| Brand | Ability Technology |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PPA-1200 |
| Detection Elements | As, Sb, Pb, Sn, Hg, Se, Bi, Te, Ge in aqueous environmental matrices |
| Detection Limits | Sb ≤ 0.3 ppb, Hg ≤ 0.03 ppb |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-6400 |
| Target Analytes | Thallium (Tl), Lithium (Li) |
| Response Time | ≤2 min |
| Power Supply | Integrated Rechargeable Li-ion Battery (≥12 h continuous operation) |
| Operating Pressure | Ambient Atmospheric Pressure |
| Sample Introduction | Direct Liquid Injection (No Pretreatment Required) |
| Data Storage Capacity | >2000 Records with Real-time Spectral Display |
| Connectivity | USB for Data Export & Firmware Update |
| Compliance | Designed for Field Deployment under ISO/IEC 17025-aligned QA/QC Practices |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-6400A |
| Detection Target | Thallium (Tl) in aqueous samples |
| Response Time | ≤2 min |
| Power Supply | Integrated rechargeable lithium battery (≥12 h continuous operation) |
| Data Storage | >2000 measurement records with real-time spectral display |
| Interface | Touchscreen GUI, USB for data export & firmware update |
| Operating Environment | Ambient atmospheric pressure, no external gas supply or AC power required |
| Sample Handling | Direct liquid injection, no pretreatment |
| Calibration | Built-in standard curves + on-site curve generation capability |
| Remote Diagnostics | Supported |
| Brand | EXPEC / Spectral Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EXPEC 1920 |
| Pricing | Upon Request |
| Brand | CASP |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GA2202 |
| Detection Gases | Methane (CH₄), Ethane (C₂H₆) |
| Detection Principle | Mid-Infrared Absorption + Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Response Time | <1 s |
| Measurement Speed | Up to 60 km/h mobile survey |
| Dual-Gas Simultaneous Quantification | Yes |
| Operating Temperature Control | Active Thermostatic Stabilization |
| Measurement Range | Wide-range configurable for urban ambient monitoring, station boundary monitoring, and landfill/anaerobic digester plume tracking |
| Data Security & Support | Fully domestic R&D and manufacturing, local service network |
| Brand | Ability Technology |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PPA-6100 |
| Target Analytes | Thallium (Tl), Cadmium (Cd), Silver (Ag), Zinc (Zn) in environmental water matrices |
| Detection Limit | Tl ≤ 0.005 ppb |
| Analysis Time | < 120 s per sample |
| Power Consumption | Low |
| Form Factor | Compact, Portable, Vehicle-Mountable |
| Gas Consumption | Low |
| Interference Resistance | High |
| Positioning | Integrated High-Precision GNSS Module (enables future online monitoring integration) |
| Brand | Graywolf |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | AdvancedSense XM |
| Detection Medium | Gases |
| Detectable Parameters | TVOC, HCHO, CO₂, SO₂, O₃, NO₂, O₂, NO, NH₃, CO, Cl₂, H₂S, H₂, HCN, F₂, HCl, PH₃, HF, AsH₃, C₂H₄O, SiH₄, ClO₂, COCl₂, B₂H₆ (20+ gases selectable) |
| Particle Measurement | PM₂.₅, PM₁₀, TSP (0.3–25 µm, 6-channel configurable) |
| Meteorological Parameters | Air velocity (hot-wire & pitot tube), volumetric flow (m³/min), static/differential pressure, temperature (ambient, surface, liquid, thermocouple), relative/humid/absolute/specific/wet-bulb humidity |
| Brand | Graywolf |
|---|---|
| Model | DSII-5 |
| Origin | Beijing, China |
| Distribution Status | Authorized Distributor |
| Detection Targets | TVOC, HCHO, NH₃, CO, CO₂, Temperature, Relative Humidity, and >20 Gaseous Parameters |
| Response Time (90%) | <1 min |
| Units | mg/m³, µg/m³, ppm, ppb, % |
| Operating System | Wolf OS |
| Data Logging | Real-time & Long-term Continuous Monitoring |
| Probe Interchangeability | Hot-swappable modular sensor architecture |
| Display Annotation | Text, voice, image tagging during measurement |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Hapline M8800 |
| Detection Target | Volatile Organic Compounds (VOCs) |
| Detection Mode | Dual-Mode (Real-Time Single-Quadrupole MS + Stationary GC-MS Quantification) |
| Weight | <40 kg |
| Vacuum System | Non-Mechanical (Turbomolecular + Ion Pump Hybrid) |
| Operating Interface | Detachable Touchscreen Control Panel (Local & Remote Operation Supported) |
| Data Transmission | Cloud-Integrated Platform with Real-Time Telemetry |
| Compliance | Designed to Support ASTM D6348, EPA TO-15/TO-17, and GB 50325–2020 Method Requirements |
| Brand | Hexin Mass Spectrometry |
|---|---|
| Origin | Guangdong, China |
| Model | ICP-MS 1000 |
| Configuration | Vehicle-mounted integrated system with ICP-MS, sampling toolkit, power & gas supply units, communication module, and environmental control subsystem |
| Vacuum System | Dual turbo-molecular pumps (cold-start time ≈ 30 min) |
| Sample throughput | ~3–5 min per sample (post-preparation) |
| Power Supply | Dual-mode (AC grid + imported industrial-grade generator) |
| Vibration isolation | Full-vehicle active/passive damping architecture |
| Air purification | Onboard catalytic filtration compliant with GB/T 18883–2022 indoor air quality standards |
| Regulatory alignment | Designed to support EPA Method 200.8, ISO 17294-2:2016, and China HJ 680–2013 workflows |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZR-3110C |
| Detection Target | VOCs (Volatile Organic Compounds) |
| Sensor Technologies | Electrochemical (EC), Catalytic Bead (LEL), Photoionization Detection (PID) |
| Compliance Standards | GB 12358–2006, HJ 872–2017, GBZ 2.1–2019, GB/T 36198–2018, JJF 1172–2007, JJG 915–2008, JJG 635–2011, JJG 551–2003, JJG 695–2003, JJG 693–2011, Q/0214 ZRB008–2017 |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | ZR-7600 |
| Detection Medium | Gaseous |
| Detection Capability | Multi-gas |
| Response Time | < 30 seconds (typical for electrochemical & PID sensors) |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 9100FIRair Emergency Edition |
| Price Range | USD 125,000 – 182,000 |
| Analyte Types | Gaseous, Aqueous, Solid (soil headspace/vapor) |
| Target Analytes | VOCs, inorganic gases (e.g., CO, CO₂, NO, NO₂, SO₂, NH₃, HCl, HF, CH₄), greenhouse gases |
| Response Time | ≤120 s (gas-dependent) |
| Spectral Resolution Options | 1 cm⁻¹ or 4 cm⁻¹ |
| Detector | Room-temperature DTGS |
| Light Source | VCSEL-based reference laser (10-year lifetime) |
| Built-in Sample Conditioning | Particulate filtration, N₂ purge ports (optical path & gas cell), optional integrated zirconia O₂ sensor |
| Optional Module | External H₂S electrochemical module |
| Compliance | HJ 919–2017, HJ 920–2017, HJ 1011–2018 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-ZFB05 |
| Pricing | Available Upon Request |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600Plus |
| Origin | Shandong, China |
| Detection Targets | ODS (CFCs, HCFCs, Halons, Methyl Bromide), VOCs, SVOCs |
| Sample Matrices | Ambient Air, Water (via Headspace), Soil (via Purge-and-Trap or Thermal Desorption), Refrigerant Gases |
| Compliance | GB/T 32210–2015, HJ 11223–2021, HJ 1227–2021, HJ 1058–2019 |
| Detection Principle | Capillary GC separation coupled with linear ion trap MS detection |
| Ionization Mode | Electron Ionization (EI), inertized high-temperature source (up to 300 °C) |
| Preconcentration | Integrated cryogenic trapping (down to 0 °C) |
| Mass Analyzer | Dual-curved linear ion trap |
| Dynamic Range | 7 orders of magnitude |
| Internal Standard Delivery | Automated, inertized, programmable syringe-based introduction |
| Brand | OSEN |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | OSEN-6C-16 |
| Detection Targets | Particulate Matter (PM₂.₅, PM₁₀) |
| Response Time | ≤30 s |
| Power Supply | Integrated Rechargeable Lithium Battery |
| Display | TFT LCD Touchscreen Interface |
| Data Storage | Onboard High-Capacity Flash Memory |
| Connectivity | GPRS Module for Real-Time Telemetry |
| Positioning | Dual-Mode GPS + BeiDou GNSS Receiver |
| Environmental Rating | IP54 (Dust-Resistant, Splash-Protected) |
| Compliance | Meets GB/T 31947–2015 (Chinese National Standard for Portable PM Monitors), Supports ISO 12103-1 Reference Dust Calibration Protocols |
| Brand | OSEN |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OSEN-JQG-03 |
| Price | USD 8,400 (Reference FOB Guangdong |
| Brand | BANFF |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | BANFF Biotechnology |
| Type | Domestic |
| Model | QitVenture1 Sail |
| Detection Targets | Ambient Air & Water (VOCs) |
| Detection Method | Membrane Inlet Mass Spectrometry (MIMS) + Integrated GC-MS Confirmation |
| LOD | <0.1 ppb (for selected VOCs) |
| Compliance | Meets 2019 “Technical Specification for Mobile VOCs Monitoring in the Yangtze River Delta Eco-Green Integrated Development Demonstration Zone” |
| Mounting | Vehicle-integrated mobile platform |
| Application Scope | Real-time emission source identification, emergency response, boundary monitoring, and ambient air quality assessment |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHBX6001 |
| Detection Target | Gaseous CO |
| Response Time | ≤100 s |
| Measurement Principle | Electrochemical Sensing |
| Environmental Compensation | Integrated Temperature & Atmospheric Pressure Sensors |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHBX6002 |
| Detection Target | Gaseous O₃ |
| Response Time | ≤100 s |
| Measurement Principle | Electrochemical Sensing |
| Environmental Compensation | Integrated Temperature & Atmospheric Pressure Sensors |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XHBX6003 |
| Detection Target | Gaseous Pollutants |
| Measured Parameters | NO, NO₂, NOₓ |
| Response Time | ≤100 s |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | XHBX6004 |
| Detection Target | Gaseous Analytes |
| Measured Parameters | SO₂, CO |
| Response Time | ≤120 s |
| Environmental Sensors Integrated | Ambient Temperature, Atmospheric Pressure |
| Compliance Basis | GB/T 15439–1995, HJ 693–2014, HJ 973–2018 |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH-9007 |
| Detection Parameters | COD (high/low range), Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Heavy Metals (Cr⁶⁺, Cr-total, Zn, Ni, Fe, Cu, Mn, Al, Ag, Cd, CN⁻, S²⁻), Free Chlorine, Total Chlorine, ClO₂, Formaldehyde, Turbidity, Color, SO₄²⁻, NO₃⁻-N, Anionic Surfactants, Volatile Phenols, O₃, Fluoride, KMnO₄ Index, pH, Dissolved Oxygen, Conductivity, Temperature |
| Wavelength Range | 400–860 nm |
| Measurement Repeatability | ≤ ±5% |
| Accuracy | ≤ ±5% |
| Display | 5-inch IPS Touchscreen |
| Dimensions | 247 × 105 × 59 mm |
| IP Rating | IP43 |
| Battery | Built-in Li-ion, Type-C Charging |
| Data Storage | 16 GB MicroSD (≥10 years of typical field data) |
| Preloaded Calibration Curves | 100 fixed + user-definable slots |
| Response Time | ≤10 seconds per parameter |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VOCs-800P |
| Detection Target | NMHC (Non-Methane Hydrocarbons) |
| Detection Limit | ≤0.07 mg/m³ |
| Response Time | ≤60 s |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | K55 |
| Pricing | Available Upon Request |
| Detector Resolution | 320 × 240 pixels |
| Thermal Sensitivity (NETD) | ≤30 mK |
| Display | 4-inch LCD, 320 × 240 resolution |
| Frame Rate | 60 Hz |
| Spectral Range | 7.5–13 µm |
| Temperature Range | –20 °C to +650 °C |
| Operating Temperature | –20 °C to +85 °C (15 min at +150 °C |
| IP Rating | IP67 |
| Weight | 1.1 kg (with battery) |
| Dimensions | <120 × 125 × 280 mm |
| Battery Life | 4 hours continuous operation |
| Video Format | MPEG-4 |
| Internal Storage | Up to 200 video files, total recording time up to 600 minutes, max clip length 5 minutes |
| Digital Zoom | 2× |
| Wake-up Time from Sleep Mode | <4 s |
| Startup Time | <17 s |
| Charging | Dual-bay desktop charger |