| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | OsmoTECH HT |
| Pricing | Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Advanced Instruments, Inc. |
| Product Category | Imported |
| Model | OsmoTECH PRO |
| Pricing | Available Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | OsmoTECH |
| Pricing | Available Upon Request |
| Brand | Advanced Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | OsmoTECH XT |
| Price | Upon Request |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | 2020 |
| Principle | Freezing Point Depression |
| Sample Capacity | 20 positions |
| Sample Volume per Test | 20 µL |
| Test Time | ≤90 s per sample |
| Data Storage | ~30 test results |
| Output Interface | Parallel port |
| Printer | Integrated vertical thermal printer |
| Time/Date Stamp | Yes |
| Barcode Reader | Optional |
| Statistical Functions | Mean, SD, CV |
| Software Upgradability | Yes |
| Language Support | Multilingual (English, Spanish, French, German, Chinese) |
| Brand | Gonotec |
|---|---|
| Origin | Germany |
| Model | OSMOMAT 3000 |
| Measurement Range | 0–3000 mOsmol/kg |
| Sample Volume | 50 µL (15 µL with optional micro-sampling module) |
| Measurement Time | ~60 s per sample |
| Calibration Options | 10 standard points (100–2500 mOsmol/kg) |
| Display | 5.7" TFT LCD touchscreen |
| Language Support | English, German, Chinese (user-selectable dual-language mode) |
| Compliance | Chinese Pharmacopoeia General Chapter 0632 |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-STY1 |
| Price | USD 4,500 (FOB) |
| Measurement Principle | Cryoscopic Depression of Freezing Point |
| Compliance | JJG 1089–2013, Chinese Pharmacopoeia 2025, ISO 17511 (traceability framework), USP <785> |
| Detection Speed | Up to 50 samples/h |
| Range | 0–3000 mOsmol/kg |
| Sample Volume | 50–100 µL |
| Resolution | 0.005 mOsmol/kg |
| Accuracy | ±6 mOsmol/kg (≤400) or ±1.5% (>400) |
| Repeatability | ≤2 mOsmol/kg (≤400) or CV ≤0.75% (>400) |
| Stability | ≤2 mOsmol/kg (at 300 mOsmol/kg, 8-h drift) |
| Cooling Time | ≤5 min |
| Operating Environment | 5–35°C, 5–80% RH (non-condensing), <2000 m altitude |
| Dimensions (D×W×H) | 360 × 300 × 240 mm |
| Weight | 7 kg |
| Data Interface | USB 2.0, 10/100 Mbps Ethernet, Wi-Fi 802.11 b/g/n, optional 4G LTE |
| Onboard Printer | Thermal, 57 mm paper roll |
| Power Input | 100–277 VAC, 50/60 Hz, 220 W max |
| Brand | Herolab |
|---|---|
| Model | OSMO 3000 |
| Measurement Principle | Freezing Point Depression |
| Measurement Range | 0–3000 mOsmol/kg |
| Resolution | 1 mOsmol/kg |
| Sample Volume (Standard) | 30–50 µL |
| Sample Volume (Optional M Kit) | 15 µL |
| Measurement Time | ~60 s |
| Repeatability | ≤ ±2 mOsmol/kg (0–400), ≤ ±0.5% (400–1500), ≤ ±1% (1500–3000) |
| Calibration Options | 2-point or 3-point |
| Cooling System | Dual independent Peltier modules with electronic temperature monitoring |
| Display | 5.7″ LCD touchscreen |
| Data Interfaces | 2 × RS232, 1 × USB |
| Power Supply | 220 V (±20 V), 50–60 Hz, 120 VA |
| Dimensions (W×H×D) | 220 × 205 × 360 mm |
| Weight | ~6.5 kg |
| Operating Environment | 10–35 °C |
| Compliance | Chinese Pharmacopoeia General Chapter 0632 |
| Brand | KNAUER |
|---|---|
| Origin | Germany |
| Model | K-7400S |
| Measurement Principle | Cryoscopic Depression of Freezing Point |
| Compliance | European Pharmacopoeia 2.2.35 (01/2012) |
| Cooling System | Peltier-based Thermoelectric Cooler |
| Control | Integrated Microprocessor with Automated Cycle Management |
| Software Interface | EuroOsmo 7400 (Windows-compatible, supports audit trail, calibration logging, and data export in CSV, TXT, PDF formats) |
| Optional Peripherals | Thermal Printer, RS-232/USB Communication Module |
| Brand | KNAUER |
|---|---|
| Origin | Germany |
| Model | K-7400S |
| Measurement Principle | Cryoscopic Depression (Freezing Point Depression) |
| Sample Volume | 50–150 µL |
| Measurement Time | ~2 min per sample |
| Compliance | Ph. Eur. 2.2.35 (01/2012), USP <785>, ChP 2015 Edition, ISO/IEC 17025 applicable |
| Software | EuroOsmo-CN (21 CFR Part 11 compliant with audit trail, electronic signature, role-based access control) |
| Cooling System | Peltier-based thermoelectric cooling |
| Data Export Formats | PDF, Excel (.xlsx), CSV, TXT |
| Optional | Thermal printer integration |
| Validation Support | IQ/OQ documentation available |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FPOSM-2.0 |
| Measurement Principle | Cryoscopic Depression (Ice Point Depression) |
| Measurement Range | 0–3000 mOsm/kg H₂O |
| Sample Volume | 50–70 µL |
| Pre-cooling Time | ≤3 min |
| Test Time | <2 min |
| Accuracy | ±1% (≤300 mOsm/kg and ≥400 mOsm/kg) |
| Repeatability (RSD) | ≤±1% at 300 mOsm/kg |
| Resolution | 1 mOsm/kg H₂O |
| Linearity | <1% (linear fit) |
| Calibration Points | 31-point programmable calibration (2-point or multi-point linear correction supported) |
| Display | Full-color LED LCD |
| Data Storage | 20,000 test records with recall & print capability |
| Built-in Pharmacopoeia Database | Preloaded Chinese Pharmacopoeia (2010 Edition) injection names |
| Cooling System | Dual-stage semiconductor refrigeration, refrigerant-free thermal transfer design |
| Compliance | Fully compliant with Chinese Pharmacopoeia (2010 Edition), USP <785>, and ISO 17511:2020 (in vitro diagnostic medical devices — requirements for establishing metrological traceability of values assigned to calibrators and human samples) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FPOSM-V2.0 |
| Measurement Range | 0–2000 mOsm/kg H₂O |
| Sample Volume | 100 µL |
| Analysis Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤±1% |
| Repeatability | ≤1% |
| Linearity | ≤1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% RH |
| Power Supply | 220 V AC, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Cooling System | Dual-stage thermoelectric (no heat-transfer fluid) |
| Display | 7-inch color capacitive touchscreen |
| Data Storage | 3-year audit-trail compliant archive with timestamped records |
| Calibration | Up to 31-point linear calibration |
| Regulatory Support | CFR 21 Part 11–compatible electronic signatures, user-level access control, GLP/GMP-ready data management |
| Brand | NeuronBC |
|---|---|
| Model | FPOSM-V2.0 |
| Measurement Principle | Freezing Point Depression (based on Raoult’s Law) |
| Measurement Range | 0–2000 mOsmol/kg |
| Sample Volume | 100 µL |
| Analysis Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤±1% |
| Repeatability | ≤±1% |
| Linearity | ≤±1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% RH |
| Power Supply | 220 V AC, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Compliance | Designed to support 21 CFR Part 11-compliant data integrity requirements (electronic signatures, user-level access control, audit-trail-ready data storage) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FPOSM-V2.0 |
| Measurement Range | 0–2000 mOsmol/kg |
| Sample Volume | 100 µL |
| Test Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤1% |
| Repeatability | ≤1% |
| Linearity | ≤1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% |
| Power Supply | 220 V, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FPOSM2.0 |
| Measurement Principle | Freezing Point Depression (based on Raoult’s Law) |
| Measurement Range | 0–2000 mOsmol/kg |
| Sample Volume | 100 µL |
| Test Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤1% |
| Repeatability | ≤1% |
| Linearity | ≤1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% |
| Power Supply | 220 V AC, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Compliance | Designed to support 21 CFR Part 11-compliant data integrity requirements (electronic signatures, user-level access control, audit-trail-capable data storage) |
| Key Features | Microprocessor-controlled cryoscopic measurement |
|---|---|
| Sample volume | 30–50 µL (optional 15 µL configuration) |
| Measurement time | <60 s per sample |
| Accuracy | ±0.5% or ±2 digits (at 50 µL), ±1% or ±4 digits (at 30 µL) |
| Resolution | 1 mOsmol/kg |
| Measuring range | up to 3000 mOsmol/kg |
| Cooling system | Dual independent Peltier elements with electronic temperature regulation (±0.1 °C stability) |
| Display | 4½-digit LED |
| Dimensions | 220 W × 205 H × 360 D mm |
| Weight | 7 kg |
| Power supply | 110/230 V, 50/60 Hz |
| Compliance | Designed for GLP/GMP-aligned pharmaceutical QC environments |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg), ±1% (>400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Regulatory Status | Certified Medical Device per Chinese NMPA Class II requirements |
| Compliance | Meets pharmacopoeial specifications in Chinese Pharmacopoeia (2020 Edition), including for injectables, ophthalmic preparations, and osmotic diuretics |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C-1 |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–70 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤ 400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Ambient Temp. | 10–30 °C |
| Ambient Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Dimensions | 220 × 210 × 360 mm |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30D |
| Measurement Principle | Freezing Point Depression |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Analysis Time | < 90 s |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 10–30 °C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Compliance Support | Chinese Pharmacopoeia (ChP) injection database built-in |
| Data Interface | RS232 |
| Software Features | User permission management, audit-trail-capable data storage, configurable pass/fail criteria, multi-format print output |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30DS |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Analysis Time | < 1.5 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FD |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Capacity | 1–20 positions |
| Sample Volume | 60 µL (50–100 µL typical) |
| Test Time | < 1.5 min per sample |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 5–35°C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Dimensions | 280 × 443 × 434 mm |
| Language Support | English & Chinese |
| Connectivity | RS232, USB, Barcode Scanner Interface |
| Compliance | Designed to support pharmacopeial testing per Chinese Pharmacopoeia (ChP) requirements |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FS |
| Measurement Principle | Freezing Point Depression |
| Temperature Control System | Dual-stage Peltier Cooling |
| Sample Volume | 50–100 µL |
| Calibration | Multi-point, User-defined Calibration Curves |
| Operating System | Android-based Embedded OS |
| Data Storage | Internal SSD with >100,000 Test Record Capacity |
| Compliance Features | Audit Trail, Electronic Signature (21 CFR Part 11 Ready), Role-Based Access Control |
| Connectivity | RS232, USB Host (for keyboard/mouse/scanner), Built-in Thermal Printer |
| Noise Level | <45 dB(A) |
| Pharmacopeia Integration | Preloaded Chinese Pharmacopoeia (ChP) Monographs for >300 Injectable Products |
| Maintenance | Dry-Cooling Architecture (No Heat Transfer Fluid Required) |
| Brand | TJtianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SMC 30F |
| Pricing | Available Upon Request |
| Brand | UIC (United Instruments Corporation) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MODEL 833 |
| Price | USD 18,200 (FOB US port, ex-works pricing basis) |