| Brand | ADCON |
|---|---|
| Origin | Switzerland |
| Model | PA-1 |
| Pressure Range | 0–10 bar (absolute) |
| Overpressure Limit | 20 bar |
| Operating Temperature | −40 °C to +80 °C |
| Compensated Temperature Range | 0 °C to +50 °C |
| Accuracy (0–50 °C) | ±0.1% FS typical, ±1.5% FS max |
| Linearity | ±0.25% FS typical, ±0.5% FS max |
| Sensing Principle | Piezoresistive |
| Output Signal | 0.1–2.5 V ratiometric |
| Supply Voltage | 3.5–12 V DC |
| Thread Connection | G 1/4" (NPT & G 1/2" adapters available) |
| Housing Diameter | 22 mm |
| Length | 49 mm |
| Weight | 30 g |
| Cable | Shielded PVC2 |
| Cable Length Options | 5 m or 10 m |
| Connector | 4-pin M12 male on sensor, 4-pin M12 female + 7-pin Binder M9 male on cable |
| IP Rating | IP67 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AKS-P8002 |
| Pressure Range | Up to 250 MPa |
| Accuracy Class | 0.02% / 0.05% (depending on range) |
| Pressure Port | M20×1.5 male thread & Φ6 mm quick-connect (differential type) |
| Electrical Test | Voltage (-30–30 V), Current (-30–30 mA), Switch Test, 24 V Loop Power |
| Dimensions | Ø120 mm × 46 mm (head), Total Length 184 mm |
| Weight | 0.7 kg |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | PHO-EXTEND Series |
| Channel Density | Up to 120 channels per chassis |
| Interface | USB 2.0, Gigabit Ethernet, GPIO |
| DAC Resolution | 16-bit |
| Output Modes | Unipolar, Bipolar, Differential |
| Voltage Range (Standard) | ±16 V, 0–34 V, ±18 V |
| Current Range (Standard) | ±500 mA, 0–300 mA, ±500 mA |
| Software Support | SCPI (Python, C#, MATLAB, LabVIEW), CSV-based sequence programming, GUI with real-time monitoring |
| Processor | Quad-Core 64-bit ARM Cortex-A53 (ARM v8) |
| Compliance | GLP/GMP-ready audit trail logging (Premium firmware), ISO/IEC 17025 traceable calibration support (optional) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SC4-18, SC4-31, SC4-34, SC4-16, SC4-25Z, KU-1030, KU-1031, T-A–T-F, SA-70, SSA, BTU-18Y, SC4-DSY, SC4-13RPY, SC4-13RD, SC4-27SD, SC4-27 Link Hanging Assembly |
| Shear Rate Range | Instrument-dependent (DVNext/RV series) |
| Torque Range | 0.28–1.32 N·cm |
| Sample Volume | 4.2–9.4 mL |
| Material | 316 Stainless Steel (standard), Anodized Aluminum (select spindles) |
| Compliance | ASTM D1200, ISO 2555, ISO 3219, USP <911>, GLP-ready with audit-trail-capable software |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | HPC40 Series |
| Pressure Range | Up to 15,000 psi (1000 bar / 100 MPa) |
| Accuracy | ±0.035% of reading |
| Operating Temperature Compensation | Full-range compensation from −20 °C to +50 °C |
| Functionality | Simultaneous pressure measurement & mA loop sourcing/sinking (0–24 mA), voltage measurement (0–30 VDC), temperature measurement via Pt100/Pt1000 (True Ohms mode) |
| Interface | Menu-free, direct-access button layout |
| Power Options | Rechargeable Li-ion battery with AC adapter |
| Design | Modular, field-serviceable architecture |
| Calibration Targets | Analog and digital pressure gauges, transmitters, switches, and I/P converters |
| Compliance | Designed for traceable calibration in accordance with ISO/IEC 17025, ASTM E74, and EN 837-1 |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | HPC50 Series |
| Calibration Targets | Pressure Gauges & Transmitters |
| Design | Modular Architecture |
| Accuracy | ±0.035% of Reading |
| Pressure Ranges | Up to 15,000 psi / 1000 bar / 100 MPa (Gauge, Absolute, Differential) |
| Temperature Compensation | –20 °C to +50 °C |
| Electrical Measurement | mA and V |
| Resistance Measurement | True Ohms Technology |
| Display | Enhanced High-Contrast LCD |
| Battery Life | Extended vs. HPC40 |
| Certifications | ATEX/IECEx Intrinsically Safe (Zone 0/1, Class I Div 1) |
| Interface | Dual External Module Ports (Pressure & Temperature) |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | nVision Reference Recorder |
| Type | Pressure Calibrator |
| Calibration Target | Pressure Controllers |
| Design | Modular Architecture |
| Pressure Range | Up to 15000 psi (1000 bar, 100 MPa) |
| Accuracy (Differential Pressure) | ±0.025% of reading |
| Data Storage | 500,000 points |
| Sampling Rate | 10 readings per second per 2 modules |
| Environmental Rating | Submersible to 3 ft (≈0.9 m) |
| Operating Temperature Range | −20 °C to +50 °C |
| Thermal Compensation | Full accuracy compensation across −20 °C to +50 °C |
| Certification | A2LA-accredited calibration certificate with test data at five temperature points |
| Input/Output Capabilities | Gauge & absolute pressure, switch status, voltage, current, and temperature |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | XP2i |
| Measurement Type | Pressure/Vacuum Gauge |
| Reference | Gauge Pressure |
| Explosion Protection | Intrinsically Safe (ATEX/IECEx certified) |
| Operating Temperature Range | −10 °C to +50 °C (full accuracy maintained) |
| Accuracy | ±0.1% of full scale |
| Max Working Pressure | 15,000 psi (103.4 MPa) |
| Display | Dual-line LCD |
| Data Logging Capacity | 32,000 points (with optional DataLoggerXP software) |
| Battery Life | Up to 1 year continuous logging in Ultra-Low-Power (ULP) mode |
| Enclosure Rating | Marine-grade corrosion-resistant housing |
| User Interface | Menu-free, direct-function operation |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | XP2i-DP |
| Type | Intrinsically Safe Wet/Wet Differential Pressure Gauge |
| Accuracy | ±0.1% of full scale |
| Measurement Range | Vacuum to Positive Differential Pressure |
| Housing | Marine-grade corrosion-resistant stainless steel (316 SS) |
| Configuration | Panel-mount or portable |
| Pressure Units | User-selectable (kPa, bar, psi, inH₂O, mmH₂O, mbar, etc.) |
| Data Logging | Optional DataLoggerXP module (32,000-point capacity, 1-year continuous logging in ULP mode) |
| Power | Optimized long-life battery with Ultra-Low-Power (ULP) operation |
| Compliance | ATEX/IECEx certified for hazardous areas (Zone 0/1, Class I Div 1), IP67 ingress protection |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | XP3i |
| Accuracy Options | ±0.05% of reading, ±0.02% FS, ±0.05% FS |
| Measurement Range | Up to 10,000 psi (68.9 MPa) |
| Type | Dual-mode pressure/vacuum gauge |
| Pressure Reference | Gauge (vented) |
| Media Compatibility | Corrosion-resistant wetted materials (e.g., 316L stainless steel, FKM seals) |
| Operating Temperature | −20 °C to +50 °C (full accuracy maintained across range) |
| Enclosure Rating | Marine-grade corrosion-resistant housing, ATEX/IECEx certified for intrinsic safety in hazardous areas (Zone 0/1, Class I Div 1) |
| Connectivity | USB 2.0, Bluetooth 5.0 (BLE), optional DataLoggerXP firmware upgrade |
| Software | CrystalControlWeb cloud platform (free), mobile app (iOS/Android), PC desktop utility |
| Brand | Elveflow |
|---|---|
| Origin | France |
| Model | MPS |
| Accuracy | ±0.2 % FS |
| Pressure Ranges | 70–7,000 mbar (5 selectable full-scale options) |
| Internal Volume | 7 µL |
| Response Time (Stabilization) | 20 ms |
| Media Compatibility | Liquids and Gases |
| Connection | Compatible with 3/32" ID tubing or 10-32 threaded fitting for 1/16" OD tubing |
| Type | Gauge Pressure Sensor (relative to ambient atmospheric pressure) |
| Brand | Biaozhuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LKY-005 |
| Price | USD 2,380 (FOB Shanghai) |
| Measurement Range | 0–100 mm |
| Repeatability | ±0.05 mm |
| Resolution | 0.01 mm |
| Maximum Permissible Error | ±(0.03 + 0.003L) mm (calibrated against Grade 2 gauge blocks) |
| Compliance | JJG 146–2003 (Chinese National Verification Regulation for Gauge Blocks) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | DE90 |
| Measurement Principle | Piezoresistive Ceramic Sensor Technology |
| Output Signal | 4–20 mA (2-wire), optional 0–10 V |
| Accuracy | ±0.1 % FS |
| Long-Term Stability | <0.1 % FS/year |
| Operating Temperature Range | –20 to +70 °C |
| Enclosure Rating | IP65 |
| Media Compatibility | Air and neutral gases |
| Max. Overpressure | 5× full scale |
| Supply Voltage | 12–36 V DC |
| Response Time | <100 ms |
| Certifications | CE, RoHS, optionally ATEX II 3G Ex nA IIC T4 Ga (for DE43 variant), compliant with DIN EN 61326-1 (EMC), DIN EN 61000-6-2/6-4 |
| Brand | KEYENCE |
|---|---|
| Origin | Japan |
| Manufacturer | KEYENCE Corporation |
| Product Type | Imported Industrial Pressure Sensor |
| Model | GP-M Series |
| Pricing | Available Upon Request |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PPT Series |
| Output Options | RS232 / RS485 Digital or 0–5 VDC Analog |
| Accuracy | ±0.05% FSO over –40 to +85 °C |
| EMC Protection | Enhanced EMI Shielding per EN 61326-1 |
| Certifications | CE Marked (EMC & LVD Directives) |
| Dual Outputs | Independent Pressure and Sensor Temperature Signals |
| Compliance | Meets EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emission) |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | PPT-R |
| Certification | FM, CSA, CE |
| Operating Temperature Range | –40 °C to +85 °C |
| Accuracy | ±0.05% FS (Full Scale Output) |
| Output Options | 0–5 VDC analog output |
| Digital Interface | RS232 / RS485 compatible |
| Enclosure | Hermetically Sealed, Ruggedized Housing with Integrated Cable |
| Compliance | ATEX Zone 1/21, IECEx, UL 913 Class I Div 1, EN 60079-0/-11 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHD-3100 |
| Pricing | Upon Request |
| Operating Principle | Electronic Pressure Control |
| Display | Digital LCD |
| Working Medium | Compressed Air |
| Battery | 5800 mAh Rechargeable Li-ion (≥7 days continuous operation) |
| Flow Control | Precision Electronic Mass Flow Control with Mechanical Fine-Tuning |
| Sample Interface | Universal SUMMA Canister Coupling (6-port or 12-port compatible) |
| Internal Surface Treatment | Silanized Stainless Steel Flow Path (including all internal tubing and fittings) |
| Environmental Rating | IP65 (Dust-tight, Water-resistant) |
| Brand | INFICON |
|---|---|
| Origin | Germany |
| Model | IC6 Thin Film Deposition Controller |
| Measurement Principle | Quartz Crystal Microbalance (QCM) with ModeLock Frequency Detection |
| Resolution | 0.00433 Å/s @ 100 ms sampling |
| Frequency Stability | ±0.0035 Hz |
| Max Simultaneous Sources | 6 |
| Layer Capacity | 50 processes × 200 layers = 10,000 total layers |
| Sensor Inputs | Up to 8 QCM sensors (averaged or independent) |
| Display | Color TFT LCD |
| I/O | 28 digital inputs, 24 relay outputs, 14 TTL outputs, 6 standard DACs + 6 optional DACs |
| Logic Engine | 100 programmable logic statements |
| Data Storage | Internal logging, screenshot capture, recipe storage |
| Communication | RS-232/485, optional Ethernet |
| Compliance | RoHS-compliant |
| Software Support | IC6 Configuration Editor (LabVIEW®-based, Windows®) |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6720-DP |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy (Pressure) | ±1.5% of reading ± 0.25 Pa |
| Resolution (Pressure) | 0.001 Pa |
| Air Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Air Velocity Range (with Air Velocity Matrix) | 0.15–15 m/s |
| Accuracy (Velocity) | ±3% of reading ± 0.05 m/s (for v > 0.25 m/s) |
| Resolution (Velocity) | 0.01 m/s |
| Display | 4.3-inch full-color capacitive touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 readings (mobile app) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power | 4 × AA alkaline batteries (≈14 h continuous operation) or DC 5 V input |
| Weight | ≈390 g |
| Communication | Bluetooth 4.2, USB data export |
| Compliance | Designed for ISO 14644, ISO 14645, EN 13779, and USP <797> environmental monitoring workflows |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Model | 6850+ |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Flow Rate Range | 0–999999 m³/h |
| Flow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Display | Full-color LCD |
| Data Storage | 10,000 records with USB export capability |
| Measurement Media | Air and non-corrosive gases |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6850+ |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Flow Rate Range | 0–999999 m³/h |
| Flow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power | 4 × AA batteries or DC 5 V adapter |
| Battery Life | >15 h |
| Weight (with batteries) | ≈360 g |
| Data Storage Capacity | 10,000 records |
| Interface | USB for direct data export to USB flash drive |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | GTI-115 |
| Pressure Type | Differential |
| Measurement Medium | Air |
| Pressure Range | –2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Wind Speed Range | 0.20–60.0 m/s |
| Wind Speed Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Wind Speed Resolution | 0.01 m/s |
| Airflow Range | 0–999999 m³/h |
| Airflow Resolution | 1 m³/h |
| Operating Temperature | 0–60°C (non-condensing) |
| Storage Temperature | –20–70°C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V AC adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Data Storage Capacity | 10,000 records |
| Data Export | USB flash drive |
| Display | Full-color TFT LCD |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KAN-VEH-SEAL |
| Pressure Range | ±2500 Pa |
| Measurable Air Leakage Rate | 1–200 L/s |
| Mounting | Flanged Interface to Vehicle Window |
| Static Pressure Monitoring Port | Integrated on Flange |
| Control Mode | Static Pressure Setpoint or Volumetric Leakage Rate Setpoint |
| Actuation | Variable-Speed Fan with Real-Time Feedback Compensation |
| Compliance | Designed for ISO 9001-aligned automotive cabin integrity verification |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6720-DP |
| Measurement Range | ±2500 Pa |
| Accuracy Class | 0.01 |
| Medium | Gas |
| Operating Temperature | 0–60 °C (non-condensing) |
| Differential Pressure Resolution | 0.001 Pa |
| Differential Pressure Accuracy | ±1.5% of reading ±0.25 Pa |
| Air Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Air Velocity Range (with Air Velocity Matrix) | 0.15–15 m/s |
| Air Velocity Accuracy | ±3% of reading ±0.05 m/s (>0.25 m/s) |
| Air Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 readings (mobile app) |
| Power | 4 × AA batteries (~14 h continuous operation), DC 5 V input |
| Weight | ~390 g |
| Communication | Bluetooth 4.2, USB data export |
| Brand | KANOMAX |
|---|---|
| Origin | China (Liaoning) |
| Model | 6720-DP |
| Pressure Range | –2500 to +2500 Pa |
| Accuracy (Pressure) | ±1.5% of reading ±0.25 Pa |
| Resolution (Pressure) | 0.001 Pa |
| Air Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Air Velocity Range (with Air Velocity Matrix) | 0.15–15 m/s |
| Accuracy (Velocity) | ±3% of reading ±0.05 m/s (>0.25 m/s) |
| Resolution (Velocity) | 0.01 m/s |
| Display | 4.3-inch full-color capacitive touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 (mobile app) |
| Battery Life | ~14 h (4 × AA alkaline) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Weight | ~390 g |
| Communication | Bluetooth 4.2, USB data export |
| Compliance | Designed for ISO 14644, ISO 14645, NSF/ANSI 49, and EN 1822 test workflows |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6720-DP |
| Pressure Range | –2500 to +2500 Pa |
| Accuracy | ±1.5% of reading ±0.25 Pa |
| Resolution | 0.001 Pa |
| Air Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Air Velocity Accuracy | ±3% of reading ±0.05 m/s (for v > 0.25 m/s) |
| Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 (mobile app) |
| Power | 4 × AA batteries (≈14 h operation) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Weight | ≈390 g |
| Communication | Bluetooth 5.0, USB data export |
| Compliance | Designed for ISO 14644, ISO 14645, NSF/ANSI 49, and EU GMP Annex 1 environmental monitoring workflows |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6720-DP |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±1.5% of reading ±0.25 Pa |
| Resolution | 0.001 Pa |
| Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (for v > 0.25 m/s) |
| Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (instrument), 10,000 records (mobile app) |
| Power | 4 × AA batteries (≈14 h continuous operation) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Weight | ≈390 g |
| Communication | Bluetooth 4.2, USB data export |
| Compliance | Designed for ISO 14644, ISO 14645, NSF/ANSI 49, and EU GMP Annex 1 environmental qualification workflows |
| Brand | KANOMAX |
|---|---|
| Model | 6720-DP |
| Measurement Range | ±2500 Pa |
| Accuracy Class | 0.01 |
| Medium | Gas |
| Operating Temperature | 0–60 °C (non-condensing) |
| Display | 4.3-inch full-color touchscreen |
| Resolution | 0.001 Pa (differential pressure), 0.01 m/s (velocity) |
| Battery Life | ~14 h (4 × AA batteries) |
| Data Storage | 8,000 records (instrument), 10,000 records (mobile app) |
| Wind Velocity Range | 0.15–40 m/s (with Pitot tube), 0.15–15 m/s (with velocity matrix) |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (>0.25 m/s) |
| DP Accuracy | ±1.5% of reading ±0.25 Pa |
| Weight | ~390 g |
| Brand | KANOMAX |
|---|---|
| Model | 6720-DP |
| Pressure Range | ±2500 Pa |
| Accuracy | ±1.5% of reading ±0.25 Pa |
| Resolution | 0.001 Pa |
| Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (for v > 0.25 m/s) |
| Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 readings (instrument), 10,000 readings (mobile app) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Power | 4 × AA batteries (≈14 h continuous use) |
| Communication | Bluetooth 4.2, USB data export |
| Weight | ≈390 g |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Model | 6720-DP |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±1.5% of reading ±0.25 Pa |
| Resolution | 0.001 Pa |
| Velocity Range (with Pitot Tube) | 0.15–40 m/s |
| Velocity Accuracy | ±3% of reading ±0.05 m/s (for v > 0.25 m/s) |
| Velocity Resolution | 0.01 m/s |
| Display | 4.3-inch full-color touchscreen |
| Data Storage | 8,000 records (device), 10,000 records (mobile app) |
| Operating Temperature | 0–60 °C (non-condensing) |
| Power | 4 × AA batteries (≈14 h continuous use) |
| Communication | Bluetooth 5.0, USB data export |
| Weight | ≈390 g |