High Temperature Aging Test Chamber
Filter
Showing 1–30 of 181 results
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP-GD |
| Pricing | Upon Request |
| Max Operating Temperature | 150–200 °C |
| Brand | Blue M |
|---|---|
| Model | IGF 6680 / IGF 7780 / IGF 8880 / IGF 9980 |
| Origin | USA |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Uniformity | ±2% of setpoint |
| Stability | ±2% of setpoint |
| Accuracy | ±0.5°C |
| Resolution | ±0.1°C |
| Internal Chamber Dimensions (W×H×D) | 25×20×20 cm (IGF 7780) |
| Heating Element | Open-wire NiCr |
| Insulation | 6-inch mineral wool |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂/96% N₂) |
| Safety Features | Door interlock (heater & blower shutdown), inert gas leak detection with audible/visual alarm and heater disable, pressure monitoring, purge timer, pressure relief valve, water-cooled door (IGF 8880 & 9980) |
| Compliance | NFPA 86 Class B |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-6680 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Max Operating Temperature | 400°C |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability (Fluctuation) | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open-wire Incoloy® (NiCr) |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Features | Door interlock (heater & blower cutoff), pressure-loss alarm with automatic heater shutdown, purge timer, relief valve |
| Insulation | 6-inch mineral wool |
| Door Seal | Blue M proprietary fiberglass gasket |
| Airflow | High-capacity horizontal laminar flow system |
| Compliance | NFPA 86 Class B oven construction |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-7780 |
| Type | Inert Gas High-Temperature Aging Chamber |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Accuracy | ±0.5°C |
| Temperature Resolution | ±0.1°C |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open Heavy-Duty Nichrome Wire |
| Insulation | 6-inch Mineral Wool |
| Door Seal | Blue M Fiberglass Gasket |
| Gas Compatibility | N₂, Ar, He, CO₂, and Forming Gas (4% H₂ / 96% N₂) |
| Safety Features | Door Interlock (heater & blower cutoff), Leak Detection Alarm with Heater Shutdown, Pressure Monitoring, Purge Timer, Relief Valve |
| Cooling | Air-Cooled Door (IGF-7780) |
| Compliance | NFPA 86 Class B |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-7780 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Max Operating Temperature | 400°C |
| Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Internal Volume | 5.8 ft³ (0.164 m³) |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Certifications | NFPA 86 Class B |
| Heating System | Open-wire NiCr elements |
| Insulation | 6-inch mineral wool |
| Door Seal | High-temp fiberglass gasket |
| Cooling | Air-cooled door (IGF-7780) |
| Control Resolution | ±0.1°C |
| Exhaust | Adjustable damper with purge timer |
| Interlocks | Door switch (heater/fan shutdown), gas leak detection alarm, pressure monitoring |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-7780 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open-type NiCr wire |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Features | Door interlock, gas leak alarm with heater shutdown, purge timer, pressure monitoring, blow-down relief valve |
| Insulation | 6-inch mineral wool |
| Door Seal | High-temp fiberglass gasket |
| Cooling | Air-cooled (IGF-7780) |
| Compliance | NFPA 86 Class B oven |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-7780 / IGF-8880 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open-type NiCr wire |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Features | Door interlock shutdown, inert gas leak alarm with heater cutoff, pressure monitoring, purge timer, relief valve |
| Insulation | 6-inch mineral wool |
| Door Seal | Blue M fiberglass gasket |
| Cooling | Water-cooled door (IGF-8880 & IGF-9980 models) |
| Compliance | NFPA 86 Class B |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-8880 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open-wire Ni-Chrome |
| Inert Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Features | Door interlock (heater & blower shutdown), gas leak alarm with automatic heater cutoff, pressure monitoring, purge timer, pressure relief valve, water-cooled door (IGF-8880/9980 models) |
| Insulation | 6-inch mineral wool |
| Door Seal | Fiberglass-reinforced silicone gasket |
| Compliance | NFPA 86 Class B |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-8880 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open-type NiCr wire |
| Cooling | Water-cooled door (IGF-8880 & IGF-9980) |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Compliance | NFPA 86 Class B |
| Insulation | 6-inch mineral wool |
| Door Seal | Fiberglass-reinforced silicone gasket |
| Airflow System | High-capacity horizontal laminar flow |
| Pressure & Flow Monitoring | Integrated chamber pressure gauge and mass flow controller |
| Exhaust Interface | 3/8" NPT inlet/outlet with purge timer and relief valve |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-8880 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open-wire NiCr |
| Atmosphere Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Features | Door interlock, inert gas leak detection with heater shutdown, pressure monitoring, purge timer, pressure relief valve, water-cooled door (IGF-8880 & IGF-9980) |
| Insulation | 6-inch mineral wool |
| Door Seal | Blue M proprietary fiberglass gasket |
| Compliance | NFPA 86 Class B |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-8880 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Heating Rate | Ambient +15°C to 593°C (1099°F) |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Chamber Construction | Welded stainless steel inner chamber with inert gas compatibility |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ / 96% N₂) |
| Cooling | Water-cooled door (IGF-8880 & IGF-9980 models) |
| Safety Features | Door interlock (heater/fan shutdown), leak detection alarm with automatic heater cutoff, pressure monitoring, purge timer, relief valve |
| Insulation | 6-inch mineral wool |
| Airflow | High-capacity horizontal laminar flow system |
| Sealing | Fiberglass-reinforced silicone door gasket |
| Compliance | NFPA 86 Class B oven certification |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF7780 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open Heavy-Duty Nichrome Wire |
| Insulation | 6-inch Mineral Wool |
| Door Seal | Fiberglass Gasket |
| Gas Compatibility | N₂, Ar, CO₂, He, and Forming Gas (4% H₂ / 96% N₂) |
| Safety Features | Door-Interlocked Heater/Fan Shutdown, Leak Detection Alarm with Auto Heater Disable, Pressure Monitoring, Purge Timer, Relief Valve |
| Compliance | NFPA 86 Class B |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF7780 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Max Operating Temperature | 400°C (standard configuration, up to 593°C rated) |
| Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Internal Volume | 5.8 ft³ (0.164 m³) |
| Heating Element | Open-wire NiCr |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ / 96% N₂) |
| Safety Features | Door interlock, inert gas leak detection with heater shutdown, pressure monitoring, purge timer, relief valve |
| Insulation | 6-inch mineral wool |
| Door Seal | High-temperature fiberglass gasket |
| Cooling | Air-cooled door (IGF7780) |
| Compliance | NFPA 86 Class B |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF7780 / IGF8880 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Max Operating Temperature | 400°C (standard configuration, up to 593°C with optional upgrades) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Heating Rate | Ambient +15°C to 593°C in typical ramp profile |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Construction | Dual-wall stainless steel chamber with liquid-cooled door (IGF8880), inert gas-compatible sealed cavity |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ / 96% N₂) |
| Safety Certifications | NFPA 86 Class B compliant |
| Insulation | 6-inch mineral wool |
| Airflow | High-capacity horizontal laminar flow system |
| Control Resolution | ±0.1°C |
| Power Supply | 208–480 VAC, 3-phase, 50/60 Hz |
| Electrical Load | 15.7–30.0 kW (model-dependent) |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | LUNAIRE WSS |
| Temperature Range | −70 °C to +180 °C |
| Temperature Uniformity | ±1.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Deviation | ±1.0 °C |
| Ramp Time | Ambient to 180 °C |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Chamber Volume Options | 288 ft³, 512 ft³, 800 ft³ |
| Application Class | Air-Heating Thermal Aging Chamber |
| Compliance Context | Designed for ICH Q1A(R3), USP <1151>, FDA 21 CFR Part 11 (with optional audit trail software), and GLP/GMP environmental validation protocols |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | 8.5SVO |
| Temperature Range | Ambient +15°C to +200°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Heating Rate | ≤100 min (from ambient to max temperature) |
| Internal Chamber Dimensions (W×H×D) | 597 mm × 698 mm × 597 mm (23.5" × 27.5" × 23.5") |
| Internal Volume | 8.5 ft³ / 240 L |
| Vacuum Capability | Down to 8 Torr (mmHg) |
| Power Supply | 230 V, 3-Phase, 60 Hz |
| Rated Power | 4 kW |
| Standard Shelves | 2 adjustable stainless steel shelves |
| Construction | Dual-wall heavy-gauge steel cabinet with fiberglass insulation |
| Door | Full-view tempered glass window with high-temp silicone gasket |
| Control System | Ethernet-enabled touchscreen PID controller with data logging and profile programming |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | Asia |
| Temperature Range | -70°C to 180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Max Operating Temperature | 200°C (short-term) |
| Internal Chamber Dimensions (W×H×D) | 521 mm × 508 mm × 559 mm |
| Construction | Interior – SUS#304 stainless steel |
| Air Circulation | Forced convection |
| Humidity Capability | 20–95% RH (optional, standard range), 10–95% RH (custom range) |
| System Type | Single-stage or cascade refrigeration (for sub-zero operation) |
| Application Class | High-Temperature Aging Test Chamber, Thermal Cycling Chamber |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | Tenney Junior |
| Temperature Range | -68°C to +180°C |
| Uniformity | ±1.0°C |
| Stability | ±1.0°C |
| Deviation | ±1.0°C |
| Ramp Rate (Ambient to 200°C) | 60 min |
| Internal Volume | 1.2–64 ft³ (0.034–1.812 m³) |
| Controller | Watlow F4T with INTUITION™ Process Control |
| Compliance | CE-marked (50/60 Hz), NIST-traceable calibration available, ISO/IEC 17025-compliant calibration services offered |
| Construction | Continuously welded stainless steel interior, fiberglass insulation, hermetic seal |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | SVO |
| Temperature Range | -70°C to +180°C |
| Max Operating Temperature | +150°C (standard), up to +200°C (optional) |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Pressure Range | Ambient (760 Torr) down to 0.169 Torr (equivalent to ~200,000 ft altitude) |
| Internal Chamber Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Heating Method | Immersed electric heater with thermal fluid circulation |
| Vacuum Control | Auto-regulated solenoid valves for precise altitude simulation |
| Controller | Synergy Quattro touchscreen (320×240 color LCD), PID with auto-tuning, dual-channel capability, real-time clock, USB/RS-232/Ethernet (10/100) connectivity |
| Compliance | Designed for ASTM D573, D865, ISO 188, USP <121>, and GLP/GMP-relevant data integrity requirements (audit trail, user access control, electronic signatures via optional software modules) |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | T2 |
| Temperature Range | −70 °C to +180 °C |
| Humidity Range | 20–95 % RH (at dry-bulb 20–85 °C, dew point ≥5 °C) |
| Temperature Uniformity | ±1.0 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Deviation | ±1.0 °C |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Refrigerant | Non-CFC, environmentally compliant |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | TS2 Series Thermal Shock Test Chamber |
| Temperature Range | -70°C to +180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Ramp Rate | Ambient to +180°C (specification dependent on configuration) |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Dual-Zone Configuration | Hot Zone (+40°C to +200°C), Cold Zone (-73°C to +40°C) |
| Cooling System | Cascade refrigeration with two semi-hermetic compressors |
| Heating | Nickel-chromium wire elements with horizontal airflow |
| Insulation | Ceramic fiber + polyurethane, welded stainless steel interior liner |
| Control System | Synergy Quattro touchscreen controller (320×240 color LCD), PID with auto-tuning, dual-channel capability |
| Compliance | MIL-STD-202G Method 107G Condition F |
| Safety | Dual-limit switches, over/under-temperature protection, OTP TempGard per chamber, door interlock, stainless steel mesh baskets (200 lb capacity per zone) |
| [Brand | Blue M |
|---|---|
| Origin | USA |
| Model | TSJR |
| Temperature Range | -70°C to 180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Heating Rate | Ambient to 180°C (typical) |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Construction | Continuously welded stainless steel interior |
| Refrigeration System | Dual-stage cascade with two hermetic reciprocating compressors |
| Heating System | Open-coil nickel-chromium wire heaters with ceramic insulation |
| Control System | Synergy Quattro touchscreen controller (320×240 color LCD), PID with auto-tuning, dual-channel capability |
| Compliance | Designed to support MIL-STD-202G thermal shock test protocols] |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | TENNEY Vacuum Chamber |
| Price Range | USD 70,000 – 140,000 (FOB) |
| Max Operating Temperature | +200°C |
| Temperature Range | Ambient to +200°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Ramp-up Time | ≤100 min (ambient to +200°C) |
| Internal Chamber Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Volume Range | 2.65–226 ft³ |
| Base Pressure | ≤1×10⁻⁷ Torr (field-achievable) |
| Ultimate Vacuum (with cryo/turbo pumping) | ≤5.0×10⁻⁶ Torr in ≤4 hours |
| Thermal Range with LN₂/GN₂ Cooling | −150°C to +150°C |
| Optional Cryogenic Shield | −184°C |
| Vacuum Bake Capability | Yes |
| Construction | Electropolished 316L Stainless Steel Vessel |
| Compliance | ASME BPVC Section VIII Div. 1, OSHA 1910.146, NEC Article 500/505 |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | WSP |
| Temperature Range | -70°C to 180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Heating Rate | Ambient to 180°C |
| Chamber Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm – 1626 mm × 2616 mm × 2515 mm |
| Cold Zone Range | -75°C to 0°C |
| Hot Zone Range | +85°C to +215°C |
| Internal Chamber Volume per Zone | 2.1 ft³ (≈59.5 L) |
| Transfer Time | ≤10 s |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Purge Gas | Dry Nitrogen |
| Defrost Heater | Integrated in Cold Zone |
| Compliance | MIL-STD-202F Method 107G (Conditions A, B, C, F), MIL-STD-883 Method 1010.7 (Conditions A, B, C, F) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,600 (FOB, indicative only — final quotation subject to configuration, certification, and delivery terms) |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | 401A Series |
| Max Operating Temperature | 200°C or 300°C (configurable) |
| Temperature Uniformity | ±1% (forced-air convection) |
| Temperature Control Accuracy | ±1°C |
| Air Exchange Rate | 0–100 cycles/hour |
| Air Velocity | <0.5 m/s |
| Power Supply | AC 220 V, 50 Hz |
| Internal Chamber Dimensions (W×H×D) | 450 × 450 × 450 mm |
| Construction | Cold-rolled steel exterior with high-temp silver paint interior coating and glass fiber insulation |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EB 01-II |
| Max Operating Temperature | 300 °C |
| Chamber Configuration | 4 identical-temperature zones |
| Sample Capacity | 24 standard specimens per chamber |
| Temperature Uniformity | ±0.5 °C |
| Heating Method | Channelled aluminum block preheating |
| Airflow | Natural convection, low-velocity, no forced circulation |
| Compliance | IEC 60811-1-2, ISO 188, ASTM D573 |
| Software Interface | PC-connected, wireless data acquisition via laser-guided arm and digital calipers |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EP 04-II |
| Max Operating Temperature | 300 °C |
| Internal Volume | 60 L |
| Air Exchange Rate | Adjustable 3–20 air changes per hour |
| Compliance | IEC 60811, ISO 188 |
| Chamber Airflow | Controlled forced convection |
| Optional Accessories | EB 04AP (external sensor port), EB 04IIW (viewing window with illumination), EB 04IIDC (door interlock safety switch) |
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (FOB) |
| Internal Dimensions (W×D×H) | 50×50×40 cm / 50×75×60 cm / 80×80×80 cm / 100×100×100 cm |
| External Dimensions | 100×170×90 cm / 110×190×100 cm / 140×190×130 cm / 165×210×150 cm |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 hours |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Chamber Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT+10°C to 200°C / 300°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Air Exchange Rate | 2–100 cycles/hour |
| Adjustable Air Exchange Time | 1 min – 99 h |
| Internal Chamber Dimensions (L×W×H, mm) | 450×450×500 to 800×1000×1000 |
| Power Consumption | 4.0–9.0 kW |
| Rotating Turntable Diameter | Φ250–Φ700 mm |
| Compliance | ASTM D5423-09 (Type II), ASTM D5374-93 (2005), UL 1581, GB, VDE, JIS, IEC |