X-ray Diffractometer
Filter
Showing 113–128 of 256 results
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HPXRD |
| Configuration | Floor-Standing |
| X-ray Source | Liquid-Metal In Target (E1 Type) |
| High-Flux Mode | 90 μm focal spot, 1.9 × 10⁸ ph/s, divergence 3.15 mrad |
| Micro-Focus Mode | 15 μm focal spot, 1.8 × 10⁷ ph/s, divergence 12.6 mrad |
| Ultra-Micro Mode | 10 μm focal spot, 1.0 × 10⁶ ph/s, divergence 2 mrad |
| XY Stage Repeatability | ±0.2 μm, travel ±10 mm |
| Z Stage Repeatability | ±0.2 μm, travel ±10 mm |
| φ Axis Repeatability | 0.002°, travel ±135° |
| X₁Y₁ Stage Repeatability | ±0.2 μm, travel ±12.5 mm |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | APD 2000 PRO |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Tube Power | 0.0001 kW (100 W) |
| Radiation Source | Fine-focus Ceramic X-ray Tube |
| Monochromator | Johannson-type Kα₁ monochromator |
| Detector Types | Scintillation Counter & Energy-Dispersive Detector |
| Goniometer Control | Optical Encoder |
| Sample Stage | Motorized Multi-Sample Rotating Stage with Low-Background Options |
| Safety System | Dual Redundant Interlock Circuit |
| Compliance | CE, IEC 61010-1, ISO 9001 |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EXPLORER |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Optical Configuration | Switchable Bragg-Brentano focusing / Johansson monochromator / Parabolic mirror monochromator |
| Beam Geometry | Parallel-beam optics with low-angle reflection capability |
| Thin-film Thickness Detection Range | 1–500 nm |
| Degrees of Freedom for Sample Manipulation | 5 |
| Modular Units | 7 |
| Primary Applications | Phase identification & quantification, crystallite size and microstrain analysis, residual stress measurement, texture analysis, thin-film characterization, depth profiling, nanocrystalline material assessment |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EXPLORER |
| Instrument Type | Powder X-ray Diffractometer |
| Sample Geometry Compatibility | Bragg–Brentano Focusing & Johansson/Parabolic Mirror Monochromator Configurable |
| Optical Configuration | Parallel-Beam Geometry with Thin-Film Attachment |
| Resolution Capability | 1–500 nm Thickness Profiling |
| Analytical Capabilities | Phase Identification & Quantification, Crystallite Size & Microstrain Determination, Crystallinity Index, Residual Austenite Analysis, Texture & Preferred Orientation Mapping, Residual Stress Evaluation, Thin-Film Depth Profiling, Nanoparticle Structural Characterization |
| Drive System | Direct-Drive High-Torque Motor with High-Resolution Optical Encoder |
| Modular Design | 7 Interchangeable Modules, 5-Axis Independent Sample Positioning |
| Software Platform | Integrated Windows-Based Acquisition & Analysis Suite with Advanced Rietveld Refinement, PDF Database Search (ICDD), and GLP-Compliant Audit Trail |
| Brand | Hantekx |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HTXD-2 |
| Price Range | USD 35,000–70,000 |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Generator Power | 2 kW |
| Tube Voltage Range | 15–50 kV (1 kV steps) |
| Tube Current Range | 6–40 mA (1 mA steps) |
| High-Voltage Cable Rating | 75 kV dielectric strength, 2 m length |
| Cooling System | Recirculating chiller, nominal cooling capacity 4000 W, flow rate 3.5 L/min |
| Goniometer Geometry | Vertical θ–θ configuration |
| Scan Radius | 180 mm |
| Minimum Step Size | 0.00025° |
| Minimum Data Collection Step | 0.01° |
| Angular Reproducibility | ≤0.0006° |
| Scan Speed Range | 0.125–16°/min |
| Detector Options | 0D (scintillation counter), 1D (linear PSD), 2D (area detector) |
| Radiation Safety | Shielded enclosure with interlocked shutter and door |
| Brand | Hantekx |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HTXD-3 |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 2 kW |
| X-ray Tube Voltage Range | 15–50 kV (1 kV steps) |
| X-ray Tube Current Range | 6–40 mA (1 mA steps) |
| Goniometer Geometry | θ–θ vertical configuration |
| Scan Radius | 180 mm |
| Minimum Step Size | 0.00025° |
| Positional Reproducibility | ≤0.0006° |
| Minimum Data Collection Step | 0.01° |
| Scan Speed Range | 0.125–16°/min |
| Detector Options | 0D scintillation counter (max. linear count rate 500,000 cps), 1D position-sensitive detector (640 or 1280 channels), optional 2D detector |
| Pulse Processing | Linear amplifier (gain up to 20×, 5-step adjustment |
| Cooling System | Recirculating chiller (nominal cooling capacity 4000 W, flow rate 3.5 L/min) |
| Radiation Safety | Interlocked shutter and door safety system |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DX-2700BH |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Floor-standing |
| X-ray Generator Power | 3 kW |
| Angular Accuracy | ±0.0001° |
| Resolution (FWHM) | SiO₂ ≤ 60% |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DX-27mini |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Rating | 600 W (40 kV / 15 mA) or 1200 W (40 kV / 30 mA) |
| Angular Accuracy | 0.0001° |
| Resolution (FWHM) | SiO₂ ≤ 60% |
| X-ray Source | Metal-ceramic Cu-target tube, focal spot 1 × 10 mm |
| Goniometer Geometry | Horizontal θ–θ (sample-and-detector movement) |
| Radius of Diffraction Circle | 150 mm |
| Scan Modes | Continuous and Step Scanning |
| Angular Range (θs/θd coupled) | –3° to 150° |
| Minimum Step Size | 0.0001° |
| Angular Reproducibility | ±0.0005° |
| Angular Positioning Speed | 1500°/min |
| Detector Options | Sealed proportional counter or high-speed 1D semiconductor array |
| Energy Resolution | <25% (at Mn Kα) |
| Linear Count Rate | ≥5 × 10⁵ cps (proportional), ≥9 × 10⁷ cps (1D semiconductor) |
| Radiation Shielding | Lead + lead-glass enclosure |
| Overall System Stability | ≤1% RSD over 8 h |
| Sample Capacity | 6-position automated sample changer |
| Dimensions (W × D × H) | 600 × 410 × 670 mm |
| Cooling | Air or water (≥2.5 L/min) |
| Software Platform | Windows 7-based instrument control and data analysis suite |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Floor-Standing |
| Angular Resolution | 0.001° |
| Angular Accuracy | ±0.0001° |
| Peak Resolution (FWHM) | SiO₂ ≤ 60% |
| Detector | High-Performance Semiconductor Array Detector |
| X-ray Source | Stabilized Cu Kα Sealed-Tube Source |
| Calibration Standard Compliance | NIST-traceable Si & α-Al₂O₃ reference materials (full-pattern angular deviation ≤ ±0.01°) |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DX-2900 |
| Instrument Type | High-Resolution X-ray Diffractometer |
| Configuration | Floor-Standing |
| Power | 50 W |
| X-ray Source | Cu or Mo anode (50 kV / 1 mA) |
| Capillary Optics | Collimation ≤ 0.25°, Focal Spot Diameter: 0.5 mm, Photon Flux > 1×10⁸ ph/s |
| Goniometer | Two-Axis Thin-Film Stage (ω: –10° to +10°, resolution 0.002° |
| Z | 0–15 mm, resolution 0.002 mm) |
| Detector | 2D Array (512 × 512 pixels, pixel size 75 µm) |
| Optional Accessories | Transmission stage, in-situ heating stage (up to 600 °C), inert-atmosphere chamber, solvent vapor chamber, XY translation stage (150 mm × 150 mm), upgradeable to 3–5-axis thin-film goniometer or Pilatus200K/Eiger500K detectors |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DX2900H |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Powder & Thin-Film X-ray Diffractometer |
| X-ray Source Power | 50 W |
| Anode Material | Cu or Mo |
| Beam Collimation | Multicapillary Optics (0.25° divergence) |
| Focal Spot Size | 0.5 mm |
| Photon Flux | >1×10⁸ ph/s |
| Goniometer Axes | 2-axis thin-film stage (ω: −10° to +10°, resolution 0.002° |
| Z | 0–15 mm, resolution 0.002 mm) |
| Detector | Dectris Pilatus100K (487 × 195 pixels, pixel size 172 µm) |
| Optional Upgrades | 3–5-axis film stage, Pilatus200K/Eiger500K/Eiger1M detectors, transmission stage, in-situ heating stage, solvent vapor chamber, inert-atmosphere glovebox-integrated stage |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | DX2900V |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Powder X-ray Diffractometer |
| Angular Resolution | 0.1° |
| X-ray Source | Cu/Mo anode, 50 W (50 kV / 1 mA) |
| Capillary Optics | Multicapillary, divergence ≤ 0.25°, focal spot diameter 0.5 mm, photon flux > 1×10⁸ ph/s |
| Goniometer Axes | Two-axis thin-film stage (ω: −10° to +10°, resolution 0.002° |
| Z | 0–15 mm, resolution 0.002 mm) |
| 2D Detector | Eiger2 R 250K, 512 × 512 pixels, pixel size 75 µm |
| XY Sample Stage | 150 mm × 150 mm travel range |
| Optional Accessories | Transmission stage, in-situ heating stage, inert-atmosphere glovebox-integrated stage, solvent vapor-compatible in-situ atmosphere chamber |
| Upgradability | Thin-film stage extendable to 3–5 axes |
| Brand | Hefei Kejing |
|---|---|
| Model | DX-100 |
| Origin | Anhui, China |
| Power Supply | 220 V AC, 50 Hz, 0.5 kW |
| X-ray Tube | Cu anode, air-cooled, grounded anode |
| Max. Operating Voltage/Current | 30 kV / 5 mA (continuously adjustable) |
| Detector | Geiger-Müller counter |
| Detector Bias Voltage | up to 1050 V |
| Time Constant Settings | Fast (1 s) and Slow (2 s) |
| Angular Readout | Mechanical scale (2θ/θ resolution: 1°), digital display in degrees-minutes-seconds (minimum digital resolution: 10″) |
| Angular Range | 2θ = –10° to +140° |
| Collimator Slits | 4′, 5′, 6′ |
| Peak Position Accuracy | ±30″ |
| Primary Beam Shutter | Motorized |
| Dimensions (Main Unit) | 628 × 512 × 428 mm |
| Dimensions (Control Box) | 520 × 520 × 468 mm |
| Net Weight | 45 kg |
| Brand | Hefei Kejing |
|---|---|
| Model | X-3 / X-4 / X-4A |
| Type | Double-Crystal Diffractometer-Based Orienting System |
| Angular Accuracy | ±15 arcseconds |
| Minimum Readout Resolution | 15″ (X-3), 10″ (X-4), 1″ (X-4A) |
| Angular Range | 2θ = 10°–120°, θ = −10°–60° |
| X-ray Source | Cu-target, air-cooled tube |
| Max. Operating Voltage/Current | 30 kV / 1 mA |
| Time Constants | 0.4 s / 0.8 s |
| Power Supply | AC 220 V, 50 Hz, 0.5 kW |
| Monochromator | Built-in graphite monochromator |
| Compliance | JB/T 5482–2004 |
| Dimensions (L×W×H) | 1140 × 650 × 1100 mm |
| Weight | 300 kg |
| Origin | Liaoning, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DST-17 |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Tube Voltage | 10–60 kV |
| Tube Current | 5–50 mA |
| 2θ Angular Range | 110°–170° |
| ψ Angle Range | 0°–60° |
| φ Angle Range | 0°–360° |
| α Angle Range | 0°–70° |
| 2θ Resolution | ≤0.01° |
| 2θ Repeatability | ±0.0001° |
| Beam Spot Options | Circular (0.2/0.5/1/2 mm) |
| Target Materials | Cu, Cr, Fe, Ti, V, Co, Mn (metal-ceramic anodes) |
| X-ray Stability | <0.005% |
| Compliance | ASTM E915-2010, EN 15305:2008, GB/T 7704–2008, ISO 9001 |
| Origin | Liaoning, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DX-2700BH |
| Price | ¥380,000 |
| Instrument Type | Powder X-ray Diffractometer |
| Power | As specified in technical documentation |
