Small Animal In Vivo Imaging System
Filter
Showing 1–30 of 95 results
| Brand | AoLong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Lab-Specific In Vivo Micro-CT Imaging System |
| Instrument Type | Tomographic Imaging |
| Tube Voltage | 20–90 kV |
| Focal Spot Size | 5 µm |
| Spatial Resolution | 3 µm |
| Density Resolution | 0.3–0.5% |
| Scan Geometry | Cone-Beam |
| Detector | Digital Flat-Panel Detector |
| Scan Time | 30 s – 2 min |
| Image Reconstruction Speed | 1024×1024, 720 projections |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Producer |
| Origin Category | Domestic |
| Model | InVivo PET-CT |
| Quotation | Upon Request |
| PET Axial Field of View (FOV) | 200 mm |
| PET Spatial Resolution | <1.5 mm (NEMA NU-4) |
| CT Spatial Resolution | ≤8 µm (isotropic voxel) |
| CT Spectral Capability | Photon-counting detector with material decomposition and K-edge imaging |
| Integrated Physiological Monitoring | Temperature-controlled animal bed, respiratory gating, ECG synchronization, integrated isoflurane anesthesia port |
| Software Workflow Modes | Static, dynamic, kinetic modeling, multi-bed stitching, 3D-PSF iterative reconstruction |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Small Animal Spectral Micro-CT |
| Field of View | Ø65 mm × L200 mm |
| X-ray Source | 90 kV sealed-tube, maintenance-free |
| Detector | Photon-counting energy-resolving detector |
| Minimum Pixel Resolution | 8 µm |
| Energy Bins | 2–8 selectable |
| Image Matrix | 512×512 to 1547×1547 |
| Radiation Leakage | <0.5 µSv/h at any external point |
| Dimensions (H×W×D) | 1622×1192×1458 mm |
| Power Supply | 100–240 VAC, 50–60 Hz, <300 W (excl. workstation) |
| Workstation | Intel Xeon 8-core CPU, 64 GB RAM, 256 GB SSD + 1 TB SSD + 4 TB HDD, 29″ display |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VISION90 |
| Imaging Modality | Transmission X-ray (Microfocus Radiography) |
| Field of View | 15 × 10 cm |
| Effective In Vivo Resolution | 3 µm |
| Tube Voltage | 90 kV |
| Focal Spot Size | 5 µm |
| Detector Pixel Pitch | 49 µm |
| A/D Conversion | 16-bit |
| Geometric Magnification | Up to 10× (customizable) |
| Maximum Sample Area | 15 × 10 cm (optional extended FOV available) |
| Compliance | Meets GBZ 138–2017 (Chinese National Standard for Leakage Radiation from X-ray Equipment) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VISION90A |
| Imaging Modality | X-ray Radiography (Primary), Optional Fluorescence & DXA Modules |
| Max. Tube Voltage | 90 kV |
| Energy Resolution | 100 kV (System Rated Max) |
| Spatial Resolution | 3 µm |
| Field of View | 150 × 100 mm |
| Sample Capacity | Up to 5 specimens simultaneously |
| Focal Spot Size | 5 µm |
| Detector Pixel Pitch | 49 µm |
| A/D Conversion | 16-bit |
| Geometric Magnification | Up to 10× (customizable) |
| Max. Detectable Area | 150 × 100 mm (standard), expandable on request |
| Brand | Artemis |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MARS |
| Instrument Category | Optical In Vivo Imaging System |
| Camera | Teledyne Princeton Instruments NIRvana Series |
| Optical Configurations | FAST (Wide-Field Acquisition) & Pathfinder (High-Resolution Targeted Imaging) |
| Modularity | Fully Modular Platform for Multimodal Integration |
| Sample Capacity | Single-animal positioning stage (mouse/rat compatible) |
| Dye Compatibility | Water-soluble D-A-D small-molecule NIR-II fluorophores (e.g., QY ≈ 1.2% at ~1000–1700 nm) |
| Brand | Artemis |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Artemis Medical Technology Co., Ltd. |
| Model | MARS Series |
| Instrument Type | Optical In Vivo Imaging System |
| Spectral Range | 400–1700 nm |
| Penetration Depth | >15 mm |
| Spatial Resolution | <3 µm |
| Fluorescence Lifetime Resolution | <5 µs |
| Frame Rate | >1000 fps |
| Multimodal Options | X-ray, CT, FLIM, NIR-I, Hyperspectral In Situ Imaging, Photothermal Therapy Module |
| Sample Capacity | Single-animal (mouse/rat) positioning stage |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Artemis |
|---|---|
| Model | MARS |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Imaging Modalities | Fluorescence (400–900 nm), X-ray, Computed Tomography (CT) |
| Category | Optical & Multimodal Preclinical Imaging System |
| Regulatory Classification | Class II Medical Device (China NMPA), CE-marked for research use only (RUO) |
| Brand | Artemis |
|---|---|
| Model | MARS-Full Spectrum |
| Imaging Modalities | Multispectral Fluorescence (400–1700 nm), X-ray, CT |
| Spectral Range | 400–900 nm (Visible–NIR-I), 900–1700 nm (NIR-II/SWIR) |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Optical In Vivo Imaging System |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | FIRM-TPM (Field-Expanded & High-Resolution Configurations) |
| Probe Weight | 2.2 g (HR) / 2.8 g (FE) |
| Probe Dimensions | 9.5×15.5×17 mm³ (HR) / 10×16×21 mm³ (FE) |
| Resolution | < 850 nm (HR) / < 1.3 µm (FE) |
| Field of View | > 180 × 180 µm² (HR) / > 400 × 400 µm² (FE) |
| Imaging Speed | 9 Hz @ 512×522, 18 Hz @ 256×256 |
| Axial Scan Range | 0–30 µm (HR) / 0–100 µm (FE) |
| Inter-plane Switching Speed | 4 Hz |
| Excitation Wavelength | 920 nm / 1030 nm (fs-pulsed) |
| Avg. Power | > 400 mW |
| Pulse Width | < 200 fs |
| Emission Collection Range | 300–720 nm |
| Bandpass Filters | 520/50 nm (Green), 605/50 nm (Red) |
| Working Distance | > 390 µm (HR) / ~1 mm (FE) |
| Data Acquisition | ≥ 120 MS/s, ≥ 16-bit resolution, ≥ 110 MHz bandwidth |
| Operating System | Windows 10 |
| Host PC | 32 GB RAM, 256 GB SSD + 2 TB HDD, 2 GB DDR5 professional GPU |
| Software | GINKGO-MTPM |
| System Footprint | 955 × 1380 × 825 mm³ (imaging unit) |
| Ambient Requirements | 24 ± 2 °C, RH < 60 % |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | LB983 |
| Imaging Modality | Bioluminescence & Fluorescence Optical Imaging |
| Camera Type | Cooled Slow-Scan CCD |
| Cooling Method | Peltier (−90 °C typical operating temperature) |
| Spectral Range | 400–900 nm |
| Pixel Resolution | Up to 3.2 MP (NC320 front-illuminated) / 1.0 MP (NC100 back-illuminated) |
| Field of View Adjustment | Motorized vertical camera positioning (35–725 mm travel) |
| Maximum Sample Height | 260 mm |
| Dark Box Light Tightness | < 0.001 lux internal ambient light leakage |
| Calibration | Integrated optical flat-field and intensity reference standard for quantitative cross-experiment comparability |
| PET Integration | MACU interface module with dedicated software synchronization for small-animal PET co-registration |
| Software Platform | IndiGO v5.x with FDA 21 CFR Part 11-compliant audit trail, GLP/GMP-ready reporting modules |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | LB985 |
| Imaging Modality | Optical Bioluminescence & Fluorescence Imaging |
| Detector | 12-Megapixel Cooled EMCCD (–20 °C operating temperature) |
| Quantum Efficiency Peak | 500–750 nm |
| Imaging Modes | Bioluminescence/Chemiluminescence (LULu), Ultra-Low-Noise CCD (IKLu), Dual-Mode Bioluminescence + Fluorescence (LUFlu) |
| Illumination | LED-based Simulated Sunlight (Top Illumination), Side Illumination Module |
| Sample Stage | Motorized X-Y Translation + 360° Rotational Platform |
| Environmental Control | Integrated Temperature & Humidity Regulation |
| Software | indiGO™ v6.x with Hardware Synchronization, Audit Trail, and GLP-Compliant Data Archiving |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP6602 |
| Type | Compact Planar Gamma Camera for Small-Animal and Human Thyroid/Parathyroid Imaging |
| Origin | Hebei, China |
| Regulatory Approvals | NMPA (ex-SFDA) Certified, FDA 510(k) Cleared |
| Field of View (FOV) | ≥150 mm |
| Energy Range | 70–364 keV (optimized for ⁹⁹ᵐTc, ¹²³I, ¹³¹I) |
| Intrinsic Spatial Resolution | ≤3.8 mm FWHM |
| Maximum Count Rate | ≥150 kcps |
| Intrinsic Uniformity | ≤±3.0% integral, ≤±0.5% differential |
| Intrinsic Spatial Linearity Error | ≤0.4 mm |
| Dimensions (L×W×H) | 1192 × 804 × 1268 mm (low position) / 1468 mm (high position) |
| Weight | 147 kg |
| PACS Integration | Yes |
| Software Interface | Full Chinese GUI with quantitative analysis modules for thyroid area/weight, renal time-activity curves, gated blood pool, and static bone imaging |
| Brand | BioLight |
|---|---|
| Model | AniView100 |
| Imaging Modality | Optical (Bioluminescence, Fluorescence, Cerenkov, Upconversion Fluorescence), Optional X-ray |
| CCD Sensor | Deep-cooled scientific-grade CCD, -100°C operating temperature |
| Filter Capacity | Up to 20 excitation LEDs + 10 emission filters |
| Software | Quantitative analysis with radiance calibration (p/s/cm²/sr), automated focus & protocol execution |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | BioLight |
|---|---|
| Origin | Guangdong, China |
| Model | PlantView100 |
| Imaging Modality | Optical Bioluminescence & Fluorescence Imaging |
| Maximum Field of View | 280 mm × 280 mm |
| Camera | Dual-cooled scientific-grade CCD (−100 °C), QE > 95% |
| Excitation Sources | Up to 20 narrowband high-power LEDs |
| Emission Filters | Up to 10 precision OD6 bandpass filters |
| Optional Modules | Side-view imaging module, X-ray imaging module, Chlorophyll fluorescence module, Light simulation module (4-channel LED: blue/white/red/NIR), Cell labeling quantification module (tube & 96-well formats) |
| Software | GLP-compliant, audit-trail enabled, auto-calibrated photon flux quantification (p/s/cm²/sr), raw + processed data segregation, export to CSV/Excel with embedded metadata |
| Brand | Biopticon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TumorImager 2 |
| Instrument Type | Optical 3D Surface Imaging System |
| Scan Resolution | 480 × 640 pixels |
| Scan Speed | <1 s per acquisition |
| Field of View | 30 mm × 20 mm |
| Sample Capacity | 1 animal per scan |
| Z-Axis Resolution | 50 µm |
| Interface | USB 3.0 |
| Output Formats | JPG (2D), OBJ & PLY (3D surface mesh) |
| Operating Modes | Handheld or Stand-Mounted |
| Tumor Length Limit | ≤30 mm |
| Tumor Height Limit | ≤20 mm |
| Automatic Segmentation Time | ~3 s |
| Data Storage | Local SQL database with user authentication and audit trail |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2PPlus |
| Price Range | USD $380,000–$640,000 (est.) |
| Instrument Type | Optical In Vivo Imaging System |
| Scanning Resolution | 2048 × 2048 pixels |
| Maximum Frame Rate | 1300 fps |
| Field of View | 1.9 mm × 1.9 mm (with 16× objective) |
| Sample Capacity | 1 specimen per acquisition session |
| Excitation Wavelength Range | 400–1700 nm |
| Multiphoton Capability | Two-photon and three-photon imaging supported |
| Scan Modes | Galvo-based raster, spiral, and resonant scanning |
| Objective Compatibility | Motorized and manual multi-axis rotating objectives (single- and multi-axis) |
| Optional Modules | Full-field LED illumination, 1P/2P uncaging, spatial light modulator (SLM)-based patterned excitation |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Albira Si |
| Price Range | USD 1,100,000 – 1,380,000 (based on FOB US pricing and typical import duty/tax structure) |
| Instrument Type | Trimodal Molecular Imaging System |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioSpec |
| Instrument Type | Nuclear Magnetic Resonance (NMR) Imaging System |
| Field Strength Options | 4.7 T, 7.0 T, 9.4 T, 11.7 T, and 15.2 T configurations available |
| Cryogenic Probe Technology | MRI CryoProbe® |
| Magnet Type | Ultra-Shielded Resistive (USR) or Superconducting Magnets |
| Regulatory Compliance | CE-marked, ISO 13485-certified manufacturing processes, compliant with IEC 62304 for medical device software lifecycle management |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Maxwell |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Energy Resolution | 1000 (arbitrary units, typical for spectral stability metric) |
| Spatial Resolution | 0.05 mm (isotropic, in vivo) |
| Scan Time per Sequence | <1 min (typical for rapid anatomical protocols) |
| Simultaneous Sample Capacity | 2 animals |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | BioSpec® 3T |
| Field Strength | 3 Tesla |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) System |
| Bore Diameter | 180 mm |
| RF Coil Options | >30 dedicated coils for mouse/rat head, brain, heart, body, multinuclear, and functional applications |
| Gradient Strength | Up to 900 mT/m |
| Gradient Linearity | ±3.5% within 50 mm DSV |
| Shim System | 6 high-order shim coils + high-power shim power supplies (up to 3750 Hz/cm² in XZ/YZ) |
| Magnetic Field Homogeneity | ±0.1 ppm within 50 mm DSV |
| Magnet Hold Time | >4 hours after power loss or coolant interruption |
| Software Platform | ParaVision® with >1000 optimized pulse sequences including IntraGate™, UTE, ZTE, and non-ECG-triggered cardiac imaging |
| Multi-Modal Compatibility | PET, optical imaging, CT |
| Regulatory Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICON |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Field Strength | 1 Tesla |
| Target Subjects | Rodents (Mice & Rats) |
| Magnet Type | Cryogen-Free Permanent Magnet (Aspect Magnet Technologies) |
| Core Platform | AVANCE III Spectrometer Architecture |
| Software Suite | ParaVision® 360 |
| Application Domain | Preclinical Molecular Imaging, Longitudinal In Vivo Studies, Educational MRI Training |
| Operating Cost Profile | Low (No Liquid Helium or Cryogen Refills Required) |
| Footprint | Benchtop (≤ 1.2 m × 0.8 m × 1.4 m) |
| Regulatory Compliance | CE Marked, ISO 13485–Compliant Design, FDA 510(k)-Cleared for Preclinical Use (K220927) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Investigator |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical Imaging System |
| Scanning Resolution | ~700 nm |
| Maximum Frame Rate | 1300 fps |
| Field of View | 0.85 × 0.85 mm (with 16× objective) |
| Sample Capacity | 1 animal per session |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MPI |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Nuclear Imaging |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Opterra II |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical Imaging System |
| Maximum Scan Resolution | 2048 × 2048 pixels |
| Frame Rate | up to 100 fps |
| Field of View | Objectives-dependent (e.g., 0.25 mm² at 60×, 1.0 mm² at 10×) |
| Sample Capacity | Single specimen stage with motorized XYZ + focus control |
| Detection Technology | EMCCD and sCMOS dual-path detection |
| Scanning Method | Parallel field-scanning via programmable slit/multi-spot illumination |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PET/MR 3T |
| Imaging Modality | Integrated Positron Emission Tomography / Magnetic Resonance Imaging |
| Energy Resolution | 17% FWHM at 511 keV |
| Spatial Resolution (PET) | <0.7 mm (NEMA NU-4) |
| Spatial Resolution (MRI) | ≤1.2 mm isotropic (with CryoProbe™) |
| Scan Speed | Up to 10 min per dynamic PET frame (variable by protocol) |
| Field of View (FOV) | 80 mm (PET transaxial), 148 mm (MRI transaxial), 285 mm (whole-body MRI longitudinal) |
| Animal Capacity | 1 subject per scan (mouse or rat) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 1178 |
| Instrument Type | Tomographic Imaging |
| X-ray Source | Sealed Metal-Ceramic Tube (20–65 kV, 40 W) |
| Detector | Digital X-ray Camera (1280 × 1024 pixels, 12-bit) |
| Scan Volume | Ø82 mm × 82 mm (single scan), up to 200 mm full-length |
| Voxel Size (isotropic) | 80 µm (1024³) or 160 µm (512³) |
| Minimum Scan Time | <45 s (160 µm) |
| Full-body mouse scan | 3 min 20 s (80 µm) |
| Reconstruction Time | 45 s (160 µm) |
| Animal Handling | Carbon-fiber mouse/rat bed on interchangeable mounting platform |
| Physiological Monitoring | Real-time respiration & ECG gating, motion detection |
| Radiation Safety | Surface dose rate <1 µSv/h during operation |
| Software Suite | NRecon, DataViewer, CTAn, CTVol, MorphoGraphX |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 1276 |
| Imaging Modality | X-ray micro-computed tomography (micro-CT) |
| Spatial Resolution (nominal) | ≤2.8 µm |
| Scan Modes | Step-and-shoot, continuous gantry rotation with slip-ring interface |
| Scan Time per Reconstruction | as low as 3.9 s |
| Reconstructed Slice Count per Scan | >1600 slices |
| Max Image Matrix Size | 8000 × 8000 pixels |
| X-ray Source Voltage Range | 20–100 kV adjustable |
| Automatic Filter Changer | 6-position |
| Dose Reduction Technology | Beam-shaping collimator (patented by Bruker microCT) |
| Physiological Monitoring Integration | Respiratory gating, ECG synchronization, temperature stabilization, motion detection |
| Animal Handling | Interchangeable mouse/rat beds with integrated anesthesia mask and sensor interface |
| Real-time Dose Monitoring | On-screen dosimetry derived from projection image analysis |
| Reconstruction Acceleration | GPU-accelerated algorithms + InstaRecon® layered reconstruction (≥10× faster than conventional FBP) |
| Software Compliance | GLP-compliant software suite with audit trail, user access control, and electronic signature support |
| Data Export & Remote Viewing | Direct export to iOS/Android devices via dedicated viewer app |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan1278 |
| Instrument Type | Tomographic Imaging System |
| Energy Resolution | 17% |
| Spatial Resolution | 50 µm |
| Scan Time | 7.2 s per full-body mouse scan |
| Field of View Diameter | 80 mm |
| Scan Length | 200 mm |
| Sample Capacity | 1 animal per scan |
| X-ray Source | Adjustable 20–65 kV microfocus tube with patented beam shaping optics |
| Detector | High-sensitivity CMOS flat-panel detector |
| Dose Level | <6 mGy for whole-body murine scan |
| Physiological Gating | Integrated respiratory, ECG, temperature, and motion monitoring |
| Data Output Formats | DICOM, TIFF, JPG, BMP, PNG, AVI |
| Software Compliance | GLP-compliant acquisition and reconstruction suite |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vutura352 |
| Instrument Type | Optical Imaging System |
| Lateral Resolution | 20 nm |
| Axial Resolution | 50 nm |
| Maximum Frame Rate | 300 fps |
| Field of View | 40 µm × 40 µm |
| Sample Capacity | Single Specimen |
| Application Domain | Live-cell & Small-animal In Vivo Imaging |
