Electromagnetic Compatibility Test System
Filter
Showing all 12 results
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | EEDs |
| Pricing | Available Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 1000 |
| Processor | Motorola DSP56002 & Intel 80C186/187 |
| Input Resolution | 18-bit per channel |
| ADC Interface | IEEE-488 (GPIB) |
| Self-test | On power-up |
| Power Supply | 180–250 VAC / 90–125 VAC, 50–60 Hz |
| Max Power Consumption | 40 W |
| Dimensions | 460 × 448 × 132 mm |
| Weight | 12 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–80 °C |
| Storage Humidity | ≤92% RH, non-condensing |
| Software Platform | Windows-based |
| Harmonic Standards Compliance | IEC 61000-3-2, IEC 61000-3-4, IEC 61000-4-7, IEC 555-2 |
| Flicker Standards Compliance | IEC 61000-3-3 (replaces IEC 1000-3-3), IEC 60468 (Amend. 1), IEC 60555-3 (Amend. 1), IEC 60868 (Amend. 1) |
| Voltage Input Range | 90–300 Vrms (flicker: 40–504 Vrms) |
| Current Input Range | 5 mA–16 A (shunt ranges: 0.16 / 0.8 / 4 / 20 A) |
| Voltage Channel Input Impedance | >8 MΩ |
| Current Channel Impedance | <3.03 mΩ (max range) |
| Max Potential Difference | 150 mV |
| Accuracy | Better than ±0.2% for harmonics |
| Anti-aliasing Filter Attenuation | 70 dB |
| Transient Harmonic Smoothing | Low-pass filter, 1° phase shift (1.5 s period) |
| Measurement Modes | Single-shot, time-limited, continuous |
| Data Storage | Ring-buffer architecture retaining last 2.5 minutes of continuous measurement |
| FFT Points | 2048 |
| Frequency Range | 45–65 Hz (extendable to 16–2500 Hz) |
| Flicker Metrics | Pst, Plt, Pmax, P50%, P10%, P3%, P1%, P0.1%, CPF, d(t), dmax, dc |
| Voltage Fluctuation Resolution | ±2% error for d(t) and dmax |
| AC Power Supply Options | TPS 1500 (1-phase, 1.5 kVA), TPS-K10 (3-phase, 10 kVA), TPS-K20 (3-phase, 20 kVA) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 1008 |
| Generator Output | 160 A (continuous), 1200 A (transient) |
| Continuous Field Levels | 1–100 A/m (IEC/EN 61000-4-8 Classes 1–5) |
| Transient Field Levels | 300–1000 A/m |
| Coil Dimensions | 1.035 m × 1.035 m × 35 mm |
| Antenna Factor | 0.87 |
| Coil Inductance | ~0.6 µH |
| Coil Resistance | 670 µΩ |
| Generator Dimensions (W×D×H) | 385 × 215 × 400 mm |
| Generator Weight | 28 kg |
| Coil + Trolley + Stand Total Weight | 50 kg |
| Power Supply | 198–264 V AC, 50/60 Hz |
| Interface | RS232/RS485 (DB9) |
| Safety | Interlock-enabled, thermal cutoff, ≤4 Vrms open-circuit voltage |
| Compliance | IEC/EN 61000-4-8, EU Directives 89/336/EEC & 73/23/EEC |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 6000A |
| RF Signal Source | PMM 3010 |
| Power Amplifier Options | PMM 5042 or 7034 |
| Power Meter | PMM 6630 |
| Current Injection Clamp | OIP400 |
| Injection Current Capability | 200 mA, 300 mA, and 400 mA (peak) |
| Software | PIMS (Programmable Immunity Measurement System) |
| Hardware Architecture | Decentralized modular design |
| Instrument Interoperability | Compatible with R&S SMB100 series signal sources and third-party amplifiers/clamps per ISO 11452-4 |
| Compliance | Designed for ISO 11452-4, ISO 10605, SAE J1113/4, and CISPR 25 immunity validation |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 6000C |
| Compliance Standards | IEC 61000-4-6, GB/T 17626.6 |
| Calibration Levels | 1 V, 3 V, and 10 V (per IEC 61000-4-6 Annex A) |
| Core Components | PMM 3010 RF Signal Generator, PMM 6000N/5048FE Power Amplifier, M3-16 Coupling/Decoupling Network (CDN), ATT-25W Attenuator, SW-06 Control & Calibration Software, Cab-06 Interconnection Cables |
| Optional Accessories | M-, AF-, S-, and T-type CDNs |
| Amplifier Upgrade Range | 15 W to 10,000 W |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | 6000R |
| Pricing | Available Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 7000 |
| Frequency Range | 150 kHz – 1 GHz |
| Input A (Conducted) | 150 kHz – 30 MHz, 50 Ω BNC |
| Input B (Radiated) | 30 MHz – 1 GHz, 50 Ω N-type |
| Built-in LISN | 2 × 16 A, 50 Ω/50 µH |
| VSWR | <1.2 (≥10 dB attenuation), <2 (≥0 dB attenuation) |
| Max Input | <127 dBµV (sinusoidal AC) |
| Detectors | Peak, Quasi-Peak, Average (hardware-based) |
| Measurement Uncertainty | ±2 dB (150 kHz–30 MHz), ±2–3 dB (30–300 MHz), ±2–4 dB (300–1000 MHz) |
| Display Units | dBµV, dBµV/m, dBpW |
| IF Bandwidths | 9 kHz / 120 kHz (CISPR-compliant) |
| AM/FM Demodulation Module | Integrated with headphone output |
| Dimensions | 364 × 120 × 376 mm |
| Weight | 5 kg |
| Operating Temperature | 5–40 °C |
| Power Supply | 115/230 VAC ±10%, 50/60 Hz, max. 30 VA |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9010 + 9030 |
| Frequency Range | 10 Hz – 3 GHz |
| Detection Modes | Peak (PK), Quasi-Peak (QP), Average (AVG), RMS |
| Interface | RS-232, Bluetooth (optional), High-Speed Optical Fiber (≥2.5 GB/s) |
| Compliance | CISPR 16-1-1, CISPR 16-2-3, MIL-STD-461G, EN 55032/55035, IEC 61000-4-3 |
| Built-in Signal Generator | 10 Hz – 50 MHz, programmable output |
| Scalar Network Analysis Capability | Yes |
| Real-Time FFT Processing | Yes |
| Internal Memory | High-capacity embedded storage |
| Preselector | Integrated analog preselector with pulse-handling capability |
| Digital LO Architecture | Fully synthesized complex digital IF local oscillator |
| Adaptive RF Attenuation | FPGA-controlled, DSP-driven automatic gain control |
| Click Analyzer | Optional (1-channel internal, 3-channel external) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9010 |
| Frequency Range | 10 Hz – 30 MHz (expandable to 3 GHz / 6 GHz) |
| Weight | 4 kg (main unit) |
| Power Supply | DC battery-operated (integrated Li-ion) |
| Compliance | Fully compliant with CISPR 16-1-1:2023, EN 55016-1-1, MIL-STD-461G, DO-160G, FCC Part 15/18 |
| Calibration Architecture | Fully digital signal path with built-in RF self-calibration source |
| Detection Modes | Peak, Quasi-Peak, Average, RMS, CISPR-Average, CISPR-RMS |
| RBW Filters | Digital implementation per CISPR 16-1-1 (200 Hz, 9 kHz, 120 kHz, 1 MHz) |
| Software Control | Native Narda STS EMCO software |
| Module Architecture | Pre-calibrated hot-swap functional modules (e.g., click noise analyzer, LISN interface, near-field probes) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM CA0010 |
| Frequency Range | 150 kHz – 30 MHz |
| Frequency Accuracy | ±100 Hz |
| Amplitude Range | 20 dBµV – 95 dBµV |
| Amplitude Accuracy | ±0.1 dB |
| Pulse Rise Time | ≥100 µs |
| Pulse Interval | ≥100 µs |
| Time Step Resolution | 10 µs |
| Pulse Repetition Rate | 1 Hz – 500 Hz |
| Repetition Rate Accuracy | ±1 Hz |
| Amplitude Flatness | ≤1.8 dB (150 kHz – 30 MHz) |
| Amplitude Resolution | 0.1 dB |
| Max Input Level | 140 dBµV (2 W) |
| Built-in LISN | Single-phase, 16 A, compliant with CISPR 16-1-2 (150 kHz – 30 MHz) |
| RF Connector | BNC (F) |
| Operating Temperature | −5 °C to +45 °C |
| Dimensions | 235 mm × 105 mm × 335 mm |
| Weight | 4.1 kg |
| Standards Compliance | CISPR 16-1-1, CISPR 16-1-2, CISPR 14-1 |
| Dynamic Range Enhancement | Integrated preselector |
| Signal Generation Capabilities | CW, click, and CISPR pulse signals |
| Software Resolution | 500 µs QP detection, full IF bandwidth display |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | FR4003 |
| Frequency Range | 9 kHz – 30 MHz |
| Frequency Resolution | 1 Hz |
| Frequency Accuracy | ±1 ppm |
| Internal Attenuation | 0–30 dB (10 dB steps) |
| Preamp Gain | 20 dB |
| Field Strength Limit | 500 V/m (CW, ATT ≥ 20 dB) |
| Noise Floor | 13 dBμV/m (peak), 2 dBμV/m (average) |
| Spurious Response Suppression | < −10 dBμV (ATT = 0 dB, avg, dwell time 10 ms, auto RBW, 50 Ω port) |
| Measurement Accuracy | ±0.8 dB |
| Compliance | CISPR 16-1-1, CISPR 12/16/25, MIL-STD-461, DO-160 |
| Brand | PMM |
|---|---|
| Model | XC 9010 |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Pricing | Upon Request |