| Origin | Liaoning, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DX-27mini |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Power Options | 600 W (40 kV, 15 mA) or 1200 W (40 kV, 30 mA) |
| X-ray Tube | Metal-ceramic, Cu anode, 2.4 kW nominal power, focal spot 1 × 10 mm |
| Cooling | Air or water-cooled (≥2.5 L/min) |
| Goniometer Geometry | Horizontal θs–θd configuration, radius 150 mm |
| Scan Modes | Continuous and step scanning |
| Angular Range (θs/θd coupled) | –3° to 150° |
| Minimum Step Size | 0.0001° |
| Angular Reproducibility | ±0.0005° |
| Angular Positioning Speed | 1500°/min |
| Energy Resolution | <25% (FWHM at Mn Kα) |
| Detector | Sealed proportional counter or high-speed 1D semiconductor detector |
| Linear Count Rate | ≥5 × 10⁵ cps (proportional), ≥9 × 10⁷ cps (1D semiconductor) |
| Control System | Dell commercial laptop, Windows 7 OS |
| Software | Integrated instrument control (X-ray generator HV/current, shutter, tube aging protocol), goniometer motion control, real-time data acquisition, peak detection (auto/manual), background subtraction, smoothing, intensity integration, centroid calculation, peak amplification, spectral overlay |
| Data Analysis | Phase identification & quantification, α₁/α₂ stripping, whole-pattern fitting (WPF), selective peak fitting, FWHM & crystallite size analysis (Scherrer, Williamson–Hall), unit cell refinement, biaxial stress calculation, indexing of diffraction lines, multi-plot & 3D visualization, calibration, background modeling, standardless quantitative analysis, XRD pattern simulation |
| Radiation Shielding | Lead + lead-glass enclosure |
| System Stability | ≤1% RSD over 8 h |
| Sample Handling | Auto-sampler for up to 6 samples per batch |
| Dimensions (W×D×H) | 600 × 410 × 670 mm |
| Brand | IDONANO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | N3 PhiniX |
| Instrument Type | High-Resolution X-ray Diffractometer |
| Configuration | Benchtop |
| Generator Power | 600 W (40 kV / 15 mA) or 1200 W (40 kV / 30 mA) |
| Goniometer Accuracy | θ/θ configuration |
| Detector Options | IDO640 photon-counting 1D linear array detector |
| Brand | IDONANO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | N3 PhiniX Plus |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Generator | 600 W (40 kV / 15 mA) or 1200 W (40 kV / 30 mA) |
| Goniometer | θ/θ configuration |
| Angular Accuracy | < ±0.01° (2θ) |
| X-ray Tube Anodes | Cu, Co, Mo, Ag (user-selectable) |
| Detectors | IDO640 photon-counting linear array |
| Sample Stages | Standard flat-stage |
| Power Requirement | 200–240 V AC |
| Control | External PC-based operation |
| Brand | In-situ High-tech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CIS-XRD-HC |
| Pricing | Upon Request |
| Max Operating Temperature | 500 °C |
| Heating Rate | 25–30 °C/min |
| Sample-Sensor Temperature Deviation | 20–60 °C |
| Internal Pressure | Ambient (1 atm) |
| Cell Body Material | Electropolished SUS316 Stainless Steel |
| Window Material | Polyimide Film (PI) |
| Standard Battery Format | Ø18 mm × 2 mm (customizable) |
| Temperature Control System | Dedicated Programmable PID Controller with Touchscreen Interface & PC Software |
| Cooling System | 270 W Recirculating Chiller |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | IPX-LC |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Jordan Valley Delta-X |
| Instrument Type | Powder X-ray Diffractometer |
| Power Stability | < 0.0001 (unitless, relative intensity stability) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Source | Sealed Mo-target Tube |
| Maximum Power | 1600 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.1° |
| Goniometer Geometry | Vertical θ–2θ |
| Goniometer Radius | 144 mm |
| Angular Range | 0°–150° |
| Detector | Photon-counting 2D Array Detector |
| Sample Stage | Temperature-Controlled Pouch-Cell Holder (−30 °C to 300 °C) |
| Dimensions | 900 mm × 680 mm × 550 mm |
| Weight | 100 kg |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Lattice Series |
| Instrument Type | Powder X-ray Diffractometer |
| Instrument Configuration | Benchtop |
| X-ray Power | 1200 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.1° |
| Detector | 256 × 256 Pixel Photon-Counting 2D Array Detector |
| Goniometer Geometry | θ–2θ (Lattice Basic) or θ–θ (Lattice Pro) |
| X-ray Tube Anode Material | Cu or Co (sealed tube) |
| Angular Range | –3° to 156° (Z-axis tilt ≤ –20°), 0° to 160° (Z-axis tilt > –20°) |
| Goniometer Radius | 150–228 mm (adjustable) |
| Detector Energy Resolution | 0.2 keV |
| Dimensions | 900 mm × 680 mm × 550 mm |
| Weight | 100 kg |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Model | FRINGE C1600 |
| Regulatory Classification | Domestic (China) |
| Key Features | θ–2θ coupled goniometer with single-axis drive |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Model | FRINGE CLASS |
| Power Supply | As specified in technical documentation |
| Detector | Proportional Counter (≥500 kcps count rate) |
| Geometry | Bragg–Brentano θ–2θ reflection mode |
| Cooling System | Integrated water recirculation cooling |
| Compliance | CE-marked, compliant with IEC 61000-6-3 (EMC) and IEC 61000-6-4 (emission standards) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FRINGE D200 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Rating | kW-class (air-cooled or integrated water-cooling system) |
| Detector | Xeye2D 2D hybrid pixel array detector |
| Goniometer | High-precision vertical θ–θ configuration |
| Software | CrystalX automated phase analysis suite |
| Sample Compatibility | Powders, bulk solids, thin films, liquids |
| Safety | Interlocked sample chamber, automatic beam shutter, real-time door status feedback |
| Optional Accessories | High-temperature stage, cryo-stage, humidity-controlled cell |
| Compliance | Designed to meet IEC 61010-1 (safety), ISO 17025 operational readiness guidelines, and GLP-aligned data integrity practices |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg-Brentano θ–2θ reflection mode |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ counts per second (CPS) |
| Power | kW-class microfocus X-ray source (exact rating per configuration) |
| Compliance | CE-marked, IEC 61000-6-3/6-4, IEC 62471 (LED/X-ray safety) |
| Sample Handling | Motorized sample stage with integrated Soller collimator, air-spring assisted large-window hinged door |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ–2θ reflection |
| Detector | Digital Pulse Processing Counter (DPPC) |
| Maximum Count Rate | ≥1 × 10⁷ counts per second (CPS) |
| Sample Forms | Powders, bulk solids, thin films |
| Software | CrystalX™ automated phase identification & quantification suite |
| Compliance | Designed for GLP-compliant workflows |
| Safety | Interlocked sample chamber with auto-shutdown, real-time door status feedback, full enclosure during operation |
| Optical Path | Integrated fixed Soller slits, divergence slit, anti-scatter slit, receiving slit |
| Power Supply | High-voltage generator rated for kW-class operation (exact rating model-specific |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ–2θ reflection |
| Power Rating | kW-class (rated for continuous operation) |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ counts per second (CPS) |
| Optical Configuration | Integrated Soller slits, fixed divergence slit, anti-scatter slit, receiving slit |
| Sample Stage | Motorized goniometer with precision angular encoder |
| Safety Compliance | Interlocked sample chamber, automatic beam shutter activation upon door opening, real-time chamber status feedback on GUI |
| Software Platform | CrystalX — automated phase identification, quantitative Rietveld refinement, crystallinity index calculation, PDF-4+ database integration |
| Regulatory Alignment | Designed to support GLP-compliant workflows |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg-Brentano θ–2θ Reflection |
| Detector | Digital Pulse Processing Counter (DPPC) |
| Count Rate Capacity | ≥1 × 10⁷ counts per second (CPS) |
| Sample Stage | Fixed-center goniometer with integrated Soller slits |
| Power Supply | kW-class microfocus X-ray source (exact rating specified in technical documentation) |
| Compliance | CE-marked for laboratory use |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | FRINGE EV |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | kW-class (integrated sealed X-ray tube) |
| Geometry | Bragg–Brentano reflection (θs–θd) |
| Detector | High-sensitivity scintillation or silicon-strip detector (configurable) |
| Sample Stage | Motorized goniometer with ±0.001° angular resolution |
| Software Platform | CrystalX v3.x (with ICDD PDF-4+ database integration) |
| Compliance | CE, RoHS, IEC 61000-6-3/6-4, EN 62471 (UV/soft X-ray safety) |