| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | HDT-VST-300E |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Heating Medium | Methyl Silicone Oil (up to 300 °C) or Transformer Oil (up to 200 °C) |
| Standard Config | 3 Test Stations |
| Load Application | Mechanical Deadweight via Precision Calibration Weights |
| Temperature Sensing | PT100 Platinum Resistance Thermometer |
| Deformation Sensing | High-Resolution Digital Micrometer Sensor (0–10 mm range, 0.001 mm resolution) |
| Control System | 32-bit ARM Embedded Processor with Real-Time Isothermal Ramp Algorithm |
| Compliance | ISO 75-1:1993, ISO 306:1994, GB/T 1633–2000, GB/T 1634–2001 |
| Brand | Beiguang Jingyi / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BGJY-200 |
| Max Test Load | 2000 N |
| Load Measurement Accuracy | ±2% FS (≥10% FS) |
| Load Repeatability | ≤2% FS (≥10% FS) |
| Friction Torque Range | 0–15 N·m |
| Torque Accuracy | ±3% FS (≥10% FS) |
| Torque Repeatability | ≤3% FS (≥10% FS) |
| Lower Specimen Shaft Speed | 0–400 rpm (infinitely variable) |
| Upper Specimen Shaft Speed | 0–360 rpm |
| Axial Travel of Upper Specimen | ±4 mm |
| Time Control Range | 1 s – 9999 min |
| Revolution Count Range | 1 – 999999 |
| Sample Dimensions | 30 mm × 7 mm × 6 mm |
| Standard Load | 196 N (±0.1%, extendable to 392 N) |
| Counterweight Configuration | One 4 kg + four 1 kg weights |
| Friction Ring | Ø40 × 10 mm, 45# steel, hardened to HRC 40–45, surface roughness Ra ≤ 3.2 µm, concentricity < 0.01 mm |
| Brand | Beiguang Jingyi / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BMc-200 |
| Price | USD 1,720 (FOB Beijing) |
| Brand | Beijing North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BWR-300A |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | 50 ±1 °C/h or 120 ±1 °C/h |
| Temperature Resolution | 0.01 °C |
| Max. Temperature Accuracy | ±0.5 °C |
| Deformation Measurement Method | Digital Dial Gauge (Grating-based) |
| Deformation Range | 0–5.0 mm |
| Deformation Accuracy | ±0.001 mm |
| Sample Stations | 3 independent test stations per bath |
| Heating Medium | Methyl silicone oil (flash point ≥300 °C, kinematic viscosity 200 cSt at 25 °C, 20 L required) |
| Heating Power | 2.5 kW |
| Cooling Method | Natural cooling above 150 °C |
| Overtemperature Protection | Adjustable upper limit (ambient to 300 °C) with hardware cutoff at 300 °C |
| Load Rod + Indenter Mass | 88 g |
| Test Loads | Vicat A = 10.0 N ±0.2 N |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Compliance Standards | GB/T 1633, GB/T 1634, GB/T 8802, ISO 306:2020, ISO 75-1:2013, ISO 75-2:2017 |
| Brand | INSTRON |
|---|---|
| Origin | Italy |
| Manufacturer | CEAST (INSTRON Group) |
| Model Variants | HV3S, HV6M, HV6X, HV500 |
| Temperature Range | Up to 500 °C (HV500) |
| Standard Range | 20–300 °C (HV3S/HV6M/HV6X) |
| Load Application | Manual (HV3S), Semi-Automated (HV6M), Fully Automated (HV6X), Fluidized Bed (HV500) |
| Test Stations | 3 (HV3S), 6 (HV6M/HV6X), 1 (HV500) |
| Compliance | ASTM D648, ASTM D1525, ISO 75-1/2/3, ISO 306, ISO 10350-1, GB/T 1634, GB/T 1633 |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LDS-3000 |
| Load Cell Capacity | 3000 N |
| Load Accuracy | ±1% FS |
| Load Resolution | 0.5 N |
| Test Speed Range | 5–300 mm/min |
| Speed Accuracy | ±5% |
| Effective Stroke | 300 mm |
| Displacement Measurement Range | 0–300 mm |
| Displacement Accuracy | ±1% FS |
| Platen Dimensions | 310 × 310 mm |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | WKW-300 |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Rates | 5 ±0.5 °C/6 min (Method A), 12 ±1.0 °C/6 min (Method B) |
| Deformation Measurement Range | 0–1 mm |
| Deformation Accuracy | ±0.005 mm |
| Dial Indicator Resolution | 0.001 mm (±0.003 mm accuracy) |
| Test Loads | 10 N ±0.2 N (VST Method A), 50 N ±1 N (VST Method B) |
| Bending Stress Levels | 0.45 MPa (HDT Method B), 1.80 MPa (HDT Method A), 8.00 MPa (HDT Method C) |
| Span Lengths | 64 mm and 100 mm |
| Heating Medium | Methyl silicone oil (kinematic viscosity ≤200 cSt, flash point ≥300 °C) |
| Cooling Options | Natural convection or water cooling |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 4 kW |
| Accuracy Class | Class 1 (per GB/T 1633 & ISO 306) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DRK160 |
| Heating Medium | Methyl Silicone Oil |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Rates | 5 ±0.5 °C/6 min (Method A), 12 ±1.0 °C/6 min (Method B) |
| Penetration Measurement Range | 0–1 mm |
| Digital Micrometer Accuracy | ±0.003 mm |
| Deformation Resolution | ±0.005 mm |
| Test Loads | 10 N ±0.2 N (GA), 50 N ±1 N (GB) |
| Max. Heating Power | ≤3000 W |
| Power Supply | 220 V, 50 Hz, 30 A |
| Span Options | 64 mm, 100 mm, or Continuously Adjustable |
| Sample Orientation | Horizontal |
| Temperature Uniformity | ±0.5 °C (achieved via 45° dual-helix automatic oil stirring) |
| Safety Features | Upper-temperature cutoff, overflow oil recovery system |
| Cooling Options | Natural air cooling, water cooling, or liquid nitrogen cooling |
| Optional | Motorized test frame lift mechanism |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Region Category | Domestic |
| Model | RV-300F Heat Deflection Temperature and Vicat Softening Temperature Tester |
| Temperature Control & Measurement Range | Ambient to 300 °C |
| Heating Rate Options | 120 ± 10 °C/h (12 ± 1 °C/6 min) or 50 ± 5 °C/h (5 ± 0.5 °C/6 min) |
| Temperature Accuracy | ±0.5 °C |
| Deformation Measurement Range | 0–10 mm |
| Deformation Resolution | ±0.01 mm |
| Test Stations | 6 independent, motorized sample holders with automatic vertical positioning |
| Load Rod + Plunger + Dial Indicator Assembly Mass | 71 g |
| Heating Medium | Methyl silicone oil (flash point ≥ 50 °C above test temperature) or other media specified in ISO/ASTM/GB standards |
| Heating Power | 3 kW |
| Cooling Method | Water-cooled below 150 °C |
| Power Supply | 220 V ± 10%, 10 A, 50 Hz |
| Safety Features | Programmable upper temperature limit with audible/visual alarm and automatic heater cutoff |
| Display | Backlit LCD with Chinese interface (temperature, setpoint, real-time curve, auto-log) |
| Fume Extraction | Integrated active fume removal system for silicone oil vapors |
| Compliance | ISO 75-1/2/3, ISO 306, ASTM D648, ASTM D1525, GB/T 1633, GB/T 1634, GB/T 8802 |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Model | HV-3000-P3C |
| Compliance Standards | ASTM D1525, ASTM D648, ISO 306, ISO 75, DIN 53460, DIN 53461 |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Deformation Measurement Range | 0.001–3.500 mm (LVDT-based) |
| Specimen Span Options | 64 mm, 100 mm, 101.6 mm |
| Stirring Method | Eddy-current magnetic stirring |
| Cooling Options | External tap water + optional rapid low-temperature cooling system |
| Dimensions (W×D×H) | 108 × 55 × 150 cm |
| Weight | ~200 kg |
| Power Supply | 1-phase, 220 V, 50 Hz |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Model | GCRBWK-300A4 |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Rates | 50 °C/h or 120 °C/h (adjustable between 50–120 °C/h) |
| Temperature Resolution | 0.001 °C |
| Deformation Measurement Range | 0–10 mm |
| Deformation Accuracy | ±0.005 mm |
| Deformation Resolution | 0.001 mm |
| Number of Test Stations | 4 |
| Support Span Options | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Test Frame | <0.005 /100 °C |
| Temperature Sensing Points | 4 |
| Heating Power | 4000 W |
| Bath Medium | Methyl Silicone Oil or Transformer Oil |
| Cooling Method | Natural cooling above 150 °C |
| Control Architecture | Distributed MCU + PC System |
| Safety Protections | Dual hardware/software temperature limit switches, auto-stop on test completion, administrator access control |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | JH-6020B |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | 120 °C/h or 50 °C/h |
| Temperature Control Accuracy | ±1 °C (VST), ±2 °C/6 min (HDT) |
| Temperature Measurement Accuracy | ±0.5 °C |
| Deflection Measurement Resolution | 0.001 mm |
| Max Deflection Error | ±0.005 mm |
| Vicat Penetration Depth | 1.00 mm ±0.01 mm |
| Standard Test Loads | 10 N, 50 N (VST) |
| Bending Stresses | 0.45 MPa (Method B), 1.80 MPa (Method A), 8.00 MPa (Method C) (HDT) |
| Sample Supports | 3 independent test frames with selectable spans (64 mm for flatwise placement |
| Heating Medium | Methyl silicone oil (kinematic viscosity ≤200 cSt |
| Max Heating Power | 3 kW |
| Cooling Method | Natural convection |
| Power Supply | 220 V ±10%, 50 Hz, 15 A |
| Compliant Standards | GB/T 1633–2000 (ISO 306:1994), GB/T 1634.1–2004 (ISO 75-2:2003), GB/T 1634.2–2004, GB/T 1634.3–2004, GB/T 8802–2001 (ISO 2507:1995), ASTM D1525, ASTM D648 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-282 |
| Temperature Control Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate Options | 5 ±0.5 °C/6 min (ISO 75–1 Method A) or 12 ±1 °C/6 min (ISO 75–1 Method B) |
| Vicat Load | 10 N ±0.2 N (Method A) or 50 N ±1 N (Method B) |
| Deflection Measurement Range | 0–1 mm |
| Deflection Resolution | ±0.001 mm |
| Standard Span Lengths | 64 mm and 100 mm |
| Heating Power | ≤3800 W |
| Compliant with GB/T 1633–2000, GB/T 1643–1979, ISO 75–1 | 2013, ISO 306:2020 |
| Brand | Kegel |
|---|---|
| Origin | Germany |
| Model | HDT Vicat 4U |
| Temperature Range | 5°C above ambient to 285°C |
| Temperature Stability | ±0.2°C to ±0.3°C (100–250°C) |
| Heating Rates | 50°C/h ±5°C/h and 120°C/h ±10°C/h |
| Temperature Sensor | Calibrated Pt100 per test station |
| Displacement Resolution | 0.01 mm (LVDT) |
| Test Stations | Up to 4 |
| Cooling Method | Water-cooled |
| Power Supply | 230 V, 50 Hz, ~3 kW |
| Dimensions (W×H×D) | 1020 × 690 × 520 mm |
| Weight | ~75 kg |
| Software | k-BASE for Windows |
| Compliance | ISO 75-1/2, ISO 306, ASTM D648, D1525, E77, E608, E644, E1137, DIN 43760, 53460, 53461/87, UNI 5641, 5462, BSI 2782, AFNOR NT T51-005/T51.021, UNE 53075/53118 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BWR |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Heating Power | 2.5 kW |
| Heating Medium | Methyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt, 20 L required) |
| Sample Stands | Three independent test stations per bath |
| Deformation Measurement | Linear encoder-based dial indicator (resolution 0.001 mm, accuracy ±0.01 mm) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Heating Rates | 120 ±5 °C/h (12 ±1 °C/6 min) or 50 ±3 °C/h (5 ±0.5 °C/6 min) |
| Deformation Range | −0.1 to 5.0 mm |
| Cooling Method | Natural convection above 150 °C |
| Maximum Settable Temperature | 300 °C with over-temperature cut-off |
| Load Rod + Indenter Mass | 88 g |
| Standard Loads | Vicat GA = 10.0 N ±0.2 N (1000 g), GB = 50.0 N ±1.0 N (5000 g) |
| HDT fiber stress options | 0.45 MPa (Method B), 1.80 MPa (Method A), 8.00 MPa (Method C) |
| Compliance | ASTM D1525, ASTM D648, ISO 306:2004, ISO 75-1:2013, GB/T 1633–2000, GB/T 1634.1–2004, GB 8802 |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | HDT/VICAT |
| Maximum Temperature | 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤0.2 °C |
| Temperature Stability (Oil Bath Fluctuation) | ±0.2 °C |
| Heating Rates | 50 °C/hr, 120 °C/hr, or Custom |
| Displacement Resolution | 0.001 mm |
| Displacement Accuracy | <0.01 mm |
| Sample Immersion Depth | ≥35 mm |
| Span Between Supports (HDT) | 100 mm (optional 64 mm) |
| Sample Length (HDT) | Up to 102 mm |
| Test Stations | 6 independent positions |
| Weight Load Range | 1–2048 g (binary HDT weights), plus 10 N and 50 N VICAT needles |
| Cooling System | Integrated stainless-steel water-jacketed oil bath with external 18 °C coolant |
| Safety Features | Nitrogen purge interface, physical barrier (mesh screen) between heating/stirring components and sample zone, dual stirrers and heater isolated from test chamber |
| Compliance | ASTM D648, ASTM D1525, ISO 75-1/2/3, ISO 306, GB/T 1634, GB/T 1633, DIN 53461 |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HSY-8146H |
| Temperature Range | Ambient to 162 °C |
| Temperature Resolution | 0.1 °C |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Model | HRWK-300 |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 50 °C/h and 120 °C/h |
| Deformation Measurement Range | −1.000 mm to +10.000 mm |
| Vicat Needle Tip Area | 1.00 ± 0.015 mm² |
| Sample Holder Thermal Expansion Coefficient | < 0.005 mm/100 °C |
| Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 306, ISO 75, ISO 2507, ASTM D 1525, ASTM D 648 |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Model | SWB-300A/B |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | 5 ± 0.5 °C/6 min or 12 ± 1.0 °C/6 min |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C across bath |
| Bath Volume | 25 L |
| Test Stations | 3 |
| Deformation Measurement | Dial Gauge (0.01 mm resolution) |
| HDT Indenter Radius | R = 3.0 ± 0.2 mm |
| HDT Span Length | 100 ± 0.5 mm |
| Load Rod Mass | 88.35 g |
| Vicat Needle Cross-Sectional Area | 1.000 ± 0.015 mm² (d = 1.128 ± 0.0085 mm) |
| Thermal Expansion of Test Frame | ≤ 0.01 mm (with correction value provided if exceeded) |
| Heating Power | 4 kW |
| Power Supply | 220 VAC, 20 A |
| Dimensions (L×W×H) | 830 × 500 × 540 mm |
| Net Weight | SWB-300A — 58 kg |
| Optional Feature | Motorized Lift Mechanism (SWB-300B only) |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Model | SWB-300C |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 5 ± 0.5 °C/6 min or 12 ± 1.0 °C/6 min |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C across 3 sensing points |
| Bath Volume | 25 L |
| Test Stations | 3 |
| Displacement Resolution | 0.01 mm |
| Vicat Needle Cross-Section | 1.000 ± 0.015 mm² (d = 1.128 ± 0.0085 mm) |
| HDT Probe Radius | R = 3.0 ± 0.2 mm |
| HDT Support Span | 100 ± 0.5 mm |
| Load Rod Mass | 88.35 g |
| Max. Thermal Expansion of Fixture | ≤0.01 mm (automatically compensated) |
| Heating Power | 4 kW |
| Power Supply | 220 VAC, 20 A |
| Dimensions (L×W×H) | 830 × 500 × 540 mm |
| Net Weight (C-type) | 58 kg (excl. heat transfer oil) |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TY-5006HA |
| Temperature Control Range | RT–300 °C |
| Heating Rate Options | (120±10) °C/h or (50±5) °C/h |
| Temperature Resolution | 0.1 °C |
| Deformation Measurement Range | 0–1.5 mm |
| Deformation Accuracy | ±0.001 mm |
| Sample Supports | 3 independent test stations |
| Support Span Options | 64 mm or 100 mm |
| Load Rod Mass | 68 g |
| Heating Power | 2.4 kW |
| Dimensions | 540 × 520 × 970 mm |
| Calibration Medium | Methyl silicone oil (200 cSt) or transformer oil |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TY-5006HB |
| Temperature Range | RT to 300 °C |
| Heating Rate Options | (120±10) °C/h, (12±1) °C/6 min, (50±5) °C/h, (5±0.5) °C/6 min |
| Temperature Accuracy | ±0.1 °C |
| Deformation Measurement Range | 0–1.5 mm |
| Deformation Resolution | ±0.001 mm |
| Sample Support Span | 64 mm or 100 mm |
| Load Rod Mass | 68 g |
| Thermal Expansion Coefficient of Test Frame | <0.005 mm/100 °C |
| Heating Power | 4 kW |
| Dimensions (W×D×H) | 540 mm × 520 mm × 970 mm |
| Standard Compliant | GB/T 1633, GB/T 1634.1–3, GB/T 8802, ISO 306:2023, ISO 75-1–3:2013, ASTM D1525, ASTM D648, ISO 2507:2017 |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | TY-5006HB |
| Temperature Range | RT–300 °C |
| Heating Rate Options | (120±10) °C/h, (12±1) °C/6 min, (50±5) °C/h, (5±0.5) °C/6 min |
| Temperature Accuracy | ±0.1 °C |
| Deflection Measurement Range | 0–1.5 mm |
| Deflection Resolution | ±0.001 mm |
| Sample Supports | 3 independent test stations |
| Support Span Options | 64 mm or 100 mm |
| Load Rod Mass | 68 g |
| Thermal Expansion Coefficient of Test Frame | <0.005 mm/100 °C |
| Heating Power | 2.4 kW |
| Dimensions | 540 × 520 × 970 mm |
| Calibration Medium | Methyl silicone oil (200 cSt) or transformer oil |
| Cooling Method | Natural convection above 150 °C |
| Standard Compliant | GB/T 1633, GB/T 1634.1–3, GB/T 8802, ISO 306:2022, ISO 75-1:2013, ISO 75-2:2013, ISO 75-3:2013, ASTM D1525, ASTM D648, ISO 2507:2016 |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-5006UB |
| Temperature Control Range | RT–300 °C |
| Heating Rate Options | (120±10) °C/h, (12±1) °C/6 min, (50±5) °C/h, (5±0.5) °C/6 min |
| Temperature Accuracy | ±0.1 °C |
| Deflection Measurement Range | 0–1.5 mm |
| Deflection Resolution | ±0.001 mm |
| Sample Support Span | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Sample Holder | <0.005 mm/100 °C |
| Heating Medium | Methyl Silicone Oil (200 cSt) or Transformer Oil |
| Heating Power | 2.4 kW |
| Dimensions | 540 mm × 520 mm × 970 mm |
| Test Stations | 3 independent stations |
| Load Rod Mass | 60 g (W-code) |
| Standard Weights | A (1000 g ×12), B (900 g ×3), C (500 g ×3), D (200 g ×6), E (100 g ×3), F (50 g ×3), G (20 g ×6), H (10 g ×3), I (5 g ×3), T (2 g ×6) |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | 603HDTV, 303HDTV |
| Compliance Standards | ISO 75-1/2, ISO 306, ASTM D648, ASTM D1525 |
| Maximum Simultaneous Test Positions | 6 (603HDTV), 3 (303HDTV) |
| Oil Bath Stations | 6 (603HDTV), 3 (303HDTV) |
| Load Application | Pneumatic vertical loading with air-bearing guide ring |
| Displacement Resolution | 0.001 mm |
| Load Accuracy | Certified for 0.45 MPa (ISO 75) and 1.0 MPa / 5.0 MPa (ISO 306) |
| Cooling System | Integrated heat exchanger (603HDTV) |
| Software | Horizon HDV with SPC, audit trail, CFR 21 Part 11–ready configuration options |
| Data Export Formats | HTML, CSV, PDF |
| Password Protection | Dual-level authentication |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TY-5006UA |
| Temperature Control Range | RT to 300 °C |
| Heating Rate Options | (120 ± 10) °C/h or (50 ± 5) °C/h |
| Temperature Resolution | 0.1 °C |
| Deformation Measurement Range | 0–1.5 mm |
| Deformation Accuracy | ±0.001 mm |
| Sample Support Span | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Test Frame | < 0.005 mm/100 °C |
| Load Rod & Platter Mass | 68 g |
| Heating Power | 4 kW |
| Dimensions (W × D × H) | 540 × 520 × 970 mm |
| Cooling Method | Natural cooling above 150 °C |
| Bath Medium | Methyl silicone oil (kinematic viscosity ~200 cSt) or transformer oil |
| Test Stations | 3 independent stations |
| Standard Compliance | GB/T 1633, GB/T 1634.1–3, GB/T 8802, ISO 306:2013, ISO 75-1–3:2003, ASTM D1525, ASTM D648 |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WKW-300 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Rates | 5 ±0.5 °C/6 min (Method A), 12 ±1.0 °C/6 min (Method B) |
| HDT Deformation Range | 0–0.5 mm |
| Vicat Penetration Range | 0–1 mm |
| Dial Indicator Accuracy | ±0.005 mm |
| Vicat Needle | 3 mm length, cross-sectional area 1.000 ±0.015 mm² |
| HDT Probe Fillet Radius | 3.0 ±0.2 mm |
| Max HDT Load | 5 kgf (≈49.0 N) |
| Vicat Loads | GA = 10 N ±0.2 N, GB = 50 N ±1 N |
| Max Heating Power | ≤4000 W |
| Electrical Supply | 220 V, 50 Hz, 30 A |
| HDT Span Lengths | 64 mm and 100 mm |
| Accuracy Class | Class 1 |
| Cooling Options | Natural convection or water-cooled |
| Over-Temperature Protection | Programmable upper limit |
| Compatible Heat Transfer Medium | Methyl silicone oil (flash point ≥300 °C, kinematic viscosity ≈200 cSt) |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.148-HD-500 |
| Max Operating Temperature | 500 °C |
| Test Standard Compliance | ASTM D648, ASTM D1525, ISO 75-1, ISO 306, JIS K7191-1, JIS K7206, GB/T 1633, GB/T 1634 |
| Construction Material | Fused Quartz Enclosure |
| Configuration | Sealed Gas-Bath Heating System |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.148-HD-PC |
| Standards Compliance | ASTM D648, D1525 |
| Heating Rate (HDT/Vicat) | 120 ± 10 °C/hr |
| Bending Stress Options | 0.45 MPa (ISO B / ASTM), 1.80 MPa (ISO A / ASTM), 8.00 MPa (ISO C) |
| Load Force Options | DTUL: 76.5–3210 gf |
| Vicat | 10 ± 0.2 N or 50 ± 1 N |
| Ball Pressure | 19.6–20 N |
| Penetrator Geometry | DTUL: R3.0 ± 0.2 mm |
| Vicat | 1.000 ± 0.015 mm² flat-ended needle |
| Ball Pressure | 5 mm diameter spherical tip |
| Span Length | 64 ± 1 mm or 100 ± 1 mm (standard) |
| Displacement Resolution | 0.001 mm (LVDT-based, 4 mm stroke) |
| Max Temp | 300 °C (silicone oil bath) |
| Oil Volume | ~10 L (3-station), ~12 L (4-station), ~17 L (6-station) |
| Cooling | Optional integrated refrigerated chiller (HDA series) |
| Software | Windows 10–compatible proprietary control & analysis suite |
| Power Supply | Single-phase 200/220 V, 20 A (3/4 stations) or 30 A (6 stations) |
| Dimensions (Floor-standing) | W1100 × D700 × H1500 mm |
| Weight | 180–300 kg |
| Dimensions (Bench-top) | W1100 × D700 × H1000 mm |
| Weight | 155–185 kg |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.148-HDA |
| Standards Compliance | JIS K7191-1, K7206 |
| Max Temperature | 300 °C (oil bath) |
| Heating Rate | 120 ± 10 °C/hr (HDT/Vicat), 50 ± 5 °C/hr (Vicat optional) |
| Bending Stress Options | 0.45 MPa (ISO B), 1.80 MPa (ISO A), 8.00 MPa (ISO C), 0.455 MPa / 1.82 MPa (ASTM) |
| Load Range | DTUL: 76.5–3,210 gf (2 selectable) |
| Vicat | 10 ± 0.2 N or 50 ± 1 N |
| BP | 19.6–20 N |
| Penetrator Tip Geometry | DTUL: R3.0 ± 0.2 mm |
| Vicat | 1.000 ± 0.015 mm² flat-ended |
| BP | Ø5 mm spherical |
| Deflection Resolution | 0.001 mm (differential sensor, 4 mm stroke) |
| Span Lengths | 64 ± 1 mm, 100 ± 1 mm (standard), 101.6 ± 0.5 mm (optional) |
| Sample Capacity | Up to 120 specimens (40 × 3 trays) |
| Oil Volume | ~10 L (3/4-station), ~17 L (6-station) |
| Cooling | Integrated refrigerated chiller (standard on HDA variant) |
| Stirring | Paddle-type agitator (2 units for 3/4 stations |
| Power Supply | With chiller — 3-phase AC200/220 V, 20 A / 30 A, 50/60 Hz |
| Air Supply | ≥0.5 MPa |
| Dimensions (W×D×H) | ~1460 × 900 × 1715 mm |
| Weight | 450–550 kg |