Empowering Scientific Discovery

IKA MATRIX Orbital Delta F2.0 Temperature-Controlled Orbital Shaker

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand IKA
Origin Germany
Model MATRIX Orbital Delta F2.0
Orbit Diameter 3 mm
Max Load 0.3 kg
Speed Range 0–1500 rpm
Min Adjustable Speed 300 rpm
Speed Accuracy ±30 rpm
Speed Resolution 10 rpm steps
Timer Range 1 s – 6000 min
Heating Range RT +4 °C to 100 °C
Heating Power 100 W
Temp. Control Accuracy ±0.5 °C
Temp. Uniformity ±0.5 °C (20–45 °C), ±1.5 °C (>45 °C)
Heating Rate 13 °C/min
Sample Capacity 24 × 2.0 mL tubes
Dimensions (W×D×H) 216 × 158 × 351 mm
Weight 9.2 kg
Ambient Operating Conditions 5–40 °C, ≤80% RH
Protection Class IP21
Interfaces RS232, USB
Power Supply 100–240 V, 50/60 Hz
Max Input Power 240 W
Fuse 2 × T4A 250V

Overview

The IKA MATRIX Orbital Delta F2.0 is a precision-engineered temperature-controlled orbital shaker designed for reproducible mixing and thermal conditioning of small-volume biological samples in standardized microcentrifuge tubes. It operates on the principle of orbital shaking—generating a circular motion with a fixed 3 mm orbit diameter—to induce homogeneous suspension, resuspension, or dissolution without vortexing or splashing. Integrated Peltier-based heating enables precise, programmable temperature control from ambient +4 °C up to 100 °C, making it suitable for applications requiring simultaneous agitation and thermal incubation—including enzymatic reactions, cell lysis, immunoassays, and nucleic acid handling. Its compact footprint, aluminum die-cast housing, and IP21-rated enclosure ensure mechanical stability, operator safety, and compatibility with standard laboratory environments under GLP-compliant workflows.

Key Features

  • Orbital motion with 3 mm orbit diameter ensures gentle yet efficient mixing of viscous or low-volume samples (e.g., 20–2000 µL) across all 24 positions
  • Speed range of 0–1500 rpm with 10 rpm resolution and real-time TFT display for precise kinetic control; speed automatically adapts to load and temperature via intelligent algorithm
  • Dual-mode operation: continuous, timer-based, and multi-step programmable protocols—including ramped heating profiles (linear temperature gradients over time)
  • Peltier heating system with 100 W output delivers rapid thermal equilibration (up to 13 °C/min) and maintains ±0.5 °C stability at setpoints between 20–45 °C
  • Robust aluminum die-cast chassis minimizes vibration transmission and supports long-term 100% duty-cycle operation without performance drift
  • Full digital interface with dual-display TFT screens for independent monitoring of speed and temperature parameters
  • Comprehensive connectivity: RS232 and USB ports support instrument control, data logging, and integration into LIMS or ELN systems per FDA 21 CFR Part 11 requirements

Sample Compatibility & Compliance

The MATRIX Orbital Delta F2.0 accommodates standard 2.0 mL microcentrifuge tubes in a fixed 4 × 6 array—optimized for uniform thermal transfer and mechanical coupling. It is validated for use with common life science consumables including PCR tubes, LoBind Eppendorf-style tubes, and skirted assay plates (with optional adapters). The device complies with DIN EN 60529 (IP21), IEC 61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use), and electromagnetic compatibility standards EN 61326-1. Its firmware architecture supports audit-trail-enabled operation when connected to compliant software platforms, satisfying documentation requirements under ISO/IEC 17025, CLIA, and GxP-regulated environments.

Software & Data Management

Instrument parameters—including speed, temperature, time, and protocol sequences—are fully configurable via front-panel navigation or remote control using IKA LabWorld software (Windows-compatible). All operational events—including start/stop timestamps, parameter changes, error codes, and calibration logs—are timestamped and exportable as CSV or PDF reports. USB storage allows offline method saving and firmware updates. When interfaced via RS232, the shaker transmits real-time telemetry to third-party laboratory information management systems (LIMS), enabling traceable execution of SOPs and automated record generation aligned with 21 CFR Part 11 electronic signature and retention guidelines.

Applications

  • Pre-analytical sample homogenization for clinical diagnostics (e.g., whole blood, serum, plasma)
  • Thermal activation and incubation of restriction digests, ligations, and reverse transcription reactions
  • ELISA plate coating and wash-step agitation under controlled temperature
  • RNA/DNA extraction workflows requiring simultaneous lysis buffer mixing and heating
  • Stability studies of biopharmaceutical formulations under accelerated conditions
  • Microbial culture pre-incubation and reactivation prior to plating or sequencing

FAQ

What is the maximum tube volume supported by the standard block?
The unit is optimized for 2.0 mL microcentrifuge tubes; volumes up to 2.0 mL are supported, though optimal mixing efficiency is achieved at 0.2–1.5 mL fill levels.
Can the shaker operate without heating enabled?
Yes—the heating module can be deactivated independently while maintaining full speed and timing functionality for ambient-temperature shaking protocols.
Is calibration traceable to national standards?
Temperature and speed sensors are factory-calibrated; users may perform user-level verification using NIST-traceable reference thermometers and tachometers. Full recalibration services are available through authorized IKA service centers.
Does the device support external temperature probes?
No—the internal Pt100 sensor provides closed-loop control; no provision exists for external probe input.
What safety mechanisms prevent overheating or motor overload?
Integrated thermal cut-off switches, current-limiting circuitry, and real-time motor current monitoring trigger automatic shutdown if anomalies exceed defined thresholds—logged in the event history.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0