| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | CY-SXT-02 |
| Temperature Range | Room Temp +5°C to 100°C |
| Channel Capacity | 2/4/6 parallel extraction positions |
| Sample Weight per Vessel | 0.5–20 g |
| Extraction Flask Volume | 500 mL (2-channel) |
| Heating Power | 300 W |
| Power Supply | 220 V ±10 V, 50 Hz |
| Dimensions (W×D×H) | 425×230×840 mm |
| Net Weight | 17 kg |
| Compliance | Designed in accordance with GB 5512–1985 for crude fat determination |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr CUS 2 |
| Pricing | Available Upon Request |
| Material | Borosilicate Glass (Compliant with ISO 9377-2) |
| Configuration | Dual-Column Parallel Setup |
| Weight | ~3 kg |
| Dimensions (W×D×H) | ~23 × 27 × 50 cm |
| Included Components | Support Stand, Two 100 mL Graduated Collection Flasks, Two Purification Columns (Part No. 2804800203), Two Dropping Funnels, Two Kuderna-Danish Concentration Vessels |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ET2 |
| Price | Upon Request |
| Dimensions (W×H×L) | 14.0 × 10.0 × 27.0 cm (unit only) |
| Weight | ~17 kg |
| Voltage | 220 V / 50 Hz |
| Max. Power Output | 2200 W |
| Load Type | Resistive (Ohmic), 4-pole threaded connector |
| Sensor | PT100, 3-wire configuration, via 3-pole screw terminal |
| Control Principle | PID with anti-drift compensation |
| Temp. Range | 20–450 °C |
| Temp. Accuracy | ±1 K |
| Time Range | 1–999 min (±1 min), continuous heating mode enabled |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr EX1000 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KEX Compact Soxhlet Extraction System |
| Pricing | Available Upon Request |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Current | 3 A / 6 A |
| Power Rating | 450 W |
| Weight | ~7.5 kg |
| Dimensions (W×D×H) | ~23 × 33 × 71.5 cm (KEX 30) / ~23 × 33 × 80 cm (KEX 100) |
| Extraction Vessel Capacity | 30–500 mL |
| Sample Throughput | 1 sample per unit (compact configuration) |
| Condenser Interface | Standard threaded joint (compatible with Weibull/Stoldt acid hydrolysis units) |
| Drain Valve | Integrated piston valve for post-extraction solvent transfer |
| Cooling Requirement | Compatible with UK 12/400 recirculating chiller (380 W) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Behr KSMA |
| Pricing | Upon Request |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Current | 3 A / 6 A |
| Power Consumption | 450 W |
| Weight | approx. 6 kg |
| Dimensions (W × D × H) | approx. 230 × 330 × 800 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr R-Series Multi-Sample Soxhlet Extraction System |
| Pricing | Available Upon Request |
| Configuration Options | 4-position & 6-position variants |
| Solvent Reservoir Capacity | 100 mL, 250 mL, or 300 mL per extraction chamber |
| Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Power Consumption | 1140 W (4-position), 2160 W (6-position) |
| Current Rating | 8 A / 16 A (230 V), 10 A / 20 A (115 V) |
| Net Weight | ~15.1 kg (4-position), ~19.8 kg (6-position) |
| Dimensions (W×D×H) | ~530 × 320 × 740 mm (4-position), ~760 × 320 × 740 mm (6-position) |
| Condenser Cooling | Dual-path分流 water jacket with independent flow control per channel |
| Heating Control | Individual PID-regulated heating blocks per sample position |
| Safety Features | Overtemperature cutoff, solvent vapor containment design, drip-resistant condenser interface |
| Compliance | Designed in accordance with DIN EN ISO 14555 and AOAC Official Method 991.36 for fat determination |
| Brand | Beifen Sanpu |
|---|---|
| Model | SXT-6 |
| Channels | 6 |
| Extraction Flask Volume | 250 mL per channel |
| Sample Capacity | 0–5 g per channel |
| Temperature Control Range | Ambient +5 °C to 100 °C |
| Heating Power | 800 W |
| Power Supply | 220 V ±10 V, 50 Hz |
| Dimensions (W×D×H) | 725 × 230 × 740 mm |
| Weight | 25 kg |
| Compliance | GB 5512–1985 |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Model | SEM-06 |
| Extraction Chamber Volume | 30 mL |
| Receiving Flask Volume | 100 mL |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Control Accuracy | ±1°C |
| Number of Channels | 6 |
| Power Supply | 220 V ±10 V, 50 Hz |
| Heating Power | 800 W |
| Dimensions (W×D×H) | 740 × 230 × 650 mm |
| Net Weight | 23 kg |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SXT-02 |
| Extraction Capacity | 2 samples per batch |
| Sample Mass Range | 0.5–20 g per sample |
| Extraction Flask Volume | 500 mL per flask |
| Temperature Control Range | Ambient +5 °C to 100 °C |
| Heating Power | 300 W |
| Voltage/Frequency | 220 V ±10 V / 50 Hz |
| Dimensions (W×D×H) | 750 × 360 × 550 mm |
| Net Weight | 16 kg |
| Solvent Recovery | Automated |
| Timer with Audible Alarm | Yes |
| Application Scope | Cereals, feedstuffs, oilseeds, soil, and other solid matrices |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SXT-06 |
| Extraction Chamber Volume | 60 mL per channel |
| Receiver Flask Volume | 150 mL |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Control Accuracy | ±1°C |
| Number of Channels | 6 |
| Power Supply | 220 V ±10 V, 50 Hz |
| Heating Power | 800 W |
| Dimensions (W×D×H) | 550 × 320 × 626 mm |
| Net Weight | 23 kg |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | E-500 SOX / E-500 SOX LSV |
| Extraction Chamber Volume | 65–120 mL |
| Receiving Flask Volume | 150–250 mL |
| Temperature Range | 30–200 °C |
| Temperature Control Accuracy | ±1% of setpoint |
| Number of Parallel Channels | 6 |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | E-800 / E-800 LSV |
| Extraction Chamber Volume | 130–220 mL |
| Receiving Flask Volume | 150–250 mL |
| Temperature Range | 30–400 °C |
| Temperature Control Accuracy | ±1% of setpoint |
| Number of Parallel Channels | 6 |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported |
| Model | H-506 |
| Extraction Chamber Volume | 84–216 mL |
| Receiver Flask Capacity | up to 500 mL |
| Temperature Range | 70–495 °C |
| Temperature Control Accuracy | ±3 °C |
| Number of Channels | 6 |
| Dimensions (W × D × H) | 312 × 614 × 470 mm |
| Net Weight | 13 kg |
| Power Consumption | 1200 W |
| Voltage | 220–240 VAC (±10 %) |
| Frequency | 50/60 Hz |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ORACLE |
| Quotation | Upon Request |
| Extraction Chamber Volume | 10 mL |
| Receiving Bottle Volume | 110 mL |
| Temperature Range | Ambient |
| Temperature Control Accuracy | ±1°C |
| Number of Channels | 1 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DRK-SOX316 |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Control Accuracy | ±1°C |
| Number of Channels | 6 |
| Sample Weight Capacity | 0.5–15 g |
| Extraction Efficiency Improvement vs. Classical Method | 20–80% reduction in time |
| Solvent Recovery Rate | ≥85% |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Rated Power | 2.0 kW |
| Dimensions (L×W×H) | 658 × 345 × 720 mm |
| Net Weight | 50 kg |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Model | DRK-SOX316 |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Control Accuracy | ±1°C |
| Number of Extraction Channels | 6 |
| Sample Weight Capacity | 0.5–15 g |
| Heating Cup Volume | 150 mL |
| Solvent Recovery Rate | ≥85% |
| Repeatability Error | ≤1% |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Rated Power | 2.0 kW |
| Dimensions (L×W×H) | 658 × 345 × 720 mm |
| Net Weight | 50 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | EX-TE-03 / EX-TE-05 / EX-TE-10 / EX-TE-30 / EX-TE-50 / EX-TE-100 |
| Quotation | Available Upon Request |
| Vessel Capacity | 3–100 L |
| Jacket Design Pressure | 0.3–0.4 MPa |
| Internal Design Pressure | 0.09 MPa |
| Heating Power | 3–15 kW |
| Agitation Power | 0.09–0.5 kW |
| Optional Ultrasonic Frequency Range | 15–60 kHz |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Application | Rapid total fat determination in food and feed samples |
| Sample throughput | 15 positions |
| Sample mass range | 3–15 g |
| Total process time | ≤ 3 hours |
| Temperature control | Full-vessel infrared temperature monitoring |
| Automation | Integrated balance interface for automatic mass data import and calculation |
| Extraction methodology | Microwave-assisted acid hydrolysis coupled with solvent extraction |
| Stirring | Built-in magnetic stirring system |
| Compliance context | Designed to support AOAC 991.36, ISO 1443, and USP <467> workflows |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EX-TE |
| Pricing | Available Upon Request |
| Vessel Capacities | 3 L, 5 L, 10 L, 30 L, 50 L, 100 L |
| Heating Power | 3–15 kW |
| Agitation Power | 0.09–0.5 kW |
| Design Pressure (Inner Vessel) | 0.09 MPa |
| Design Pressure (Jacket) | 0.3–0.4 MPa |
| Temperature Control | Dual-point (Extraction & Jacket) |
| Safety Features | Low-level liquid protection, real-time temperature monitoring |
| Optional Ultrasound Module | Frequency range 15–60 kHz (focused transducer array, frame-type agitator integration) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EX-TE-03 / EX-TE-05 / EX-TE-10 / EX-TE-30 / EX-TE-50 / EX-TE-100 |
| Capacity | 3–100 L |
| Design Pressure (Vessel) | 0.09 MPa |
| Design Pressure (Jacket) | 0.3–0.4 MPa |
| Heating Power | 3–15 kW |
| Stirring Power | 0.09–0.5 kW |
| Temperature Control | Integrated PID with Digital Display |
| Optional Ultrasonic Frequency Range | 15–60 kHz |
| Safety Features | Low-Level Liquid Protection, Dual-Temperature Monitoring, Expandable Multi-Unit Synchronization |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EX-TE-03 / EX-TE-05 / EX-TE-10 / EX-TE-30 / EX-TE-50 / EX-TE-100 |
| Capacity | 3–100 L |
| Design Pressure (Vessel) | 0.09 MPa |
| Design Pressure (Jacket) | 0.3–0.4 MPa |
| Heating Power | 3–15 kW |
| Agitation Power | 0.09–0.5 kW |
| Temperature Control Range | Ambient to 120 °C |
| Optional Ultrasonic Frequency | 15–60 kHz |
| Compliance | Designed for GLP-compliant R&D environments |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | EX-TE |
| Pricing | Available Upon Request |
| Vessel Capacities | 3–100 L (6 Models: EX-TE-03 to EX-TE-100) |
| Design Pressure (Inner Vessel) | 0.09 MPa |
| Jacket Design Pressure | 0.3–0.4 MPa |
| Heating Power | 3–15 kW |
| Agitation Power | 0.09–0.5 kW |
| Temperature Control Range | Ambient to 120 °C |
| Optional Ultrasonic Frequency Range | 15–60 kHz (Pulsed or Continuous Mode) |
| Integrated Sensors | Real-time monitoring of extraction temperature, heating temperature, pH, vacuum level, agitation speed/type, and liquid level |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Soxtec 8000 |
| Extraction Chamber Volume | 65 mL |
| Receiver Flask Capacity | 40–110 mL |
| Temperature Range | 0–285 °C |
| Temperature Control Accuracy | ±1% |
| Throughput | 6 or 12 samples per batch |
| Solvent Recovery Efficiency | up to 80% |
| Safety Features | Automatic solvent leak detection, auto-empty alert for recovery tank, self-diagnostic startup sequence |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Soxtec™ 255 |
| Extraction Chamber Volume | 30 mL |
| Receiver Flask Volume | 70–90 mL |
| Temperature Range | 0–285 °C |
| Temperature Control Accuracy | ±1% |
| Throughput | 6 samples per batch |
| Solvent Consumption per Sample | ~16 mL |
| Solvent Recovery Rate | up to 80% |
| Heating Time (20 °C → 280 °C) | 7–9 min |
| Typical Extraction Duration | 40–60 min |
| Repeatability | ±1% RSD |
| Sample Mass Range | 0.5–15 g |
| Sample Cup Dimensions | 33 × 80 mm (approx. 65 mL capacity) |
| Measurement Range | 0.1–100% fat content |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | EV6 AII14 / EV6 AII16 |
| Max. Heating Temperature | 425 °C |
| Heating Block Positions | 4 / 6 |
| Flask Capacity | 250–500 mL |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power Consumption | 1800 W / 2700 W |
| Dimensions (W×D×H) | 600×225×650 mm / 900×225×650 mm |
| Weight | 10 kg / 14 kg |
| Compliance | ASTM D2230, ISO 6496, AOAC 920.39, USP <467> |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Product Type | Imported Laboratory Instrument |
| Model | HT6+SOX416 |
| Extraction Chamber Volume | 150 mL |
| Receiver Flask Volume | 200 mL |
| Temperature Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Number of Parallel Channels | 6 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | HYDROTHERM HT6 |
| Extraction Chamber Volume | 1 L |
| Receiving Flask Volume | 1 L |
| Temperature Range | Ambient to 120 °C (typical for acid hydrolysis) |
| Temperature Control Accuracy | ±1 °C |
| Throughput | 6 samples per run (3 dual-position modules) |
| Compliance | Designed for ISO 1444–1, AOAC 991.36, and USP <467> compliant workflows |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | SOXTHERM |
| Extraction Chamber Volume | 200 mL |
| Receiver Flask Volume | 100 mL or 150 mL |
| Temperature Range | up to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Channel Configurations | 2, 4, 6, or modular up to 24 parallel units |
| Brand | Guangzhou Jingying |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | VF600 |
| Price Range | USD 4,200 – 11,200 (FOB) |
| Number of Channels | 6 |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 100 W |
| Ultimate Vacuum | 100 kPa |
| Air Flow Rate | ≥600 mL/min |
| Operating Mode | Continuous |
| Filtrate Discharge | Direct discharge into waste container |
| Filter Head Configuration | 6 single-row filter heads |
| Disposable Filtration Cup Assembly | 500 mL capacity with fast-flow membrane |
| Noise Level | ≤60 dB(A) under load |
| Net Weight | 11 kg |
| Dimensions (L×W×H) | 56.0 × 20.5 × 20.0 cm |