Differential Scanning Calorimeter
Filter
Showing 1–30 of 207 results
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Julia DSC 300/500 |
| Instrument Type | Heat-Flux DSC |
| Special Function | Modulated DSC (MDSC®-compatible operation) |
| Simultaneous Sample Capacity | Up to 70 samples (with auto-sampler) |
| Temperature Range | –170 °C to 700 °C |
| Programmable Temperature Control | Dynamic and Isothermal modes |
| Temperature Accuracy | <0.1 K |
| Temperature Precision | 0.01 °C |
| Heating Rate | 0–300 K/min |
| Cooling Rate | 0–200 K/min |
| DSC Signal Range | ±2500 mW |
| Temperature Stability | ±0.1 °C (peak-to-peak, over 30 min) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Julia DSC |
| Instrument Type | Heat-Flux DSC |
| Special Function | Modulated DSC (MDSC®-compatible) |
| Simultaneous Sample Capacity | Up to 70 samples (with auto-sampler) |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | < 0.1 K |
| Temperature Precision | 0.01 °C |
| Heating Rate | 0–300 K/min |
| Cooling Rate | 0–200 K/min |
| DSC Signal Range | ±2500 mW |
| Temperature Stability | ±0.1 °C |
| Control Modes | Dynamic & Isothermal |
| Measurement Principle | Heat-Flux Differential Scanning Calorimetry |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Domestic Instrument Manufacturer |
| Model | DZ-DSC101 |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 800 °C |
| Temperature Accuracy | ±0.001 °C |
| Temperature Precision | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | ±800 mW |
| Temperature Control Method | Digital PID algorithm with programmable ramp-hold-cool profiles |
| Sensor Material | Constantan-based thermocouple array |
| Atmosphere Control | Dual-gas switching system with integrated flow regulation and auxiliary purge gas inlet |
| Cooling Method | Forced-air cooling |
| Compliance | Designed for GLP-compliant thermal analysis workflows |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Programmable Segments | Up to 6 heating/holding/cooling steps |
| Atmosphere Control | Dual-gas auto-switching (0–200 mL/min, ≤0.5 MPa) |
| Data Interface | Standard USB |
| Display | 7-inch 24-bit color LCD touchscreen |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300C |
| Temperature Range | −40 to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas auto-switching (up to 200 mL/min, ≤0.5 MPa), plus dedicated purge gas inlet |
| Thermal Program | Up to 6-segment ramp/hold |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB with auto-reconnect capability |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC400 |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1–20 °C/min (cooling, air-cooled variant) |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Atmosphere Control | Dual mass-flow-controlled gas channels + auxiliary purge line |
| Cooling Options | Air cooling, Peltier, mechanical refrigeration, or liquid nitrogen (model-dependent) |
| Software | Integrated GLP-compliant data acquisition and analysis suite with audit trail capability |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Programmable Temperature Control | Intelligent PID Algorithm |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), –0.1 to –20 K/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| Temperature Stability | ±0.1 °C |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Cooling Options | Forced-air, Peltier, Mechanical Refrigeration, Liquid Nitrogen |
| Atmosphere Control | Dual independent mass-flow-controlled gas channels + dedicated purge gas inlet |
| Sensor Type | Corrosion-resistant, EMI-shielded thermocouple array |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Domestic Instrument Manufacturer |
| Model | DZ-DSC400C |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | −50 °C to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Temperature Precision (Resolution) | 0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −40 K/min (cooling) |
| Scan Modes | Isothermal, dynamic heating, dynamic cooling |
| DSC Signal Range | ±1000 mW |
| Temperature Stability (Drift) | ≤0.1 °C/h |
| Cooling Method | Peltier-based active refrigeration (standard) |
| Gas Control | Triple-gas manifold with automatic dual-atmosphere switching (e.g., N₂ ↔ O₂), plus dedicated inert purge line |
| Temperature Control Algorithm | Adaptive PID with self-tuning and dynamic/static hybrid compensation |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DZ-DSC400C |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −50 °C to 600 °C |
| Programmable Temperature Control | Intelligent PID with Self-Tuning & Adaptive Optimization |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −40 K/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| Temperature Stability | ±0.001 °C |
| Cooling Method | Integrated Thermoelectric (Peltier) Module |
| Gas Flow Control | Triple-channel Mass Flow System (0–200 mL/min per channel), Dual Atmosphere Switching with <3 s stabilization time, plus Dedicated Inert Purge Line |
| Temperature Resolution | 0.001 °C |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400D |
| Price Range | USD 19,500–27,800 (FOB China) |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | −70 °C to 600 °C |
| Temperature Control | Intelligent PID algorithm |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −60 °C/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Gas Flow Range | 0–200 mL/min (expandable) |
| Cooling Method | Integrated mechanical refrigeration system (supplemented by optional air-cooling, Peltier, and liquid nitrogen interfaces) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400L |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −170 °C to 600 °C |
| Programmable Temperature Control | Intelligent PID |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −80 K/min (cooling) |
| Scan Modes | Isothermal, Heating, Cooling |
| DSC Signal Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Gas Flow Control | Dual-channel mass flow controller (0–200 mL/min, expandable), plus dedicated purge/protect gas inlet |
| Cooling Method | Liquid nitrogen cryogenic cooling (supplemented by optional air-cooling, Peltier, or mechanical refrigeration modules) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ3320A |
| Sample Capacity | Single |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0 to ±2000 µV (expandable) |
| DTA Sensitivity | 0.01 µV |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Control Interface | USB bidirectional communication |
| Display | 7-inch 24-bit color LCD touchscreen |
| Sensor Material | Ni-Cr alloy thermocouple |
| Furnace Design | Top-opening vertical furnace |
| Atmosphere Control | Programmable internal gas switching |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC100A |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | 0–200 mL/min (digital mass flow meter) |
| DSC Sensitivity | 0.01 mW |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Interface | USB 2.0 bidirectional communication |
| Control Architecture | ARM Cortex-M3 microcontroller |
| Calibration | Integrated standard reference materials with one-click temperature & enthalpy calibration |
| Power Supply | AC 220 V / 50 Hz |
| Brand | NANJING DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | ±600 mW |
| Baseline Stability | ±0.01 °C |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Temperature Accuracy | ±0.001 °C |
| Atmosphere Control | Dual-gas auto-switching (N₂, Air, or custom gas) |
| Flow Rate | 0–300 mL/min |
| Max Pressure | ≤5 MPa |
| Thermal Program | Up to 6 segments (heating/holding/cooling) |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300C |
| Temperature Range | −40 to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Atmosphere Control | Dual-gas auto-switching (up to 200 mL/min, ≤0.5 MPa), plus inert purge line |
| Data Interface | USB 2.0 with auto-reconnect |
| Display | 7-inch 24-bit color touchscreen |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DZHAN |
|---|---|
| Model | DZ-DSC100A |
| Origin | Jiangsu, China |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | 0–200 mL/min (digital mass flow meter) |
| DSC Sensitivity | 0.01 mW |
| Interface | USB 2.0 |
| Display | 7-inch 24-bit color TFT touchscreen |
| Power Supply | AC 220 V / 50 Hz |
| Compliance | Includes certified reference materials and one-click calibration for temperature and enthalpy |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC100A |
| Price Range | USD 4,200–7,000 (FOB) |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| DSC Sensitivity | 0.01 mW |
| Gas Flow Control | Digital Mass Flow Controller (0–200 mL/min) |
| Display | 7-inch 24-bit color capacitive touchscreen LCD |
| Communication Interface | USB 2.0 (bidirectional) |
| Sensor Material | Corrosion-resistant alloy thermopile |
| Calibration | Integrated standard reference materials (e.g., In, Sn, Zn) with one-click auto-calibration for temperature and enthalpy |
| Power Supply | AC 220 V / 50 Hz (customizable for 110 V / 60 Hz) |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Gas Control | Dual-channel automatic switching, flow 0–200 mL/min, pressure ≤0.5 MPa |
| Thermal Program | Up to 6 segments (ramp/hold/cool), max hold time ≤24 h |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Compliance | ASTM E794, ISO 11357-1, USP <1163>, GLP-ready software audit trail |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC300 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas automatic switching (N₂, Ar, air), flow rate 0–200 mL/min, max pressure 0.5 MPa |
| Thermal Program | Up to 6-segment ramp/hold/cool sequences, isothermal duration ≤24 h |
| Display | 7-inch 24-bit color TFT touchscreen |
| Data Interface | Standard USB 2.0 |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC300 |
| Sample Capacity | Single-sample |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Isothermal Hold Duration | Up to 24 h |
| Atmosphere Control | Dual-gas automatic switching (N₂, Air, Ar, or custom), 0–200 mL/min flow, ≤0.5 MPa pressure |
| Control Mode | Fully programmable 6-segment heating/holding/cooling sequences with PID regulation |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, real-time baseline correction, GLP-compliant data logging |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Stability | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±800 mW |
| DSC Sensitivity | 0.001 mW |
| Temperature Control | PID-based Automatic Programmed Control |
| Thermal Environment | Triple-layer insulated furnace lid |
| Atmosphere Control | Dual-gas inlet with automatic switching (0–200 mL/min, ≤0.5 MPa) |
| Data Interface | Standard USB |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, six-segment programmable thermal profiles, real-time bidirectional control (instrument + PC) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling (Fully Automated) |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (Expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Gas Control | Dual-channel Automatic Switching (N₂, Air, or Custom Gases), Flow Rate 0–200 mL/min, Max Pressure 0.5 MPa |
| Thermal Calibration Standards Included | Indium, Tin, Lead |
| Data Interface | USB 2.0 |
| Display | 7-inch 24-bit TFT LCD Touchscreen |
| Power Supply | AC 220 V / 50 Hz (Optional Custom Voltage) |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC300 |
| Sample Capacity | Single-sample |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Programmable Temperature Control | Fully Automated Multi-Stage Ramp/Hold/Cool |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (field-expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Isothermal Hold Duration | Up to 24 h |
| Atmosphere Control | Dual-gas auto-switching (N₂, Ar, O₂, or custom), 0–200 mL/min flow, ≤0.5 MPa pressure |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Data Interface | Standard USB 2.0 |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, GLP-compliant audit trail, real-time baseline correction |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300C |
| Temperature Range | −40 to 600 °C |
| Temperature Accuracy | ±0.0001 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| DSC Resolution | 0.01 µW |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual automatic gas switching (up to 300 mL/min, ≤5 MPa), plus dedicated purge/protect gas inlet |
| Thermal Control Modes | Programmable multi-segment heating, isothermal hold, and cooling (up to 6 segments) |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Interface | Standard USB 2.0 with auto-reconnect capability |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC400 |
| Temperature Range | Ambient to 600 °C |
| DSC Measurement Range | ±800 mW |
| Temperature Accuracy | ±0.0001 °C |
| Temperature Precision | ±0.0001 °C |
| Heating Rate | 0.1–100 K/min |
| Cooling Rate | −0.1–20 K/min |
| Temperature Stability | ±0.1 °C |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| DSC Noise Level | 0.1 µW |
| Gas Flow Control | Dual-channel mass flow controller (0–200 mL/min), with auxiliary purge gas inlet |
| Cooling Options | Forced-air cooling (standard), optional Peltier and liquid nitrogen cooling modules |
| Brand | Jiubin |
|---|---|
| Model | JB-DTA-1350 |
| Origin | Shanghai, China |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 1–80 °C/min |
| DTA Signal Range | ±2000 μV |
| DTA Sensitivity | 0.01 μV |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Furnace Type | Top-opening dual-wound Fe-Cr-Al heating element (1 kW) |
| Atmosphere Control | Automated internal gas switching |
| Interface | Standard USB 2.0 |
| Display | 7-inch 24-bit color TFT LCD touchscreen |
| Calibration | Built-in reference materials with one-click temperature calibration |
| Baseline Adjustment | Adjustable slope and intercept |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HCR |
| Price Range | USD 10,800–15,000 (FOB Beijing) |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Differential Thermal Analysis (DTA) |
| Temperature Range | RT to 1150 °C (HCR-1), RT to 1250 °C (HCR-2), RT to 1450 °C (HCR-3), RT to 1550 °C (HCR-4) |
| Programmable Temperature Control | Heating and Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Operating Mode | Fully Automated |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Scan Modes | Dynamic heating, isothermal stabilization |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±1 mW to ±500 mW |
| Temperature Stability (Drift) | ≤0.1 °C over 24 h |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| Voltage Input Range | ±10 µV to ±2000 µV (auto-ranging) |
| Vacuum Capability (Optional) | 2.5×10⁻² Pa |
| Atmosphere Control | Dual-channel mass flow controller (MFC)-based gas delivery with automatic switching |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional | Aluminum, graphite, quartz, platinum |
| Isothermal Duration | Up to 72 h at any setpoint within operating range |
| Calibration Standards Supported | Indium, tin, lead (for temperature and enthalpy calibration) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HCR-1 |
| Sample Capacity | Single-sample |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Temperature Range | Ambient to 1150 °C |
| Programmable Temperature Control | Heating and Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| Scan Modes | Dynamic heating, isothermal hold |
| DSC Measurement Range | ±1–±500 mW |
| DSC Sensitivity | ±0.1 μW |
| DTA Resolution | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| Signal Range | ±10–±2000 μV (auto-ranging) |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching, corrosion-resistant options available |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Isothermal Duration | Up to 72 h at any temperature within range |
| Calibration Standards Supported | Indium, tin, lead |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-2 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| DTA Sensitivity | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| DSC Measurement Range | ±1–±500 mW |
| DSC Precision | ±0.1 μW |
| Sample Capacity | Single-sample configuration |
| Control Mode | Manual sample loading |
| Thermal Program Modes | Ramp heating, isothermal hold (up to 72 h at any temperature within range) |
| Atmosphere Control | Dual-channel mass flow controller (MFC)-based gas delivery with automatic switching |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Signal Output Range | ±10–±2000 μV (auto-ranging) |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Interface | Integrated LCD display showing furnace temperature, sample temperature, gas status, and real-time signal |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy estimation (multiple algorithms), Tg determination, specific heat comparison method, calibration support (In, Sn, Pb), screenshot capture at arbitrary timestamps, user-defined formula implementation |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-3 |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| DSC Measurement Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 µW |
| Atmosphere Control | Dual-channel MFC-controlled gas system (N₂, Ar, O₂, air |
| Vacuum Option | 2.5×10⁻² Pa (with optional vacuum unit) |
| Isothermal Hold Duration | Up to 72 h at any temperature within range |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy determination (multiple model algorithms), Tg identification, specific heat comparison method, real-time screenshot capture, auto-scale signal acquisition, calibration support (In, Sn, Pb standards) |
