Surface & Interface Property Testing
Filter
Showing 1–30 of 189 results
| Brand | 3P Instruments |
|---|---|
| Origin | Germany |
| Model | mixSorb L |
| Maximum Adsorption Pressure | 68 bar |
| Number of Mass Flow Controllers (MFCs) | 4 |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Dimensions (Standard) | 30 mm ID × 200 mm length |
| Gas Range | Customizable |
| Column Configuration | Customizable |
| Temperature Pre-treatment Range | Up to 400 °C |
| Heating Rate | Up to 10 K/min |
| Software | mixSorb Manager & 3P sim |
| Compliance | Designed for GLP/GMP-aligned operation with audit-trail-capable data logging |
| Brand | 3P Instruments |
|---|---|
| Origin | Germany |
| Model | mixSorb S |
| Maximum Adsorption Pressure | 68 bar |
| Mass Flow Controllers (MFCs) | 4 |
| Detector | TCD (Thermal Conductivity Detector) |
| Temperature Control | Up to 400 °C pre-treatment, Linear Heating Rate: 10 K/min |
| Software | mixSorb Manager (real-time control & programmable operation), 3P sim (data fitting, breakthrough curve simulation, multicomponent adsorption modeling, selectivity/affinity/kinetics calculation) |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Caisits |
| Price Range | USD 28,000 – 70,000 |
| Brand | Aisida |
|---|---|
| Model | JK2400 |
| Measurement Principle | Contactless CIS-based optical imaging with diffuse LED illumination |
| Pore Diameter Range | 0.10–10.0 mm |
| PCB Size Capacity | 120 × 64 mm to 610 × 610 mm |
| PCB Thickness Range | 0.08–10 mm |
| Max. Hole Count per Scan | 600,000 |
| Inspection Speed | 4.2 m/min |
| Diameter Measurement Accuracy | ≤21 µm |
| Tolerance Specification | ±50 µm |
| Imaging Method | Proximity CIS line-scan sensor with short-focus lens |
| Light Source | Diffuse linear LED array |
| Power Supply | 220 V AC, 15 A, 3 kW |
| Compressed Air Requirement | 0.6 MPa |
| Dimensions (L×W×H) | 4050 × 1280 × 1220 mm |
| Weight | 450 kg |
| Data Storage | Integrated relational database with timestamped audit trail |
| Communication Interface | CAN bus architecture |
| Compliance Framework | Designed for integration into ISO 9001-certified PCB manufacturing lines |
| Brand | Aisida |
|---|---|
| Model | TDR-ZK2130 |
| Origin | Guangdong, China |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Impedance Range (Single-Ended) | 10–150 Ω |
| Impedance Range (Differential) | 20–300 Ω |
| Accuracy (at 50 Ω) | ±1% |
| Repeatability (at 50 Ω) | ±0.5% |
| Measurement Length | 0.04–2 m |
| Horizontal Resolution | 0.2 mm |
| Vertical Resolution | 0.03 Ω |
| TDR Bandwidth | >3 GHz |
| Sampling Oscilloscope Bandwidth | >5 GHz |
| Incident Pulse Rise Time | <80 ps |
| Time Sampling Resolution | 10 ps |
| Supported Modes | Single-ended, Differential, Common-mode impedance |
| Statistical Process Control (SPC) Module | Integrated |
| Channel Configurations | 2-channel or 4-channel operation |
| Compliance Standards | IEEE 1394a/b, DiiVA, DisplayPort, HDMI 1.4, SATA I/II, USB 2.0/3.0 |
| Brand | Aisida |
|---|---|
| Model | ZK2120 |
| Origin | Guangdong, China |
| Type | TDR-Based Differential/Single-Ended Impedance Analyzer |
| Impedance Range | Single-Ended 10–150 Ω, Differential 20–300 Ω |
| Measurement Accuracy | ±1% at 50 Ω |
| Repeatability | ±0.5% at 50 Ω |
| TDR Bandwidth | >1.75 GHz |
| Sampling Oscilloscope Bandwidth | >3 GHz |
| Rise Time | <120 ps |
| Time Resolution | 10 ps |
| Length Measurement Range | 0.04–2 m |
| Horizontal Display Resolution | 0.2 mm |
| Vertical Display Resolution | 0.03 Ω |
| Supported Modes | Single-Ended, Differential, Common-Mode, Skew (Intra-Pair & Inter-Pair) |
| Compliance Standards | IEEE 1394a/b, DiiVA, DisplayPort, HDMI 1.4, SATA I/II, USB 2.0/3.0 |
| Brand | Aisida |
|---|---|
| Model | ZK2130 |
| Origin | Guangdong, China |
| Testing Principle | Time-Domain Reflectometry (TDR) |
| Impedance Range | 20–150 Ω |
| Measurement Accuracy | ±1% at 50 Ω |
| Maximum Test Length | 2 m |
| Horizontal Resolution | 0.2 mm |
| Vertical Resolution | 0.05 Ω |
| Bandwidth | 3 GHz |
| Supported Configurations | Single-ended & Differential Impedance |
| Channel Options | 2-channel or 4-channel |
| Compliance | IPC-TM-650, IPC-2141 |
| Data Analysis | Integrated SPC module with statistical reporting |
| Operating System | Windows-based GUI |
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZK2130 |
| Pricing | Upon Request |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BES |
| Price | USD 1,700 (approx.) |
| Resistance Range | 1 × 10⁴ Ω to 1 × 10¹⁸ Ω |
| Current Range | 2 × 10⁻⁴ A to 1 × 10⁻¹⁶ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V (selectable) |
| Basic Accuracy | ±1% |
| Display | 32-bit LED LCD (simultaneous resistance and current readout) |
| Operating Environment | 0–40 °C, <80% RH |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | ~2.5 kg |
| Standard Electrodes | Solid disc electrode (Ø100 mm), concentric ring electrode (OD 75 mm / ID 55 ± 0.2 mm), cylindrical electrode (Ø50 mm), point-to-point probe set |
| Shielding Enclosure | 200 mm × 200 mm × 90 mm (internal height 50 mm) |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C (optional low-temp module: –130°C to 1200°C) |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated high-sensitivity TCD (dual-filament or quad-filament, W or Au/W), compatible with external MS, FTIR, FID, GC |
| Gas Handling | Built-in precision gas mixer, heated/insulated lines & valves, vapor-saturated gas generation (temperature-controlled saturator) |
| Sample Configuration | Removable clamshell furnace, quartz U-tube/bubble tube/straight-wall tubes (low-pressure) |
| Safety Systems | Multi-point temperature monitoring, over-temperature cutoff, TCD flow interlock, dry-run protection, front emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace + bed), FDA 21 CFR Part 11–ready audit trail (optional), GLP/GMP-compliant data export |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated High-Sensitivity TCD (dual-filament or quad-filament, W or Au/W), MS/GC/FTIR/FID compatibility |
| Sample Capacity | 0.1–1.0 g |
| Sample Tube Types | Quartz U-tube, bubble tube, straight-wall tube (low-pressure) |
| Tubing | 1/16″ OD 316 SS, heated throughout |
| Gas Mixing | Internal precision gas mixer (no external mixer required) |
| Cooling | Automated air-cooling module |
| Safety Systems | Dual-zone temperature monitoring, over-temperature cutoff, TCD flow interlock, front-panel emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace & bed), GLP-compliant data audit trail, FDA 21 CFR Part 11-ready configuration options |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 TPD/TPO/TPR Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AMI-300HP High-Pressure Chemisorption Analyzer (100 bar) |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable up to 12 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar / 100 bar (dual-range configuration) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300IR In Situ FTIR-Coupled Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300Neo Basic Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Ramp Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira |
|---|---|
| Origin | USA |
| Model | AMI-300S Corrosion-Resistant Chemisorption Analyzer |
| Testing Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional 100 bar) |
| Analytical Capabilities | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AMI-400 Automated Chemisorption Analyzer |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Ankersmid |
|---|---|
| Origin | USA |
| Model | PSA-300LC and PSA-1000 |
| Gas Inlets | 2 (customizable) |
| Heating Temperature Range | 0–350 °C |
| Isothermal Stability | ±0.1 °C |
| Pressure Range | 0–1000 psi (68.9 bar) |
| Test Function | Simulated PSA/TSA/VSA Cycles, Breakthrough Curve Analysis, Multicomponent Gas Adsorption |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Chemisorption Analyzer |
| Model | Autosorb 6300 |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1100 °C |
| Isothermal Stability | ±1 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Analytical Modes | TPR, TPO, TPD, Pulse Titration |
| Detection | Integrated TCD, Optional Mass Spectrometer |
| Vapor Source | Built-in |
| Dewar Duration | >90 h (LN₂) |
| Degassing Stations | 6 PID-controlled, up to 450 °C |
| TruZone Active Liquid-Level Control | Yes |
| PowderProtect Anti-Dust System | Yes |
| Stainless Steel Manifold with Pneumatic Valves | Yes |
| Vacuum Integrity Improvement | 38% vs. legacy designs |
| BET Surface Area Detection Limit | 0.01 m²/g (N₂, 77 K) |
| Pore Size Range | 0.35 nm – 500 nm |
| Metal Dispersion Detection Limit | 0.003 m² (H₂ on Pt, 313 K) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Piezo Sample Stage 100 μm × 100 μm |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NHT³ |
| Instrument Type | Nanoindentation Tester |
| Maximum Indentation Depth | 200 µm |
| Effective Load Range | 0.1 mN to 500 mN |
| Load Resolution | 20 nN |
| Load Noise (RMS) | ≤0.5 µN |
| Depth Resolution | 0.01 nm |
| Depth Noise (RMS) | ≤0.15 nm |
| Loading Rate | up to 10,000 mN/min |
| Data Acquisition Rate | 192 kHz |
| Environmental Options | Liquid Testing Compatible |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | NST³ |
| Instrument Category | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 1 µm |
| Load Resolution | 0.01 µN |
| Displacement Range | 600 µm |
| Maximum Friction Force | 1 N |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PoreMaster |
| Price | Upon Request |
| Pore Size Range | 30 nm – 600 µm |
| Pressure Range | 0.01 – 50 MPa |
| Measurement Accuracy | ≤ 0.5% |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Model | iSorb HP |
| Measurement Method | Static Volumetric Method |
| Temperature Range | 75 K to 773 K (-198 °C to 500 °C) |
| Pressure Range | 0.0005 bar to 200 bar (absolute) |
| Ultimate Vacuum | 1×10⁻⁹ mbar |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nova 600BET / 800BET / 600 / 800 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | ≥ 0.01 m²/g (no upper limit) |
| Pressure Range | 1×10⁻⁴ to 0.999 P/P₀ |
| Supported Theoretical Models | BET, Langmuir, t-plot, DFT (NLDFT/QSDFT), BJH, DH, DR, HK, SF |
| Repeatability | < 2% |
| Operating Temperature | 15–35 °C |
| Absolute Pressure Resolution | 1.2×10⁻⁴ Torr |
| Relative Pressure Resolution | 1.5×10⁻⁷ P/P₀ |
| Pore Diameter Range | 0.35–500 nm (0.35–1.1 nm with CO₂ at 273 K) |
| Minimum Detectable Pore Volume | 1.2×10⁻⁸ cm³ |
| Integrated Degassing Stations | 4 (programmable, up to 425 °C) |
| Dewar Capacity | 2 L (up to 40 h operation) |
| Dimensions (D×W×H) | 44 × 63 × 84 cm |
| Weight | 63 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, max. 345 VA |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | STEP x01 |
| Instrument Category | Nanoindentation and Scratch Tester |
| Indenter Tip Material | Diamond |
| Base Platform | Modular Mechanical Surface Testing System |
| Maximum Load Capacity | Not specified in input |
| Compliance | GLP/GMP-ready architecture, ASTM E2546, ISO 14577, ISO 20502, USP <1089> compatible (inferred from platform class) |
| Vibration Isolation | Optional active damping table & acoustic enclosure |
| Microscopy | Dual-view optical microscope (20×–10,000× continuous zoom) |
| Positioning Accuracy | <1 µm over extended scan range |
| Automation Interface | Integrated for factory-floor QC integration |
| Brand | Anton Paar TriTec (formerly CSM Instruments, Switzerland) |
|---|---|
| Origin | Switzerland |
| Model | HIT 300 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Thermal Drift | ≤0.0008 nm/s |
| Frame Stiffness | 10⁸ µN/µm |
| Positioning Accuracy | <1 µm |
| Repeatability | High |
| Compliance | ASTM E2546, ISO 14577, ISO 20519, USP <1089>, GLP/GMP-ready data traceability |
| Brand | Anton Paar TriTec (formerly CSM Instruments, Switzerland) |
|---|---|
| Origin | Switzerland |
| Model | NST³ |
| Instrument Type | Nano Scratch Tester |
| Application Scope | Thin film and coating adhesion, cohesion, scratch resistance, and mechanical integrity assessment for layers < 1 µm thick |
| Key Measurement Capabilities | Critical load (Lc) determination, real-time scratch depth profiling, friction force mapping, elastic recovery quantification, and simultaneous panoramic imaging |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer | Anton Paar GmbH |
| Type | Nanoindentation and Scratch Tester |
| Model | UNHT³ |
| Indentation Depth Range | 0–100 µm |
| Load Range | 10 µN – 100 mN |
| Load Resolution | 3 nN |
| Displacement Resolution | 0.003 nm |
| Thermal Drift | <3 nm/min |
| Frame Stiffness | >10⁸ N/m |
| Compliance with Standards | ISO 14577, ASTM E2546 |
| Brand | Appo |
|---|---|
| Origin | Switzerland |
| Model | MTA03 |
| Load Range | ±200 mN |
| Load Resolution | 0.5 nN |
| Displacement Range | 0.1 nm to 29 mm |
| Displacement Resolution (short-range) | 0.1 nm |
| Displacement Resolution (long-range) | 1 nm |
| Microscope Working Distance | 95 mm |
| Camera | 3 MP CMOS USB |
| Optical Zoom | 7:1 motorized |
| Illumination Options | Coaxial lens, ring light, diffuse backlight |
| Probe Types | Multiple FT-S microforce sensing probes |
| Optional Modules | FT-G microtweezers for microassembly |