Metal Elemental Analyzer
Filter
Showing 1–30 of 43 results
| Brand | Belec |
|---|---|
| Origin | Germany |
| Model | Belec In-Spect |
| Dimensions | 750 mm × 380 mm × 600 mm |
| Optical System | 5th-Generation Spark-OES (5GSO) |
| Detector | CCD-based multi-channel spectrometer |
| Elemental Range | C, P, S, N, and standard metallic elements (Fe, Al, Cu, Zn, Ni, Ti, Mg, etc.) |
| Electrode Type | Low-consumption tungsten electrode |
| Spark Stand | Open-type, accommodating large or irregular samples |
| Calibration Stability | MCDC (Multi-Channel Drift Correction) enabled, maintaining calibration integrity for up to 2–3 weeks under routine operation |
| Software | Belec Win21 with configurable language support (10 languages including English, Chinese, German, French, Spanish, Italian, Japanese, Korean, Russian, Portuguese) |
| Compliance | Designed to meet ISO 17025 laboratory requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Elemental Range | Ti to Bi (including Au, Ag, Pt, Pd, Rh, Ru, Ir, Ni, Cu, Fe, Zn, Sn, Pb, Cd, Cr, Co, Mn, Sb, Ti) |
| Detector | SharpBeam™ Optimized Silicon Drift Detector (SDD) with Optional Pin-Proof Shield™ |
| X-ray Tube | 50 kV Max Excitation |
| Display | High-Contrast LCD Touchscreen |
| Optional Accessories | Integrated CCD Color Camera, Micro-Spot Collimation, Desktop/Tripod Mount, Remote Control Interface |
| Compliance | Designed for GLP/GMP environments |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DHF83 |
| Price Range | USD 1,400 – 7,200 |
| Brand | ESI |
|---|---|
| Model | EDX9000A |
| Element Range | Na (11) – U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Excitation Source | 50 W Rh-target X-ray tube, 0–50 kV |
| Detector | AmpTek high-resolution silicon drift detector (SDD) |
| DPP Analyzer | 4096-channel digital pulse processor |
| Sample Chamber Dimensions | 460 × 310 × 95 mm |
| Vacuum Chamber | Φ150 mm × 75 mm |
| Instrument Dimensions | 560 × 380 × 410 mm |
| Weight | 45 kg |
| Operating Environment | −10 °C to 35 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | FocusSens / Beijing Michem Technology Ltd. |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | MiX5 |
| Pricing | Available Upon Request |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | HM-550 |
| Price | USD 25,000 (FOB Qingdao) |
| Measurable Elements | Na (11) to U (92) |
| Dimensions | 700 mm × 510 mm × 336 mm |
| Weight | 56 kg |
| Vacuum Chamber Dimensions | 400 mm × 340 mm × 80 mm |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 40–70 % RH |
| Power Supply | AC 220 V ±5 V, 50/60 Hz |
| Detection Limit (RoHS elements) | 1 ppm |
| Measurement Time | 100–300 s (user-adjustable) |
| Energy Resolution | 129 ±5 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD), Peltier-cooled |
| X-ray Tube | Max. 50 kV / 1 mA, tungsten anode |
| Vacuum Pump | 60 L/min, ultimate pressure 6.7×10⁻² Pa |
| Collimator Options | 7 fixed apertures (2–8 mm diameter) |
| Filter Options | 5 automatic filters |
| Spectral Channels | 4096-channel digital MCA |
| Interface | USB 2.0 |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IG5C |
| Price | Upon Request |
| Ion Energy Range | 500 eV – 5 keV |
| Maximum Beam Current | 200 nA |
| Minimum Spot Size | 20 µm |
| Ion Source Lifetime | ~500 hours |
| Flange Type | DN-35 CF Conflat Wedge Flange |
| Power Consumption | 8 W |
| Filament Configuration | Dual-filament |
| Vacuum Compatibility | Optimized for UHV systems (<1×10⁻⁹ mbar) |
| Beam Blanking | Integrated electrostatic blanking for rapid beam on/off switching in grating applications |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XRF Scanner |
| Price Range | USD 27,000 – 68,000 (FOB) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MH-5000 |
| Pricing | Available Upon Request |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DC2000 |
| Detector Type | Si-PIN |
| Excitation Source | Microfocus X-ray Tube (8–40 kV) |
| Cooling System | Peltier Thermoelectric (operable down to −35 °C) |
| Filter Set | 8-position automatic filter changer |
| Display | High-resolution Blanview transmissive backlight color touchscreen |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% (non-condensing) |
| Battery | Dual hot-swappable Li-ion batteries |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 (Microsoft-compatible stack) |
| OS | Windows CE 6.0 |
| Compliance | Meets IEC 61000-4 EMC standards |
| Sample Compatibility | Solid metals, welds, castings, forgings, and scrap alloys up to 480 °C surface temperature |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO200 |
| Detector | 25 mm² SDD Silicon Drift Detector |
| Excitation Source | Micro-focus X-ray Tube (8–40 kV) |
| Cooling System | Peltier Thermoelectric Cooling (operable down to −35 °C) |
| Filter Set | 8-position automatic filter changer |
| Display | High-resolution transflective color touchscreen |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% non-condensing |
| Battery | Dual hot-swappable Li-ion batteries |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth v2.1 + EDR |
| OS | Windows CE 6.0 |
| Software | Olympus Delta PC Suite (remote control, report generation, spectral review) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4050 |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Excitation Source | High-Power Micro-Focus X-ray Tube (15–50 kV) |
| Cooling System | Peltier Thermoelectric Cooler (operable down to −35 °C) |
| Filter Set | 8-position Automatic Filter Wheel |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Transflective Color Touchscreen |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 4.0 (Microsoft Mobile Device Center compatible) |
| Operating System | Windows CE 6.0 |
| Analysis Modes | Up to 25 User-Configurable Calibration Modes |
| Light Element Compensation | Integrated Barometric Pressure Sensor & Accelerometer for Atmospheric Correction |
| Brand | Qilin (QL) |
|---|---|
| Model | BS1000G |
| Origin | Jiangsu, China |
| Type | Benchtop Photometric Elemental Analyzer |
| Optical System | Adjustable-Wavelength Self-Collimating Diffraction Grating (Right-Exit) |
| Wavelength Accuracy | ±3 nm |
| Measurable Elements (typical) | Mn (0.10–65.00 wt%), Si (0.10–75.00 wt%), P (0.005–1.00 wt%), Cu (0.02–85.00 wt%), Cr (0.01–45.00 wt%), Ni (0.01–50.00 wt%), Mo (0.101–6.00 wt%), Mg (0.010–0.100 wt%), Rare Earths (0.01–0.100 wt%) |
| Analytical Method | Photometric Colorimetry with Computer-Controlled Wavelength Selection |
| Measurement Time per Sample | ≤5 s |
| Weighing Device | 0.0001 g Precision Electronic Balance (1/10,000 g resolution) |
| Compliance | GB/T 223 series (Chinese national standards for metallurgical analysis) |
| Operating Environment | 10–30 °C, RH <75% |
| Data Output | Integrated thermal printer (Chinese-language interface), PC-based data logging |
| Brand | Qilin / QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QL-BS3B |
| Price | USD 1,380 (FOB Nanjing) |
| Measurement Principle | Photometric Colorimetry with Cold Light Sources |
| Elements Measured | Si, Mn, P, Ni, Cr, Cu, Rare Earths, Mg, Fe, Al, V, W, Ti |
| Typical Range (w/w) | Mn 0.10–15.00%, Si 0.10–5.00%, P 0.005–0.80%, Cr 0.010–25.0%, Mo 0.010–6.00%, Mg 0.010–0.99% |
| Detection Method | Dual-beam photometry using imported silicon photodiodes |
| Calibration | Automatic zero & full-scale self-calibration |
| Curve Storage | 15 user-programmable calibration curves |
| Input Interface | Touch-sensitive membrane keypad with audible feedback |
| Sample Preparation | External fusion (crucible-based), valve-free and tubing-free design |
| Optical Source | Interchangeable cold-light sources for spectral adaptability |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | S3000C |
| Price | USD 9,500 (FOB Jiangsu) |
| Brand | QL |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | BS1000G |
| Price | USD 3,650 (FOB) |
| Wavelength Range | 400–800 nm (motorized continuous adjustment) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Measurement Time | ~120 s per sample |
| Analytical Accuracy | Compliant with GB/T 223.3–223.5–1988 and equivalent ISO/ASTM practices for photometric elemental analysis |
| Detection Elements | Si, Mn, P, Cr, Ni, Mo, Cu, Ti, V, Mg, Al, W, Rare Earths (Ce, La), Fe, etc. |
| Calibration Curves | 99 programmable polynomial regression curves per element |
| Sample Introduction | Off-line acid digestion (external dissolution) followed by photometric measurement |
| Light Source | Stabilized cold LED array with auto-zero and full-scale calibration |
| Data Interface | RS-232/USB to Windows PC |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Max. Power Consumption | ≤350 W |
| Brand | QL |
|---|---|
| Model | BS3B |
| Origin | Jiangsu, China |
| Type | Cold-light Source Spectrophotometric Multi-Element Analyzer for Metals |
| Measurement Principle | Dual-beam Photometric Absorption (Cold Light Source) with Silicon Photodiode Detection |
| Element Range | Mn 0.10–15.00%, Si 0.10–5.00%, P 0.005–0.80%, Cr 0.010–25.0%, Mo 0.010–6.00%, Mg 0.010–0.99% |
| Calibration Curves | Up to 15 user-storable calibration curves |
| Optical System | Fixed-wavelength cold light source modules with automatic zero/full-scale self-calibration |
| Sample Form | Solid metal samples (pre-dissolved or fused into solution) |
| Interface | Touch-sensitive keypad with audible key feedback |
| External Melting Design | Yes |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 620 × 420 × 220 mm |
| Weight | 28 kg |
| Brand | QL Instrument |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-BS1000G |
| Detection Principle | Photometric Colorimetry with Self-Aligning Exit-Slit Diffraction Grating Optical System |
| Wavelength Selection | Computer-Automated |
| Measurement Time per Element | ≤5 s |
| Weighing Device | Analytical Balance (0.0001 g resolution) |
| Sample Type | Solid metallic alloys (as dissolved acid digests) |
| Temperature Range | 10–30 °C |
| Relative Humidity | <75% RH |
| Compliance | GB/T 223 series (e.g., GB/T 223.3–2008, GB/T 223.5–2008, GB/T 223.11–2008) |
| Software Interface | Native Chinese GUI with integrated printer driver (RS-232/USB) |
| Optical Architecture | Custom-designed exit-slit grating monochromator with fixed slit width and adjustable wavelength positioning |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-28W |
| Type | Portable Emission Spectroscopic Analyzer (Arc/Spark Excitation) |
| Wavelength Range | 390–700 nm |
| Operating Voltage | AC 220 V, 50 Hz |
| Arc Current | ~5 A |
| Host Weight | 4.5 kg |
| Generator Weight | 3.0 kg |
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Compliance | Domestic GB/T Standards for Metal Spectral Analysis Instruments |
| Pricing | USD 1,780 (FOB Jiangsu) |
| Brand | Kirin |
|---|---|
| Model | QL-5800A |
| Optical System | Paschen–Runge Mount |
| Focal Length | 750 mm |
| Grating | 2400 grooves/mm concave |
| Wavelength Range | 130–650 nm |
| Dispersion | 0.55 nm/mm (1st order) |
| Slit Widths | 20 µm (entrance), 35/55/75 µm (exit) |
| Analytical Channels | 32 standard, up to 48 configurable |
| Vacuum System | Dual-valve controlled high-vacuum chamber |
| Argon Purity | ≥99.995% |
| Argon Pressure | 0.3–0.5 MPa |
| Analysis Time per Sample | ~20 s |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Power Consumption | 1.5 kW |
| Dimensions (L×W×H) | 1150 × 950 × 1200 mm |
| Weight | ~300 kg |
| Operating System | Windows XP or Vista (multi-language support: English, Chinese, Japanese, Korean) |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-BS1000 |
| Wavelength Range | 400–800 nm (continuously adjustable) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Wavelength Accuracy | ±3 nm |
| Photometric Resolution | 0.001 A |
| Data Storage | Onboard EEPROM (retains data for ≥10 years without power) |
| Display | 1-inch numeric LED display |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power Consumption | ≤45 W |
| Net Weight | ≤15 kg |
| Compliance | Designed per GB/T 20001.4–2015 (Chinese Standard for Analytical Instrument Documentation), compatible with ASTM E306 and ISO 4943 methodologies for optical emission and absorption-based metal analysis |
| Brand | Qilin (QL) |
|---|---|
| Model | QL-BS1000 |
| Origin | Jiangsu, China |
| Wavelength Range | 400–800 nm (continuously adjustable) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Wavelength Accuracy | ±3 nm |
| Data Storage | Onboard EEPROM (retains data for ≥10 years without power) |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power Consumption | ≤45 W |
| Net Weight | ≤15 kg |
| Display | 1-inch numeric LED display |
| Calibration | Auto-zero and full-scale calibration using cold light source and imported photodetectors |
| Curve Storage | Up to 9 pre-programmed calibration curves |
| Sample Handling | External dissolution |
| Optical System | Adjustable-wavelength monochromatic light source with microprocessor-controlled spectral selection |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-BS1000G |
| Wavelength Range | 400–750 nm (motorized auto-adjustable) |
| Absorbance Range | 0–1.999 A |
| Concentration Display Range | 0.000–99.99% (auto-ranging) |
| Measurement Time | ~2 minutes per sample |
| Analytical Accuracy | Compliant with GB/T 223.3–223.5–1988 and equivalent ISO/ASTM elemental analysis standards |
| Detection Elements | Si, Mn, P, Cr, Ni, Mo, Cu, Ti, V, Mg, Al, W, Rare Earths (Ce, La), Fe, etc. |
| Calibration Curves | Up to 99 user-definable, regression-based calibration curves stored in PC memory |
| Sample Introduction | Off-instrument acid dissolution (external digestion) |
| Detection Principle | Photometric colorimetry with tunable-wavelength optical system |
| Power Supply | AC 220 V ±10%, 50 Hz ±5% |
| Power Consumption | 350 W |
| Interface | PC-controlled via USB/RS232 |
| Brand | Qilin (QL) |
|---|---|
| Model | HW2000C |
| Origin | Jiangsu, China |
| Detection Principle | High-Frequency Induction Combustion Coupled with Dual-Wavelength NDIR Spectrometry |
| Measurement Range | C: 0.0001–25.0000 wt% (extendable to 99.999%) |
| S | 0.0001–15.0000 wt% (extendable to 99.999%) |
| Precision | Compliant with GB/T 20123–2006 and ISO 15350:2000 |
| Sample Mass | 0.5 g (standard solid steel reference) |
| Analysis Time | 20–100 s (typical: 35 s) |
| Sensitivity | 0.1 ppm for both C and S |
| HF Generator Output | 2200 W at 20 MHz |
| IR Source | Platinum-heated micro-source (800 °C), CO₂ band: 4.26 µm, SO₂ band: 7.4 µm |
| Detector | Gold-coated absorption cell with high-stability pyroelectric detector |
| Modulation Frequency | 64 Hz |
| Data Acquisition | 24-bit ADS1224 ADC, 20 Hz real-time sampling |
| Communication | USB 2.0 interface between host PC and embedded controller |
| Dust Filtration | 0.4 µm sintered metal filter |
| Furnace Auto-Diagnostics | Leak detection, over-current/over-time alarm, thermal stabilization via stepped motor-driven temperature control |
| [Brand | QL-Qilin |
|---|---|
| Model | HW2000BA |
| Origin | Jiangsu, China |
| Type | Integrated HF-IR C/S + Optical Emission Multi-Element Analyzer |
| Measuring Range (C) | 0.0001–99.999 wt% |
| Measuring Range (S) | 0.0001–99.999 wt% |
| RSD (C) | ≤0.5% |
| RSD (S) | ≤1.0% |
| Detection Limit | 0.1 ppm |
| Analysis Time | 25–60 s (adjustable, typical 35 s) |
| HF Generator | 2.5 kVA, 18–20 MHz |
| Weighing Precision | 0.1 mg (0–120 g capacity) |
| Compliance | GB/T 20123–2006, ISO 15350:2000] |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QL-S3000A |
| Price | USD 7,200 (FOB Jiangsu) |
| Measurement Principle | Combustion-Gas Volumetric (C), Iodometric Titration (S), and Computer-Controlled Photometric Colorimetry (Multi-Element) |
| Optical System | Motorized Grating Monochromator with Digital Wavelength Tuning (400–800 nm, resolution <1 nm) |
| Sample Throughput | ~2 min per full multi-element analysis (C, S, Si, Mn, P, Cr, Ni, Mo, Cu, Ti, etc.) |
| Calibration Capacity | Up to 99 user-definable calibration curves (linear & polynomial regression), expandable |
| Compliance | Meets GB/T 223.3–5:1988 and GB/T 223.68–69:1997 |
| Data Interface | RS-232/USB to industrial-grade Windows PC |
| Sample Handling | Off-line acid dissolution (non-pressurized) |
| Detection Range Examples | C 0.05–6.00 wt%, S 0.005–0.300 wt%, Mn 0.10–15.00 wt%, Si 0.10–5.00 wt%, P 0.005–0.80 wt%, Cr 0.01–25.0 wt%, Ni 0.01–30.0 wt%, Mo 0.101–6.00 wt%, Ti 0.01–5.00 wt% |
| Repeatability | RSD ≤1.5% for mid-range concentrations (per GB standards) |
| Environmental Rating | Designed for controlled laboratory environments (15–30 °C, <80% RH non-condensing) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | S3000C |
| Price | USD 8,100 (FOB Jiangsu) |
| Measurement Principle | IR Absorption (C/S) + Photometric Colorimetry (Multi-element) |
| Wavelength Range | 400–800 nm (Motorized Grating, Digital Step Control, Resolution <1 nm) |
| Sample Form | Solid metallic alloys (ferrous & non-ferrous), pre-digested solutions |
| Analysis Time | ~5 min per sample (C+S+up to 12 additional elements) |
| Calibration Curves | 99 user-storable regression-based calibration curves |
| Compliance | Meets GB/T 223.3–5:1988 and GB/T 223.68–69:1997 requirements for ferrous metallurgical analysis |
| Data Output | CSV, Excel, PDF via Windows-compatible PC interface |
| Sample Introduction | Off-line acid digestion (HCl/HNO₃/HF mixtures), followed by automated photometric measurement |
| Weight Integration | Optional RS-232/USB connection to analytical balance (0.1 mg resolution) |
| Optical System | Patented motor-driven holographic grating monochromator with zero-point auto-calibration |
| Reagent Delivery | Electrodeless titration dosing system with anti-clogging valve design |
| Software Platform | QL-Analyze v4.2 (Windows 10/11), supports CFR 21 Part 11 user authentication and electronic signature modules |
| Brand | Qilin (QL) |
|---|---|
| Origin | Jiangsu, China |
| Model | QL-S3000C |
| Measurement Principle | Infrared Absorption (C/S) + Photometric Colorimetry (Multi-element) |
| Elemental Range | C (0.001–10.00%), S (0.0005–0.5000%), Mn (0.10–15.00%), Si (0.10–5.00%), P (0.005–0.80%), Cr (0.01–25.0%), Mo (0.101–6.00%), Ni (0.010–30.0%), Mg (0.010–0.100%), Rare Earths (0.01–0.100%), Cu, Al, V, W, Ti, Fe, etc. |
| Analysis Time | ~5 min (combined IR + photometric mode) |
| Wavelength Adjustment | Motor-driven holographic grating, digitally controlled, 400–800 nm, step resolution <1 nm |
| Calibration Curves | Up to 99 user-storable regression curves |
| Compliance | GB/T 223.3–5:1988, GB/T 223.68–69:1997 |
| Sample Handling | Off-line dissolution, variable-mass weighing via optional electronic balance interface |
| Data Output | ASCII/CSV export, direct thermal or dot-matrix printing |
| Software Control | Windows-based GUI with real-time data acquisition, audit trail logging, and GLP-compliant result archiving |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QL-S3000C |
| Price | USD 8,100 (FOB Jiangsu) |
| Measurement Principle | IR Absorption (C/S) + Photometric Colorimetry (Multi-Element) |
| Wavelength Range | 400–800 nm (Digitally Tunable via Stepper-Motor-Driven Diffraction Grating) |
| Carbon Range | 0.001–10.00 wt% |
| Sulfur Range | 0.0005–0.5000 wt% |
| Mn | 0.10–15.00 wt% |
| Si | 0.10–5.00 wt% |
| P | 0.005–0.80 wt% |
| Cr | 0.01–25.0 wt% |
| Ni | 0.010–30.0 wt% |
| Mo | 0.101–6.00 wt% |
| Mg | 0.010–0.100 wt% |
| Rare Earths | 0.01–0.100 wt% |
| Analysis Time | ~300 s (IR + Colorimetric modules, sequential) |
| Calibration Curves | 99 programmable regression-based calibration curves |
| Data Output | CSV, TXT, or custom format via USB/RS232 |
| Compliance | Meets requirements of GB/T 223 series (e.g., GB/T 223.3–5:1988, GB/T 223.68–69:1997) |