| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | 110WX |
| Instrument Type | Portable Weather Station |
| Enclosure Rating | IPX6 |
| Communication Protocols | NMEA 0183 (RS232/RS422) and NMEA 2000 (CAN Bus) |
| Optional Sensor | Integrated Relative Humidity (RH) Module |
| Wind Measurement Principle | Ultrasonic Time-of-Flight |
| Temperature Range | –40 °C to +70 °C (operational) |
| Pressure Accuracy | ±0.5 hPa |
| Wind Speed Range | 0–60 m/s |
| Wind Direction Range | 0–360° |
| Humidity Range (optional) | 0–100% RH, ±3% RH accuracy |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | 110WXS |
| Type | Portable Weather Station |
| Measurement Principle | Ultrasonic Wind Sensing, Capacitive Humidity & Thermistor Temperature Sensing, Piezoresistive Barometric Pressure Sensing |
| Communication Interface | RS-232 or RS-422 |
| Compliance | IP66 Enclosure Rating, NEMA 4X Equivalent |
| Operating Temperature Range | –40 °C to +70 °C |
| Power Supply | 9–36 V DC |
| Dimensions | 24.1 × 15.2 × 12.7 cm (L×W×H) |
| Weight | 1.8 kg |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | 120WX |
| Instrument Type | Portable Weather Station |
| Output Interfaces | RS232 / RS422 (NMEA 0183) / CAN Bus (NMEA 2000) |
| Environmental Rating | IPX6 (IPX4 with optional humidity sensor) |
| Power Supply | 12–24 VDC |
| Wind Measurement Principle | Ultrasonic Time-of-Flight |
| Optional Sensors | Relative Humidity, Heater |
| Compliance | NMEA 0183 v4.10, NMEA 2000 v2.00, ISO 8573-1 (compressed air quality reference for internal electronics cooling), RoHS III compliant |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | 120WXH |
| Instrument Type | Portable Weather Station |
| Enclosure Rating | IPX6 |
| Communication Interface | NMEA 0183 (RS-422 or RS-232) |
| Heating Function | Integrated thermostatically controlled heater |
| Measurement Principle | Ultrasonic time-of-flight for wind speed & direction |
| Output Parameters | True/Relative wind speed & direction, atmospheric pressure, air temperature, wind chill |
| Discontinued Status | Yes (replaced by 220WXH) |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | 150WX |
| Instrument Type | Portable Weather Station |
| Output Interfaces | RS232, RS422 (NMEA 0183), CAN Bus (NMEA 2000) |
| Environmental Rating | IPX6 (IPX4 with humidity sensor installed) |
| Power Supply | 9–40 VDC |
| Integrated Sensors | Ultrasonic wind (speed/direction), 10 Hz GPS, solid-state compass, 3-axis accelerometer, barometric pressure, air temperature, optional replaceable relative humidity sensor |
| Wind Data Output | True wind, apparent wind, gust statistics (raw 10 Hz wind samples) |
| Mounting | 1"-14 UNS or ½" NPT thread |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | 150WXRS |
| Instrument Type | Portable Weather Station |
| Communication Interface | RS232 / RS422 |
| GPS Update Rate | 10 Hz |
| Rain Measurement Principle | Acoustic Impact Detection |
| Wind Measurement Method | Ultrasonic Anemometry |
| Compass Accuracy | <1° (dynamic stabilization) |
| Enclosure Rating | IP66 |
| Operating Temperature Range | –25°C to +70°C |
| Power Supply | 9–36 VDC |
| Dimensions | 248 mm H × 140 mm D |
| Weight | 1.36 kg |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | 150WXS |
| Instrument Type | Portable Weather Station |
| Output Interface | RS232 / RS422 |
| GPS Update Rate | 10 Hz |
| Compass Accuracy | <1° |
| Enclosure Rating | IP66 |
| Operating Temperature Range | -30°C to +70°C |
| Wind Measurement Principle | Ultrasonic Time-of-Flight |
| Temperature & Humidity Shield | Integrated Solar Radiation Shield |
| Data Output Frequency | Up to 4 Hz for meteorological parameters |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | 200WX |
| Instrument Type | Portable Weather Station |
| Enclosure Rating | IPX6 |
| Output Protocols | NMEA 0183 (RS422/RS232) and NMEA 2000® (CAN Bus) |
| Integrated Sensors | Ultrasonic Wind (True & Apparent), 10 Hz GPS, 3-Axis Solid-State Compass, 3-Axis Rate Gyro, Tilt Sensor, Air Temperature, Barometric Pressure |
| Optional Sensor | Relative Humidity (Field-Replaceable) |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | 200WX-IPX7 |
| Instrument Type | Portable Weather Station |
| IP Rating | IPX7 |
| Output Protocols | NMEA 0183 (RS422/RS232) & NMEA 2000® (CAN bus) |
| GPS Update Rate | 10 Hz |
| Compass Accuracy | <1° (dynamic stabilization) |
| Wind Measurement Principle | Ultrasonic anemometry (no moving parts) |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | 220WX |
| Instrument Type | Portable Weather Station |
| Output Interfaces | RS232 / RS422 / CAN Bus |
| Communication Protocols | NMEA 0183 & NMEA 2000 |
| IP Rating | IPX6 |
| Power Supply | 9–40 VDC |
| Integrated Sensors | Ultrasonic Wind (Speed & Direction), Solid-State Compass, 10 Hz GPS, 3-Axis Accelerometer, 3-Axis Gyroscope, Barometric Pressure, Relative Humidity (Field-Replaceable), Air Temperature, Wind Chill |
| Optional | Heater Module |
| Mounting | 1"-14 UNS or ½" NPT |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | 220WXH |
| Instrument Type | Portable Weather Station |
| Enclosure Rating | IPX6 |
| Wind Measurement Principle | Ultrasonic Anemometry |
| GPS Update Rate | 10 Hz |
| Heading Accuracy | <1° (dynamic stabilized) |
| Power | 12–36 VDC |
| Output Protocols | NMEA 0183 (RS422/RS232) |
| Heating System | Integrated thermostatically controlled heater |
| Operating Temperature Range (heated) | –30°C to +55°C |
| Dimensions | 203 × 127 mm (diameter × height) |
| Weight | 1.36 kg |
| Key | Brand: Baineng |
|---|---|
| Model | N-SPC-25W |
| Rated Power | 25 W |
| Nominal Voltage | 18 V (for 12 V battery systems) |
| Peak Voltage (Vmp) | 17.9 V |
| Peak Current (Imp) | 1.4 A |
| Open-Circuit Voltage (Voc) | 22.41 V |
| Short-Circuit Current (Isc) | 1.54 A |
| Dimensions | 350 × 540 × 16 mm |
| Weight | 2 kg |
| Cell Type | Monocrystalline Silicon |
| Encapsulation | Tempered Glass + Aluminum Frame, IP65-rated waterproof lamination |
| Output Connector | DC 5.5×2.1 mm male plug |
| Cable Length | 2 m |
| Junction Box | Standard non-diode, lead-wire-free design |
| STC Conditions | 1000 W/m², AM1.5, 25 °C |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CS320 |
| Sensor Type | Thermopile-based Total Solar Radiation Sensor |
| Calibration Uncertainty | ±5% |
| Measurement Range | 0–2000 W/m² |
| Repeatability | <1% |
| Long-term Drift | <2% per year |
| Non-linearity | <1% |
| Spectral Range | 385–2105 nm |
| Field of View | 180° (hemispherical) |
| Response Time | 2 s |
| Temperature Dependence | <5% over −15 to +45 °C |
| Operating Temperature | −50 to +50 °C |
| Heating Power | 0.2 W |
| Supply Voltage | 6–24 VDC |
| Current Consumption | 5 mA (during measurement) |
| Output Protocol | SDI-12 digital interface |
| Sensor Diameter | 34.3 mm |
| Height | 39.6 mm |
| Mass | 64.9 g |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CSAT3 |
| Measurement Principle | Ultrasonic Time-of-Flight (TOF) in Three Orthogonal Axes |
| Vertical Path Length | 10 cm |
| Output Frequency | Up to 50 Hz |
| Output Options | Analog (±5 V) and Digital (SDM, RS-232) |
| Operating Temperature Range | –30°C to +50°C |
| Ingress Protection | IP66-rated enclosure |
| Compliance | Designed for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols |
| Integrated Clock | Internal temperature-compensated crystal oscillator (TCXO), ±1 ppm stability over operating range |
| Synchronization | SDM-compatible for precise multi-sensor timing alignment |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | ENERCO 400 |
| Type | Portable Weather Station |
| Certification | Compliant with WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8) |
| Power Supply | Integrated solar panel + rechargeable battery (5 V, <1 mA standby current) |
| Data Interface | RS-232 serial output |
| Environmental Rating | IP65 enclosure (ventilated, waterproof, humidity-resistant) |
| Operating Altitude | Up to 5,000 m ASL |
| Operating Temperature Range | −40 °C to +60 °C |
| Sensor Mounting | Modular hollow-arm assembly with plug-in, electrically isolated sensor interfaces |
| Data Logging Interval | Configurable from 5 s (temperature, wind) to 60 s (barometric pressure, water level) |
| Battery Autonomy | ≥30 days without solar charging |
| Compliance | Designed for GLP-aligned environmental monitoring |
| Brand | Cloudscape |
|---|---|
| Model | TH-CQX7 |
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | All-in-One Ultrasonic Weather Station |
| Measurement Range | Wind Speed: 0–60 m/s |
| Accuracy | Wind Speed ±0.1 m/s + 0.01V, Wind Direction ±2°, Temp ±0.3°C (at 25°C), RH ±3% RH (20–80% RH), Pressure ±0.25%, Illuminance <±3%, Optical Rain Rate ≤±4% |
| Resolution | Wind Speed 0.01 m/s, Wind Direction 1°, Temp 0.01°C, RH 0.01% RH, Pressure 0.1 hPa, Illuminance 1 lux, Rain Rate 0.01 mm/min |
| Communication | Standard GPRS |
| Power Supply | 8–16 V DC input |
| Enclosure Material | Imported ASA polymer |
| IP Rating | IP65+ |
| Mounting | 2 m carbon steel mast, direct-sleeve sensor integration (no flange required) |
| Data Output | RS485 Modbus RTU & JSON over serial |
| Compliance | ISO 9001, ISO 14001, ISO 45001 certified manufacturer |
| Software | PC desktop client (serial/Modbus/JSON), Android app (Bluetooth/background operation), cloud platform (CS architecture, HJ-212, HTTP/TCP forwarding, map view, alarm thresholds, scriptable data post-processing) |
| Brand | Cloudscape |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TH-FB01 |
| Instrument Type | Integrated Intrinsically Safe Weather Station |
| Wind Speed Range | 0–60 m/s |
| Wind Speed Accuracy | ±0.1 m/s + 0.01V |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±2° |
| Air Temperature Range | −40 to +80 °C |
| Temp Accuracy | ±0.3 °C @ 25 °C |
| Humidity Range | 0–100 %RH |
| RH Accuracy | ±3 %RH (20–80 %RH) |
| Atmospheric Pressure Range | 300–1100 hPa |
| Pressure Accuracy | ±0.25 %FS |
| Data Storage Capacity | ≥500,000 records |
| Power Consumption | 1.75 W |
| Enclosure Rating | IP66/IP67 equivalent (per GB3836 compliance) |
| Certification | Ex ia IIC T6 Ga (GB3836.1-2010 & GB3836.4-2010) |
| Communication | RS-485 Modbus RTU |
| Software Compliance | Supports audit trail, configurable data logging intervals, and user-defined parameter mapping |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vantage Pro 2 |
| Instrument Type | Portable Weather Station |
| Wind Speed Range | 1–67 m/s, Accuracy: ±5% |
| Barometric Pressure Range | 880–1080 hPa, Accuracy: ±1.0 hPa, Resolution: 0.1 hPa |
| Wind Direction Range | 0–360°, Accuracy: ±7°, Resolution: 1° |
| Air Temperature Range | −40 to +65 °C, Accuracy: ±0.5 °C, Resolution: 0.1 °C |
| Relative Humidity Range | 0–100%, Accuracy: ±3%, Resolution: 1% |
| Rainfall Range (Daily) | 0–9999 mm, Accuracy: ±4%, Resolution: 0.2 mm |
| Solar Radiation Range | 0–1800 W/m², Spectral Response: 300–1100 nm, Accuracy: ±5%, Resolution: 1 W/m² |
| UV Radiation Range | 0–199 MEDs, Spectral Response: 290–390 nm, Accuracy: ±5%, Resolution: 0.1 MEDs |
| Soil Temperature Range | −40 to +65 °C, Accuracy: ±0.5 °C, Resolution: 1 °C |
| Leaf Wetness Range | 0–15 units, Accuracy: ±0.5, Resolution: 1 unit |
| Soil Moisture Range | 0–200 cb, Resolution: 1 cb |
| Dew Point Range | −76 to +54 °C, Accuracy: ±1.5 °C, Resolution: 1 °C |
| ET Calculation | Daily/Monthly/Annual, Resolution: 0.1 mm, Accuracy: ±5% |
| Operating Temperature (Console) | −40 to +70 °C |
| Memory Capacity | 128 KB non-volatile |
| Sampling Intervals | 1, 5, 10, 15, 30, 60, or 120 minutes |
| Wireless Transmission Range | Up to 300 m (line-of-sight), typical 60–120 m (obstructed) |
| Brand | Davis (USA) |
|---|---|
| Origin | USA |
| Model | Vantage Pro2 6152 |
| Type | Portable Wireless Weather Station |
| Power | Solar + CR-123A Li battery (8-month backup) / AC adapter |
| Data Logging | Flash memory (non-volatile) |
| Wireless Range | Up to 165 m (line-of-sight) |
| Operating Temp | –40°C to +65°C |
| Compliance | FCC Part 15, IC RSS-210, RoHS |
| Brand | Davis (USA) |
|---|---|
| Origin | USA |
| Model | Vantage Pro2 6152C |
| Instrument Type | Wired Integrated Weather Station |
| Power Consumption | ≤10 mA (ISS + Console, 4–6 VDC) |
| Max Cable Length | 300 m (Console), 165 m (ISS) |
| Operating Temperature | −40°C to +65°C (ISS), 0°C to +60°C (Console) |
| Wind Speed Range | 0–89 m/s |
| Wind Direction | 1–360° (±3° accuracy) |
| Temp Range (Outdoor) | −40°C to +65°C (±0.3°C) |
| Humidity | 1–100% RH (±2% accuracy) |
| Barometric Pressure | 540–1100 hPa (±1.0 hPa) |
| Rainfall Resolution | 0.2 mm (≤2000 mm), 1 mm (>2000 mm) |
| Rainfall Accuracy | ±3% or ±0.2 mm (whichever greater, ≤250 mm/h) |
| Data Logging | Flash memory (non-volatile) |
| Communication | RJ-11 wired interface |
| Compliance | Designed for NOAA-compliant reporting, GLP-aligned data integrity |
| Brand | Davis (USA) |
|---|---|
| Origin | USA |
| Model | Vantage Pro2 6153 |
| Instrument Type | Portable Weather Station |
| Certification | CE, FCC, RoHS Compliant |
| Data Logging Interval | 1–60 min (user-configurable) |
| Wireless Transmission Range | Up to 300 m (line-of-sight) |
| Power Supply | Solar panel (0.5 W standard / 0.75 W with fan) + CR-123A lithium or NiMH C-cell batteries |
| Operating Temperature | −40 °C to +65 °C |
| Enclosure Material | UV-stabilized ABS and polypropylene |
| Sensor Housing Ventilation | Integrated brushless DC fan (active airflow ≥2.5 m/s in full sun) |
| Brand | Davis Instruments (USA) |
|---|---|
| Origin | USA |
| Model | Vantage Pro2 Plus 6162 |
| Type | Portable Wireless Weather Station |
| Power Supply | Solar panel (0.5 W) + CR-123A lithium batteries (2 × 3 V) or NiMH C-cell backup |
| Operating Temperature | –40 °C to +65 °C |
| Wireless Transmission Range | Up to 165 m (line-of-sight) |
| Data Logging Interval | 1–60 min configurable |
| Compliance | FCC Part 15, IC RSS-210, RoHS |
| Brand | Davis Instruments |
|---|---|
| Origin | USA |
| Model | Vantage Pro2 Plus 6162C |
| Type | Wired Integrated Weather Station |
| Power | 4–6 VDC, avg. 10 mA (ISS + Console) |
| Operating Temp | –40 to +65 °C (ISS), 0 to +60 °C (Console) |
| Max Cable Length | 300 m (Console), 165 m (ISS) |
| Data Storage | Non-volatile Flash Memory |
| Compliance | NOAA-compatible reporting, ASTM D5096 (radiation), ISO 24798 (wind sensor mounting), IEC 61000-4-5 (surge immunity) |
| Brand | Davis (USA) |
|---|---|
| Origin | USA |
| Model | Vantage Pro2 Plus 6163 |
| Instrument Type | Portable Weather Station |
| Housing Material | UV-Stabilized ABS & Polypropylene |
| Operating Temperature | −40 °C to +65 °C (ISS), 0 °C to +60 °C (Console) |
| Power | Solar Panel (0.5 W standard, 0.75 W with fan) + CR-123A Li‑battery (2 × 3 V) or Ni‑MH C-cells |
| Avg. Current Draw | ≤10 mA (ISS), ≤0.9 mA (Console) |
| Wireless Range | Up to 300 m (line-of-sight), extendable to 1 km with repeater |
| Data Logging Interval | 1–60 min user-selectable |
| Memory | Non-volatile Flash (retains data during power loss) |
| Compliance | FCC Part 15, IC RSS-210, RoHS |
| Brand | Davis |
|---|---|
| Origin | USA |
| Model | Vantage Vue 6250 |
| Instrument Type | Portable Weather Station |
| Wireless Transmission Range | 300 m |
| Data Update Interval | 2.5–24 s (sensor-dependent) |
| Operating Temperature (ISS) | -40 to +65 °C |
| Power Source | Solar panel (0.5 W) + CR123A lithium battery (8-month backup) |
| Compliance | WMO observational standards |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | Dynamet |
| Sensor Core | Gill MaxiMet™ 500 (Dynamet 2 & 5) / MaxiMet™ 600 (Dynamet 6) |
| Wind Measurement | Ultrasonic |
| Data Capacity | 100,000 records |
| ETP Calculation | Penman–Van Bavel (PENV) algorithm |
| Communication | Optional 2G/3G DTU or VPN-based cellular transmission |
| Compliance | ASTM D5098, ISO 17025-aligned sensor validation protocols, WMO Guide to Instruments and Methods of Observation (CIMO) reference-class deployment |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | InteliMet Advantage |
| Sensor Compatibility | GMX500/GMX600 Integrated Meteorological Sensors |
| Power Supply | 10 W Solar Panel with Battery Backup |
| Communication Options | Wired USB/RS-485 or Optional 2G/3G DTU/VPN Cellular Module |
| Environmental Rating | IP66 |
| EMC Compliance | BS EN 61326:2013, FCC CFR 47 Part 15.109 |
| Operating Temperature Range | -40 °C to +70 °C |
| Wind Speed Range | 0.1–60 m/s (±3% @ 0–40 m/s |
| Wind Direction Range | 0–359° (±3° @ 0–40 m/s |
| Atmospheric Pressure Range | 300–1100 hPa (±0.5 hPa @ 25 °C) |
| Air Temperature Range | -40–70 °C (±0.3 °C @ 20 °C) |
| Relative Humidity Range | 0–100 %RH (±2 %RH @ 10–90 %RH, 20 °C) |
| Dew Point Accuracy | ±0.3 °C @ 20 °C |
| Rainfall Measurement (InteliMet Advantage 5) | Tipping Bucket (UV-stabilized ABS |
| Rainfall Measurement (InteliMet Advantage 6) | Optical Sensor (0–150 mm/hr |
| Solar Radiation Spectral Range | 380–1120 nm (±5% absolute accuracy) |
| Data Processing | ETP calculation per Lascano & Van Bavel (ASA, 2006) |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SapIP-MICRO |
| Instrument Type | Wireless Mesh-Based Environmental Monitoring System |
| Data Transmission | LoRaWAN / Cellular (SPIP-CELL optional) |
| Network Topology | Self-Healing Mesh |
| Max Nodes per Network | 25 |
| Inter-Node Range | 300–500 m (line-of-sight, SPIP-24K radio) |
| Operating Temperature | −40 to +70 °C |
| Relative Humidity Range | 0–100 % RH |
| Accuracy | ±3 % RH (0–90 % RH, 20 °C), ±5 % RH (90–100 % RH) |
| Air Temperature Range | −40 to +60 °C |
| Accuracy | ±0.6 °C |
| Solar Radiation Range | 0–2000 W/m² |
| Spectral Response | 360–1120 nm |
| Absolute Accuracy | ±5 % |
| Rainfall Resolution | 0.25 mm |
| Accuracy | ±4 % or ±1 tip (0.2–50.0 mm/hr) |
| Wind Speed Range | 0–50 m/s |
| Accuracy | ±0.5 m/s |
| Wind Direction Range | 0–360° |
| Accuracy | ±5° |
| Onboard Memory | 30,000 records |
| Power | 7 Ah rechargeable battery + 10 W solar panel |
| Input Channels | 8 differential analog inputs |
| ETP Calculation | FAO-56 Penman-Monteith supported in firmware |
| Brand | Campbell |
|---|---|
| Origin | USA |
| Model | EC150 |
| Measurement Principle | Open-path infrared absorption (CO₂/H₂O) + ultrasonic anemometry (3D wind, sonic temperature) |
| Output Frequency | Up to 60 Hz |
| Bandwidth | 20 Hz |
| Power Consumption | Low-power design suitable for solar-powered operation |
| Environmental Rating | Outdoor-rated, rain-resistant housing with hydrophobic mesh and angled optical windows |
| Calibration | Factory-calibrated for CO₂, H₂O, air temperature, barometric pressure, and sonic temperature across wide operational ranges |
| Compatibility | Native integration with Campbell Scientific dataloggers (CR6, CR1000X, etc.) for configuration, zero/span adjustment, diagnostics, and real-time data streaming |
| Diagnostic Capabilities | Comprehensive internal diagnostics including signal strength, window contamination index, path alignment status, and transducer health monitoring |
| Compliance | Designed to meet field requirements for FLUXNET, AmeriFlux, ICOS, and other long-term eddy covariance networks adhering to AmeriFlux/ICOS Best Practices and ISO 17025 traceable calibration protocols |
| Brand | EMS |
|---|---|
| Origin | Czech Republic |
| Type | Portable Weather Station |
| Data Logger | Modular RailBox RB System (16-channel standard, up to 64-channel expandable) |
| Power Supply | Solar panel + rechargeable battery (6.5–15 VDC, standby <1 mA) |
| Communication | GPRS/LAN/4G (backward-compatible with EDGE/GPRS) |
| GPS | Integrated geolocation tagging |
| Internal Memory | 220,000 timestamped records (expandable to 450,000) |
| MicroSD Storage | 8 GB (2–3 years of continuous logging) |
| Operating Temperature | −40 °C to +60 °C |
| Compliance | DIN rail mounting, SDI-12 & analog sensor support, IP67-rated enclosures for field deployment |