Other Magnetic Measurement Systems
Filter
Showing 1–30 of 43 results
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NMI-VSM |
| Price | Upon Request |
| Sensitivity (RMS) | 5×10⁻⁷ emu |
| Oscillation Frequency Range | 1–100 Hz (calibrated) |
| Oscillation Amplitude Range | 0.1–5 mm |
| Maximum Sample Diameter | 6 mm |
| Temperature Range | 2 K to 1000 K |
| Magnetic Field Range | Up to 2.5 T (electromagnet), up to 14 T (with cryostat) |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | attoNVM |
| Temperature Range | 1.8–300 K |
| Magnetic Field Range | ±9 T (vector, 1–1–1 T) or ±1 T (vector, 1–1–1 T) |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AUT-CI-QBHM2 |
| Power Handling Capacity | Up to 20,000 W |
| Wavelength Range | 400–1150 nm |
| Interface | QBH Fiber Connector |
| Software | RayCi-Pro v5.x |
| Camera Core | CinCam CMOS Beam Profiler |
| Compliance | ISO 11146-1:2021, ISO 11146-2:2021, ANSI Z136.1 |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | CAM-01U |
| Measurement Principle | Self-Oscillating Cesium Vapor Optically Pumped Magnetometry |
| Operating Depth | 400 m |
| Magnetic Field Range | 20,000–100,000 nT |
| Sensitivity | ≥4 pT/√Hz |
| Sampling Rate | Up to 10 Hz |
| Absolute Accuracy | <2 nT |
| Heading Error (Auto-Hemisphere Switching) | <2 nT |
| Minimum Field Angle for Stable Operation | >10° from sensor axis relative to geomagnetic vector |
| Output Interface | RS-232 (600–9600 baud) |
| Power Supply | 24–32 VDC, <1 A |
| Operating Temperature | 0°C to +50°C |
| Storage Temperature | −45°C to +70°C |
| Towed Fish Dimensions | 1.48 m length, 18.9 kg (incl. housing, sensor, electronics, primary ballast) |
| Tether Cable | Kevlar-reinforced multilayer, 12 mm OD, 1.6 t tensile strength, standard 60 m length |
| Waterproof Rating | Dual O-ring sealed interface, IP68 equivalent |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | NV-Array-Sapphire-36 |
| Type | Solid-State Quantum Sensor Platform |
| Application Domain | Magnetometry, Quantum Optics, Nanoscale NMR, Single-Photon Source Integration |
| Compliance | Designed for GLP-aligned lab environments |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FGM3D |
| Pricing | Available Upon Request |
| Measurement Ranges | ±75 µT to ±1000 µT (configurable) |
| Bandwidth | Up to 6 kHz |
| Output Interface | RS232 (FGM3D UWD), Optional Analog/USB/Digital Variants |
| Housing Material | PEEK or POM |
| IP Rating | IP67 (waterproof) |
| Orthogonality Error | < 0.1° (with compensation coils) |
| Resolution | Down to 70 pT (at ±250 µT range) |
| Power Supply | ±15 V DC |
| Operating Temperature | –20 °C to +70 °C |
| Noise Floor | < 10 pT/√Hz (typ. at 1 Hz) |
| Brand | Auniontech |
|---|---|
| Model | Geoshark MG30M |
| Magnetometer Type | Optically Pumped (Rubidium Vapor) |
| Measurement Principle | Quantum Optical Pumping & Larmor Precession Detection |
| Operating Temperature Range | −20 °C to +40 °C |
| Magnetic Field Range | 20,000–100,000 nT |
| Sensitivity | 0.1–0.5 pT/√Hz |
| Measurement Rate | 1,000 Hz |
| Closed-Loop Bandwidth | 30 Hz |
| Sensor Tilt Tolerance | ±45° |
| Typical Bias Stability | <0.3 nT |
| UAV Platform | Geoscan 401 Industrial Quadcopter |
| Ground Track Accuracy | ≤0.6 m deviation from planned route |
| Typical Survey Speed | 10 m/s (36 km/h) |
| Operational Altitude | 25–500 m AGL |
| Max Flight Duration (single battery) | ~60 min |
| Daily Coverage (12–16 flights) | 160–220 km |
| Data Output Format | GeoTIFF, ASCII Grid, CSV with full georeferencing |
| Software Suite | QMCentre (acquisition & real-time monitoring), Geoscan Mission Planner, Agisoft Metashape PRO (photogrammetric integration) |
| Brand | Auniontech |
|---|---|
| Model | Mageye |
| Type | Handheld Magneto-Optic Field Imaging System |
| Measurement Principle | Faraday Effect-Based Pulsed Magnetic Field Visualization |
| Magnetic Field Range | 0.01–130 kA/m (0.1–1600 Oe) |
| Sensor Active Area | Up to 8 × 8 mm |
| Interface | USB 2.0 |
| Optical Resolution | Micrometer-Level (µm) |
| Power Supply | Bus-Powered via USB |
| Compliance | CE, RoHS |
| Application Domain | Non-Destructive Magnetic Inspection, GLP-Compatible Qualitative Field Mapping |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MMS-1A-RS |
| Measurement Principle | Pulsed and DC/AC Magnetic Field Mapping via Triaxial Hall Probe |
| Scanning Range (X×Y×Z) | Standard 135 mm × 135 mm × 135 mm |
| Spatial Resolution | ≤1 µm (linear), 0.022° (rotational) |
| Field Measurement Ranges | 50 mT / 0.2 T / 1 T or 0.1 T / 0.5 T / 2 T |
| Field Accuracy | Better than ±0.1% of reading |
| Frequency Bandwidth | DC–2.5 kHz (standard triaxial probe) |
| Probe Dimensions (Sensitive Volume) | By: 0.02 × 0.005 × 0.02 mm³ |
| Bx & Bz | 0.14 × 0.01 × 0.14 mm³ |
| Temperature Monitoring | Integrated real-time thermal sensing |
| Motion Control | 4-axis (X/Y/Z linear + θ rotation) with Renishaw TP20 tactile sensor for collision-safe tip positioning |
| Software Platform | Windows-based LabVIEW application with customizable visualization, GLP-compliant data logging, and on-site recalibration capability |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MO-100 Series |
| Pricing | Upon Request |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | PTM-1000 |
| Detection Principle | Pump–Probe Photothermal Deflection Based on Thermal Lens Effect |
| Pump Wavelength | Customizable (Typical 1064 nm / 532 nm / 355 nm) |
| Probe Wavelength | 633 nm (He–Ne Laser) |
| Chopping Frequency | 390 Hz ± 10 Hz |
| Surface Absorption Sensitivity (Transmissive, Fused Silica Substrate, 1 W Pump) | < 0.25 ppm |
| Bulk Absorption Sensitivity (Transmissive, Fused Silica, 1 W Pump) | < 5 ppm/cm |
| Surface Absorption Sensitivity (Reflective Configuration) | < 0.5 ppm |
| Noise-Equivalent Absorbed Power (Surface, Transmissive) | < 0.25 µW |
| Noise-Equivalent Absorbed Power (Bulk, Transmissive) | < 5 µW/cm |
| Noise-Equivalent Absorbed Power (Reflective) | < 0.5 µW |
| Probe Beam Spot Size (FWHM) | 225 µm ± 50 µm |
| Pump Beam Spot Size (FWHM) | 75 µm ± 20 µm |
| Lateral Spatial Resolution (FWHM) | < 60 µm |
| Axial (Depth) Resolution (FWHM) | < 1 mm |
| XYZ Translation Stage | 50 mm × 50 mm × 50 mm, Stepper Motor Driven |
| Probe Laser | Pacific Lasertec 05-LHP-121 or Equivalent |
| Probe Output Power | 2 mW (Class 3R) |
| Probe RMS Intensity Noise | ≤ 0.1% (30 Hz – 10 MHz) |
| Signal Processing | Dual Lock-in Amplifier Synchronized to Chopping Frequency |
| Compliance | Designed for GLP/GMP-adjacent R&D Environments |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SEN-3D-CAM-3D |
| Measurement Principle | Senis 3D Hall Sensor Array |
| Spatial Resolution | 100 µm |
| Pixel Count | 128 × 128 (16,384 pixels) |
| Sensitive Volume per Pixel | 27 µm × 9 µm × 4 µm |
| Image Acquisition Rate | 1 frame/s |
| Calibration Ranges | ±100 mT / ±500 mT |
| Absolute Accuracy | <1% of full scale |
| Repeatability | <0.2% of full scale |
| Temperature Calibration Range | 20–30 °C |
| Minimum Working Distance | 300 µm |
| Operating Temperature | 10–50 °C |
| Interface | USB 3.0 (RNDIS), 5 V powered |
| Digital Resolution | 12-bit |
| Non-orthogonality Error | <0.5° |
| Housing | Rugged lightweight aluminum enclosure |
| Weight | ~100 g |
| Optional Software | Senis 2D Vision Commander v1.3 (Windows 7+) |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model Designation | Magnetic Material Reference Standards |
| Price | Available Upon Request |
| FMR Linewidth (ΔH) | < 1.5 Oe (FWHM) |
| 4πMs | 1600 ± 80 G |
| Sphere Diameter | 0.25 mm |
| Cube Edge Length | 0.5 mm |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | spinEDU Quantum Education System |
| Pricing | Upon Request |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | THz-Imager Pro |
| Spectral Range | 0.05–0.7 THz |
| Frame Rate | Up to 5000 fps |
| Detector Type | Semiconductor Array |
| Pixel Options | 256 × 1, 1024 × 1, or 4096 × 1 linear array |
| Pixel Size | 1.5 × 1.5 mm |
| NEP | 1 nW/√Hz (detector), 14–100 nW/pixel (system, frame-rate dependent) |
| THz Source Options | Fixed-frequency (100/140 GHz), Tunable CW (70–310 GHz), High-Power (up to 300 mW) |
| Detector Response Time | 150 ps (ultrafast), 1 µs (standard) |
| Impedance | 50 Ω |
| Responsivity | 0.5–10 V/W |
| Optical Components Available | PTFE/TPX lenses (Ø1–30 cm, f = 50–300 mm), windows, prisms, polarizers, beam splitters, attenuators |
| Key | Brand: Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | CS-01 / CS-02 / HQ-04 |
| Operating Voltage | 18–30 VDC |
| Working Temperature | −55 °C to +150 °C |
| Storage Temperature | −55 °C to +70 °C |
| Max Working Pressure | ≤0.6 MPa |
| Sealing Performance | ≥0.3 MPa |
| Magnetic Pole Gap | 2.0 ± 0.1 mm (CS-01/CS-02), 1.7 ± 0.1 mm (HQ-04) |
| Magnetic Attraction Force | ≥50 g (CS-01/CS-02), ≥100 g (HQ-04) |
| Filtration Rating | 900 µm (CS-01), None (CS-02), 600 µm (HQ-04) |
| Ground Resistance | ≤20 mΩ |
| Insulation Resistance | ≥20 MΩ |
| Compatible Fluids | MIL-PRF-23699 (GJB 1263–1991 compliant) synthetic aircraft lubricants (e.g., 4106, 4050) |
| Humidity Limit | ≤90% RH |
| Max Operational Altitude | 20,000 m |
| TBO | 1000 engine operating hours |
| Service Life | 4000 engine operating hours |
| Installation Interface | φ18 flange (CS-01), M12×1.5 (CS-02), φ27 flange (HQ-04) |
| Dimensions | ≤φ41×72 mm (CS-01), ≤φ31×77 mm (CS-02), ≤φ54×82 mm (HQ-04) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | DryMag |
| Temperature Range | 1.5 K to 300 K (420 K optional) |
| Magnetic Field | Up to 12 T vertical, up to 7 T horizontal |
| Cooling Method | Closed-cycle cryocooler with static helium exchange gas |
| Sample Environment | Top-loading, gas-cooled sample space |
| Optical Access | Optional bottom or horizontal viewport |
| Rotation Options | Single-axis (vertical) or dual-axis (vertical + horizontal) sample rotation |
| Base Temperature | ≤1.5 K |
| Initial Cool-down Time | ~24 h |
| Temperature Stability | ±50 mK |
| Sample Exchange Time | 90 min |
| Cryocooler Maintenance Interval | 10,000 h (Gifford-McMahon) or 20,000 h (pulse tube) |
| Optional Add-ons | He-3 insert (300 mK), electrical feedthroughs, M81-SSM source-measure unit, M91 FastHall controller, MeasureLINK software suite |
| Brand | Geoscan |
|---|---|
| Origin | Imported (Non-Chinese) |
| Manufacturer Type | Authorized Distributor |
| Model | R3 / R4 |
| Price Range | USD 105,000 – 140,000 (FOB) |
| Magnetic Field Range | ±75,000 nT (expandable) |
| Resolution | <150 pT |
| Sampling Rate | 200 Hz (configurable) |
| Real-time Output Rate | 2 Hz |
| Operating Temperature | −20 °C to +50 °C |
| Weight (R3 w/battery) | 750 g |
| Weight (R4 w/battery) | 2.7 kg |
| Onboard Storage | 2 GB SD card |
| Integrated Sensors | Triaxial fluxgate magnetometers (2 channels for R3 |
| Data Processing Software | DataTool (included), optional advanced processing suite |
| Brand | HeatWave Labs |
|---|---|
| Origin | USA |
| Model | LaB6 |
| Operating Temperature | 950–1200 °C |
| Emission Current Density | ≥3–5 A/cm² (CW), >15 A/cm² (pulsed) |
| Cathode Material | Lanthanum Hexaboride (LaB6) |
| Insulation | Alumina (Al₂O₃) |
| Structural Body | Molybdenum (Mo) |
| Lifetime | >10,000 hours under optimal vacuum and thermal conditions |
| Electrical Isolation | Dual independent power leads fully isolated from housing |
| Gas-Free Operation | Yes |
| Optional Coatings | Os/Ru (M-type), Os/W, IR-emission-enhancing coatings |
| Scan Configurations Available | 311, 532, 411, 612, M (customizable per request) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 8600 |
| Magnet Type | Electromagnetic |
| Measurement Principle | Vibrating Sample Magnetometry (VSM) |
| Temperature Range | 10 K – 1273 K |
| Magnetic Field Range | Up to 3.62 T |
| Magnetic Moment Sensitivity | 5 × 10⁻⁸ emu |
| Field Sweep Rate | 10,000 Oe/s |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Microscopy |
| Price | Upon Request |
| Magnetic Field | 0–7 T (Vertical Bore) |
| Bore Diameter | 42 mm (Room-Temperature Bore) |
| Temperature Range | 3.5 K to 325 K (420 K Optional) |
| Vacuum Environment | UHV-Compatible |
| Optical Access | Multiple Collinear & Off-Axis Ports |
| Sample Diameter Capacity | Up to 16 mm |
| Motion Control | High-Precision Motorized X-Y-Z Translation Stage |
| Compatible Cryostat | ST-500 High-Stability Microscope Cryostat |
| Primary Measurement Modalities | Micro-Raman, Photoluminescence (PL), Magneto-Optical Kerr Effect (MOKE) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OptiMag |
| Pricing | Upon Request |
| Magnetic Field Range | 6–12 T (up to 16 T with optional configurations) |
| Temperature Range | 1.5–325 K |
| Sample Bore Diameter | 1.25–1.75 in |
| Helium Dewar Volume | 12 L |
| Hold Time (Static Cryogenic) | ~60 h |
| Field Homogeneity | ±0.5% to ±0.001% over 1 cm Ø sphere |
| Optical Access | Axial (bottom or top), along field direction |
| Cooling Environment | Continuous-flow cryogen or vacuum |
| Compatible Configurations | Vector magnet (2–3 independent coils), horizontal-field, Mössbauer-compatible vertical-drive with top-loaded source/absorber |
| Optional Add-ons | M81 Synchronous Source Transport Measurement System, M91 Fast Hall Probe System, He-3 Insert (<1.4 K), Lambda-point refrigerator (for 9–16 T systems) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Room Temperature Bore Superconducting Magnet |
| Magnetic Field Range | 6–14 T |
| Bore Temperature | Ambient (300 K) |
| Sample Environment Options | Ambient Atmosphere, Vacuum, Ultra-High Vacuum (UHV), Cryogenic Insert Compatible (1.5 K – 800 K) |
| Optical Access | Optional Viewports |
| Bore Diameter | Customizable |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SuperOptiMag |
| Price | Upon Request |
| Magnetic Field Strength | 5–7 T (up to 8 T with Lambda cryocooler) |
| Temperature Range | 1.5 K to 325 K |
| Sample Environment | Continuous-flow cryogen or high-vacuum |
| Optical Access | Bottom, side, and top windows (strain-relieved options available) |
| Field Orientation | Horizontal or vertical |
| Bore Diameter | 0.75 in to 1.25 in |
| Field Homogeneity | ±0.5% over standard sample volume |
| Static Hold Time | ~130 hours (SOM-2 with 1-inch bore, f/2–f/2.5) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | SuperVariMag |
| Pricing | Upon Request |
| Brand | MagArrow |
|---|---|
| Model | MagArrow |
| Type | Airborne Cesium Vapor Scalar Magnetometer |
| Operating Principle | Laser-Pumped Cesium Vapor (Non-Radioactive ¹³³Cs) |
| Measurement Range | 20,000–100,000 nT |
| Gradient Tolerance | 10,000 nT/m |
| Sampling Rate | 1000 Hz (GPS-synchronized 1 PPS) |
| Heading Error | ±5 nT @ 360° |
| Integrated Sensors | High-Accuracy MFAM Magnetometer, Dual-Frequency GNSS Receiver, Tactical-Grade IMU, Radar Altimeter |
| Data Logging | Onboard SD card with WiFi download capability |
| UAV Compatibility | Compatible with drones ≥3 kg payload capacity |
| Maximum Survey Speed | 10 m/s |
| Spatial Sampling Resolution | 1 cm at nominal speed |
| Power Supply | Integrated rechargeable Li-ion battery system |
| Environmental Rating | IP67-rated enclosure |
| Brand | Makeway |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | lgTIRF |
| Pricing | Upon Request |
| Measurement Principle | Light-guided TIRF (not SQUID) |
| Excitation Delivery | FC-PC fiber-coupled (2 m length) |
| Evanescent Field Depth | ~100 nm |
| Compatible Objectives | Dry, water-immersion, oil-immersion |
| Substrate Compatibility | Glass/silica coverslips, optically clear-bottom dishes |
| Excitation Wavelength Range | 190–1000 nm (UV-capable) |
| Configurable Modes | TIRF, SAFM (shallow-angle fluorescence), MSE (microspot excitation) |
| Calibration | Factory-calibrated, angle-stabilized geometry |
| Switching Speed | Instant mode switching between TIRF/SAFM/MSE/epifluorescence/transmission |
| Brand | Makeway |
|---|---|
| Model | MKW-4900 |
| Origin | Shanghai, China |
| Magnet Type | Electromagnet |
| Temperature Range | 300 °C |
| Measurement Principle | Thermally Stimulated Depolarization Current (TSDC) |
| Voltage Range | ±100 V to ±10 kV |
| Software Platform | aixPlorer / ResoCe Analyzer |
| Interface | GPIB, Ethernet, ODBC |
| Output Format | ASCII |
| Brand | Makeway |
|---|---|
| Model | MKW-4900 |
| Origin | Shanghai, China |
| Magnet Type | Electromagnet |
| Temperature Range | 300 °C (max) |
| Measurement Principle | Thermally Stimulated Depolarization Current (TSDC) |
| Voltage Range | ±100 V to ±10 kV |
| Software Platform | aixPlorer / Resoce Analyzer |
| Interface | GPIB, Ethernet, ODBC |
| Output Format | ASCII |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | HallinSight® 3D |
| Quotation | Upon Request |