| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 201/525 |
| Instrument Type | Ultraviolet-Visible (UV-Vis) Detector |
| Noise | < ±1.0 × 10⁻⁵ AU @ 254 nm |
| Wavelength Range | 190–800 nm |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Precision | ±1.0 nm |
| Optical Design | Single-Wavelength (201) / Dual-Wavelength (525) |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ASP660L |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automatic |
| Desorption Zone Temperature Range | 0–45 °C |
| Valve Injection Zone Temperature | Ambient |
| Transfer Line Temperature | Ambient |
| Cold Trap Temperature | 0 °C |
| Temperature Control Accuracy | ±0.5 °C (at ambient) |
| Analyte Recovery Rate | ≥95% |
| Sample Position Capacity | 6 |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Two-stage Thermal Desorber |
| Desorption Temperature Range | 50–380 °C |
| Valve Inlet Temperature Range | 50–220 °C |
| Transfer Line Temperature Range | 50–220 °C |
| Cryo-Focusing Trap Temperature Range | −18 to 320 °C |
| Sample Positions | 30 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 502 |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation/Emission Wavelengths | Dual-Programmable |
| Spectral Range | Broad (Typical UV-Vis, e.g., 200–700 nm) |
| Bandwidth Options | Multiple Fixed and Variable Slit Widths |
| Sensitivity | High (Sub-picomolar Detection Limit for Standard Fluorophores) |
| Noise Level | Ultra-Low (RMS < 0.5 mV at 1 s time constant) |
| Scan Mode | Point-Scan Fluorescence Acquisition |
| Spectral Storage Capacity | ≥64 Predefined Method-Linked Spectral Profiles |
| Dynamic Range | >4 Orders of Magnitude (Linear Response from 10⁻¹² to 10⁻⁸ M for quinine sulfate equivalent) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 6000 |
| Instrument Type | Ultraviolet-Visible (UV-Vis) Diode Array Detector |
| Detection Limit | 0.1 µg/L (typical, based on caffeine in methanol/water, 254 nm) |
| Precision | ≤0.2% RSD (retention time and peak area, n=6) |
| Flow Rate Compatibility | 1 µL/min to 20 mL/min |
| Optical Path Length | 50 mm LightPipe flow cell (patented) |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ACQ-06 |
| Pricing | Available Upon Request |
| Instrument Type | Liquid Chromatography Column Switching Module |
| Fluidic Path Materials | SS316L, PTFE, ETFE, PEEK |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi AGS-36 |
| Valve System | 6-port rotary valve |
| Temperature Control Range (Valve, Quantitative Loop & Transfer Line) | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Volume | 1.0 mL (customizable from 50 µL to 5 mL via quantitative loop) |
| Sample Positions | 36 (expandable to 90 positions via modular 36+18N configuration) |
| Sampling Time | 0–99.9 s |
| Loop Equilibration Time | 0–99.9 s |
| Injection Channels | 1 (customizable) |
| Repeatability | <0.5% RSD (at 100 ppm total hydrocarbons or methane) |
| Power Consumption | 300 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 55 × 42 × 58 cm |
| Weight | ~25 kg |
| Sampling Pump | Corrosion-resistant diaphragm pump |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Software | PC-based control with bilingual (English/Chinese) GUI, full audit trail, GLP-compliant event logging |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi AGS-72 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Positions | 72 |
| Max Repeated Injections | Unlimited |
| Min Injection Volume | 0.5 mL (customizable) |
| Quantitative Loop Volume | 1 mL (customizable) |
| Positioning Accuracy | <0.3 mm |
| Motion Control | Precise Valve Switching |
| Needle Cleaning Method | Reverse Purge |
| Reproducibility | <1.5% RSD (at 100 ppm methane) |
| Power Consumption | 300 W |
| Input Voltage | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 55 × 42 × 58 cm |
| Weight | ~25 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi AGS-H25 |
| Instrument Type | Multifunctional Gas Autosampler |
| Max Sample Capacity | 25 positions |
| Minimum Injection Volume | 0.5 mL (customizable) |
| Quantitative Loop Volume | 1 mL (customizable) |
| Positioning Accuracy | <0.3 mm |
| Motion Control | Precision valve-switching actuation |
| Needle Cleaning Method | Reverse purge |
| Repeated Injection Capability | Unlimited |
| Valve & Tubing Temperature Range | Ambient to 220 °C ±0.1 °C |
| Sample Port Temperature Range | Ambient to 150 °C ±1 °C |
| Reproducibility | <1.5% RSD (at 100 ppm methane) |
| Power Consumption | 1500 W |
| Electrical Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 725 × 500 × 680 mm |
| Weight | ~55 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi ATD I-26 |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, 6-port valve, transfer line) |
| Desorption Pressure/Flow Range | 0–300 mL/min (continuously adjustable) |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 26 positions |
| Sorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 500 W |
| Dimensions (W×D×H) | 605 × 350 × 520 mm |
| Weight | ~30 kg |
| Desorption Recovery Efficiency | >98% |
| Flow Display | Digital electronic mass flow indication |
| Control Interface | Integrated 7-inch capacitive touchscreen |
| Method Storage | Up to 10 user-editable and recallable methods |
| Automation | Fully automated unattended operation with GC and data system synchronization |
| Leak Detection | Built-in automatic leak check routine |
| Fault Monitoring | Real-time thermal and pneumatic fault diagnostics |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD I-26D |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, six-port valve, transfer line) |
| Desorption Flow Rate | 0–300 mL/min, continuously adjustable |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 52 positions (26 × 2 dual-channel configuration) |
| Trap Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 600 W |
| Dimensions (W×D×H) | 810 × 450 × 510 mm |
| Weight | ~35 kg |
| Desorption Recovery Rate | >98% |
| Valve Type | Heated six-port rotary valve |
| Interface | Touchscreen HMI, event-triggered GC start, 10 programmable methods |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi ATD I-50 |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, 6-port valve, transfer line) |
| Desorption Pressure/Flow Range | 0–300 mL/min (continuously adjustable) |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 50 positions |
| Sorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 500 W |
| Dimensions (W×D×H) | 605 × 350 × 520 mm |
| Weight | ~30 kg |
| Desorption Recovery Rate | >98% |
| Interface | Touchscreen HMI with event-triggered GC synchronization |
| Method Storage | 10 user-editable, recallable methods |
| Leak Detection | Integrated real-time pressure decay monitoring |
| Fault Diagnostics | Auto-alert with on-screen status code and operational log |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD II-26 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | Ambient to 400 °C, Control Accuracy: ±1 °C |
| Secondary Desorption Temperature Range | Ambient to 450 °C, Heating Rate: >4000 °C/min |
| Valve Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cryo-Focusing Trap Temperature Range | −40 °C |
| Temperature Control Precision (Cryo Trap) | <±0.1 °C |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 26 tubes |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD II-26D |
| Instrument Type | Secondary Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C, Heating Rate >3600 °C/min |
| Cold Trap Temperature Range | −40 °C to Ambient (Electronic Cooling) |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 52 Positions (26 × 2 Dual Channels) |
| Valve & Transfer Line Temp Control | Ambient to 220 °C (±1 °C) |
| Focusing Tube Temp Control | Ambient to 450 °C, Heating Rate >3000 °C/min |
| Carrier Gas Flow Control | 0–100 mL/min (Backflush), 100 mL/min (Sample Preparation) |
| Timing Resolution | 0.1 min (0.0–999.9 min) |
| Adsorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (¼″ × 3.5″) |
| Power | 900 W, 220 V, 50 Hz |
| Dimensions | 810 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Acrichi ATD II-50 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 450 °C |
| Heating Rate | >6000 °C/min |
| Six-Port Valve Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 220 °C |
| Cold Trap Temperature Range | −40 °C to Ambient (Electronic Cooling) |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 50 positions |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | DK802A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260°C |
| Valve & Transfer Line Temperature Range | Ambient to 220°C |
| Temperature Control Accuracy | ±0.1°C |
| Sample Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Loop Volume | 1 mL (customizable) |
| RSD | <1.5% (for 200 ppm ethanol in water) |
| Power | 500 W |
| Voltage/Frequency | AC 220 V, 50 Hz |
| Dimensions | 50 × 32 × 60 cm |
| Weight | ~30 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Acrichi DK802T |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Quantitative Loop Volume | 1 mL (customizable) |
| Precision (RSD) | <1.5% (for 200 ppm ethanol in water) |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | DK803A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260°C |
| Valve & Transfer Line Temperature Range | Ambient to 220°C |
| Temperature Control Accuracy | ±0.1°C |
| Sample Vial Capacity | 30 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Quantitative Loop Volume | 1 mL (customizable) |
| RSD | <1.5% (for 200 ppm ethanol in water) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 50 × 45 × 60 cm |
| Weight | ~40 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | DK808A |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260 °C |
| Valve Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Vial Capacity | 112 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Quantitative Loop Volume | 1 mL |
| RSD (Repeatability) | <1.5% (200 ppm ethanol in water) |
| Power Consumption | 400 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 60 × 68 × 68 cm |
| Weight | ~55 kg |
| Warranty | 12 months (parts, electronics, firmware |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | PTC-106 |
| Sample Capacity | 106 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | −40 °C to 450 °C |
| Purge Heater Temperature Range | Ambient to 100 °C |
| Vial Cooling Temperature Range | 4 °C to Ambient |
| Instrument Type | Water-and-Soil Dual-Mode Purge and Trap Device |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi PTC-56 |
| Sample Capacity | 56 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | Ambient to 450 °C |
| Purge Sample Heating Range | Ambient to 100 °C |
| Sample Vial Cooling Range | −40 °C to Ambient |
| Purge Flow Rate | 10–150 mL/min (continuously adjustable) |
| Cold Trap Temperature Range | −40 °C to Ambient (electronic cooling) |
| Focusing Trap Ramp Rate | >4800 °C/min |
| Dimensions | 650 × 880 × 530 mm |
| Weight | ~40 kg |
| Power | 220 V, 50 Hz, 800 W |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi PTC-86 |
| Sample Capacity | 86 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | Ambient to 450 °C |
| Purge Sample Heating Range | Ambient to 100 °C |
| Sample Vial Cooling Range | −40 °C to Ambient |
| Purge Flow Rate | 5–500 mL/min (continuously adjustable) |
| Valve & Transfer Line Temp Control | Ambient to 220 °C (±1 °C) |
| Cold Trap Temp Control | −40 °C to Ambient (electronic cooling, ±1 °C) |
| Water Removal Trap Temp Range | Ambient to 400 °C |
| Distilled Water Rinse Temp Range | Ambient to 90 °C (±1 °C) |
| Solid Sample Vial Temp Range | Ambient to 100 °C (±1 °C) |
| Ramp Rate (Trap) | >4800 °C/min |
| Power | 800 W |
| Dimensions | 650 × 880 × 530 mm |
| Weight | ~40 kg |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | ATS-051 |
| Instrument Type | Preparative HPLC/LC Autosampler |
| Maximum Sample Capacity | 5 vials |
| Minimum Sample Volume per Injection | 1 mL |
| Loop Volume Range | 2–20 mL |
| Positioning Accuracy | ±0.1 mm (verified by encoder feedback) |
| Drive Mechanism | Precision Syringe Pump |
| Needle Wash | Integrated Solvent Flush with Dual-Path Solvent Selection |
| Repeat Injection Capability | Unlimited cycles per sample |
| Maximum Single Injection Volume | 50 mL |
| Compatibility | Standalone operation or integration with third-party preparative LC systems (e.g., Gilson, Biotage, Teledyne ISCO, Shimadzu, Waters) |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | ATS-A5 |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 108 × 2 mL vials (standard), optional configurations available |
| Injection Modes | Full-loop, Partial-loop, and Needle-in-Loop (NIL) injection |
| Injection Volume Range | 0.1–25 µL (with standard loop) |
| Precision | RSD < 0.25% (full-loop), < 0.5% (partial-loop, >10 µL), < 0.8% (NIL, <5 µL) |
| Carryover | < 0.05% |
| Maximum System Pressure | 40 MPa (standard HPLC), 60 MPa (UHPLC-compatible) |
| Safety Features | Vial-missing detection, needle-strike alarm, tubing blockage detection, leak monitoring |
| Optional | Peltier-based sample cooling module |
| Dimensions (W×D×H) | 300 × 450 × 320 mm |
| Weight | ~25 kg |
| Brand | Agela |
|---|---|
| Model | CC-100 |
| Origin | Tianjin, China |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Stability | ±0.1°C |
| Temperature Uniformity | ±0.3°C (across chamber) |
| Control Method | PID digital control with touch keypad |
| Display | LED digital display |
| Safety Features | Over-temperature protection cutoff |
| Chamber Design | Vertical upright configuration with magnetic-latch dual-layer lid (outer magnetic cover + insulated inner cover) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 320 × 380 mm |
| Net Weight | 8.5 kg |
| Cooling | None (heating-only operation) |
| Brand | Agela |
|---|---|
| Model | FL-C100 |
| Type | Mixed-Mode Fraction Collector |
| Collection Axes | X-Y Dual-Axis |
| Positioning Accuracy | ≤ ±0.5 mm |
| Compatible Vessel Types | Conical Flasks, Round-Bottom Flasks, Beakers, Test Tubes |
| Waste/Collection Channel Switching | Dual-Path Solenoid-Valve Controlled |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 420 × 480 × 450 mm |
| Weight | 28 kg |
| Origin | Tianjin, China |
| Regulatory Compliance | CE-marked per EN 61010-1 for Laboratory Equipment |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Type | Liquid-phase Fraction Collector |
| Max Flow Rate | 1 L/min |
| Collection Vessel Options | 13 mm, 15 mm, 18 mm, 25 mm test tubes & 100 mL conical flasks |
| Collection Modes | Full-collection, Manual-triggered, Threshold-triggered (peak-based), Waste/Collection Switching |
| Tube Rack Compatibility | F1–F4 standard racks (13–25 mm) + custom rack support |
| Interface | RS-232 |
| Design | Multi-channel bow-shaped collection head with adjustable software-defined coordinates |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | Refractive Index Detector (RID) |
| Flow Rate Range | 1–50 mL/min |
| Flow Cell Volume | 7 µL |
| Temperature Control Range | 35–55 °C (adjustable in 1 °C increments |
| Flow Cell Pressure Rating | 6 kg/cm² |
| Internal Cell Dead Volume | 88 µL or 353 µL (selectable) |
| Linear Range | 0–2000 µRIU |
| Noise Level | ≤10 × 10⁻⁸ RIU |
| Drift (Full-Scale) | <1 mV/hour with 1 mL/min H₂O flow |
| Auto-Zero Function | Yes |
| Integrated Flush Valve | Yes |
| Digital Interface | RS-232 (bidirectional parameter transmission) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Bio-Inert Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Operating Pressure | Up to 600 bar |
| Carryover | <9 ppm |
| Temperature Control Range (Optional) | 4–40 °C |
| Flow Path Materials | Ceramic needle, PEEK needle seat, stainless-steel-coated PEEK capillary |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Diode Array Detector WR |
| Instrument Type | Diode Array Detector (DAD) |
| Wavelength Range | 190–950 nm |
| Short-Term Noise | < ±7 µAU (ASTM compliant) |