Illuminance Meter
Filter
Showing 1–30 of 73 results
| Brand | Acclima, Inc. |
|---|---|
| Origin | USA |
| Model | TDR310H |
| Volumetric Water Content (VWC) | 0–100% (0.1% resolution |
| Soil Temperature | −40 to +60 °C (0.1 °C resolution |
| Dielectric Constant | 1–80 (0.1 resolution |
| Bulk Electrical Conductivity (ECb) | 0–5000 μS/cm |
| Pore Water Electrical Conductivity (ECw) | 0–55,000 μS/cm (1 μS/cm resolution |
| Response Time | 0.25 s |
| Power Supply | 3.5–15 V DC |
| Operating Current | 36 mA @ 12 V DC (typical), <10 μA idle |
| Output Interface | SDI-12 |
| Probe Length | 15 cm |
| Probe Diameter | 0.35 cm |
| Dimensions | 22.56 × 3.34 cm |
| Weight | 440 g (body only, no cable) |
| Brand | Apogee Instruments |
|---|---|
| Origin | USA |
| Model | PS-300 |
| Spectral Range | 220–1100 nm |
| Wavelength Resolution | 1.5 nm |
| Detector | 2048-pixel CCD |
| Grating | Holographic, aberration-corrected, 590 g/mm |
| A/D Converter | 16-bit |
| Signal-to-Noise Ratio | 1000:1 |
| Stray Light | ≤0.02% @ 435 nm, ≤0.2% @ 200 nm |
| Measurement Repeatability | <1% |
| Irradiance Calibration Uncertainty | ±10% (300–1000 nm) |
| Cosine Response Error | ±5% up to 80° zenith angle |
| Integration Time | 1 ms – 65 s |
| Interface | USB 2.0 |
| Power | 5 VDC, 100 mA (bus-powered) |
| Operating Temperature | 0–60 °C |
| Fiber Optic Cable | 2 m armored silica fiber |
| Dimensions | 69 × 100 × 150 mm |
| Weight | 900 g |
| Brand | AS ONE |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Manufacturer |
| Country of Origin | China (Domestic) |
| Model No. | 1-5818-01 |
| Sensor Type | Silicon Photodiode |
| Display | 3.5-digit LCD with backlight |
| Accuracy | ±(5% rdg + 10 digits) |
| Sampling Rate | 2.5 samples/sec |
| Units | Lux (lx) and Foot-candles (fc), switchable via single button |
| Data Hold Function | Yes |
| Peak Hold Function | Yes |
| Sensor Mounting | Integrated fixing pin for secure sensor-to-body attachment |
| Power Supply | Not specified in source data |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-2007Z |
| Type | Portable |
| Measurement Range | 0.0–200,000 lx (4 auto-ranging scales) |
| Accuracy | ±3% RD, ±0.5% FS |
| Repeatability | ±2% |
| Temperature Coefficient | ±0.1%/°C |
| Display | 3.5-digit LCD, digit height 15 mm |
| Sampling Rate | 2.0 readings/sec |
| Photodetector | Silicon photodiode with calibrated spectral filter |
| Dimensions | 150 × 70 × 39 mm |
| Calibration Reference | Standard planar lamp at 2856 K (CIE Illuminant A) |
| Brand | BJBY |
|---|---|
| Model | UV-2000 |
| Measurement Range | 0.1–199,900 µW/cm² |
| Spectral Response | 230–290 nm (Peak at 254 nm) |
| Accuracy | ±5% |
| Response Time | 1 s |
| Out-of-Band Rejection | <0.1% |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <85% RH |
| Power Supply | 9 V alkaline battery |
| Power Consumption | ≤80 mW |
| Dimensions | 130 × 70 × 30 mm |
| Weight | 200 g |
| Probe Calibration | 254 nm UV-C specific |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BH1218 |
| Pricing | Upon Request |
| Gain Range | 5–750× (continuously adjustable) |
| Long-term Gain Stability | ≤0.1% (over 8 h) |
| Temperature Coefficient of Gain | ≤0.015%/°C |
| Integral Nonlinearity | ≤0.2% |
| Input-Referred Noise | ≤15 µV RMS |
| Overload Recovery | Recovers to within 2% of baseline at 2.5× nominal pulse width after 200× overload |
| Input Polarity | Positive or Negative |
| Output Polarity | Positive |
| Output Impedance | 50 Ω |
| Shaping Time Constants | 0, 0.5, 1, 2, 3, 4, 5, 6 µs |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤90% at +40 °C |
| Power Supply | ±24 V / 30 mA, ±12 V / 10 mA |
| Power Consumption | 2 W |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Model | BH1219A |
| Form Factor | NIM-standard 1-unit-width module |
| Dynamic Range | Threshold 0.1–10 V |
| Stability | Threshold drift ≤ ±15 mV (8 h), Channel width drift ≤ ±15 mV (8 h), Delay drift ≤ ±15 ns (8 h) |
| Temperature Coefficient | ≤ 1.5 mV/°C (threshold & channel width) |
| Linearity | Threshold integral linearity ≤ 0.5% |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤ 90% at 40 °C |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Model | FH1016A |
| Output Voltage Range | ±300 V to ±3 kV (3-range selectable: 0–1 kV, 0–2 kV, 0–3 kV) |
| Rated Output Current | 0–500 µA |
| Output Ripple | ≤20 mV (p-p) |
| Voltage Stability | ≤±0.1% over 8 hours |
| Operating Temperature | 0–50 °C |
| Form Factor | 2-unit NIM module |
| Polarity | Selectable positive or negative DC output |
| Application | Bias supply for nuclear radiation detectors (e.g., PMTs, SiPMs, proportional counters) |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FH1047A |
| Pricing | Available Upon Request |
| Charge Sensitivity | 1×10¹² V/C or 40 mV/MeV (Si) |
| Noise Performance (FWHM, Si) | ≤2.2 keV + 0.05 keV/pF (Type A, typical 1.5 keV + 0.04 keV/pF) / ≤2.5 keV + 0.03 keV/pF (Type B, typical 1.5 keV + 0.03 keV/pF) |
| Output Pulse Rise Time | ≤30 ns (with zero external capacitance) |
| Max Linear Output Range | +2 V (1 kΩ load) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤90% at +40 °C |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FH1048A |
| Price | Upon Request |
| Gain | 5× |
| Gain Stability | ≤±0.03% over 8 h continuous operation |
| Integral Nonlinearity | ≤0.5% (with 1 kΩ load, 2 V output) |
| Input Impedance | ≥500 kΩ |
| Rise Time | ≤30 ns |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤90% at 40 °C |
| Brand | CNCs (China Nuclear Control Systems) |
|---|---|
| Model | FH1093B |
| Form Factor | 4U NIM Module |
| Input Polarity | Positive |
| Pulse Width Minimum | ≥0.1 µs |
| Dead Time (Dual-Pulse Resolution) | ≤300 ns |
| Discrimination Threshold Range | 0.2–5 V (continuously adjustable, three identical channels) |
| Threshold Temperature Coefficient | 1 mV/°C (0–50 °C) |
| Overload Capacity | 5× nominal threshold |
| Maximum Count Rate | ≥2 × 10⁶ s⁻¹ |
| Count Capacity | 10⁷–1 (seven-digit down-counter) |
| Timing Range | K × 10ⁿ (K = 1–9 |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤90% at +40 °C |
| Power Supply | Standard NIM bin (+6 V, −6 V, +12 V, −12 V) |
| Brand | CNCS (China Nuclear Control System) |
|---|---|
| Origin | Beijing, China |
| Model | FH463B |
| Input Impedance | 1 kΩ |
| Input Coupling | AC |
| Pulse Width Range | 0.1 µs – 100 µs |
| Dead Time | ≤200 ns |
| Threshold Range | 0.1 V – 5.0 V (adjustable, linearity deviation ≤±0.5%) |
| Window Width Range | 0.1 V – 3.0 V |
| Polarity | Positive or Negative (input & HV output) |
| Timing Range | K×10ⁿ s (K = 1–9, n = 0–6) |
| Max Count Rate | ≤4.5 MHz |
| Max Count Capacity | 1.5×10⁷ − 1 |
| HV Output Range | ±50 V to ±1500 V (±10 V resolution, stability ≤±0.3% over 8 h after 30-min warm-up) |
| HV Current Limit | ≤600 µA |
| HV Ripple | ≤50 mV RMS |
| HV Temp. Coefficient | ≤±0.05 %/°C |
| Discriminator Temp. Coefficient | ≤±3 mV/°C |
| Low-Voltage Outputs | ±10 V, +5 V |
| Communication Interface | RS-232 (9600 baud, pinout: 3-TXD, 5-GND) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% at 30 °C |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | CNCs (China Nuclear Control Systems) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | FJ365 |
| Pricing | Available Upon Request |
| Brand | CNMC (China Nuclear Control System) |
|---|---|
| Origin | Beijing, China |
| Model | BH1220 |
| Form Factor | 2-unit NIM Standard Module |
| Discrimination Threshold Range | 0.2–5 V |
| Input Polarity | Positive or Negative (Front & Rear Panel Inputs) |
| Input Pulse Width | 0.1–100 µs |
| Dead Time (Dual-Pulse Resolution) | ≤300 ns |
| Timing Range | K×10ⁿ (K = 1–9 |
| Maximum Counting Rate | ≥2 MHz |
| Overload Capacity of Discriminator | 5× nominal threshold |
| Count Capacity | 10⁷ – 1 |
| Max Instantaneous Power Consumption | 2.7 W |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤90% at +40 °C |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Model | FY-18L |
| Light Source | 18 W High-Power White LED |
| Illuminance | ~34,000 lux at 45 cm (with clear filter) |
| Adjustable Brightness | Continuous DC dimming (0–100%) |
| Optical Output | Dual-filter system (clear and diffuser), optional Daiglo green bandpass filter (transmission peak ~525 nm, cutoff <500 nm & >600 nm) |
| Cooling | Fanless active heat sink |
| Power Input | AC 100–240 V, 47–63 Hz |
| Output | DC 24 V / 1.67 A |
| Power Consumption | 2.8–22.6 W |
| LED Lifetime | ≈50,000 h (L70) |
| Dimensions (Base) | W180 × D120 × H50 mm |
| (Light Head) | Ø68 × D86 mm |
| (Max Extended Height) | 638 mm |
| Weight | 3.4 kg (lamp only, excluding adapter) |
| Photodetector Type | Silicon photodiode (integrated illuminance reference path) |
| Compliance | CE-marked per EN 61326-1 (EMC), EN 62471 (Photobiological Safety), RoHS 2015/863/EU |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CL-200 |
| Pricing | Upon Request |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CL-200A |
| Illuminance Range | 0.1–99,990 lx |
| Luminance Range | 0.01–9,999 fcd |
| Chromaticity Accuracy (xy) | ±0.002 at 800 lx (Standard Illuminant A) |
| Repeatability (xy) | ±0.0005 (2σ) |
| Cosine Correction Error (f₂) | <3% |
| f₁' Error vs. CIE Photopic Luminosity Function | <6% |
| Response Time | 0.5 s (continuous measurement) |
| Operating Temp. | −10–40°C, RH ≤85% (non-condensing) |
| Battery Life | >72 h (alkaline, continuous use) |
| Dimensions | 69 × 174 × 35 mm |
| Weight | 215 g (without batteries) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Type | Imported Instrument |
| Model | CL-200A Series |
| Power Supply | 4 × AA batteries (alkaline or Ni-MH) |
| Display | Backlit LCD with real-time color and illuminance values |
| Measurement Modes | Illuminance (lx), Chromaticity (CIE 1931 xy, u'v'), Correlated Color Temperature (CCT, K), Duv, Color Rendering Index (CRI Ra, R1–R14), LED-specific metrics (Δu'v', TM-30 parameters optional via software) |
| Probe Connectivity | Detachable sensor head with proprietary 1.5 m cable (adapter required for integration into integrating spheres or dark chambers) |
| Data Interface | USB 2.0 (virtual COM port) |
| Software | CL-S10w Data Management Software (included) with Excel®-direct export, JIS Z 9112-compliant CCT calculation, LED binning support, multi-point synchronization (up to 30 probes), user calibration (single-point or RGB-based), audit trail logging, and GLP-compliant report generation |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CL-500A Series |
| Measurement Range | 0.1–99,990 lx (typical) |
| Spectral Resolution | 1 nm |
| Wavelength Range | 380–780 nm |
| Accuracy | ±2% (illuminance), ±0.002 (chromaticity) |
| Interface | USB 2.0 |
| Software Included | CL-S10w Data Management Software & Excel® Add-in |
| Multi-unit Control | Up to 10 units via CL-S10w |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CL-500A |
| Spectral Range | 360–780 nm |
| Wavelength Interval | 1 nm |
| Spectral Bandwidth (FWHM) | ~10 nm |
| Wavelength Accuracy | ±0.3 nm (at 435.8, 546.1, 585.3 nm per JIS Z8724) |
| Illuminance Range | 0.1–100,000 lx |
| Illuminance Accuracy | ±2% ±1 digit (Std A source) |
| Chromaticity Accuracy (xy) | ±0.0015 (10–100,000 lx), ±0.002 (5–10 lx) |
| Repeatability (2σ, Std A) | Ev: 0.5% + 1 digit |
| xy | 0.0005 (500–100,000 lx) to 0.004 (5–30 lx) |
| f₁′ (Relative Spectral Responsivity) | ≤1.5% |
| f₂ (Cosine Correction Error) | ≤3% |
| fₜ / fₕ (Temp./Humidity Drift) | Ev: ±3% |
| xy | ±0.003 |
| Measurement Time | 0.2 s (Ultra-fast, PC-connected), 0.5–27 s (Auto-exposure) |
| Dimensions | 70 × 165 × 83 mm |
| Weight | 350 g |
| Battery Life | 6 h (fully charged) |
| Compliance | JIS C 1609-1:2006 Class AA, DIN 5032-7 Class B |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CL-70F |
| Illuminance Range (Continuous) | 1–200,000 lx |
| CCT Range | 1,563–100,000 K (xy display ≥5 lx) |
| Flash Mode | 20–20,500 lx·s |
| Spectral Range | 380–780 nm |
| Resolution | 1 nm |
| Sensor | CMOS linear image sensor |
| Compliance | JIS C1609-1:2006 Class AA, DIN 5032-7 Class C |
| Repeatability (2σ) | EV ±1%+1 digit (30–200,000 lx), xy ±0.001 (500–200,000 lx) |
| Interface | USB 2.0 Mini-B |
| Power | USB bus-powered |
| Operating Temp. | −10 to +40 °C, RH ≤85% (non-condensing) |
| Dimensions | 73 × 183 × 27 mm (W×H×D, excluding protrusions) |
| Data Storage | 999 readings |
| Software | CL-SU1w (included) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CL-70F |
| Illuminance Class | JIS C1609-1:2006 Class A / DIN 5032-7 Class C |
| Spectral Range | 380–780 nm |
| Wavelength Resolution | 1 nm |
| Continuous Illuminance Range | 1–200,000 lx |
| CCT Range | 1,563–100,000 K (≥5 lx for chromaticity) |
| Flash Energy Range | 20–20,500 lx·s |
| Ev Accuracy | ±(1% + 1 digit) from 30–200,000 lx |
| Chromaticity Accuracy (xy) | ±0.003 at 800 lx |
| f1' Spectral Mismatch | ≤9% |
| f2 Cosine Error | ≤6% |
| Operating Temp. | −10 to 40 °C |
| Weight | 230 g |
| Interface | USB 2.0 Mini-B |
| Data Storage | 999 records |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CM-23d |
| Illumination/Observation Geometry | di:8°/de:8° (Diffuse Illumination/8° Viewing) |
| Measurement Modes | SCI (Specular Component Included) / SCE (Specular Component Excluded) |
| Compliance | ISO 7724-1, CIE No.15:2004, DIN 5033-7, JIS Z 8722 Condition c, ASTM E1164 (SCI) |
| Integrating Sphere Diameter | Ø54 mm |
| Detector | Dual-row 32-element silicon photodiode array |
| Dispersion Element | Diffraction grating |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| FWHM | ~10 nm |
| Reflectance Range | 0–175% |
| Display Resolution | 0.01 |
| Light Source | Pulsed xenon lamp ×1 (with UV-cut filter) |
| Illumination Aperture | Ø12 mm |
| Measurement Aperture | Ø8 mm |
| Repeatability | ΔE*ab ≤ 0.08 (SD, 30 measurements on white calibration tile at 5 s intervals post-calibration) |
| Inter-instrument Agreement | ΔE*ab ≤ 0.4 (mean of 12 BCRA Series II tiles, MAV/SCI, vs. Konica Minolta reference standard under standard conditions) |
| UV Adjustment | Fixed 0% (400 nm UV-cut filter) |
| Standard Observers | 2° and 10° |
| Illuminants | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (dual-illuminant comparison supported) |
| Color Spaces | L*a*b*, L*C*h*, CMC (1:1), CMC (2:1), Yxy, XYZ, Munsell (C), MI, WI (ASTM E313-73), YI (ASTM D1925), Opacity, User-defined parameters |
| Color Difference Formulas | ΔE*ab (CIE 1976), ΔE94 (CIE 1994), ΔE00 (CIE 2000), CMC (l:c) |
| Measurement Time | ~0.7 s (SCI or SCE mode) |
| Minimum Measurement Interval | ~1.5 s |
| Memory Capacity | 1,000 target + 1,700 sample data sets |
| Battery Life | ~3,000 measurements (10 s interval, 23°C, no Bluetooth) |
| Viewfinder | Integrated white LED |
| Display | 2.7″ TFT color LCD |
| Languages | English, Japanese, German, French, Italian, Spanish, Simplified Chinese, Portuguese, Russian, Turkish, Polish |
| Interfaces | USB 2.0, Bluetooth SPP (optional module CM-A219) |
| Power | Removable Li-ion battery (CM-A235), USB bus power, AC adapter (AC-A305J/L/M) |
| Charging Time | ~6 h |
| Operating Environment | 5–40°C, ≤80% RH (non-condensing at ≤35°C) |
| Storage Environment | 0–45°C, ≤80% RH (non-condensing at ≤35°C) |
| Dimensions | 81(W) × 93(H) × 229(D) mm |
| Weight | ~620 g |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model Series | CS-150 / CS-160 |
| Measurement Angles | CS-150 — 1° |
| Luminance Range | CS-150 — 0.01 to 999,900 cd/m² |
| Output | CIE 1931 xy Chromaticity Coordinates, Luminance (Lv), Correlated Color Temperature (CCT), Dominant Wavelength, Excitation Purity |
| Compliance | JIS Z 8722, CIE No. 15, ISO/CIE 11664-3, ASTM E308 |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS-200 Series |
| Price | USD 16,800 (FOB Yokohama) |
| Measurement Principle | Spectral Response Curve Fitting with 40-Channel Photodiode Array |
| Luminance Range | 0.01 to 20,000,000 cd/m² |
| Field of View Options | 1°, 0.2°, 0.1° |
| CIE Observer Modes | 2° and 10° Standard Observer |
| Compliance | CIE 1931 Color Matching Functions, JIS Z 8722, ISO/CIE 11664-3, ASTM E308-22 |
| Power Supply | Rechargeable Li-ion Battery or AC Adapter |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-2000 / CS-2000A Spectroradiometer |
| Wavelength Range | 380–780 nm |
| Wavelength Resolution | 0.9 nm/pixel |
| Spectral Bandwidth (FWHM) | <5 nm |
| Wavelength Accuracy | ±0.3 nm (at Hg-Cd lamp calibration lines: 435.8, 546.1, 643.8 nm) |
| Measurement Angles | 1°, 0.2°, 0.1° (interchangeable optical attachments) |
| Luminance Range (Illuminant A) | CS-2000: 0.003–5,000 cd/m² (1°), 0.075–125,000 cd/m² (0.2°), 0.3–500,000 cd/m² (0.1°) |
| CS-2000A | 0.0005–5,000 cd/m² (1°), 0.0125–125,000 cd/m² (0.2°), 0.05–500,000 cd/m² (0.1°) |
| Minimum Measurable Spot Size | ∅5 mm (standard), ∅1 mm (with close-up lens |
| Minimum Measurement Distance | 350 mm (standard), 55 mm (with close-up lens) |
| Radiant Exitance Detection Limit | 1.0×10⁻⁹ W/(sr·m²·nm) |
| Luminance Accuracy (Illuminant A) | ±2% |
| Chromaticity Accuracy (Illuminant A) | x,y ±0.001 (≥0.05 cd/m² for CS-2000A |
| Chromaticity Repeatability (2σ, Illuminant A) | x,y ≤0.0006 (e.g., 0.1–0.2 cd/m² and 2.5–5 cd/m² ranges) |
| Polarization Error | ≤2% (1°, 400–780 nm), ≤3% (0.1°/0.2°, 400–780 nm) |
| Integration Time | 5 ms–120 s (Normal mode) |
| Interface | USB 1.1, RS-232C |
| Operating Environment | 5–35°C, ≤80% RH (non-condensing) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Power Consumption | ~20 W |
| Dimensions (main unit) | 158 × 262 × 392 mm (W×H×D) |
| Lens | ∅70 × 95 mm |
| Weight | 6.2 kg |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | CS-3000 Series |
| Measurement Principle | Diffraction-grating-based spectroradiometry |
| Luminance Range | 0.0005–3,000 cd/m² (typical, dependent on aperture and lens configuration) |
| Chromaticity Accuracy | ±0.002 in CIE x,y (against NIST-traceable standards) |
| Spectral Resolution | ≤5 nm FWHM |
| Integration Time | 10 ms–10 s (programmable) |
| Interface | USB 2.0, RS-232C, Ethernet (optional) |
| Compliance | ISO/CIE compliant spectral measurement architecture |
| Software Support | Konica Minolta SpectraMagic™ NX v3.x |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | LS-150 / LS-160 Series Luminance Meter |
| Luminance Range (LS-150, 1° FOV) | 0.001–999,900 cd/m² |
| Luminance Range (LS-160, 1/3° FOV) | 0.01–9,999,000 cd/m² |
| Minimum Measurable Luminance | 0.001 cd/m² |
| Field of View Options | 1° (LS-150), 1/3° (LS-160) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | ProMetric I (I2 to I29 variants) |
| Sensor Type | Scientific-grade CCD |
| Resolution Range | 2.0 MP (I2) to 29.0 MP (I29) |
| Measurement Units | cd/m², CIE x,y |
| Compliance | ISO/CIE-compliant photopic and colorimetric response |
| Interface | GigE Vision, USB 3.0, GenICam-compatible |
| Software Platform | TrueTest™ v7+ with automated pass/fail reporting, statistical process control (SPC), and audit trail (21 CFR Part 11 ready) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | ProMetric Y |
| Type | Scientific Imaging Photometer |
| Application Focus | Display Luminance & Uniformity Metrology, Mura Analysis, AOI for FPDs and Backlit Components |
| Compliance Context | Designed for ISO/CIE-compliant photometric measurement, supports GLP/GMP-aligned data traceability via TrueTest software audit trails |