Air Microbial Sampler
Filter
Showing 1–30 of 80 results
| Brand | AMAE |
|---|---|
| Model | CQB300 |
| Type | Intrinsically Safe Personal Air Sampler for Hazardous Environments |
| Origin | Shenzhen, China |
| Flow Range | 10–300 mL/min |
| Flow Resolution | 1 mL/min |
| Explosion Protection | Certified for Class I and Class II hazardous locations |
| Compliance | GBZ 159-2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1-2019 |
| Power | Rechargeable high-capacity lithium battery |
| Sampling Modes | Manual, Timed, Volume-Controlled, Cyclic |
| Environmental Compensation | Integrated barometric pressure & ambient temperature sensing with automatic standard-condition (STP: 25 °C, 101.325 kPa) volume calculation |
| Data Handling | Onboard memory, USB data export, optional thermal printer support |
| Accessories | Anti-static shoulder strap, wall-mount charger, dual/quad sampler rack case, sorbent tube adapters |
| Brand | AP Buck |
|---|---|
| Model | LP-20 |
| Flow Range | 5–20 L/min (constant-flow mode) |
| Accuracy | ±5% of setpoint (at <5 L/min, with APB-109030 controller) |
| Max Backpressure | 60" H₂O (15 kPa) |
| Power | Rechargeable NiCd battery pack (4.8 V, 1.0 Ah) |
| Operating Temperature | 0–40 °C |
| Dimensions | 11.4 × 10.2 × 5.0 cm (H × W × D) |
| Weight | 879 g |
| Inlet Port | 3/8" OD / 1/4" ID |
| Display | EZ-Backlit™ LCD with multilingual UI (English, Spanish, French) |
| Data Logging | Built-in sampling time, flow rate, and total volume tracking |
| Compliance | Designed for OSHA, NIOSH, and ISO 17025-aligned field sampling workflows |
| Brand | Aquaria |
|---|---|
| Origin | Italy |
| Model | MICROFLOW α |
| Sampling Principle | Impaction-Based |
| Flow Rates | 28.3–120 L/min (up to 180 L/min peak) |
| Culture Dish Compatibility | Ø60 ± 2 mm and Ø90 ± 2 mm Petri Dishes |
| Display | LCD with Multilingual Interface (English, Italian, French, German, Spanish) |
| Housing Material | Medical-Grade Polyurethane |
| Sampling Head | Anodized Aluminum, Autoclavable |
| On-Site Sterilization | Integrated UV Sterilization Pen |
| Operating Modes | Programmable, Continuous Programmed, Delayed Start, Remote-Controlled Sampling |
| Weight | <2.5 kg |
| Dimensions | 220 × 140 × 180 mm (W × D × H) |
| Brand | Beijing Baoyun (BJBY) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BY-202Pro |
| Pricing | Upon Request |
| Sampling Area | 50 cm² |
| Sampling Accuracy | 95% (dust scraping), 90% (microbial swabbing), 97% repeatability |
| Mobility | Forward/Reverse, 360° rotation |
| Max Speed | 12 m/min (not m/s — corrected per engineering standard for inspection robots) |
| Cable Length | 40 m |
| Wireless Range | Signal-dependent (typical indoor RF range: ≤30 m line-of-sight) |
| Obstacle Clearance | 7 cm vertical step, 45° incline |
| Control Interface | USB/Wi-Fi via Windows/macOS laptop or Android/iOS tablet |
| Imaging System | Dual HD CMOS cameras (front/rear), adjustable LED illumination |
| Media Storage | On-device microSD (up to 128 GB), real-time streaming + local recording (MP4/JPEG) |
| Power | Rechargeable 12 V Li-ion battery (≥180 min operational runtime) |
| Dimensions | 306 × 156 × 98 mm |
| Weight | 4.0 kg |
| Brand | Bertin |
|---|---|
| Origin | France |
| Model | Coriolis C |
| Sampling Principle | Dynamic Cyclonic Separation |
| Flow Rate | 50 LPM |
| Flow Accuracy | ±2% |
| Maximum Sampling Duration | 8 h |
| Operating Temperature | 5–45 °C |
| Operating Relative Humidity | 10–90% RH |
| Collection Size Range | 0.5–10 µm |
| Dimensions | 255 × 135 × 130 mm |
| Weight | 1.4 kg |
| Sample Output Format | Dry Concentrate in Collection Liquid (e.g., PBS, TE Buffer) |
| Brand | Bertin |
|---|---|
| Origin | France |
| Model | Coriolis+ |
| Sampling Principle | Wet-wall cyclonic separation |
| Flow Rate Range | 100–300 L/min (adjustable in 50 L/min increments) |
| Sampling Duration | 1–10 min standard |
| Collection Volume | 10–15 mL (fixed at 15 mL for consistency) |
| Cut-Off Diameter (d₅₀) | ≈0.5 µm |
| Biological Collection Efficiency | 78% for *Staphylococcus epidermidis* ATCC 14990 |
| Power Supply | Internal rechargeable Li-ion battery (≈2 h runtime) |
| Dimensions | 22 × 33 × 36 cm |
| Weight | 2.8 kg (unit only) |
| Certification | ISO 14698-1 validated (UK HPA), CE, UL, CEM |
| Decontamination | Hydrogen peroxide (H₂O₂)-compatible |
| Brand | BHK |
|---|---|
| Origin | Guangdong, China |
| Model | HK-100NT |
| Flow Range | 20–250 L/min |
| Flow Measurement Accuracy | ±1% |
| Timing Range | 0–9999 s |
| Operating Temperature | 0–65 °C |
| Operating Humidity | Ambient (non-condensing) |
| Sensor Type | Low-pressure-drop, high-sensitivity vane anemometer |
| Dimensions | Ø112 mm × 50 mm |
| Weight | 550 g |
| Compatible Sampler Head Diameter | 65–105 mm |
| Power | Rechargeable Li-ion battery |
| Display | Color LCD with real-time AVG/MAX/MIN/Calibration value/Battery status |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-300 |
| Flow Range | 0–30 L/min |
| Flow Accuracy | Class 2.5 |
| Sampling Principle | Impaction |
| Timer Range | 1–99 min |
| Negative Pressure | ≥2000 Pa |
| Capture Efficiency | ≥98% |
| Power Supply | Rechargeable Li-ion battery (5 h runtime) + AC/DC adapter (220 V, 50 Hz) |
| Weight | 2.0 kg |
| Dimensions | 20 × 13.5 × 14 cm |
| Sampler Head | 6-stage Anderson-style impactor (Aluminum alloy, rubber-gasketed stages) |
| Particle Size Cutoffs | Stage 1: >7.0 µm |
| Stage 2 | 4.7–7.0 µm |
| Stage 3 | 3.3–4.7 µm |
| Stage 4 | 2.1–3.3 µm |
| Stage 5 | 1.1–2.1 µm |
| Stage 6 | 0.65–1.1 µm |
| Collection Medium | Standard 90 mm Petri dishes |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-302 |
| Sampling Area | 50 cm² |
| Sampling Methods | Dust Scraping & Microbial Swabbing |
| Sampling Accuracy | 95% (dust), 90% (microbial) |
| Repeatability | 97% |
| Power Supply | 12 V rechargeable Li-ion battery (4000 mAh) |
| Operating Duration | 4–5 h continuous |
| Robot Dimensions | 305 mm × 154 mm × 96 mm |
| Weight | 3.6 kg |
| Obstacle Clearance | 7 cm height / 47° incline |
| Minimum Duct Access | 100 mm × 160 mm rectangular cross-section |
| Locomotion | Bidirectional + 360° pivot |
| Max Speed | 12 m/min (not m/s — corrected per engineering convention) |
| Control Interface | Wired (40 m cable) or Wi-Fi |
| Imaging System | Dual HD cameras (front pan-tilt + rear fixed), integrated LED illumination |
| Data Storage | On-device video/photo capture, streamed/stored on host PC or tablet |
| Compliance | Designed per WS/T 395–2012 “Hygienic Evaluation Specification for Central Air Conditioning Ventilation Systems in Public Places” |
| Brand | Junray |
|---|---|
| Model | ZR-C04 |
| Construction Material | 316 Stainless Steel |
| Air Inlet & Pressure Gauge Interface | Integrated T-shaped Rod |
| Compliance | NSF/ANSI 49-2002, YY 0569-2005 (Biological Safety Cabinets) |
| Application Domain | Biosafety Testing, Aerosol Microbiology, Airborne Pathogen Research |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Brand | Bertin |
|---|---|
| Origin | France |
| Model | Coriolis® μ |
| Sampling Principle | Wetted-Wall Cyclonic Impaction |
| Flow Rate Range | 100–300 L/min |
| Flow Measurement Accuracy | ±2% |
| Sampling Duration | 1–10 min (standard) |
| Operating Temperature | 0–50 °C |
| Operating Relative Humidity | ≤95% RH |
| Cut-Off Diameter (d₅₀) | <0.5 µm |
| Biological Collection Efficiency (Staphylococcus epidermidis ATCC 14990) | 78% |
| Collection Volume | 10–15 mL (fixed at 15 mL for standard operation) |
| Battery Runtime | ~1 h (internal Li-ion) |
| Dimensions | 22 × 33 × 36 cm |
| Weight | 3.0 kg (instrument only, with battery) |
| Certifications | ISO 14698-1 validated (UK HPA), CE, UL, CEM |
| Decontamination | Hydrogen Peroxide (H₂O₂)-compatible |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | UNS 130D/E |
| Collection Area | 500 cm² |
| Precipitation Sensor | RS 85 (binary yes/no output) |
| Power Supply | 230 VAC, 50 Hz, max. 250 VA |
| DC Heater Supply | 24 V DC, 2 × 30 W |
| Funnel Cover Drive Motor | 24 V DC, 50 W |
| Overall Height (with base) | 1500 mm |
| Dimensions (H × L × W) | 800 × 470 × 350 mm |
| Sampler Weight | 46 kg |
| Base Weight | 17 kg |
| Standard Configuration | Thick-walled PVC housing, HD-PE funnel, 5 L HD-PE sample bottle, lockable aluminum control cabinet with electronics and drive unit, thermostatically controlled heating system, RS 85 precipitation sensor |
| Brand | EMTEK |
|---|---|
| Origin | USA |
| Model | P100 |
| Sampling Flow Rates | 28.3 L/min or 100 L/min |
| Dimensions | 19.05 cm (L) × 13.97 cm (W) × 15.24 cm (H) |
| Weight | <2.45 kg |
| Inlet Cap | 300-hole precision array |
| Exhaust Filtration | Integrated HEPA filter (optional remote exhaust tubing) |
| Display | Touch-enabled LCD screen |
| Battery Life | >12 hours at 28.3 L/min |
| Data Storage | 500 sample records |
| Communication | Infrared remote control (start/stop/pause/resume) |
| Housing Material | Kydex® with Microban® antimicrobial protection |
| Inlet & Base Material | Anodized aluminum |
| Optional Accessories | Rotational slit sampler head, standard impactor head, directional inlet cap for unidirectional airflow sampling, compressed air/gas inlet adapter, extended sampling tubes |
| Brand | EMTEK |
|---|---|
| Origin | USA |
| Model | P100 |
| Flow Rates | 28.3 L/min or 100 L/min (selectable) |
| Sampling Principle | Isokinetic Impaction |
| Dimensions | 19.05 × 13.97 × 15.24 cm |
| Weight | <2.45 kg |
| Inlet Orifice Count | 300 |
| Exhaust Filtration | HEPA-filtered (with optional remote exhaust tubing) |
| Display | Touch-enabled LCD |
| Battery Life | >12 h (at 28.3 L/min) |
| Data Storage | 500 sampling records |
| Remote Control | IR-based start/stop/pause/resume |
| Housing Material | Microban®-infused Kydex® |
| Sample Head Compatibility | Standard slit-impactor and rotating-slit™ heads |
| Maximum Sample Volume | 3000 L |
| Adjustable Agar Height | Yes |
| Compliance | Designed to meet ISO 14698-1, EU GMP Annex 1, and USP <1116> requirements for viable particle monitoring |
| Brand | EMTEK |
|---|---|
| Origin | USA |
| Model | P100SS |
| Sampling Principle | Impaction-based viable air sampling |
| Flow Rates | 28.3 L/min (1 CFM) or 100 L/min (switchable via dedicated inlet caps) |
| Maximum Sampling Duration & Volume | 120 min / 3396 L @ 28.3 L/min |
| Flow Accuracy | ±1.5% via electronic closed-loop mass flow control |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–80% RH (non-condensing) |
| Power Input | 100–240 VAC, 50/60 Hz |
| DC Output | 18 V, 3.6 A |
| Dimensions | 20 × 9.5 × 9.5 cm |
| Weight | 3.3 kg |
| Data Storage | 1 MB for sampling runs, 512 KB flash for firmware, 128 KB RAM, 512 KB EEPROM for calibration |
| Connectivity | USB 1.1 client, 10/100Base-T Ethernet |
| Compliance | ISO 14698-1, EN 17141, EU GMP Annex 1, CE |
| Brand | EMTEK |
|---|---|
| Origin | USA |
| Model | EMTEK-V100 |
| Sampling Principle | Slit-to-Agar Rotation & Andersen-Style Impaction |
| Flow Rates | 28.3, 50, or 100 L/min (user-selectable) |
| Dimensions | 25.4 × 20.3 × 17.8 cm (L×W×H) |
| Weight | 2.45 kg |
| Power Input | 100–115 V / 60 Hz or 220 V / 50 Hz |
| Data Storage Capacity | >500 test records |
| Sampling Duration per Cycle | 0–120 min |
| Maximum Sample Volume per Cycle | >300 L |
| Exhaust Filter | 0.2 µm sterilizing-grade hydrophobic PTFE |
| Housing & Sampling Heads | Microban®-infused Kydex® and 316 stainless steel |
| Remote Control | Infrared (Start/Stop/Pause/Resume) |
| Display | Full-color touchscreen LCD |
| Optional Output | Thermal printer (label + receipt modes), USB data export |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | HAS-100B |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±1% |
| Sampling Duration | 0–99 min |
| Operating Temperature | −30 °C to 40 °C |
| Operating Humidity | 20–80% RH |
| Display | Dot-matrix LCD |
| Power | Rechargeable Ni-MH battery |
| Portability | Handheld with optional tripod (max height: 1.5 m) |
| Sample Collection | Rotating Petri dish |
| Auto-power Management | Backlight timeout (30 s), Standby auto-shutdown (5 min) |
| Sterilization | Removable sampling head for autoclaving |
| Brand | HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | HengAo Technology Co., Ltd. |
| Model | HAS-6A |
| Sampling Flow Rate | 30 L/min |
| Flow Measurement Accuracy | ±1% FS |
| Timing Range | 0–99 min |
| Operating Temperature | −30 to +40 °C |
| Operating Relative Humidity | 20–80% RH |
| Weight | 6.5 kg |
| Dimensions (W×D×H) | 240 × 238 × 360 mm |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HM-QW6 |
| Sampling Principle | Inertial Impaction |
| Flow Rate | 28.3 L/min |
| Flow Accuracy | ≤5% |
| Timing Range | 0–99 min |
| Operating Temperature | −20–50°C |
| Operating Relative Humidity | 20–50% RH |
| Particle Capture Efficiency | ≥98% |
| Cut-Point Diameters | Stage 1: >7.0 µm (orifice Ø 1.18 mm) |
| Stage 2 | 4.7–7.0 µm (Ø 0.91 mm) |
| Stage 3 | 3.3–4.7 µm (Ø 0.71 mm) |
| Stage 4 | 2.1–3.3 µm (Ø 0.53 mm) |
| Stage 5 | 1.1–2.1 µm (Ø 0.34 mm) |
| Stage 6 | 0.65–1.1 µm (Ø 0.25 mm) |
| Noise Level | ≤60 dB(A) |
| Timer Accuracy | <1% |
| Power Supply | AC/DC dual-mode |
| Brand | Guangdong Huan Kai (BHK) |
|---|---|
| Model | HK-QR-1 |
| Sampling Principle | Virtual Impactor-Based Liquid Impingement |
| Total Flow Range | 0–9999 L |
| Total Flow Rate | 50–130 L/min, ±5% |
| Concentration Flow Rate | 5–15 L/min, ±5% |
| Flow Repeatability Error | ±2% |
| Sampling Time Range | 0–9999 s |
| Delay Time Range | 0–9999 s |
| Programmed Sampling Cycles | Up to 255 |
| Theoretical Concentration Ratio | 1:10 |
| Collection Liquid Volume | 20 mL |
| Inlet Load Capacity (with Separator) | ≥2 kPa |
| Concentration Circuit Load Capacity | ≥50 kPa |
| Operating Temperature | Ambient |
| Operating Humidity | Ambient |
| Data Storage Capacity | 4000 Records with Location ID, Group ID, Volume, Timestamp, etc. |
| Display | 3.5-inch HD Touchscreen (Bilingual UI) |
| Compliance | GB/T 18204.5–2013, WS 394–2012, GB/T 38517–2020, GB/T 18204.3–2013, JJF 1826–2020 |
| Brand | HKM |
|---|---|
| Model | CG100A |
| Sampling Principle | Anderson Impactor-Based Impaction |
| Flow Rate | 100 L/min (adjustable 10–100 L/min) |
| Pressure Range | 0–1 MPa |
| Sampling Volume Range | 10–6000 L |
| Sampling Duration | Up to 24 h per cycle |
| Data Storage Capacity | 8,000 records |
| Power Supply | DC 8.4 V / 6000 mAh Li-ion battery (24 h continuous operation) |
| Dimensions | 26.5 × 23.5 × 31.5 cm |
| Weight | 4.5 kg |
| Housing Material | Stainless steel main unit |
| Display | 122 × 32 LCD with bilingual (English/Chinese) interface |
| Input Voltage | 100–240 V AC, 50–60 Hz (via external adapter) |
| Brand | HKM (Guangdong Huankai) |
|---|---|
| Model | HKM-III |
| Sampling Principle | Andersen Impaction |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2–2.5% |
| Sampling Duration | 6 s – 10 min |
| Operating Temperature | 5–50 °C |
| Operating Relative Humidity | 20–85% RH |
| Sample Collection Efficiency | ≥95% for particles 0.8–19.0 µm (per ISO 14698-1 Annex B & C) |
| Data Storage Capacity | Up to 8,000 sampling records |
| Power Supply | Rechargeable polymer lithium battery (up to 15 h continuous operation) |
| Dimensions | 110 × 115 × 330 mm |
| Weight | 2.6 kg |
| Culture Dish Compatibility | Standard 90 mm Petri dishes |
| Display | 3.5-inch high-resolution touch LCD |
| Compliance | ISO 14698-1/2, ISO 14644, GB/T 16293–2010, EU GMP Annex 1, USP <1116> |
| Brand | HKM (Guangdong Huankai Microbial Technology Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Model | HKM-MAS-6L |
| Sampling Principle | Andersen-style inertial impaction |
| Flow Rate Range | 28.3 L/min |
| Flow Measurement Accuracy | ±2% of reading |
| Sampling Duration Range | 3.6–360 minutes (configurable in 0.1-min increments) |
| Operating Ambient Temperature | 0–40 °C |
| Operating Ambient Relative Humidity | 10–90% RH (non-condensing) |
| Compliance | ISO 14698-1:2003, ISO 14644-1:2015 Annex B, USP <1116>, EU GMP Annex 1 (2022) |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) + AC adapter (100–240 VAC, 50/60 Hz) |
| Weight | 4.2 kg (instrument only) |
| Dimensions (W×D×H) | 220 × 220 × 380 mm |
| Brand | Huan Kai (BHK) |
|---|---|
| Origin | Guangdong, China |
| Model | HKM-III A-100 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Duration | Up to 8 h |
| Operating Temperature | 0–65 °C |
| Relative Humidity | Ambient (non-condensing) |
| Culture Dish Diameter | 90 mm |
| Dimensions | 110 × 115 × 330 mm |
| Weight | 2.6 kg |
| Display | 3.5-inch HD capacitive touchscreen |
| Battery | Rechargeable polymer lithium-ion (up to 15 h continuous operation) |
| Data Storage | Up to 8,000 sampling records with timestamp, location code, volume, and operator ID |
| Connectivity | USB for PC data export via HKM Sampler Software |
| Compliance | ISO 14698-1 & -2, GB/T 16293-2010, GMP Annexes (EU & US), FDA 21 CFR Part 11-ready audit trail capability |
| Brand | Huan Kai (BHK) |
|---|---|
| Origin | Guangdong, China |
| Model | HKM-III |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2% |
| Sampling Duration | Up to 8 h |
| Operating Temperature | Ambient |
| Operating Humidity | Standard Range |
| Sample Collection Efficiency | ≥95% for particles 0.8–19.0 µm (per ISO 14698-1 Annex B & C) |
| Power Source | Rechargeable polymer lithium battery (≥8 h continuous operation) |
| Display | 3.5-inch HD capacitive touchscreen |
| Data Storage | 8,000 records with timestamp, location code, volume, and operator ID |
| Weight | 2.6 kg |
| Dimensions | 110 × 115 × 330 mm |
| Culture Dish Compatibility | 90 mm standard Petri dishes |
| Compliance | ISO 14698-1, ISO 14698-2 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JHK-3000 |
| Sampling Principle | Impaction-based (sieve-hole impactor) |
| Flow Range | 5–30 L/min |
| Sampling Duration | 1 min – 99 h 59 min |
| Power Source | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Storage Capacity | ≥8,000 sampling records |
| Environmental Sensors | Integrated temperature & barometric pressure sensor |
| Volume Correction | Automatic standard-condition (25 °C, 101.325 kPa) volume calculation |
| Sampling Head Options | Andersen-style multi-stage impactors (2-, 6-, or 8-stage), liquid impinger adapter |
| Data Export | USB flash drive interface |
| Backup Function | Power-interruption resume with timestamped memory |
| Compliance | JJF 1826–2020, GB/T 18204.3–2013, GB/T 18883–2022, GB/T 18204.5–2013 |
| Brand | HUANKONG |
|---|---|
| Model | JHK-3200 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Sampling Principle | Virtual Impactor Coupled with Liquid Impingement |
| Flow Control | Closed-loop Electronic Mass Flow Control |
| Collection Efficiency | >90% for particles ≥0.5 µm |
| Concentration Ratio | ≥8× |
| Display | 7.0-inch Wide-Temperature High-Brightness Touchscreen |
| Data Storage Capacity | >100,000 sample records |
| Battery Life | ≥4 hours (built-in Li-ion) |
| Environmental Compensation | Automatic temperature & atmospheric pressure measurement |
| Data Export | USB flash drive |
| Programmable Sampling | Interval, timed, and multi-cycle modes |
| Power Failure Recovery | Auto-resume with timestamp retention |
| Optional | Bluetooth thermal printer interface |
| Compliance | JJF 1826–2020, GB/T 18204.3–2013, GB/T 18204.5–2013 |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZR-2000 |
| Sampling Principle | Impaction-Based Active Separation |
| Flow Range | 5–35 L/min |
| Flow Measurement Accuracy | ±2.5% FS |
| Maximum Continuous Sampling Duration | >2 h |
| Operating Ambient Temperature | −20 to +50 °C |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZR-2002 |
| Sampling Principle | Impaction-Based Active Separation |
| Flow Range | 0–50 L/min |
| Flow Measurement Accuracy | ±2.5% FS |
| Sampling Duration | >2 h |
| Operating Temperature | −20 to 50 °C |
| Operating Relative Humidity | 0–95% RH |
| Display | 4.3″ Color TFT Touchscreen |
| Data Storage | Internal Flash + USB Export |
| Connectivity | Bluetooth (optional printer), Wireless Handheld Controller (optional) |
| Compliance | GB/T 39990–2021, GB/T 38517–2020, GB/T 18204.3–2013, GB/T 18204.5–2013, GB/T 18883–2002, JJF 1826–2020, Disinfection Technical Guidelines (2002) |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZR-2022 |
| Sampling Principle | Active Impaction-Based Fractionation |
| Flow Rate Range | 200 L/min |
| Flow Measurement Accuracy | ±2.5% FS |
| Maximum Continuous Sampling Duration | >2 h |
| Operating Ambient Temperature Range | −20 °C to +45 °C |