| Brand | Campbell |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SI-111 |
| Instrument Type | Fixed-Mount Infrared Radiometer |
| Measurement Range | -40 to 70°C |
| Accuracy | ±0.2°C (-10 to 65°C), ±0.5°C (-40 to 70°C) |
| Consistency | ±0.1°C (-10 to 65°C), ±0.3°C (-40 to 70°C) |
| Repeatability | ±0.05°C (-10 to 65°C), ±0.1°C (-40 to 70°C) |
| Spectral Response | 8–14 µm |
| Field of View | 22° half-angle |
| Response Time | <1 s |
| Operating Environment | -55 to 80°C, 0–100% RH |
| Excitation Voltage | 2.5 VDC |
| Thermopile Output | 60 µV/°C (ΔT between target and sensor body) |
| Thermistor Output | 0–2500 mV |
| Signal Channels | One differential (thermopile), one single-ended (thermistor) |
| Dimensions | 2.3 cm (diameter) × 6 cm (length) |
| Weight | 190 g |
| Brand | Apogee Instruments |
|---|---|
| Origin | USA (Manufactured in Logan, UT) |
| Model | SI-111 |
| Output Type | Analog Voltage (Non-Amplified) |
| Field of View | 22°30′ |
| Spectral Range | 8–14 µm |
| Measurement Range | −60 °C to +110 °C |
| Calibration Uncertainty | ±0.2 °C (−20 °C to +65 °C) |
| Response Time (95%) | 0.6 s |
| Sensitivity | 60 µV/°C |
| Thermopile Output Range | −3.3 mV to +3.3 mV |
| Thermistor Output Range | 0–2500 mV (excitation-dependent) |
| Excitation Voltage | 2500 mV (typ.) |
| Operating Environment | −55 °C to +80 °C, 0–100% RH (non-condensing) |
| Housing | Marine-grade stainless steel (IP68 connector at sensor head) |
| Dimensions | Ø23 mm × 60 mm |
| Mass | 190 g (incl. 5 m cable) |
| Cable | 5 m, 4-conductor, shielded twisted-pair, TPR jacket (UV-stable, hydrophobic, low-temp flexible) |
| Long-term Drift | <2% per year (with clean germanium window) |
| Warranty | 4 years |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CMSS 2020 |
| Temperature Range | −18 °C to +260 °C |
| Accuracy | ±3 °C (−18 °C to −1 °C) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | CWH1350 |
| Price Range | USD 1–9,999 |
| Instrument Type | Portable |
| Temperature Range | −50°C to 1350°C |
| Basic Accuracy | ±2.0°C |
| Temperature Resolution | 0.1°C / 0.1°F |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 increments) |
| Response Time | <150 ms |
| Laser Aiming | Single-point Class II diode laser (λ = 630–670 nm, output <1 mW) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 50:1 |
| Repeatability | ±0.5% of reading or ±1°C (±1.8°F) |
| Operating Temperature | −20°C to +50°C |
| Storage Temperature | −40°C to +60°C |
| Units | °C / °F selectable |
| Power Supply | 8.0–10.0 VDC |
| Current Consumption | ≤80 mA |
| Enclosure Rating | IP65 |
| Certification | Certified intrinsically safe per GB 3836.1–2010 and GB 3836.4–2010 (Explosion-proof Certificate No. attached to product documentation) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CWH600 |
| Price Range | USD 1–1,400 |
| Instrument Type | Portable |
| Temperature Range | −50 °C to 650 °C |
| Basic Accuracy | ±1.5 °C |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Emissivity Adjustment | 0.10–1.00 (step 0.01) |
| Response Time | <400 ms |
| Laser Aiming | Dual Class II Diode Lasers (λ = 630–670 nm, P<1 mW) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 12:1 |
| Repeatability | ±0.5% of reading or ±1 °C (±1.8 °F) |
| Operating Temperature | −10 °C to 50 °C |
| Storage Temperature | −20 °C to 60 °C |
| Display Units | °C / °F switchable |
| Power Supply | 8.0–10.0 V DC |
| Current Draw | ≤80 mA |
| Enclosure Rating | IP54 |
| Certification | MA Certified (China MSHA-equivalent), Ex ib I Mb Intrinsically Safe Mark, CNEX Test Report No. attached |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | cWH850 |
| Price Range | USD 1–1,400 |
| Instrument Type | Portable |
| Temperature Range | −50°C to 850°C |
| Accuracy | ±1.5°C |
| Temperature Resolution | 0.1°C / 0.1°F |
| Emissivity Adjustment | 0.10–1.00 (adjustable) |
| Response Time | <400 ms |
| Laser Aiming | Dual Class II laser (630–670 nm, <1 mW) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 16:1 |
| Repeatability | ±0.5% of reading or ±1°C (±1.8°F) |
| Operating Temperature | −10°C to +50°C |
| Storage Temperature | −20°C to +60°C |
| Display | Backlit LCD with °C/°F toggle |
| Power Supply | 8.0–10.0 VDC, ≤80 mA |
| IP Rating | IP54 |
| Dimensions | 160 × 82 × 41.5 mm |
| Weight | 180 g |
| Data Logging | Optional internal storage for up to 20 readings |
| Alarm Functions | High/Low temperature threshold alert (HAL/LAL) |
| Measurement Modes | Max/Min/DIF/AVG, Hold, Trigger Lock |
| Auto Power-Off | Yes |
| Laser On/Off Switch | Yes |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fluke 62 |
| Pricing | Available Upon Request |
| Emissivity | Fixed at 0.95 |
| Temperature Resolution | 0.2°C |
| Distance-to-Spot Ratio | 10:1 |
| Measurement Range | −30°C to 500°C |
| Accuracy | ±1.5% of reading or ±1.5°C (whichever is greater) |
| Repeatability | ±0.5% of reading or ±1°C (whichever is greater) |
| Response Time | <500 ms |
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | −20°C to 65°C |
| Power Supply | One 9V alkaline or NiCd battery |
| Hold Function | 7-second data freeze |
| Dual Display | Simultaneous current and maximum temperature readout |
| Backlit LCD | Auto-activated in low-light conditions |
| Ergonomic Design | Soft-grip rubberized handle |
| Included Accessory | Protective carrying pouch |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3i Plus |
| Price | USD 13,500 (est.) |
| Instrument Type | Portable (not online) |
| Temperature Range | 400–2000 °C / 752–3632 °F and 700–3000 °C / 1292–5432 °F (dual-range configuration) |
| Distance-to-Spot Ratio (D | S): 250:1 |
| Operating Ambient Temperature | 0–50 °C |
| Laser Aiming | Dual-laser + optical viewfinder with integrated red-dot targeting |
| Drop Rating | 1 m (IEC 60068-2-32) |
| Battery Life | Up to 24 h continuous operation (rechargeable Li-ion) |
| Connectivity | USB 2.0 + Bluetooth 4.2 BLE |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (software-enabled audit trail) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MP150 |
| Instrument Type | Online |
| Scan Rate | Up to 150 lines/sec |
| Spatial Resolution | Up to 1024 measurement points per line |
| Optical Resolution | 200:1 |
| Communication Interface | Built-in Ethernet TCP/IP |
| Alignment Aid | Integrated visible aiming laser |
| Cooling Options | Air- or water-cooled housing |
| Analog Outputs | Three independently configurable 4–20 mA outputs |
| Digital Interface | Bidirectional RS-485/RS-232 (optional modules available) |
| Spectral Response | Configurable across 1.0–5.0 µm range (model-dependent) |
| Temperature Range Options | –20 °C to 3000 °C (dependent on spectral band and optics) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TV40 |
| Price | USD 13,500 (approx.) |
| Instrument Type | Fixed-Mount |
| Brand | G-WON |
|---|---|
| Origin | Beijing, China |
| Model | KBA3.7/600LH(A) |
| Type | Portable |
| IR Temp Range | −50°C to 1000°C |
| Display Resolution | 0.1°C (0.1°F) <1000°C |
| IR Accuracy | ±1% of reading |
| Response Time | 150 ms |
| Spectral Response | 6–14 µm |
| D | S Ratio: 50:1 |
| Emissivity Adjustment | 0.10–1.00 |
| K-Type Thermocouple Range | −50°C to 1370°C |
| K-Type Accuracy | ±0.5% |
| Ambient Temp Range | 0–50°C |
| Ambient Temp Accuracy | ±0.5°C |
| RH Range | 0–100% RH |
| RH Accuracy | ±3.5% RH (20–80% RH) |
| Wet-Bulb Temp | 0–50°C |
| Display | 2.2″ color LCD, 1024×768 px |
| Storage | microSD up to 128 GB (8 GB included) |
| Power | 3.7 V / 1000 mAh LiMnO₂ rechargeable battery |
| Operating Current | ≤150 mA |
| Explosion Protection | Exib I Mb |
| IP Rating | IP54 |
| Dimensions | 243 × 140 × 40 mm |
| Weight | 450 g |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KBA3.7/1450LH |
| Price Range | USD 1–9,999 |
| Instrument Type | Portable |
| IR Temp Range | −50°C to 1500°C |
| Display Resolution | 0.1°C (≤1000°C), 1°C (>1000°C) |
| IR Accuracy | ±1.5% of reading |
| Response Time | 150 ms |
| Spectral Response | 6–14 µm |
| Display | 2.2″ color LCD, 1024×768 px |
| Distance-to-Spot Ratio | 50:1 |
| Emissivity Adjustment | 0.10–1.00 |
| K-Type Thermocouple Range | −50°C to 1370°C |
| K-Type Accuracy | ±0.5% |
| Ambient Temp Range | 0–50°C |
| Ambient Temp Accuracy | ±0.5°C |
| RH Range | 0–100% RH |
| RH Accuracy | ±3.5% RH (20–80% RH) |
| Wet-Bulb Temp Range | 0–50°C |
| Storage | microSD up to 128 GB (8 GB preinstalled) |
| Power | 1× 18500 LiMnO₂ rechargeable battery, 3.7 V, 1300 mAh, ≤150 mA operating current |
| Explosion Protection | Exib I Mb |
| IP Rating | IP54 |
| Dimensions | 243 × 140 × 40 mm |
| Weight | 450 g |
| Certifications | CNEX explosion-proof certificate, MA safety mark for coal mine use, third-party type test report |
| Brand | KELLER HCW |
|---|---|
| Origin | Germany |
| Model | CellaCast |
| Type | Online Infrared Thermometer |
| Temperature Range | 650–1700 °C |
| Measurement Principle | Two-Color (Ratio) Infrared Radiometry |
| Optical Field of View | Rectangular |
| Special Features | Clean Surface Detection (CSD), Automatic Temperature Detection (ATD), Analog & Serial Data Output, Integrated Alarm Interface, IP65 Housing (with optional air purge & water cooling) |
| Brand | KELLER HCW |
|---|---|
| Origin | Germany |
| Type | Portable Optical Pyrometer |
| Model | PV11 |
| Temperature Range | 700–3500 °C |
| Minimum Spot Size | 0.1 mm |
| Distance-to-Spot Ratio | up to 5000:1 (e.g., Ø1 mm target at 5 m) |
| Measurement Principle | Visual Intensity Comparison (Two-Color Reference Filament Method) |
| Emissivity Sensitivity | Low |
| Display | Integrated Digital Readout |
| Brand | KELLER |
|---|---|
| Origin | Germany |
| Model | HCW Series |
| Measurement Principle | Two-Color (Ratio) and Single-Wavelength Pyrometry |
| Temperature Range | –30 °C to 3500 °C (model-dependent, segmented calibration) |
| Optical Resolution (Distance-to-Spot Ratio) | Up to 300:1 |
| Spectral Response | 0.8–1.1 µm (short-wave), 1.6 µm, 2.2 µm, or 8–14 µm (depending on model) |
| Output Signals | 4–20 mA, 0–10 V, thermocouple emulation, RS232/RS422/RS485 |
| Environmental Rating | IP65 (standard), optional IP67/IP69K housings |
| Housing Material | Anodized aluminum or AISI 316 stainless steel |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU, IEC 61326-1 (industrial environments) |
| Brand | KELLER MSR |
|---|---|
| Origin | Germany |
| Type | Online Infrared Pyrometer |
| Model | PA Series |
| Optical Configurations | 4 Interchangeable Lenses |
| Target Spot Size | Down to 0.3 mm |
| Distance-to-Spot Ratio | Adjustable via Lens Selection |
| Analog Outputs | 2 (configurable as input/output) |
| Input/Output Flexibility | One analog channel可 configured as process input (e.g., furnace reference compensation) |
| Emissivity Compensation | Adjustable + Custom Correction Curve |
| Environmental Compensation | Transmission loss correction for protective windows, ambient radiation compensation |
| Targeting Options | Eyepiece viewfinder, Class 2 laser pointer, external video camera interface |
| Interface | USB, RS-485 (multi-drop network capable) |
| Display & Control | Integrated LED display + membrane keypad |
| Signal Processing | Adjustable smoothing, linearization, hold functions |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-108 |
| Instrument Type | Fixed-Mount Thermal Screening Gateway |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Thermal Resolution | ±0.3 °C |
| Measurement Range | 20 °C to 50 °C |
| Detection Distance | 1.5 m to 5 m |
| Throughput Capacity | 150–200 persons/min |
| Blackbody Emissivity | 0.96 ± 0.02 |
| NETD | ≤60 mK (F/1, 300 K, 50 Hz) |
| IR Sensor | Uncooled Microbolometer Array (160 × 120 pixels, 17 µm pitch, 8–14 µm spectral band) |
| Visible Camera | 2 MP CMOS, 6 mm lens, 0.01 Lux (color), SNR > 56 dB |
| Onboard Processing | Broadcom BCM2711 (64-bit quad-core @ 1.5 GHz), VideoCore VI GPU, dual-band Wi-Fi 802.11ac + Gigabit Ethernet |
| Power Input | 5 V/3 A via USB-C |
| Operating Temperature | 0 °C to 40 °C |
| Enclosure | Flame-retardant, waterproof PVC composite (IP54-rated indoor/outdoor use with optional rain canopy) |
| Passage Dimensions | 1900 (H) × 700 (W) × 580 (D) mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MS+ |
| Price | Upon Request |
| Temperature Range | -32 to 530 °C |
| Optical Resolution | 20:1 |
| Spot Size at 20 | 1: ≥13 mm |
| Emissivity Adjustment | 0.100–1.000 (0.001 step) |
| Response Time | 300 ms |
| Accuracy | ±1% or ±1 °C (0–530 °C) |
| Display Features | Max/Min Hold, Backlit LCD, High/Low Temperature Alarm |
| Safety Certification | Ex ia II C T4 (Intrinsically Safe) |
| Power Supply | 9 V Alkaline Battery |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | RS-HW-N01 |
| Instrument Type | Fixed-mount |
| Power Supply | 10–30 V DC |
| Power Consumption | 0.4 W |
| Sensor Type | Dual-element pyroelectric infrared (PIR) sensor |
| Alarm Duration Options | 5 s / 10 s / 30 s (configurable) |
| Delay-on-Alarm | Software-configurable |
| Mounting Method | Ceiling-mounted |
| Installation Height | 2.5–6 m |
| Detection Range | Ø6 m (at 3.6 m mounting height) |
| Detection Pattern | Omnidirectional 360° horizontal coverage |
| Output Interface | RS-485 |
| Communication Protocol | Modbus-RTU |
| Operating Temperature | −10 °C to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| RFI Immunity | 20–1000 MHz |
| Microcontroller | 8-bit low-power CMOS |
| Auto Temperature Compensation | Yes |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMTI 2 |
| Pricing | Available Upon Request |
| Field of View | 20° × 15° |
| Detector Resolution | 160 × 120 uncooled microbolometer |
| Spectral Range | 8–14 µm |
| Thermal Sensitivity (NETD) | ≤0.15 °C at 25 °C |
| Temperature Range | −10 °C to +250 °C |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Minimum Focus Distance | 30 cm |
| Focus | Manual |
| Laser Targeting | Integrated Class II laser pointer for center-point indication |
| Display | 3.5″ LCD with LED backlight, 4 color palettes (Iron Red, Rainbow, Grayscale, High-Contrast) |
| Storage | Removable SD card (up to 1 GB), supports ≥1000 thermal images |
| Battery | Rechargeable Li-ion, 4 h continuous operation |
| Power Supply | 12 V AC adapter included |
| Interface | USB Type-B |
| Dimensions | 230 mm × 120 mm × 110 mm |
| Weight | 0.75 kg (with battery) |
| Housing | Shock-resistant engineering plastic |
| Emissivity Adjustment | 0.20–1.00 in 0.01 increments |
| Measurement Tools | Dual movable crosshairs, ΔT (delta-T) calculation |
| Mounting | Handheld or tripod-compatible (1/4″–20 UNC thread) |
| Operating Ambient | −15 °C to +45 °C, 10–90% RH non-condensing |
| Storage Ambient | −20 °C to +70 °C |
| Included Accessories | TMTI 2 imager, rechargeable battery, 12 V AC charger, 128 MB SD card, USB card reader + cable, lens dust cap, power connector, software CD (user manual + PC reporting suite), carrying strap, protective carry case |
| Brand | SOLY |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | 692 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Online Monitoring System |
| Infrared Resolution | 384 × 288 |
| NETD | <0.04 °C @ 30 °C |
| FOV | 28° × 21° |
| Detector Type | Uncooled Polysilicon FPA, 17 µm pixel pitch, 8–14 µm spectral response |
| Frame Rate | 50 Hz |
| Temperature Range | 20–60 °C |
| Measurement Accuracy | ≤ ±0.3 °C (with optional high-precision blackbody calibrator, ambient 15–35 °C) |
| Repeatability | ≤ ±0.5 °C |
| Thermal Image Modes | Grayscale / Iron Red / Rainbow |
| FFC Correction | Auto & Manual |
| Output Format | Standard JPEG with embedded radiometric temperature data |
| Interface | USB 2.0 |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| IP Rating | IP54 |
| Power | DC 12 V (220 V AC adapter included) |
| Battery Life | >10 h (standby + continuous operation) |
| Weight | ~560 g |
| Dimensions | 97 × 145 × 93.5 mm |
| Mounting | Standard UNC 1/4"-20 tripod thread |
| Warranty | 1 year |
| Brand | TES |
|---|---|
| Origin | Taiwan |
| Model | TES-1327 |
| Measurement Range | -35 °C to +500 °C (-31 °F to 932 °F) |
| Resolution | 0.1 °C / 0.2 °F |
| Accuracy | ±2% of reading or ±2 °C (whichever is greater) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 12:1 |
| Emissivity Adjustment | 0.17–1.00 |
| Laser Targeting | Class II, <1 mW |
| Memory Capacity | 50 data points |
| Display | Backlit LCD |
| Auto Power-Off | ~15 seconds |
| Battery | 9V alkaline (006P) |
| Operating Environment | 0–50 °C, ≤80% RH |
| Storage | -10–60 °C, ≤70% RH |
| Dimensions | 172 × 118 × 46 mm |
| Weight | 220 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 810 |
| Type | Portable Infrared Thermometer |
| Infrared Temperature Range | -30 to +300 °C |
| Air Temperature Range (NTC) | -10 to +50 °C |
| IR Accuracy | ±2.0 °C (-30 to +100 °C), ±2 % of reading (remaining range) |
| NTC Accuracy | ±0.5 °C |
| Optical Resolution | 6:1 |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 steps) |
| Display | Backlit LCD with ΔT calculation |
| Laser Targeting | Single-point |
| IP Rating | IP40 |
| Weight | 90 g (incl. batteries and protective sleeve) |
| Dimensions | 119 × 46 × 25 mm (with sleeve) |
| Operating Temperature | -10 to +50 °C |
| Battery | 2 × AAA, ~50 h life (backlight off) |
| Response Time | 0.5 s (both channels) |
| Resolution | 0.1 °C (both IR and NTC) |
| Data Functions | Max/Min/Hold |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 826-T2 |
| Type | Portable Infrared Thermometer |
| Optical Resolution | 6:1 |
| Temperature Range | -50 to +300 °C |
| Accuracy | ±1.5 °C (-20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| Measurement Speed | 0.5 s per reading |
| Resolution | 0.1 °C |
| Display | Single-line LCD |
| Weight | 80 g |
| Dimensions | 148 × 34.4 × 19 mm |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| IP Rating | IP67 (with protective sleeve) |
| Compliance | EN 13485 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 826-T4 |
| Instrument Type | Portable |
| Optical Resolution | 6:1 |
| Laser Targeting | Single-point |
| IR Temperature Range | −50 to +300 °C |
| IR Accuracy | ±1.5 °C (−20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| NTC Probe Range | −50 to +230 °C |
| NTC Accuracy | ±0.5 °C (−20 to +99.9 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Measurement Speed | 0.5 s |
| NTC Measurement Speed | 1.25 s |
| Resolution | 0.1 °C (both modes) |
| Display | Single-line LCD |
| IP Rating | IP67 (with protective sleeve) |
| Weight | 80 g |
| Dimensions | 148 × 34.4 × 19 mm |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| Compliance | EN 13485, HACCP-ready |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 826-T4 |
| Type | Portable Dual-Mode Thermometer |
| Infrared Temperature Range | −50 to +300 °C |
| NTC Probe Temperature Range | −50 to +230 °C |
| IR Accuracy | ±1.5 °C (−20 to +100 °C), ±2 °C or ±2 % of reading (remaining range) |
| NTC Accuracy | ±0.5 °C (−20 to +99.9 °C), ±1 °C or ±1 % of reading (remaining range) |
| IR Resolution | 0.1 °C |
| NTC Resolution | 0.1 °C |
| IR Measurement Time | 0.5 s |
| NTC Measurement Time | 1.25 s |
| Optical Resolution | 6:1 |
| Laser Targeting | Single-point |
| IP Rating | IP67 (with protective sleeve) |
| Dimensions | 148 × 34.4 × 19 mm |
| Weight | 80 g |
| Operating Temperature | −20 to +50 °C |
| Storage Temperature | −40 to +70 °C |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 20 h |
| Display | Monochrome LCD, single-line |
| Compliance | EN 13485, HACCP-aligned |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 830-S1 |
| Type | Portable Infrared Thermometer |
| Housing Material | Anodized Aluminum |
| Laser Targeting | Single-Point |
| Alarm Function | Adjustable Upper/Lower Limit with Audible Alert |
| Measurement Principle | Non-Contact Infrared Pyrometry (8–14 µm Spectral Range) |
| Emissivity Adjustment | Fixed at 0.95 (optimized for common industrial surfaces) |
| Distance-to-Spot Ratio | 12:1 |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | -20 to 70 °C |
| Relative Humidity Limit | ≤95 % RH (non-condensing) |
| Power Supply | 2 × AAA batteries |
| Battery Life | Approx. 10 hours continuous use |
| Display | Backlit LCD with hold function |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration options available |
| Brand | testo |
|---|---|
| Model | 830-T1 |
| Type | Portable Infrared Thermometer |
| Temperature Range | -30 to +400 °C |
| Accuracy | ±1.5 °C or ±1.5 % of reading (0.1 to +400 °C) |
| Optical Resolution | 10:1 |
| Response Time | 0.5 s |
| Resolution | 0.1 °C |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 steps) |
| Measurement Frequency | 2 Hz |
| Display | Backlit LCD with Max/Min/Hold functions |
| Alarm | Dual user-defined limit thresholds with audible and visual alert |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Housing Material | ABS |
| Power Supply | 9 V alkaline battery |
| Battery Life | Approx. 15 hours |
| Brand | testo |
|---|---|
| Model | 830-T1 |
| Type | Portable Infrared Thermometer |
| Measuring Range | -30 to +400 °C |
| Accuracy | ±2 °C or ±2 % of reading (-30 to 0 °C), ±1.5 °C or ±1.5 % of reading (0.1 to +400 °C) |
| Optical Resolution | 10:1 |
| Response Time | 0.5 s |
| Temperature Resolution | 0.1 °C |
| Measurement Frequency | 2 Hz |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 steps) |
| Display | Backlit LCD |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Weight | 200 g |
| Dimensions | 190 × 75 × 38 mm |
| Power Supply | 9 V alkaline battery |
| Battery Life | Up to 15 hours |
| Housing Material | ABS |
| Brand | testo |
|---|---|
| Model | 830-T1 |
| Type | Single-point laser infrared thermometer |
| Distance-to-Spot Ratio | 10:1 |
| Temperature Range | -30 to +400 °C |
| Resolution | 0.5 °C |
| Accuracy | ±1.5 °C or ±1.5% of reading (for +0.1 to +400 °C), ±2 °C (for -30 to 0 °C) |
| Emissivity Adjustment | 0.2–1.0 (adjustable) |
| Dimensions | 190 × 75 × 38 mm |
| Weight | 200 g |
| Power Supply | 9 V alkaline battery (IEC 6LR61) |