Pressure Controllers
Filter
Showing all 18 results
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | PHO-EXTEND Series |
| Channel Density | Up to 120 channels per chassis |
| Interface | USB 2.0, Gigabit Ethernet, GPIO |
| DAC Resolution | 16-bit |
| Output Modes | Unipolar, Bipolar, Differential |
| Voltage Range (Standard) | ±16 V, 0–34 V, ±18 V |
| Current Range (Standard) | ±500 mA, 0–300 mA, ±500 mA |
| Software Support | SCPI (Python, C#, MATLAB, LabVIEW), CSV-based sequence programming, GUI with real-time monitoring |
| Processor | Quad-Core 64-bit ARM Cortex-A53 (ARM v8) |
| Compliance | GLP/GMP-ready audit trail logging (Premium firmware), ISO/IEC 17025 traceable calibration support (optional) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHD-3100 |
| Pricing | Upon Request |
| Operating Principle | Electronic Pressure Control |
| Display | Digital LCD |
| Working Medium | Compressed Air |
| Battery | 5800 mAh Rechargeable Li-ion (≥7 days continuous operation) |
| Flow Control | Precision Electronic Mass Flow Control with Mechanical Fine-Tuning |
| Sample Interface | Universal SUMMA Canister Coupling (6-port or 12-port compatible) |
| Internal Surface Treatment | Silanized Stainless Steel Flow Path (including all internal tubing and fittings) |
| Environmental Rating | IP65 (Dust-tight, Water-resistant) |
| Brand | INFICON |
|---|---|
| Origin | Germany |
| Model | IC6 Thin Film Deposition Controller |
| Measurement Principle | Quartz Crystal Microbalance (QCM) with ModeLock Frequency Detection |
| Resolution | 0.00433 Å/s @ 100 ms sampling |
| Frequency Stability | ±0.0035 Hz |
| Max Simultaneous Sources | 6 |
| Layer Capacity | 50 processes × 200 layers = 10,000 total layers |
| Sensor Inputs | Up to 8 QCM sensors (averaged or independent) |
| Display | Color TFT LCD |
| I/O | 28 digital inputs, 24 relay outputs, 14 TTL outputs, 6 standard DACs + 6 optional DACs |
| Logic Engine | 100 programmable logic statements |
| Data Storage | Internal logging, screenshot capture, recipe storage |
| Communication | RS-232/485, optional Ethernet |
| Compliance | RoHS-compliant |
| Software Support | IC6 Configuration Editor (LabVIEW®-based, Windows®) |
| Brand | Shanghai Xiande |
|---|---|
| Origin | Shanghai, China |
| Model | GMVC-3000pro |
| Control Range | 1–800 mmHg (Torr), 1–1066 hPa (mbar), 0–106.6 kPa, 0 to –0.01 MPa |
| Pressure Type | Negative (Vacuum) |
| Display | Digital Touchscreen (5.5″ Color LCD) |
| Ultimate Vacuum | 8 mbar |
| Max Pumping Speed | 20 or 30 L/min |
| Interface | Quick-Connect Ø10 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 130 W |
| Standby Power | 3 W |
| Noise Level | ≤55 dB(A) |
| Operating Temperature | 5–40 °C |
| IP Rating | IP20 |
| Dimensions (L×W×H) | 185 × 310 × 310 mm |
| Weight | 13 kg |
| Optional Steam Temperature Monitoring | –20 to 200 °C |
| Brand | Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | SIM960 |
| Input Range | ±10 V (single-ended), ±1 V (differential) |
| Proportional Gain | 10⁻¹–10³ |
| Integral Gain | 10⁻¹–10⁵ s⁻¹ |
| Derivative Gain | 10⁻⁷–10⁻¹ s |
| Control Bandwidth | 100 kHz |
| Input Noise Density | 8 nV/√Hz (above 10 Hz) |
| Output Slew Rate | User-Programmable via Internal Ramp Generator |
| Output Clamping | Adjustable Upper/Lower Limits |
| Anti-Windup | Active Integral Anti-Saturation Circuitry |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | RPC30 |
| Sensor Technology | Thermal Mass Flow-Based Differential Pressure Sensing |
| Compliance | ANSI/ASHRAE/ASHE Standard 170-2008, FGI Guidelines 2010, CDC Environmental Infection Control Guidelines, USP <797> |
| Alarm System | Dual visual (LED) and audible (85 dB @ 1 m), user-configurable delay |
| Input Support | Differential pressure (±125 Pa), temperature (–10 to 60 °C), relative humidity (0–100 % RH), volumetric airflow (4–20 mA or 0–10 V analog inputs) |
| Control Output | 0–10 V DC or 4–20 mA for damper/valve actuation |
| Display | Color touchscreen (4.3″, capacitive), icon-driven UI with real-time status visualization |
| Communication | BACnet MS/TP, Modbus RTU, optional BACnet/IP via gateway |
| Security | Password-protected configuration access (admin/user levels) |
| Operating Mode | Isolation (AII/PE/OR) ↔ Neutral (non-isolation) toggle via physical key switch |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | RPM10 |
| Sensor Technology | Thermal Mass Flow-Based Differential Pressure Sensing |
| Compliance | ANSI/ASHRAE/ASHE Standard 170-2008, FGI Guidelines 2010, CDC Environmental Infection Control Guidelines, USP <797> |
| Alarm Types | Visual (LED status ring + touchscreen icon) and Audible (adjustable threshold & delay) |
| Operating Modes | Isolation (AII/PE), Neutral/Non-Isolation |
| Interface | Local touch-screen programming, BACnet MS/TP or Modbus RTU (optional), physical mode toggle switch |
| Security | Password-protected configuration access |
| Display | Color LCD with intuitive status visualization (e.g., green = nominal, amber = warning, red = alarm) |
| Enclosure Rating | IP42 |
| Power | 24 VDC (PoE-compatible option available) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | RPM20 |
| Sensor Technology | Thermal Anemometer–Based Differential Pressure Sensing |
| Compliance | ANSI/ASHRAE/ASHE Standard 170-2008, FGI Guidelines 2010, CDC Environmental Infection Control Recommendations |
| Alarm Logic | Adjustable Delay, Dual-Stage Visual & Audible Alert |
| Display | Color Touchscreen with Status-Color-Coded Interface |
| Connectivity | BACnet MS/TP, Modbus RTU, Ethernet (Optional) |
| Input Channels | 2 Differential Pressure Ports + Optional Temp/RH Inputs |
| Configuration | Local Keypad + Password-Protected Setup |
| Operating Modes | Isolation (Negative/Positive), Neutral, Non-Isolation |
| Max Monitoring Zones | 2 Isolation Rooms + 1 Anteroom |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8636 |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Communication Protocol | MODBUS RTU (open standard) |
| Power Input | 120 VAC, output: 24 VAC |
| Sensor Type | Wall-mounted differential pressure transducer |
| Control Outputs | Dual analog (0–10 VDC or 4–20 mA) for supply & exhaust dampers, auxiliary outputs for heating/cooling control |
| Alarm Interface | Relay output with visual & audible alert |
| Enclosure Rating | NEMA 1 (indoor use) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–90 % RH (non-condensing) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8681 |
| Control Principle | Differential Pressure-Based Closed-Loop Airflow Balancing |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Communication Protocol | MODBUS RTU (Open Standard) |
| Power Input | 120 VAC → 24 VAC (included transformer) |
| Sensor Interface | Dedicated wall-mount differential pressure transducer (included) |
| Alarm Output | Relay + visual/audible indicators |
| Temperature Control Capability | Integrated supply air heating & volume modulation |
| Enclosure Type | Standalone DIN-rail or surface-mount controller |
| Software Integration | BMS-ready via RS-485 serial interface |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8682 |
| Communication Protocol | Modbus RTU (Open Standard) |
| Power Input | 120 VAC to 24 VAC, 25 VA |
| Control Outputs | Relay Alarm + Analog/Digital Interface |
| Sensor Compatibility | External Room Pressure Transducer (Optional) |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Integration | BMS via Modbus or LonWorks (Optional) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8682-ST |
| Control Channels | Up to 5 independent duct systems |
| Pressure Sensing | Differential pressure transducer input |
| Output Interfaces | Analog (4–20 mA / 0–10 V), Relay alarms, MODBUS RTU (RS-485) |
| Power Supply | 120 VAC to 24 VAC transformer included (25 VA) |
| Enclosure | NEMA 1 indoor-rated |
| Compliance | CE, RoHS |
| Software Integration | Compatible with BMS via open MODBUS protocol |
| Alarm Logic | Adjustable delay to suppress transient false alarms |
| Local Interface | Backlit keypad and LCD display with password-protected configuration |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | CVC 3000 High-Vacuum Kit |
| Measurement Principle | Pirani (Thermal Conductivity) Gauge |
| Pressure Range | 1×10³ mbar to 1×10⁻³ mbar |
| Sensor Uncertainty | ±15% of reading (0.01–10 mbar) |
| Sensor Cable Length | 2 m |
| Interface Protocol | VACUU·BUS® |
| Valve Type | VV-B 15C Solenoid Direct-Acting Valve |
| Flange Options | KF DN 16 or KF DN 25 |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | VACUUBRAND® |
|---|---|
| Origin | Germany |
| Model | VACUU·SELECT |
| Control Range | Down to 10⁻³ mbar |
| Control Methods | Two-Point (Solenoid Valve) & VARIO® Variable-Speed Drive |
| Display | Capacitive Touchscreen Interface |
| Language Support | 14 Languages |
| Material Compatibility | Chemically Resistant (PTFE, FKM, PP, Borosilicate Glass) |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Application Scope | Laboratory Vacuum Networks, Rotary Evaporation, Freeze Drying, Schlenk Line Operations, Chemical Distillation |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC2000 |
| Control Principle | Electronic Pressure Control |
| Display Type | Digital |
| Pressure Control Range | 0.1–100 kPa |
| Accuracy | ±0.1 % FS |
| Integrated Automatic Pressure Source | Yes |
| Power Options | AC Adapter or Rechargeable Li-ion Battery |
| Zeroing | Automatic On Startup |
| Communication Interfaces | RS-232, USB |
| Compliance Certifications | Factory Calibration Certificate Included |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPC6050 |
| Pricing | Upon Request |
| Operating Principle | Electronic Pressure Control |
| Display | Digital |
| Control Stability | < 0.003 % FS (typical 0.001 % FS) |
| Pressure Range | –0.1 to 21 MPa |
| Control Response Time | < 10 s |
| Accuracy | ±0.01 % of reading (upper half of span, IS-50 compliant) |
| Uncertainty Budget | k=2, includes instrument intrinsic performance, reference standard uncertainty, long-term stability, environmental effects, zero-drift beyond auto-compensation range, and temperature influence |
| Calibration Interval | 180 days for gauge/absolute pressures ≤ 0.1 MPa and bidirectional ranges ≤ 1 MPa |
| Sensor Recommendation | Absolute pressure sensor preferred for pressure simulation to enable effective zero-point drift compensation |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC8000 |
| Operating Principle | Electronic Pressure Control |
| Display | Digital LCD with Capacitive Glass Touchscreen |
| Pressure Control Range | Up to 40 MPa |
| Control Stability | 0.002% FS |
| Pressure Types | Gauge (Positive/Negative), Absolute |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC4000 |
| Operating Principle | Electronic Pressure Control |
| Display | Digital |
| Control Stability | < 0.005 % FS |
| Control Speed | < 10 s |
| Accuracy | 0.02 % of reading (50–100 % FS), 0.02 % of half-scale (0–50 % FS) |
| Pressure Range | –0.1 to 21 MPa |
| Uncertainty Budget | Expanded uncertainty (k = 2) per ISO/IEC 17025, incorporating sensor intrinsic performance, reference standard uncertainty, long-term drift, thermal effects, zero-shift beyond auto-compensation range, and environmental influences |