Other Non-destructive Testing Equipment
Filter
Showing 1–30 of 96 results
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA 3D |
| Frequency Bandwidth | 10–100 kHz |
| Parallel DAQ Channels | 32 |
| Maximum Penetration Depth | 3 m (concrete-dependent) |
| Maximum Coverage Area | 10 × 10 m |
| Frame Rate | 25 Hz (2D), 2 Hz (3D) |
| Battery Life | Up to 10 h per charge |
| Sensor Configuration | 4 × 8 A-DPC® array (expandable) |
| Compliance | T/CECS XXX-202X, JGJ/T 485-2019, DB32/T 3754-2020, DB34/T 5072-2017, DB37/T 5106-2018, DG/TJ 08-2252-2018, DB13(J)/T 8327-2019, DBJ/T-199-2020 |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA 3D Pro |
| Frequency Bandwidth | 10–100 kHz |
| Parallel DAQ Channels | 64 |
| Maximum Penetration Depth | 4 m (concrete-dependent) |
| Maximum Scanning Area | 10 × 10 m |
| Frame Rate | 12 Hz (2D), 0.3 Hz (3D) |
| Battery Life | Up to 10 h per charge |
| Sensor Configuration | 4 × 16 or 8 × 8 A-DPC® array (expandable) |
| Compliance | T/CECS XXX-202X, JGJ/T 485–2019, DB32/T 3754–2020, DB34/T 5072–2017, DB37/T 5106–2018, DG/TJ 08–2252–2018, DB13(J)/T 8327–2019, DBJ/T–199–2020 |
| Brand | ACS |
|---|---|
| Origin | Hong Kong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A1052 MultiSONIC |
| Price Range | USD 1–2 (Unit Price Indicative |
| Channels | 32-channel pulser-receiver array |
| Connectivity | Integrated Wi-Fi interface (IEEE 802.11 b/g/n, 2.4 GHz) |
| Power Supply | Rechargeable Li-ion battery (operational autonomy ≥ 6 h) |
| Excitation | Bipolar pulse burst with user-defined frequency, half-cycle duration, and number of half-cycles |
| Compatible Transducers | All ACS dry-point contact ultrasonic transducers (e.g., A101x series, 20–500 kHz nominal bandwidth) |
| Encoding Support | Golay complementary sequence excitation (length up to 64 bits) |
| Software | MATHILDA32 (free demonstration version included) |
| Operating Modes | Pulse-echo, through-transmission, pitch-catch |
| Compliance | CE, RoHS, FCC Part 15 Subpart B |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1410 Pulsar |
| Price | USD 6,800 (FOB Italy) |
| Brand | ACS |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA |
| Pricing | Upon Request |
| Brand | ADVANTEST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TS9001 TDR Analysis System |
| Price | USD 70,000 (FOB Shanghai) |
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Zhengye XG5120 |
| Quotation | Available Upon Request |
| Detection Efficiency | ≥60 ppm |
| False Positive Rate | ≤2% |
| False Negative Rate | 0% |
| Yield Accuracy | 99.5% |
| Measurement Resolution | 40 µm |
| Radiation Dose Rate | ≤1 µSv/hr (per IEC 61000-4-2 & ISO 13783 compliance) |
| Origin | Liaoning, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ALL-5800B |
| Pricing | Upon Request |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | ARB-IPR-1210 (PCI-E) |
| Bus Interface | PCI Express |
| ADC Resolution | 12-bit |
| Sampling Rate | 100 MSPS (selectable: 100/50/25/10/5 MSPS) |
| Input Bandwidth | 0.5–30 MHz (+3 dB) |
| Gain Range | –20 to +80 dB (0.1 dB step) |
| Pulse Generator | Up to 400 V peak (<5 ns rise time), programmable pulse width & damping |
| DAC Memory | 128 KB RAM (64K points) |
| Trigger Modes | Software, external TTL, signal threshold |
| Gate Count | 4 independent gates |
| Time-of-Flight Resolution | 16-bit (10 ns) |
| Amplitude Resolution | 12-bit (488 µV) |
| Operating Temperature | 5–40 °C |
| Form Factor | Full-length PCI-E card |
| Compliance | RoHS, CE, FCC Class A |
| Software Support | LabVIEW and C++ drivers included |
| Standards Compatibility | Designed for ASTM E1158, ISO 12718, and EN 12668-1 compliant ultrasonic testing workflows |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | ALL-5800A |
| Pricing | Upon Request |
| Input Voltage | 220 V AC, 50 Hz |
| X-ray Tube | Cu anode, air-cooled, 30 kV max tube voltage, 0–5 mA tube current |
| Detector | Geiger–Müller counter |
| Time Constant Settings | 1 s / 2 s / 3 s |
| Angular Display Reference | Certified Si or Al₂O₃ standard wafer/rod |
| Angular Adjustment Mechanism | Dedicated ±4° two-axis manual fine-adjustment fixture with symmetrical locking |
| Positioning Accuracy Reference | 0.5 mm feeler gauge |
| Sample Stage Translation (X-axis) | Motorized, auto-limited |
| Vertical Lift (Z-axis) | Motorized |
| Rotational Axis (θ) | Motorized, full 360° continuous rotation |
| Beam Shutter | Motorized |
| Dimensions (L×W×H) | 1025 × 1230 × 1950 mm |
| Weight | 620 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AOLONG2 |
| Pricing | Upon Request |
| Brand | Astroda |
|---|---|
| Model | XG5120 |
| Origin | Guangdong, China |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (per IEC 61331-1 & FDA 21 CFR §1020.40) |
| Throughput | ≥30,000 units/day |
| Reconfiguration Time | 0.5–2 h |
| Compliance | CE, ISO 13485 (for medical device manufacturing support), GB/T 18871-2002, IEC 62495 |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XG5130 |
| Pricing | Available Upon Request |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-4-3 & IEC 62471) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-HIKARI 10 (Peach-Specific) |
| Measurement Principle | Near-Infrared Absorption at ~940 nm |
| Measurement Range | Brix 8.0–20.0% |
| Temperature Range | 5.0–35.0°C |
| Brix Resolution | 0.1% |
| Temperature Resolution | 0.1°C |
| Brix Accuracy | ±1.5% (Brix), ±1.0°C (Temperature) |
| IP Rating | IP64 |
| Power | 2×AAA Alkaline Batteries |
| Dimensions | 6.1 × 4.4 × 11.5 cm |
| Weight | 120 g (main unit only) |
| Automatic Temperature Compensation | 5.0–35.0°C |
| Data Offset Correction Function | Yes |
| Sample Interface | Contact-type optical probe with integrated temperature sensor |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PAL-HIKARi 15 |
| Pricing | Available Upon Request |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-HIKARi Ripeness |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measurement Range | Maturity 0–100% (unitless index), Temperature 5.0–35.0 °C |
| Resolution | Maturity 1%, Temperature 0.1 °C |
| Accuracy | ±5% for maturity (varies by fruit species and measurement conditions), ±1 °C for temperature |
| Auto Temperature Compensation | 5.0–35.0 °C |
| Power Supply | 2 × AAA alkaline batteries |
| Ingress Protection Rating | IP64 |
| Dimensions | 6.1 × 4.4 × 11.5 cm |
| Weight | 120 g (instrument only) |
| Data Storage | Up to 100 measurements |
| Data Transfer | NFC-enabled (to smartphones or PCs) |
| Sample Interface | Contact-type optical sensor with light-shielding gasket |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | CoreScan / Sherescan |
| Pricing | Available Upon Request |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | Q-800 |
| Excitation Compatibility | Thermal, Vacuum, Vibration |
| Measurement Principle | Laser Speckle Shearing Interferometry |
| Field of View | Configurable from 10 × 10 cm to 2 m² |
| Acquisition Time | ≤30 s per 2 m² area |
| Compliance | NAS410 / EN4179 certified methodology |
| Target Materials | CFRP, aluminum alloys, honeycomb composites, bonded structures |
| Defect Sensitivity | Delaminations, disbonds, wrinkles, impact damage, core crush, foreign object inclusions, voids, moisture ingress, repair anomalies |
| Brand | Dantec Dynamics |
|---|---|
| Origin | Germany |
| Model | Q-810 |
| Type | Full-Field, Non-Contact Optical Shearography NDT System |
| Compliance | Designed for ASTM E2657, ISO 12718, and EN 13715-compliant shearographic inspection workflows |
| Application Scope | In-situ, large-area structural integrity assessment of composite and metallic components |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P2+ |
| Pricing | Available Upon Request |
| Brand | Lightigo |
|---|---|
| Origin | Czech Republic |
| Model | FireFly |
| Measurement Principle | Laser-Induced Breakdown Spectroscopy (LIBS) |
| Detection Range | Li to U (nearly all elements in the periodic table) |
| Detection Limit | 1–100 ppm (matrix-dependent) |
| Spatial Resolution | 10–150 µm |
| Imaging Mode | 2D surface mapping & depth-resolved (line-scan or layer-by-layer ablation) |
| Max Scan Area | 100 mm × 100 mm |
| Ablation Rate | Up to 100 Hz |
| Sample Type | Solid materials only (conductive and non-conductive, no vacuum required) |
| Operating Environment | Ambient air or controlled atmosphere (N₂, Ar) |
| Compliance | CE-marked |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | FERITSCOPE MP30E-S |
| Measurement Principle | Magnetic Induction (DIN EN ISO 2178) |
| Measurement Range | 0.1–80 % Fe or 0.1–110 FN |
| Display | Dual-line, 16-character LCD |
| Data Capacity | 100 programs / 1,000 data blocks / up to 10,000 measurements |
| Probe Interface | Auto-identifying plug-in connector |
| Communication | Bidirectional RS232 |
| Power Supply | 9 V alkaline or rechargeable battery, or AC adapter |
| Dimensions | 160 × 80 × 30 mm |
| Weight | 230 g (without battery) |
| Compliance | ANSI/AWS A4.2-91, DIN 32514, IIW Traceable Calibration Standards |
| Included Accessories | Protective cover, carrying case, battery, operator manual |
| Optional Probes | EGAB1.3-Fe (coaxial), EGABI1.3-Fe (internal surface/contour), EGABW1.3-Fe (90° angled) |
| Calibration Kits | Four certified WRC-92 traceable standard sets (0.3/10, 1.5/30, 10/80 %Fe |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fischer PMP10 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XDLM-PCB |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-RAY |
| Pricing | Available Upon Request |
| Brand | Force |
|---|---|
| Origin | Denmark |
| Model | ERE 20 |
| Type | Embedded Half-Cell Reference Electrode |
| Electrode Material | Manganese Dioxide (MnO₂) |
| Electrolyte pH | ~13.5 |
| Housing | Stainless Steel (AISI 316) |
| Ionic Membrane | Cementitious Mortar |
| Input Impedance Requirement | >100 MΩ |
| Compliance | EN 12696:2016, ASTM C876, ISO 15663-2 |
| Installation | Embeddable in Fresh or Existing Concrete |
| Output Interface | Standard BNC or Screw-Terminal Voltage Output |
| Operating Temperature Range | −10 °C to +60 °C |
| Long-Term Drift | < ±2 mV/year (typical, under stable alkaline conditions) |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | MagStress5c |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) Analysis |
| Portability | Integrated battery-powered handheld unit with touch display and USB interface |
| Compliance | Designed for field-deployable NDT per ISO 10893-13 and ASTM E3027 guidelines |
| Sample Type | Ferromagnetic metallic components (e.g., bearing races, gear teeth, camshafts, turbine blades) |
| Output | Real-time MBN amplitude & frequency spectrum, quantitative burn index, pass/fail classification |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HRS-5A |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | InspectIR |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR 400KA |
| Pricing | Available Upon Request |