| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | 33-627-02 |
| Measurement Range | 10–95% RH |
| Accuracy | ±5% RH |
| Resolution | 1% RH |
| IP Rating (when installed) | IPX4 |
| Compatible Systems | Airmar 110WX, 120WX, 150WX, 200WX, 220WX Weather Stations |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | AP-400 / AP-450 |
| Input Channels | 1 (Thermocouple) |
| Thermocouple Types Supported | AP-400 — E or K only |
| Measurement Range | E: −200 to +800 °C |
| K | −200 to +1370 °C |
| J | −200 to +1100 °C |
| T | −200 to +400 °C |
| R | 0 to +1760 °C |
| Resolution | 0.1 °C (within specified ranges), auto-switches to 1 °C outside |
| Accuracy | ±(0.05% of reading + 0.2 °C) for E/K/J/T at 0–100 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 ±10 °C |
| Temp. Coefficient | ±0.01% of range per °C outside 25 ±10 °C |
| Operating Environment | 0–40 °C, 0–80% RH (non-condensing) |
| Storage | −20 to +50 °C, 0–85% RH (non-condensing) |
| Sampling Rate | 2 Hz (no print), down to 1 sample/min (interval modes) |
| Battery Life | Up to 120 hours (1-min interval, no print) |
| Power | 4 × AA alkaline batteries (included) or optional AC adapter (AD-100/115/220-500-HR-R) |
| Display | LCD |
| Printer | Thermal line printer, 2.5 mm character height, 37 mm paper width, 1000 lines per roll |
| Memory Capacity | 100 data records |
| Data Output | Absolute timestamp (HH:MM:SS), sequential numbering, batch print |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Dimensions | ~68 × 201 × 42 mm (W×H×D, excl. protrusions) |
| Weight | ~350 g (incl. batteries) |
| Backup Power | Rechargeable lithium cell (real-time clock only) |
| Accessories Included | Carrying pouch, 4 × AA alkaline batteries, paper holder, user manual, ACAP4 thermal paper (1 roll), calibration report, registration card |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1100E / HD-1100K |
| Measurement Range | E-type: −200 to +800°C |
| K-type | −200 to +1370°C |
| Accuracy | ±(0.05% of reading + 0.2°C) at 0°C (0.1°C resolution range) |
| Resolution | 0.1°C (−104.9 to +504.9°C for both E & K), otherwise 1°C |
| Waterproof Rating | IPX5 |
| Display | Large LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) |
| Data Logging | Up to 9999 records, 9 programmable intervals, manual trigger, playback & PC transfer via AMS-100 software |
| Compliance | CE, RoHS |
| Operating Environment | 0–40°C, 0–80% RH (non-condensing) |
| Dimensions | 76 × 167 × 36 mm (W×H×D) |
| Weight | ~350 g (incl. batteries) |
| Input | Single-channel thermocouple (E or K type), integrated cold-junction compensation, max input resistance 500 Ω |
| Sampling Rate | ~300 ms |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1150E / HD-1150K |
| Temperature Range (E-type) | −200 to +800 °C |
| Temperature Range (K-type) | −200 to +1370 °C |
| Resolution | 0.1 °C (−104.9 to +504.9 °C), 1 °C elsewhere |
| Accuracy (0.1 °C range, ≥0 °C) | ±(0.05% of reading + 0.2 °C) |
| Accuracy (0.1 °C range, <0 °C) | ±0.5 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C (at 25 °C ±10 °C) |
| IP Rating | IPX5 |
| Display | Backlit LCD |
| Battery Life | Up to 300 hours (4 × AA alkaline) |
| Dimensions | 76 × 167 × 36 mm (W×H×D) |
| Weight | ~350 g (including batteries) |
| Compliance | CE, RoHS, IEC 60584-1:2013 |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1250E / HD-1250K |
| Temperature Range (E-type) | −200 to 800 °C |
| Temperature Range (K-type) | −200 to 1370 °C |
| Accuracy (0 °C, 0.1 °C resolution) | ±(0.05% of reading + 0.2 °C) |
| Accuracy (0 °C, 1 °C resolution) | ±(0.1% of reading + 1 °C) |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 °C |
| Temperature Coefficient | ±0.01% F.S./°C |
| IP Rating | IPX5 |
| Display | Backlit LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) |
| Dimensions | 76 × 167 × 36 mm (W × H × D) |
| Weight | ~350 g (incl. batteries) |
| Compliance | CE, RoHS |
| Input | Single-channel thermocouple (E or K type), ANP connector |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Sampling Rate | ~300 ms |
| Data Logging | Up to 9999 records, programmable interval (9 options), manual trigger, peak/valley hold, playback, PC transfer via AMS-100 software |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1350E / HD-1350K |
| Temperature Range (E-type) | −200 to 800 °C |
| Temperature Range (K-type) | −200 to 1370 °C |
| Resolution | 1 °C or 0.1 °C (auto-switching) |
| Accuracy (0.1 °C mode) | ±(0.05% of reading + 0.2 °C) from 0 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 °C ±10 °C |
| Sampling Rate | ~300 ms |
| Input | Single-channel thermocouple (E or K standard |
| Display | Backlit LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) or optional AC adapter |
| IP Rating | Waterproof housing (IEC 60529 IP54 equivalent) |
| Compliance | CE, RoHS |
| Dimensions | 76 × 167 × 36 mm (W×H×D, excl. protrusions) |
| Weight | ~350 g (incl. batteries) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 89800-01 |
| Input Voltage | 115 V AC, 15 A |
| Max. Control Output Power | 2300 W |
| Temperature Resolution | 0.1 °C |
| Supported Thermocouple Types | J, K, T, E, N, R, S, B |
| Optional Sensors | RTD (Pt100), Thermistor |
| Display | LED |
| Control Algorithm | PID with Auto-Tuning |
| Temperature Units | °C, °F, K, °R |
| Over-Temperature Protection | User-Configurable |
| Alarm | Visual and Audible |
| Memory | Non-Volatile EEPROM |
| Enclosure Dimensions (L×W×H) | 18.5 × 25.4 × 9.4 cm |
| Compliance | CE, RoHS |
| Brand | Davis Instruments |
|---|---|
| Origin | USA |
| Model | 6420 |
| Sensor Type | Artificial Leaf Resistive Sensor |
| Excitation Voltage | 3 V (nominal, bipolar) |
| Time Constant | 2 s |
| Cable Length | 12 m |
| Cable Specification | 4-conductor, 26 AWG |
| Connector | Standard RJ-11 |
| Substrate Material | Fiberglass + Ceramic Board |
| Conductive Grid Material | Copper, Nickel, Gold |
| Mounting Bracket | Anodized Aluminum |
| Dimensions (L×W×H) | 102 mm × 58 mm × 58 mm |
| Weight | 0.4 kg |
| Output Range | 0–15 (dimensionless wetness index) |
| Accuracy | ±0.5 units |
| Resolution | 1 unit |
| Data Update Interval | 62.5–75 s |
| Compliance | Designed for outdoor agricultural and ecological monitoring per ASTM E2797-21 (Standard Practice for Measuring Leaf Wetness Duration) |
| Measurement Range | -30 °C to 1100 °C |
|---|---|
| Accuracy | ±0.5 °C |
| Resolution | 1 °C |
| Repeatability | ±1 °C |
| Spectral Band | 8–14 µm |
| Optical Field of View | Standard 2° or 15°, optional 60° |
| Emissivity Adjustment | 0.2–0.98 (user-selectable via rear panel) |
| Response Time | 0.1 s |
| Operating Ambient Temperature | -10 °C to 50 °C, ≤99% RH (non-condensing) |
| Storage Temperature | -10 °C to 50 °C |
| Lens Material | Dual-coated zinc selenide (ZnSe), MIL-C-13508 compliant |
| Output Signal | RS-232C standard, optional 1 mV/°C analog output |
| Power Supply | Rechargeable NiCd battery, 40 h continuous operation |
| Battery Charger | 120 V/60 Hz/3 W or 230 V/50 Hz optional |
| Minimum Measurement Distance | 2 cm |
| Maximum Measurement Distance | 300 m |
| Housing | Stainless steel |
| Origin | Imported |
| Manufacturer Type | Distributor |
| Brand | Graywolf |
|---|---|
| Model | TC-302HY |
| Type | K-Type Thermocouple Probe |
| Measurement Range | –80 °C to +205 °C |
| Output Sensitivity | ≈40 µV/°C |
| Probe Configuration | Subcutaneous (Needle-Type) |
| Sheath Material | Stainless Steel 316 |
| Lead Length | Standard 2 m (shielded, twisted-pair PTFE-insulated cable) |
| Connector | Miniature Thermocouple Connector (MJ) compatible with Graywolf handheld meters (e.g., Solo, DP-Calc, AirWolf series) |
| Compliance | RoHS-compliant construction |
| Calibration | NIST-traceable calibration certificate available upon request |
| Operating Environment | Indoor, non-explosive, non-corrosive ambient (IP54-rated probe tip when used with compatible host) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | ISOTECH Fixed-Point Blackbody Series (Indium, Zinc, Aluminum, Silver, Copper Points) |
| Cavity Diameter | 10 mm |
| Cavity Depth | 90 mm |
| Emissivity | >0.999 |
| Plateau Duration | >3 hours |
| Temperature Range | 156.60 °C (In) to 1084.62 °C (Cu) |
| High-Temperature Operation | Requires inert gas purge (N₂ or Ar) for Al/Ag/Cu points |
| R999 Mid-Temperature Reference Source | 30–550 °C, Cavity Ø45 mm × 285 mm depth |
| R426 High-Temperature Calibration Furnace | Sodium heat-pipe design, axial temperature gradient <0.01 °C/cm |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model Numbers | 17701, 17703, 465 |
| Application | High-Accuracy Temperature Fixed-Point Realization (In, Sn, Zn, Al) |
| Construction | Stainless Steel Core Tube with Parallel Wound Heating Element |
| Axial Temperature Gradient | <0.1 °C/cm in Working Zone |
| Plateau Duration | ≥20–40 h (dependent on cell type and thermal mass) |
| Control System | PID-Based Automatic Temperature Stabilization |
| Safety | Integrated Power-Fail Protection Circuitry |
| Compliance | Designed for use in accordance with ITS-90 realization protocols |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Type | Sealed or Open-Style Fixed-Point Cell |
| Certified Uncertainty | ±0.000070 °C (k = 1) |
| Purity | ≥99.99999% Ga (7N) |
| Compliance | Traceable to NPL and CIPM MRA |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 17402B |
| Operating Duration | 12–16 h |
| Cooling Initiation | Bottom-up thermal control |
| Compliance | Designed for ITS-90 fixed-point calibration workflows |
| Regulatory Context | Supports GLP-compliant temperature calibration traceability |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | ISOTower |
| Fixed-Point Options | Indium (156.5985 °C), Tin (231.928 °C), Zinc (419.527 °C), Aluminum (660.323 °C), Silver (961.78 °C) |
| Immersion Depth | 290 mm |
| Thermal Siphon Technology | Yes |
| Temperature Plateau Duration | ≥30 h |
| Ramp Time to Setpoint | ~2 h |
| Cell Purity | 99.9999% (6N) |
| Construction | Integrated crucible-furnace monoblock architecture |
| Compliance | Fully compatible with ITS-90 realization protocols |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 461 |
| Power Requirement | None |
| Operating Medium | Liquid Nitrogen (LN₂) |
| Construction | Stainless Steel Dewar Vessel with Insulated Lid |
| Calibration Reference Temperature | −196 °C (77 K) |
| Temperature Uniformity | ±0.05 °C (within central 25 mm axial zone, after thermal stabilization) |
| Probe Compatibility | Standard 6–8 mm diameter stem thermometers (glass, platinum resistance, thermocouple, or digital sensors) |
| Compliance | Designed in accordance with ISO/IEC 17025:2017 requirements for reference standards used in thermometer calibration |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 17724 |
| Certified Uncertainty | ±0.000220 °C |
| Purity | ≥99.99999% (7N) Mercury |
| Housing | Austenitic Stainless Steel (316L) |
| Thermometer Well Depth | Adjustable (Standard Depth: 150 mm, Customizable per ITS-90 Calibration Protocol) |
| Compliance | Fully Traceable to NPL and BIPM Standards |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 17725 |
| Temperature Setpoint Range | −36 °C to −42 °C |
| Cooling Time to Setpoint | ≤60 min |
| Cooling Rate | up to 1 K/min |
| Heating Rate | up to 2 K/min |
| Construction | Laboratory-grade stainless steel housing with insulated cryogenic chamber |
| Control System | Digital PID temperature controller with ±0.01 °C stability (at setpoint) |
| Compliance | Designed for use with ITS-90 traceable mercury triple-point cells (234.3156 K) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 414 |
| Maximum Operating Temperature | 1000 °C |
| Control System | Integrated Programmable Temperature Controller |
| Application | Annealing, Heat Treatment and Stabilization of Platinum Resistance Thermometers (PRTs) |
| Compliance | Designed for use in calibration laboratories adhering to ISO/IEC 17025, ASTM E1137/E2877, and IEC 60751 |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 459 |
| Temperature Range | −180 °C to −80 °C |
| Stability (30 min) | ±0.005 °C at −80 °C |
| Uniformity (between wells) | ±0.005 °C |
| Uniformity (axial, 50 mm from bottom) | ±0.005 °C at −80 °C |
| Immersion Depth | 560 mm |
| Well Diameter | 80 mm |
| Well Length | 480 mm |
| Number of Probe Wells | 4 |
| Neck Diameter | 120 mm |
| Vacuum Port Interface | RS-422 |
| Cooling Medium | Liquid Nitrogen |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 471 |
| Temperature Fixed Point | Argon Triple Point (−189.3442 °C) |
| Uncertainty (k=2) | 1.844 mK |
| Plateau Duration | ≥4 h |
| Accuracy | ±1 mK |
| Dimensions (H×W×D) | 1250 × 380 × 615 mm (Apparatus Height: 900 mm) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | POTS-SLIM |
| Type | Portable Dry-Block Fixed-Point Preservation Furnace |
| Heating Configuration | Triple-zone (main + upper/lower auxiliary heaters) |
| Vertical Temperature Uniformity | ±0.1 °C over fixed-point cell height |
| Operating Modes | Freezing Curve & Melting Curve Execution |
| Compliance | Designed for ITS-90 fixed-point realization and calibration traceability |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Type | Sealed and Open Configuration |
| Purity | 99.99995% (6N5) Metal |
| Fill Gas (Sealed) | Ultra-High-Purity Argon (99.9999% / 6N), at Standard Atmospheric Pressure |
| Working Length | >200 mm |
| Certification | UKAS-Accredited Calibration Certificate & Material Purity Certificate (per NPL/NPTL Test Protocol) |
| Compliance | Fully ITS-90 Compliant for Defining Primary Temperature Fixed Points |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | Slim Form |
| Purity | 6N (99.9999%) Argon-Sealed Metal |
| Compliance | ITS-90 Realization |
| Application | Secondary SPRT & High-Accuracy Industrial Sensor Calibration |
| Design | Compact, Portable Fixed-Point Cell Architecture |
| Longevity | >20 Years Field-Proven Stability |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 670,909 |
| Temperature Range | −200 °C to 1000 °C |
| Construction | Sealed recrystallized alumina sheath (Ø2.5 mm) |
| Compliance | ITS-90 primary interpolation standard |
| Type Options | R-type and S-type configurations |
| Reproducibility | < ±0.1 mK (at fixed points) |
| Drift Rate | < 10 mK per year (typical, under proper handling and storage) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | TRU937 |
| Reference Temperature Options | 0 °C (ice-point equivalent) or user-selectable range 45–70 °C |
| Channel Capacity | Up to 100 thermocouple inputs |
| Cooling Method | Solid-state Peltier cooling |
| Operating Environment | Rated for high-temperature ambient conditions |
| Compliance | Designed to meet IEC 60584, ASTM E230, and ISO 8573-1 thermal reference stability requirements |
| Alarm Function | Integrated over-temperature and sensor-fault alerting |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | A11, B11 |
| Calibration Certificate Option | UKAS-accredited with uncertainty ≤ 0.07 mK (k=2) |
| Design Type | A-type (integrated handle for handling & pressure indication), B-type (100 mm extended inner tube for full immersion) |
| Purification | 12-step vacuum distillation |
| Brand | Kaye |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Kaye Validator AVS |
| Pricing | Upon Request |
| Brand | Kaye |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | KAYE |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 240 |
| Channel Options | 2-channel (240-2P) or 8-channel (240-8P) |
| Temperature Range | 1 K to 800 K |
| Sensor Compatibility | Cernox®, Platinum RTDs, DT-670/DT-470 Diodes, Germanium, Carbon-Glass, RhFe, Rox™, GaAlAs |
| Excitation | 4-wire differential, constant current (10 µA) with polarity reversal |
| Isolation | Opto-isolated sensor inputs (channel-to-ground), non-isolated channel-to-channel |
| Communication | PROFIBUS-DP v1, USB 2.0 |
| Display | 128×32-pixel OLED, dual-parameter real-time readout (K/°C/°F/V/Ω), update rate: 2 Hz |
| Calibration | User-loadable 200-point curves per channel |
| Mounting | DIN-rail compatible, rear busbar for shared power & fieldbus |
| Compliance | CE, RoHS, PROFIBUS Nutzerorganisation (PNO) certified |