Smoke Density Chamber
Filter
Showing all 23 results
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | SDC-2 |
| Chamber Volume | 27 m³ (3 m × 3 m × 3 m) |
| Light Source | 12 V, 100 W quartz-halogen lamp (400–750 nm) |
| Photodetector | Silicon photodiode |
| Transmittance Range | 0.0001–100% |
| Accuracy | ±3% |
| Power Supply | 220–240 V AC, 50 Hz, 4 kW |
| Operating Ambient | 15–40 °C, RH ≤85%, no direct sunlight or forced airflow |
| Compliance | GB/T 17651.1–2, IEC 61034-1–2 |
| Ignition System | Integrated automatic alcohol-based ignition |
| Software | Proprietary Windows-based transmittance acquisition and reporting suite with real-time curve plotting and GLP-compliant data export |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SC-610 |
| Pricing | Available Upon Request |
| Standards Compliance | NFPA 258-T, ASTM E662, BS 6401, ATS 1000.001 |
| Internal Chamber Dimensions | 914 × 610 × 614 mm (L × W × H) |
| Radiant Heat Source | 900 W adjustable furnace, max irradiance 2.5 W/cm² |
| Multi-flame Combustion Burner | Integrated gas mixing flowmeter, temperature-controlled |
| Optical Path | Collimated light beam (λ = 550 nm), photometric detection of transmitted intensity |
| Sample Holders | Three motorized, precision-positioned fixtures with automated insertion/retraction |
| Exhaust System | Servo-controlled pneumatic damper with differential pressure sensor |
| Control Interface | Touch-enabled digital panel with real-time parameter monitoring and preset profile storage |
| Data Acquisition | PC-based software with automated optical density (Ds) calculation per ASTM E662 §7.3, time-resolved smoke density curves (Ds vs. t), and integrated area under curve (AUC) reporting |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NBS SMOKE CHAMBER |
| Pricing | Upon Request |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | SB 2005 |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Wall Finish | Enamel-coated steel |
| Radiation Source | Optional ISO 5659-2 compliant conical heater (0–50 kW/m²) |
| Photodetector | S4 spectral response photomultiplier tube (dark current <10⁻⁹ A) with silicon photodiode backup |
| Temperature Monitoring | Digital display with calibrated thermocouple |
| Data Acquisition | Integrated software compliant with ISO 5659-2 reporting requirements |
| Gas Sampling | Dedicated port for detector tubes (e.g., CO, HCl, HCN) |
| Calibration | NIST-traceable radiometric calibration certificate available for heat flux meter |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | ABD0031 |
| Application | Integrated with NBS-type smoke density chamber for aircraft cabin material qualification |
| Core Components | Vacuum chamber, vacuum pump, manual metering pump, gas analysis detector tubes |
| Compliance Context | Airbus ABD0031 specification, ASTM E662, ISO 5659-2, FAA AC 20-135, EN 45545-2 |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | NBS |
| Compliance | ASTM E662, ASTM F814, ISO 5659-2, NFPA 258, BS 6401, GB/T 8323, IMO FTPC Part 2, NES 711 |
| Chamber Dimensions | 914 mm × 914 mm × 610 mm (L×H×W) |
| Radiant Heat Flux Range | 10–50 kW/m² (calibrated at 25 kW/m² ±1 kW/m²) |
| Optical System | 6.5 V Tungsten Lamp + S-4 Spectral Response Photomultiplier Tube (dark current <10⁻⁹ A) |
| Light Beam Transmission Accuracy | 0.01% |
| Optical Density Resolution | 0.01 |
| Mass Loss Measurement Accuracy | ±0.1% |
| Timer Resolution | 0.1 s |
| Cone Heater Power | 2600 W |
| Thermocouples | Dual K-type armored (Cu/Alumel) |
| Heat Flux Meter | Thermopile-based, calibrated to ±1 kW/m² at 25 & 50 kW/m² |
| Ignition | Horizontal single-flame burner (30 mm ±5 mm), spark-ignited without chamber opening |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RSMD-A |
| Price | USD 1,580 (FOB Beijing) |
| Brand | Insment |
|---|---|
| Model | KS-8627B |
| Construction | 304 Stainless Steel Enclosure with Premium Powder Coating |
| Control System | PLC-Based Fully Automated Operation |
| Display | 7-inch Widescreen (16:9) TFT Color Touchscreen HMI |
| Light Source | 15 W, 6 V Incandescent Lamp with Cosine-Corrected Silicon Photodiode Detector |
| Optical Filter | Visible-Spectrum Bandpass (UV/IR Rejected) |
| Main Burner | Bunsen Burner (260 mm length, 0.13 mm orifice, 45° tilt), Operating Pressure: 276 kPa ±5 kPa |
| Auxiliary Burner | 138 kPa for Dripping Combustion |
| Flame Application Duration | 4 min (programmable) |
| Smoke Measurement Range | 0–100% Transmittance |
| SDR (Smoke Density Rating) Calculation | Integrated per ASTM D2843 & GB/T 8627 |
| Calibration Accuracy | ≤3% deviation using NIST-traceable neutral density filters |
| Focal Length After Optical Conditioning | 60–65 mm |
| Exhaust System | High-Capacity Fan + Activated Carbon Air Purification |
| Gas Supply | 85% Propane (user-supplied), with Integrated Gas Leak Detection and Interlock |
| Power Input | AC 220 V ±10%, 50 Hz |
| Compliance | ASTM D2843, GB/T 8627, ISO 5659-2 (optical path configuration compatible) |
| Brand | Marlin Engineering (MEI) |
|---|---|
| Origin | USA |
| Model | ME1100-1 |
| Compliance | FAA-recognized NBS-type smoke density chamber |
| Standards | FAA AC 20-135, BSS 7238, BSS 7239, AITM 2.0007, AITM 3.0005, HB 6577 |
| Temperature Control | PID-regulated radiant heating system |
| Optical Path | Fixed optical platform with calibrated photometric assembly |
| Light Source | Stable tungsten-halogen lamp with collimated beam |
| Transmittance Measurement Range | 0–100% (logarithmic smoke density scale: 0–1000 Ds) |
| Gas Sampling Interface | Four Swagelok® ports on chamber ceiling |
| Heat Flux Capability | 0–50 kW/m² (with traceable heat flux meter) |
| Sample Handling | Pneumatic specimen insertion mechanism |
| Ignition | Electronic spark ignition burner |
| Calibration | Three neutral density filters (certified OD values), stainless steel specimen holders (3× standard + 1 blank), gas flow and pressure regulation for controlled flaming combustion |
| Ancillary | Integrated smoke toxicity test kit (portable sampling pump, colorimetric detector tubes), real-time data acquisition system with ASTM/ISO-compliant reporting engine |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | 3MC |
| Chamber Volume | 27 m³ (3000 mm × 3000 mm × 3000 mm) |
| Compliance | IEC 61034, BS 6853, GB/T 17651.1–2 |
| Light Source | 2896 K tungsten halogen lamp with constant-current driver |
| Detector | Cosine-corrected silicon photodiode with color filter |
| Optical Resolution | 0.01% transmittance |
| Exhaust | Top-mounted centrifugal fan |
| Ignition | Remote-controlled surface igniter |
| Sample Support | Stainless steel alcohol tray and adjustable cable test stand |
| Data System | Integrated industrial touchscreen PC with thermal printer |
| Chamber Lining | PTFE-coated SUS 304 stainless steel interior |
| Viewing | Dual-side tempered glass ports and front observation window |
| Air Balance | Bottom perimeter ventilation openings |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SDB |
| Chamber Internal Dimensions | 914 mm × 914 mm × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001% |
| Radiation Sources | ASTM E662 radiant panel (25 kW/m²) and ISO 5659-2 conical heater (50 kW/m²) |
| Flame Sources | ASTM E662 pilot flame burner, ISO 5659-2 burner, NES 711 burner with mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Pressure Regulation | Top-mounted pressure relief port linked to calibrated volume bottle |
| Safety Features | Explosion-resistant aluminum foil lining, automatic pneumatic actuators for top/bottom access, full-front opening door |
| Cooling | Integrated recirculating water chiller with NIST-traceable water-cooled heat flux meter (50 kW/m² range) |
| Mass Loss Measurement | Built-in balance (0–2000 g, ±0.1 g) for MOD testing and thermogravimetric analysis |
| Calibration & Compliance | Compliant with ASTM E662, ISO 5659-2, NES 711 |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711 |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²) |
| Combustion Options | ASTM E662 flame burner, ISO 5659-2 flame burner, NES 711 flame burner + mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Safety Features | Explosion-resistant aluminum foil lining, pressure-relief port with calibrated volume bottle, dual pneumatic actuators (top/bottom), Teflon-coated interior walls |
| Data Acquisition | Integrated touchscreen PC with dedicated software, GLP-compliant audit trail, built-in thermal printer |
| Optional Modules | Dräger gas detection tubes (toxicity screening), FTIR coupling interface (smoke gas speciation), water-cooled Medtherm heat flux meter (NIST-traceable), wind-cooled copper calorimeter, integrated balance (0–5000 g, ±0.01 g) |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711 |
| Internal Chamber Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution: 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²), ISO 5659-2 conical heater (50 kW/m²), dual-standard flame burners |
| Temperature Control | External auxiliary heating jacket |
| Safety Features | Explosive-relief aluminum foil lining, pressure-regulated vent port with capacity bottle, top/bottom pneumatic actuators |
| Cooling | Integrated recirculating water chiller (MEDTHERM water-cooled heat flux meter included, NIST-traceable calibration certificate provided) |
| Weighing System | 0–5000 g capacity, 0.01 g readability |
| Optical Calibration | Motorized ND2 neutral density filter wheel with Clear/Filter/Dark auto-selection |
| Light Source | Uniform incandescent collimated beam |
| Data Interface | Touchscreen PC with integrated reporting and thermal gravimetric analysis (TGA) module |
| Optional Add-ons | Dräger gas detection tubes, FTIR coupling interface for smoke gas speciation |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | SDB |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical System | Side-window photomultiplier tube (PMT), S-4 spectral response, transmittance resolution 0.0001% |
| Radiation Sources | ASTM E662 radiant heater (25 kW/m²) and ISO 5659-2 conical heater (50 kW/m²) |
| Ignition Systems | ASTM E662 flame burner, ISO 5659-2 flame burner, NES 711 flame burner with mixing fan |
| Temperature Control | External auxiliary heating jacket for chamber thermal stabilization |
| Safety Features | Explosion-proof aluminum foil lining, pressure-relief port linked to calibrated volume bottle, dual pneumatic actuators (top/bottom), Teflon-coated interior walls |
| Cooling | Integrated recirculating water chiller (no external supply required), water-cooled MEDTHERM heat flux meter (NIST-traceable calibration) |
| Mass Measurement | Integrated balance, 0–5000 g range, 0.01 g resolution |
| Data Acquisition | Touchscreen PC-based control software with real-time transmittance logging, automated filter wheel (Clear/Filter/Dark/ND2), built-in thermal printer |
| Compliance | ASTM E662, ISO 5659-2, GB/T 8323, NES 711 |
| Brand | MOTIS |
|---|---|
| Model | SDB |
| Origin | Shanghai, China |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical Detection System | Side-window Photomultiplier Tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001% |
| Radiation Sources | ASTM E662 Radiant Panel (25 kW/m²) and ISO 5659-2 Radiant Cone (50 kW/m²) |
| Ignition Sources | ASTM E662 Flame Burner, ISO 5659-2 Flame Burner, NES 711 Flame Burner with Mixing Fan |
| Temperature Control | External Auxiliary Heating Jacket |
| Pressure Regulation | Automatic Pressure Relief Valve with Calibrated Volume Bottle |
| Safety Features | Explosion-Proof Aluminum Foil Liner, Top/Bot Pneumatic Cylinders, Full-Access Front Door |
| Cooling Options | Air-Cooled Copper Heat Flux Meter, Water-Cooled MEDTHERM Heat Flux Meter (NIST-traceable), Self-contained Recirculating Chiller |
| Mass Loss Measurement | Integrated Balance (0–5000 g, ±0.01 g) |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711, GB/T 8323 |
| Software | Integrated Touchscreen PC with Real-time Transmittance Logging, Report Generation, and Calibration Workflow |
| Optional Add-ons | Dräger Gas Detection Tubes, FTIR Coupling Interface for Smoke Toxicity & Speciation Analysis |
| Brand | MOTIS |
|---|---|
| Model | XP-2 |
| Standard Compliance | ASTM D2843 |
| Chamber Coating | PTFE (Teflon®) Interior |
| Light Source | Calibrated Incandescent Lamp |
| Photodetector | Cosine-Corrected Silicon Photodiode with Visible-Spectrum Bandpass Filter (380–780 nm) |
| Main Burner Pressure | 256 kPa |
| Auxiliary Burner | Integrated for Dripping Combustion Control |
| Data Acquisition Interval | 15 s |
| Output | SDR (Smoke Density Rating) Integral & Time-Resolved Curve |
| Software Features | Multi-sample SDR Overlay, Comparative Analysis, CFR 21 Part 11–Ready Report Export |
| Chamber Marking | High-Contrast “EXIT” Label on White Background |
| Viewing Window | Optical-Grade Quartz, UV/IR-Blocked |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | XP-2 |
| Compliance | ASTM D2843 |
| Chamber Coating | PTFE (Teflon®) Interior |
| Light Source | Calibrated Tungsten Filament Lamp |
| Detector | Cosine-Corrected Silicon Photodiode with Visible-Spectrum Bandpass Filter (380–780 nm) |
| Main Burner Pressure | 256 kPa |
| Auxiliary Burner | Integrated for Dripping Combustion Control |
| Data Acquisition Interval | 15 s |
| Output | SDR (Smoke Density Rating) Integral & Time-Resolved Curve |
| Software | ASTM-D2843-Compliant Reporting Suite with Multi-Sample Overlay, Comparative Analysis, and CFR 21 Part 11–Ready Audit Trail |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | XP-2 |
| Compliance | ASTM D2843 |
| Chamber Coating | PTFE (Teflon®) Interior |
| Light Source | Calibrated Incandescent Lamp |
| Detector | Cosine-Corrected Silicon Photodiode with Visible-Spectrum Filter (380–780 nm) |
| Primary Burner Pressure | 256 kPa |
| Auxiliary Burner | Integrated for Dripping Combustion Control |
| Data Acquisition | 15-s Interval Transmittance Logging |
| Output | SDR (Smoke Density Rating) Calculation & Multi-Sample Comparative Analysis |
| Software | Windows-Based, CFR Part 11 Compliant Audit Trail Optional |
| Chamber Viewing Window | Optical-Grade Quartz with EXIT Marking (White-on-Red) |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SBD |
| Price | USD 1,450 (FOB Tianjin) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TRDA Optical Smoke Density Measurement System |
| Light Source | 10 W halogen lamp, color temperature 2900 K |
| Beam Diameter | 22–500 mm |
| Photometric Linearity | < ±1.5% |
| Compliance | DIN 50055 |
| Control Interface | USB & RS232 |
| Integrated Computing | Single-board computer with Windows OS, TRDA software, high-resolution color touchscreen |
| Accessories Support | Compatibility with single-burner and bundled-cable fire testing configurations |
| Software Licensing | TRDA software — exclusive licensed implementation |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TRDL Helium-Neon Laser Smoke Density Tester |
| Light Source | He–Ne laser (632.8 nm) |
| Optical Path Length | 10 m (unobstructed) |
| Calibration Filters | Neutral density filters with OD 0.3 and 0.8 |
| Compliance | ISO 5660-2, ASTM E662, NFPA 265, UL 94, IEC 60695-2-2 |
| Interface | USB + RS232 |
| Control System | Integrated single-board computer with Windows OS, high-resolution color touchscreen, TRDL proprietary software |
| Brand | Newport |
|---|---|
| Origin | USA |
| Model | 4-5800 Series (ASTM E662 / FAA TSO-C135 Compliant) |
| Chamber Volume | 0.50 m³ |
| Optical Path Length | 914 mm |
| Sample Area | 0.0774 m² |
| Radiation Heat Flux | 2.5 W/cm² ±0.25 W/cm² |
| Power Supply | 230 V, 50–60 Hz |
| Dimensions (H×W×D) | 1956 × 1169 × 966 mm |
| Weight | 205 kg |
| Light Source | Tungsten-Halogen Lamp with ND2 Neutral Density Filter (Transmission Accuracy: 0.0001%) |
| Photodetector System | NIST-Traceable Silicon Photodiode Assembly |
| Data Acquisition | Real-time Transmittance vs. Time Plotting at 1 Hz Sampling Rate |
| Compliance | ASTM E662, ASTM F814, FAR 25.853, NFPA 258, BS 6401, FAA AC 20-135, ATS 1000.01, NES 711 |
| Brand | ZRTB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Model | JCY-3 |
| Price | USD 1,500 (approx.) |
| Compliance | GB/T 8627–2007, ASTM D2843 |
| Dimensions (L×W×H) | 740 × 500 × 900 mm |
| Weight | ~50 kg |
| Power Supply | 220 V ±10%, 50 Hz, 100 W |
| Operating Temp. | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Gas Source | 95% propane (user-supplied) |
| Burner Pressure (main) | 276 kPa (adjustable) |
| Burner Pressure (pilot) | 210 ±5 kPa |
| Flame Application Time | 4 min |
| Light Source | 15 W, 6 V incandescent lamp |
| Photodetector | Silicon photovoltaic cell |
| Optical Measurement Range | 0–100% transmittance |
| Accuracy | ±3% |
| Calibration | Triple NIST-traceable neutral density filters (±3% verification error) |
| Control Interface | 5″ TFT touchscreen (800×480), RS232, FPGA-driven real-time display |
| Automation | Auto-ignition, auto-timing, auto-exhaust control, staged linear photometric correction |
| Enclosure Requirement | Fume hood installation mandatory |
| Airflow Constraint | No forced convection during test |