| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aesthesio |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aesthesio (Animal Activity Cage Sold Separately) |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BIO-CHP (for Mice and Rats) |
| Pricing | Upon Request |
| Temperature Range | −3 °C to +65 °C (at ambient 20–25 °C, 50% RH) |
| Temperature Accuracy | ±0.5 °C |
| Cooling Time (RT → 4 °C) | <10 min |
| Heating Time (4 °C → 65 °C) | ≤5 min |
| Control Options | Manual Interface or Footswitch |
| Real-Time Display | Animal Response Latency & Plate Temperature |
| Programmable Profiles | Software-Defined Ramp/Cycle Sequences |
| Base Plate Dimensions | 165 × 165 mm |
| Main Unit Dimensions | 305 × 280 × 158 mm |
| Weight | 6.65 kg |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BIO-TGT2 |
| Pricing | Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BIO-EVF3 |
| Price | Upon Request |
| Measurement Range | 0–500 g (0–5 N) |
| Resolution | 0.1 g |
| Accuracy | ±0.2 g |
| Internal Memory | 100 Test Records |
| Includes | 10 Disposable Plastic Filaments + 1 Elastic Filament (Rat/Mouse Compatible) |
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BIO-T2CT (supports 1 rat or 2 mice |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BIO-TGT2 (Supports 1 Rat or 2 Mice Simultaneously) |
| Pricing | Available Upon Request |
| Temperature Range | 5–55 °C (±1 °C stability under 20–25 °C ambient, 45–55% RH) |
| Gradient Platform Length | 120 cm |
| Data Output Parameters | Total Trial Duration, Real-Time Zone Temperatures (up to 20 discrete zones), Dwell Time per Zone, Cumulative Locomotor Distance |
| Data Integrity | AES-256 Encrypted Acquisition with Frame-Synchronized Video Logging |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2888 (Tri-Modality), 2889 (Quad-Modality), 2890 (Penta-Modality) |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7280 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BIO-CHP |
| Pricing | Upon Request |
| Temperature Range | –3 °C to 65 °C (at ambient 20–25 °C, 50% RH) |
| Temperature Accuracy | ±0.5 °C |
| Cooling Time (RT → 4 °C) | <10 min |
| Heating Time (4 °C → 65 °C) | 5 min |
| Control Modes | Manual, Footswitch, Software-Programmable Ramp/Cycle |
| Real-Time Display | Animal Response Latency & Plate Temperature |
| Base Plate Dimensions | 165 × 165 mm |
| Main Unit Dimensions | 305 × 280 × 158 mm |
| Weight | 6.65 kg |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 37550 |
| Price Range | USD 7,000 – 14,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aesthesio |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | EVF3 |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TFA |
| Pricing | Upon Request |
| Brand | IITC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 600M (Mouse) / 600R (Rat) Dual-Paw Weight-Bearing Nociception Analyzer |
| Dimensions (H×W×D) | 31 cm × 30 cm × 25 cm |
| Weight | 2.6 kg (instrument only, excluding pedals, restraint, and power cord) |
| Max Load per Paw | 2200 g |
| Resolution | 0.05 g (<500 g), 0.1 g (full scale) |
| Accuracy | ±0.5% FS |
| Data Output Format | .csv (Excel-compatible) |
| Internal Storage | 4 GB (≥10,000 assays) |
| Measurement Duration | 1–360 s |
| Trigger Mode | Manual or Auto-Start (Ugo Basile–inspired activation logic) |
| Power Supply | 90–260 VAC, fanless design |
| Compliance | GLP-compliant data logging architecture, audit-ready metadata tagging |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 600MR |
| Pricing | Upon Request |
| Measurement Range | 0–1000 g |
| Resolution | 1 g |
| Test Duration | 5–999 s (user-adjustable) |
| Platform Dimensions | 18″ × 18″ |
| Animal Weight Capacity | 180–270 g (optimized for adult mice and small rats) |
| Input Method | Keypad + Optional Footswitch |
| Data Output | RS-232 Serial Interface, Optional Thermal Printer Support |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 390 or 390G (Capacity: 6 Rats or 12 Mice) |
| Pricing | Available Upon Request |
| Brand | IITC |
|---|---|
| Origin | USA |
| Model | PE34 |
| Temperature Range | 0–70 °C |
| Temperature Resolution | 0.1 °C |
| Ramp Rate | 1–10 °C/min |
| Temperature Stability | ±0.1 °C |
| Plate Dimensions | 4" × 8" (10.2 cm × 20.3 cm) |
| Display Resolution | Time to 0.01 s |
| Interface | RS-232 (standard), USB (optional), Footswitch, Printer Output |
| Enclosure | Transparent Animal Restraint Chamber |
| Control | Front-panel Programmable Digital Microprocessor |
| Standby Recovery | Automatic Return to Pre-set Idle Temperature |
| Brand | IITC |
|---|---|
| Origin | USA |
| Model | 2450 |
| Measurement Resolution | 0.01 g |
| Actuation Method | Foot-pedal zeroing |
| Output | Real-time digital display of withdrawal threshold and peak force |
| Animal Compatibility | Rats and mice |
| Primary Assay Type | Mechanical nociceptive threshold testing (Randall-Selitto alternative) |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | BIO-TGT2 (supports 1 rat OR 2 mice simultaneously) |
| Temperature Range | 5–55 °C (±1 °C stability under 20–25 °C ambient, 45–55% RH) |
| Gradient Length | 120 cm heated/cooled linear floor |
| Data Output | Total trial duration, real-time temperature per zone (up to 20 discrete zones), dwell time per zone, cumulative locomotion distance |
| Data & Video | AES-256 encrypted synchronized recording with timestamp alignment |
| Compliance | GLP-compliant audit trail, metadata-embedded video export, FDA 21 CFR Part 11–ready configuration options |
| Brand | RWD |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 336 Paw-and-Tail Nociception Analyzer |
| Pricing | Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 31300 (for Mice and Rats, Includes Control & Analysis Software) |
| Pricing | Available Upon Request |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 37140 |
| Measurement Resolution | 0.01 mL |
| Available Cuvette Diameters | 1.3 cm (mouse), 1.8 / 2.5 / 3.5 cm (rat) |
| Interface | RS-232 or USB |
| Compliance | Designed for GLP-compliant preclinical inflammation studies |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 37450 |
| Force Range | 0–50.0 g (0.5 g resolution) |
| Force Ramp Rate | 1–20 s per increment (1 s resolution) |
| Stimulator Travel Distance | 12 mm |
| Timing Resolution | 0.1 s |
| Power Supply | 85–264 VAC, 50–60 Hz, ≤20 W |
| Net Weight | 10.20 kg |
| Interface | 9-pin DELTA serial port |
| Data Storage | Internal memory with USB flash export capability |
| Cage Configuration | Modular grid-based enclosure (3–12 interchangeable compartments) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 38450 |
| Force Range | 0–1000 g |
| Force Resolution | 0.1 g |
| Observation System | Integrated Triangular Prism Viewing Platform |
| Data Storage | Onboard memory for >100 test sessions |
| Stimulus Control | User-adjustable ramp rate and inter-stimulus interval |
| Compliance | Designed for GLP-compliant rodent nociception studies |
| Accessories | Optional grip bar, mesh floor platform (5 × 5 mm² laser-cut apertures, 1 mm spacing), calibrated von Frey filament sets (37450/277, 0.008–300 g) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 38500 |
| Force Resolution | 0.1 g |
| Maximum Applied Force | 1500 gf |
| Species-Specific Sensors | Rat & Mouse |
| Optional Accessory | Paw Pressure Sensor Module |
| Compliance | Designed for ASTM F2796-21–aligned behavioral nociception protocols |
| Software Interface | USB-connected digital readout with real-time force curve export (CSV/TXT) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 47302 (Rat) / 47303 (Mouse) |
| Speed Range | 3–100 m/min (1 m/min increments) |
| Incline Range | −25° to +25° (5° steps) |
| Electric Stimulus | 0–2 mA (0.1 mA resolution) |
| Channel Configuration | 3 lanes (rat, 45 × 11 cm each) / 6 lanes (mouse, 45 × 5.5 cm each) |
| Frame Height | 15 cm (rat) / 7 cm (mouse) |
| Belt Material | Food-grade polymer with optimized traction |
| Data Output | USB export (TXT, Excel, PDF) |
| Control Interface | 4.3" capacitive touchscreen |
| Software | Integrated acquisition & analysis suite with audit-ready metadata tagging, hierarchical result tree, customizable layout, and GLP-compliant session annotation |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | BIO-T2CT |
| Temperature Range | –3 °C to 65 °C |
| Temperature Accuracy | ±0.5 °C |
| Chamber Dimensions (L×W×H) | 33 cm × 16.5 cm × 30 cm |
| Overall Unit Dimensions (L×W×H) | 32 cm × 57 cm × 45.5 cm |
| Species Compatibility | 1 rat or 2 mice |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 31300 |
| Thermal Stimulation Range | Ambient Temperature to 70 °C |
| Mechanical Stimulus Levels | 5 Adjustable Force Steps |
| Data Acquisition Channels | Up to 16 Independent Cages |
| Behavioral Metrics | Feeding Duration (Min/Max/Mean), Feeding Attempts Count |
| Software Included | Yes |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 33 or 33T |
| Light Source Intensity Range | 0–250 (arbitrary units, ±1% accuracy) |
| Focal Spot Size | 4 × 6 mm |
| Reaction Time Resolution | 0.01 s |
| Preheating Temperature Range | 0–75 °C |
| Automatic Cut-off Timer | User-configurable |
| Data Output | RS-232 serial interface + thermal printer support |
| Compliance | Designed for GLP-compliant preclinical analgesia studies |