5 temperature segments |
| Isothermal Hold Duration | 0–300 min per segment (configurable up to 72 h total) |
| Display | 7-inch Chinese-language LCD |
| Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | DZ-TGA201 |
| Structural Design | Top-loading (elevating furnace) |
| Operating Environment | Ambient pressure |
| Sample Capacity | Single sample |
| Instrument Class | General-purpose TGA |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Dynamic Weighing Range | 0.01 mg to 3 g (extendable to 50 g) |
| Balance Sensitivity | 1 µg |
| Mass Accuracy | ±1 µg |
| Mass Repeatability | ±1 µg |
| Maximum Sample Mass | 50 g |
| Atmosphere Control | Triple-gas mass flow control (inert, oxidative, reducing) |
| Cooling Time | ≤20 min (1000 °C → 50 °C) |
| Temperature Control Algorithm | Adaptive PID with self-tuning and memory-based multi-segment programming |
| Exhaust Interface | Dedicated outlet for coupling with FTIR, MS, or GC-MS |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.1 °C |
| Mass Resolution | 0.1 µg |
| Isothermal Hold Duration | Up to 600 min (standard), user-definable |
| Atmosphere Control | Triple-Gas Mass Flow Controller (MFC) System |
| Cooling Time | ≤20 min (1000 °C → 50 °C) |
| Temperature Control Algorithm | Intelligent PID with Self-Tuning & Hybrid Static/Dynamic Optimization |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | TGA Thermostep ML |
| Temperature Range | 50–1000 °C |
| Temperature Accuracy | ±1 K |
| Balance Sensitivity | 0.1 µg |
| Maximum Sample Mass | 5 g |
| Simultaneous Sample Capacity | Up to 19 samples |
| Operating Environment | High-temperature inert or oxidative atmospheres (N₂, air, O₂) |
| Instrument Type | Benchtop manual-operation TGA system |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | THERMOSTEP |
| Maximum Operating Temperature | 1000 °C |
| Temperature Resolution | 1 °C |
| Sample Capacity | Up to 19 positions |
| Maximum Sample Mass | 5 g |
| Balance Resolution | 0.0001 g |
| Software | Windows®-based, Multilingual, Customizable Reporting |
| Compliance | Designed for ASTM D3172, D3174, D3175, ISO 1171, ISO 562, USP <281>, EN 15169, and GLP/GMP-aligned data integrity workflows |
| Brand | Henven (Beijing) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HFCT-1 |
| Structural Design | Horizontal Configuration |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Class | General-Purpose TGA-DTA/DSC Hybrid |
| Temperature Range | RT to 900 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision (Uncertainty) | 0.1 K |
| Dynamic Weight Range | 1–300 mg |
| Balance Sensitivity | 0.1 μg |
| Mass Accuracy | 0.1 μg |
| Heating/Cooling Rate | Up to 300 K/min |
| Maximum Load Capacity | 5 g |
| DSC Signal Range | ±500 mW |
| DSC Resolution | ±0.1 μW |
| DSC Accuracy | ±0.1 μW |
| DTA Voltage Range | ±10–±2000 μV |
| DTA Resolution | 0.01 μV |
| TG Noise Level | <0.1 μg |
| Atmosphere Control | Dual-channel Mass Flow Controllers (MFCs), Programmable Gas Switching, Compatible with Inert, Oxidizing, Reducing, and Vacuum (Optional) |
| Crucible Standard | Al₂O₃ |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | HKG |
| Price Range | USD 14,000–28,000 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | RT to 950 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | Up to 10 K/min (standard), configurable up to 300 °C/min |
| Maximum Sample Mass | 5 g |
| Baseline Drift | ≤0.01% of full scale |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose |
| Temperature Range | Ambient to 1000 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–80 K/min |
| Solid Feed Delivery Time | <1.0 s |
| Solid Feed Mass | 10–50 mg |
| System Response Delay | <2.0 s |
| Reactor Inner Diameter | ~20 mm |
| Reactor Height | <150 mm |
| Bed Material | Quartz Sand (d₅₀ = 200–300 µm) |
| Bed Height | 20–50 mm |
| Reproducibility Error | <10% |
| Gas Flow Controllers | 3 × Mass Flow Controllers (Air, H₂, CO, CO₂, CH₄ |
| Temperature Control | 0–1000 °C with Integrated Thermocouples |
| Pressure Monitoring | 0–1 atm |
| Hot-Gas Filtration | Ceramic/Fibrous Filter (Effective for Tar Retention) |
| Gas Analysis | 4-Channel In-Line Sensors (H₂: 0–3%, CO: 0–10%, CO₂: 0–3%, CH₄: 0–3%) |
| Pneumatic Switching | 11-Port Automated Solenoid Valve Bank (Programmable Dwell/Transition Times) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HQG-1 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HQG-2 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg to 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HQG-3 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HQG-4 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HTF |
| Price Range | USD 70,000–110,000 |
| Sample Capacity | Single sample per run |
| Instrument Type | Dedicated TGA platform |
| Temperature Range | Ambient to 950 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 K |
| Dynamic Weighing Range | 1 mg–200 mg or 0–5 g (selectable) |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1–30 K/min |
| Maximum Sample Mass | 5 g |
| Pressure Control Range | 0.1–5 MPa (at elevated temperature) |
| Pressure Control Precision | ±0.02 MPa |
| Steam Generation Range | 0.01–1000 mL/min (saturated water vapor, computer-controlled) |
| Atmosphere Control | Triple independent mass flow-controlled gas lines with automated switching and stabilization |
| Crucible Options | Standard ceramic crucible (Ø80 mm × H70 mm), compatible with sample masses up to 50 g |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HTF-50 |
| Price Range | USD 70,000–112,000 (FOB Beijing) |
| Test Environment | High-Pressure Atmosphere |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Dedicated TGA platform |
| Temperature Range | Ambient to 950 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Accuracy | ±0.1 K |
| Dynamic Weighing Range | 1 mg–200 mg or 0–5 g (user-selectable) |
| Balance Sensitivity | 10 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1–30 K/min |
| Maximum Sample Mass Capacity | 500 g |
| Baseline Drift | ≤0.01% (full-scale) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-1 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-2 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Vacuum Option | Up to 2.5 × 10⁻² Pa (with optional vacuum unit) |
| Standard Crucibles | Al₂O₃ (Φ5×4 mm, Φ5×8 mm, Φ8×10 mm, Φ18×8 mm, Φ18×15 mm, Φ18×20 mm) |
| Optional Crucibles | Aluminum, Graphite, Quartz, Platinum |
| Dual Thermocouples | Furnace Temp + Sample Temp Monitoring |
| Isothermal Hold Capability | Up to 72 h at any temperature within range |
| Data Output Modes | TG, DTG, DDTG, % Mass Loss, Kinetic Parameter Derivation, Multi-Curve Overlay & Differential Analysis |
| Software Calibration Support | Temperature & Mass calibration using certified reference materials |
| Optional Accessories | Isothermal Controller, GC/MS Transfer Interface (heated, 200 °C max), Heated Transfer Line, Corrosion-Resistant MFC Atmosphere System |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-3 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-4 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HWD-50g/500g |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.1 K |
| Dynamic Weighing Range | 10–50 g |
| Balance Sensitivity | 1000 µg |
| Mass Accuracy | 0.01% (100 ppm) |
| Heating/Cooling Rate | 0.1–40 K/min |
| Maximum Sample Mass | 500 g |
| Baseline Drift | ≤0.01% over 60 min |
| Weight Resolution | 1 mg |
| Weight Noise | <1 mg |
| Gas Control | Triple Mass Flow Controllers (MFCs) |
| Crucible Dimensions | Ceramic, Ø80 mm × H70 mm |
| Water Vapor Generator Output | 0.01–1000 mL/min (±0.01 mL/min resolution) |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HS-TGA-101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | RT to 1150 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 10 µg |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 2 g |
| Baseline Drift | ≤10 µg |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HS-TGA-302 |
| Test Environment | Ambient Pressure |
| Sample Capacity | 1 sample per run |
| Instrument Type | General-purpose |
| Temperature Range | RT to 1300 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0–100 °C/min |
| Maximum Sample Mass | 5 g |
| Baseline Drift | ≤10 µg |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | STA300 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.07 °C |
| Heating/Cooling Rate | 0.01–150 K/min |
| Maximum Sample Mass | 0.2 g |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TGA-605 |
| Temperature Range | Ambient to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 5 g |
| Mass Sensitivity | 0.01 mg |
| Mass Repeatability | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | ±0.1 °C |
| Baseline Reproducibility | ±0.1 °C |
| Sampling Frequency | 0.05–10 Hz (programmable) |
| Dual-Temperature Sensing | Furnace & Sample |
| Control Modes | FTC (Fixed Temperature Control) & STC (Sample Temperature Control) |
| Programmable Temperature Stages | Up to 12 |
| Cycle Repetition | Up to 9999 cycles with auto-data retention |
| Atmosphere Control | Two independent gas lines with software-driven switching |
| Display | 7-inch 24-bit color LCD touchscreen |
| Cooling System | Integrated capillary water-circulation furnace jacket |
| Furnace Design | Modular ceramic insulation with dual-purge gas channels |
| Optional Exhaust Interface | Dedicated port for off-gas coupling to FTIR or MS |
| Brand | JB Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | TGA-1350 |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.01 mg |
| Heating/Cooling Rate | 1–80 °C/min |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic) |
| Balance Capacity | 1 mg–2 g (extendable to 30 g) |
| Isothermal Hold Time | 0–300 min |
| Cooling Time | ≤15 min (1000 °C → 100 °C) |
| Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 489 × 400 × 343 mm |