Nitrogen Hydrogen Air Integrated Generator
Filter
Showing 1–30 of 37 results
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-T500 |
| Nitrogen Purity | ≥99.999% |
| Hydrogen Purity | ≥99.999% |
| Air Quality | Dew Point ≤−40 °C, Oil-Free, Particulate <0.01 µm |
| Nitrogen Flow Rate | 0–500 mL/min |
| Hydrogen Flow Rate | 0–500 mL/min |
| Air Flow Rate | 0–5000 mL/min |
| Output Pressure | 0–0.6 MPa (adjustable per gas stream) |
| Control System | Microprocessor-Based Digital Interface |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Power Consumption | 450 W |
| Dimensions | 450 × 440 × 400 mm |
| Weight | 35 kg |
| Operating Environment | 10–40 °C, RH ≤85% non-condensing |
| Brand | Hangzhou Chuanyi Electronic |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AYAN-T500 |
| Purity | 99.999% (N₂ & H₂) |
| Flow Rate | N₂: 0–500 mL/min |
| H₂ | 0–500 mL/min |
| Air | 0–5000 mL/min |
| Output Pressure | 0–0.5 MPa |
| Design | Integrated Monoblock Architecture |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BF-300 |
| Pricing | Available Upon Request |
| Nitrogen Purity | ≥99.999% (O₂ ≤1 ppm) |
| Hydrogen Purity | ≥99.999% (O₂ ≤1 ppm) |
| Air Purity | Oil-free, Class 3 filtration |
| Nitrogen Output Pressure | 0.4 MPa |
| Hydrogen Output Pressure | 0.3 MPa |
| Air Output Pressure | 0.4 MPa |
| Nitrogen Flow Rate | 0–300 mL/min |
| Hydrogen Flow Rate | 0–300 mL/min |
| Air Flow Rate | 0–2 L/min |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 350 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <85% RH |
| Dimensions (L×W×H) | 500 × 400 × 360 mm |
| Net Weight | 40 kg |
| Safety Features | Multi-stage pressure regulation, non-return liquid design, over-pressure/over-temperature protection, electrolyte level monitoring |
| Cooling | Passive convection |
| Electrolyte Requirement | Deionized or distilled water only |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | GC MATE |
| Gas Purity | 99.9996% (H₂), 99.999% (N₂), >99.999% (Air after purification) |
| Output Flow | N₂: 4000 mL/min, H₂: 600 mL/min, Air: 5000 mL/min |
| Output Pressure | 11 bar (H₂), 5 bar (N₂), 7–10 bar (Air input required) |
| Design | Modular Split-System |
| Control Interface | Physical Keypad + LCD Display (128×64 pixels) |
| Certifications | CE, CSA, FCC |
| Compliance | Designed for GLP/GMP environments |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | XYT-300 / XYT-500 / XYT-300G / XYT-500G |
| Nitrogen Purity | O₂ < 3 ppm, Dew Point < −70 °C |
| Nitrogen Flow | 0–500 mL/min |
| Nitrogen Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow | 0–500 mL/min |
| Hydrogen Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Flow | 0–5000 mL/min |
| Air Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Dimensions | 460 × 440 × 370 mm |
| Max Power Consumption | 450 W |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XYT-300 |
| Price | USD 2,750 (FOB Shanghai) |
| Nitrogen Purity | O₂ < 3 ppm, Dew Point < −70 °C |
| Nitrogen Flow | 0–300 mL/min |
| Nitrogen Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow | 0–300 mL/min |
| Hydrogen Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Flow | 0–2000 mL/min |
| Air Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Dimensions | 460 × 440 × 370 mm |
| Max Power Consumption | 400 W |
| Electrolyzer Warranty | 3 years |
| System Warranty | 1 year |
| Hydrogen Purity | 99.999% |
|---|---|
| Hydrogen Flow Rate | 0–500 mL/min |
| Hydrogen Output Pressure | 0.4 MPa |
| Air Flow Rate | 0–2000 mL/min |
| Air Output Pressure | 0.4 MPa |
| Power Consumption | 275 W |
| Dimensions (W×D×H) | 470 × 260 × 380 mm |
| Net Weight | 28 kg |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLT-300G |
| Nitrogen Purity | >99.999% |
| Hydrogen Purity | >99.999% |
| Air Quality | Oil-free, Dry, Triple-Purified |
| N₂/H₂ Flow Range | 0–300 mL/min |
| Air Flow Range | 0–2000 mL/min |
| H₂ Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| N₂ Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Air Output Pressure | 0–0.4 MPa |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | 400 W |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust |
| Dimensions (W×D×H) | 460 × 440 × 370 mm |
| Weight | 40 kg |
| Warranty | 1-year system warranty, 3-year electrolyzer warranty |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLT-300II |
| Nitrogen Purity | >99.999% |
| Hydrogen Purity | >99.999% |
| Air Quality | Oil-free, desiccated, triple-purified |
| N₂/H₂ Flow Range | 0–300 mL/min |
| Air Flow Range | 0–2000 mL/min |
| H₂ Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| N₂ Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Air Output Pressure | 0–0.4 MPa |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | 400 W |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust |
| Dimensions (W×D×H) | 460 × 440 × 370 mm |
| Weight | 40 kg |
| Warranty | 1-year full unit, 3-year electrolytic cell |
| Brand | Hailong |
|---|---|
| Model | HLT-500II |
| Gas Outputs | N₂, H₂, Air |
| N₂ & H₂ Purity | >99.999% |
| Air Quality | Oil-free, Dry, Triple-Purified |
| N₂/H₂ Flow Range | 0–500 mL/min |
| Air Flow Range | 0–5000 mL/min |
| N₂ Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| H₂ Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| Air Output Pressure | 0–0.4 MPa |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | 500 W |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust |
| Warranty | 1-year system warranty |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLA-300G, HLA-500G |
| Gas Purity | N₂ > 99.997%, H₂ > 99.999% |
| Output Flow | N₂/H₂: 0–300 mL/min (HLA-300G), 0–500 mL/min (HLA-500G) |
| Air | 0–2000 mL/min (HLA-300G), 0–5000 mL/min (HLA-500G) |
| Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) for all gases |
| Design | Integrated monoblock chassis |
| Control Mode | On/Off switch control |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max Power | 750 W (HLA-300G), 850 W (HLA-500G) |
| Dimensions | 460 × 310 × 670 mm |
| Weight | 47 kg |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust ambient |
| Brand | HLT |
|---|---|
| Origin | Shanghai, China |
| Model | HLT-300II, HLT-500II |
| Gas Purity | N₂ > 99.997%, H₂ > 99.999%, Air: oil-free, dried, triple-purified |
| Output Flow | N₂/H₂: 0–300 mL/min (HLT-300II) / 0–500 mL/min (HLT-500II) |
| Air | 0–2000 mL/min (HLT-300II) / 0–5000 mL/min (HLT-500II) |
| Output Pressure | H₂/N₂/Air: 0–0.5 MPa (factory-set at 0.4 MPa) |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max. Power | 450 W |
| Dimensions (W×D×H) | 460 × 310 × 670 mm |
| Weight | 39 kg |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust ambient |
| Brand | Hailong |
|---|---|
| Origin | Shanghai, China |
| Model | HLT-500G |
| Nitrogen Purity | >99.999% |
| Hydrogen Purity | >99.999% |
| Air Quality | Oil-free, Dry, Triple-Purified |
| N₂/H₂ Flow Range | 0–500 mL/min |
| Air Flow Range | 0–5000 mL/min |
| H₂ Output Pressure | 0–0.4 MPa (factory-set at 0.3 MPa) |
| N₂ Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Air Output Pressure | 0–0.4 MPa |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max Power Consumption | 500 W |
| Operating Environment | 10–40 °C, RH ≤85%, non-corrosive, low-dust |
| Warranty | 1-year full unit, 3-year electrolyzer |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGT-300/500 Integrated N₂–H₂–Air Generator |
| Nitrogen Purity | 99.994% (O₂ ≤ 60 ppm) |
| Hydrogen Purity | 99.999% (O₂ + H₂O ≤ 1 ppm) |
| Air Purity | Oil-free, Class 3 per ISO 8573-1 |
| Nitrogen Flow Rate | 0–300 mL/min (PGT-300) / 0–500 mL/min (PGT-500) |
| Hydrogen Flow Rate | 0–300 mL/min (PGT-300) / 0–500 mL/min (PGT-500) |
| Air Flow Rate | 0–2 L/min (PGT-300) / 0–5 L/min (PGT-500) |
| Output Pressure | 0.4 MPa (adjustable, stability ≤ ±0.01 MPa) |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 350 W (PGT-300) / 450 W (PGT-500) |
| Dimensions (L×W×H) | 505 × 400 × 460 mm |
| Weight | 40 kg (PGT-300) / 42 kg (PGT-500) |
| Operating Environment | 0–45 °C, RH < 85%, non-corrosive, low-dust |
| Water Requirement | Deionized or distilled water only |
| Design | Integrated monolithic chassis with independent gas modules and shared control logic |
| Hydrogen purity | 99.999% |
|---|---|
| Hydrogen flow rate | 0–300 mL/min |
| Hydrogen output pressure | 0.4 MPa |
| Air flow rate | 0–2000 mL/min |
| Air output pressure | 0.4 MPa |
| Power consumption | 275 W |
| Dimensions (W×D×H) | 470 × 260 × 380 mm |
| Net weight | ~28 kg |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UHAN1-1 |
| Gas Purity | 99.99996% (N₂), Zero Air (HC < 0.1 ppm, CO < 0.1 ppm, NOₓ < 0.1 ppm, SO₂ < 0.1 ppm, H₂O < 1 ppm) |
| Output Flow Rate | 1.2 L/min (combined or individually configurable) |
| Output Pressure Range | 0–7 bar (adjustable and pressure-stabilized) |
| Design | Integrated Monoblock Architecture |
| Control Interface | Intelligent Full-Color Touchscreen with Embedded IoT Module |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | UHAN2-1 |
| Gas Purity | 99.99996% (N₂) |
| Nitrogen Output Flow | 2 L/min |
| Output Pressure Range | 0–7 bar |
| Design | Integrated Monoblock Architecture |
| Control Interface | Intelligent Touchscreen HMI |
| Noise Level | <45 dB(A) |
| Core Technology | Imported PSA Molecular Sieve Modules + Oil-Free Compressor |
| Safety Features | Overpressure Protection, Automatic Pressure Relief |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | NHA-300 |
| Nitrogen Purity | ≥99.999% (O₂ < 3 ppm, Dew Point: −56 °C) |
| Nitrogen Flow Rate | 0–300 mL/min |
| Nitrogen Pressure | 0–0.4 MPa |
| Hydrogen Purity | ≥99.999% |
| Hydrogen Flow Rate | 0–300 mL/min |
| Hydrogen Pressure | 0–0.4 MPa |
| Air Flow Rate | 0–2000 mL/min |
| Air Pressure | 0–0.4 MPa |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Ambient Humidity | ≤85% RH |
| Noise Level | <40 dB(A) |
| Dimensions (W×D×H) | 500×480×360 mm |
| Weight | 40 kg |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | JP-300E |
| Gas Purity | N₂ ≥ 99.999%, H₂ ≥ 99.99995%, Air (HC < 0.1 ppm) |
| Output Flow | N₂: 0–500 mL/min, H₂: 0–500 mL/min, Air: 0–5 L/min |
| Output Pressure | N₂/H₂: 0.3 MPa, Air: 0.4 MPa |
| Design | Integrated monolithic chassis |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 550 W |
| Dimensions (L×W×H) | 480 × 420 × 480 mm |
| Weight | 45 kg |
| Operating Environment | 0–40 °C, RH < 85%, non-corrosive, low-dust ambient |
| Compliance | Designed for GLP-compliant GC laboratories |
| Brand | MNK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FID-1000 |
| Price | Upon Request |
| Hydrogen Purity | 99.9995% |
| Zero Air Total Hydrocarbons (as CH₄) | < 0.1 ppm |
| Max. H₂ Flow Rate | 90 cc/min |
| Max. Zero Air Flow Rate | 1000 cc/min |
| Input Power | 120 VAC, 60 Hz, 480 W |
| H₂ Outlet Pressure | 60 psig (414 kPa) |
| Zero Air Outlet Pressure | 40–125 psig (276–862 kPa) |
| Inlet Connection | 1/4" NPT (female) |
| Outlet Connection | 1/8" compression |
| Dimensions | 16.5" H × 10.5" W × 17" D (42 × 27 × 43 cm) |
| Weight | 53 lb (24 kg) |
| Minimum Inlet Air Pressure Requirement | 40 psig (276 kPa) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NA-300 |
| Pricing | Available Upon Request |
| Nitrogen Purity | <3 ppm O₂, Dew Point −56 °C |
| Nitrogen Flow Rate | 0–300 mL/min |
| Nitrogen Output Pressure | 0.4 MPa |
| Zero-Air Flow Rate | 0–2000 mL/min |
| Zero-Air Output Pressure | 0.4 MPa |
| Power Consumption | 275 W |
| Dimensions (W×D×H) | 470 × 260 × 380 mm |
| Net Weight | ~28 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NA-500 |
| Pricing | Available Upon Request |
| Nitrogen Purity | <3 ppm O₂, Dew Point −56 °C |
| Nitrogen Flow Rate | 0–500 mL/min |
| Nitrogen Output Pressure | 0.4 MPa |
| Zero-Air Flow Rate | 0–2000 mL/min |
| Zero-Air Output Pressure | 0.4 MPa |
| Power Consumption | 275 W |
| Dimensions (W×D×H) | 470 × 260 × 380 mm |
| Net Weight | ~28 kg |
| Nitrogen Purity | <3 ppm O₂, Dew Point −56 °C |
|---|---|
| Nitrogen Flow | 0–500 mL/min |
| Nitrogen Pressure | 0.4 MPa |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow | 0–500 mL/min |
| Hydrogen Pressure | 0.4 MPa |
| Air Flow | 0–2000 mL/min |
| Air Pressure | 0.4 MPa |
| Power Consumption | 330 W |
| Dimensions (W×D×H) | 350 × 350 × 500 mm |
| Net Weight | ~33 kg |
| Brand | PEAK |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Gas Generator |
| Model | GENIUS 3010 Series (Nitrogen-Hydrogen-Zero Air Integrated System) |
| Gas Purity | N₂ ≥ 99.9999%, H₂ ≥ 99.9999%, Total Hydrocarbons < 0.05 ppm |
| Flow Rates | N₂ up to 1000 cc/min, H₂ up to 1200 cc/min, Zero Air up to 7 L/min |
| Output Pressure | N₂ and Zero Air ≤ 80 psi (5.5 bar), H₂ ≤ 100 psi (6.9 bar) |
| Design Architecture | Stacked Modular Configuration |
| Control Interface | Intelligent Touchscreen with Embedded PLC Logic |
| Brand | Quanpu |
|---|---|
| Origin | Shanghai, China |
| Model | QPT-300ZD |
| Gas Purity | H₂ ≥ 99.999%, N₂ > 99.999% |
| Output Flow | H₂: 0–300 mL/min, Air: 0–2000 mL/min |
| Output Pressure | N₂: 0–0.5 MPa (factory-set at 0.4 MPa), H₂: 0–0.4 MPa (factory-set at 0.3 MPa), Air: 0–0.45 MPa (factory-set at 0.4 MPa) |
| Design | Integrated monoblock chassis |
| Control Mode | On/Off switch control |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Max Power Consumption | 500 W |
| Operating Environment | 0–40 °C, RH ≤85%, non-corrosive, low-dust ambient |
| Dimensions (L×W×H) | 560 × 430 × 360 mm (excl. 30 mm mounting flange) |
| Brand | Ruinen |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | RNT-300 |
| Nitrogen Purity | ≥99.999% |
| Hydrogen Purity | ≥99.999% |
| Nitrogen Flow Rate | 0–300 mL/min |
| Hydrogen Flow Rate | 0–300 mL/min |
| Air Flow Rate | 0–3000 mL/min |
| Output Pressure | 0–0.4 MPa |
| Pressure Stability | <±0.2% FS |
| Nitrogen & Hydrogen Reservoir Volume | 3 L each |
| Feed Water Resistivity Requirement | ≥1 MΩ·cm |
| Air Compressor Noise Level | <35 dB(A) |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Operating Temperature | 0–40 °C |
| Operating Humidity | <85% RH |
| Design | Integrated (All-in-One) Unit |
| Brand | XIUILAB |
|---|---|
| Origin | Shanghai, China |
| Model | XGT-300 / XGT-500 |
| Output Pressure | 0.4 MPa |
| Nitrogen Purity | 99.99% (O₂ < 100 ppm) |
| Hydrogen Purity | 100.00% (O₂-free, oil-free) |
| Air Purity | Oil-free, Class 3 compressed air per ISO 8573-1 |
| N₂ Flow Range | 0–300 mL/min (XGT-300) / 0–500 mL/min (XGT-500) |
| H₂ Flow Range | 0–300 mL/min (XGT-300) / 0–500 mL/min (XGT-500) |
| Air Flow Range | 0–2 L/min (XGT-300) / 0–5 L/min (XGT-500) |
| Power Supply | 220 V ±10%, 50 Hz |
| Max. Power Consumption | 350 W (XGT-300) / 450 W (XGT-500) |
| Operating Temperature | 0–45 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Dimensions (L×W×H) | 500 × 400 × 450 mm |
| Weight | 40 kg (XGT-300) / 42 kg (XGT-500) |
| Pressure Stability | ≤ ±0.01 MPa |
| Brand | XiYou |
|---|---|
| Origin | Shanghai, China |
| Model | XYAH-300 |
| Compressor Type | Domestic Diaphragm Compressor |
| Hydrogen Purity | 99.999% |
| Hydrogen Flow Rate | 0–300 mL/min |
| Output Pressure | 0–0.5 MPa (factory-set at 0.4 MPa) |
| Design | Integrated Monoblock |
| Air Filtration | Dual-stage pressure regulation + triple-stage filtration |
| H₂ Filtration | Triple-stage purification |
| Electrolyte System | Aqueous KOH-based alkaline electrolysis |
| Safety Features | Automatic anti-alkaline-backflow, overpressure relief valve, leak-tight gas path |
| Compliance | Designed for ISO/IEC 17025-compliant labs, compatible with GLP/GMP workflows requiring traceable gas supply |
| Brand | XiYou |
|---|---|
| Origin | Shanghai, China |
| Model | XYAH-300G (Equipped with Domestic Compressor) |
| Hydrogen Purity | ≥99.999% |
| Hydrogen Flow Rate | 0–300 mL/min |
| Air Flow Rate | 0–2000 mL/min |
| Air Output Pressure | 0–0.5 MPa (Factory-Set at 0.4 MPa) |
| Design | Integrated Monoblock Architecture |
| Filtration | Triple-Stage Hydrogen Filtration |
| Electrolyte System | Aqueous KOH-Based Alkaline Electrolysis |
| Safety Features | Automatic Anti-Backflow Alkali Protection |
| Compliance | Designed for GLP-compliant laboratory environments |