| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP300 |
| Instrument Type | Fluoropolymer Distillation System |
| Heating Method | PTC Semiconductor Heating |
| Cooling Method | Integrated Closed-Loop Cooler (No External Chiller Required) |
| Distillation Rate | 70 mL/h (for 65% HNO₃) |
| Ramp Time | 60 min (25°C to 110°C) |
| Endpoint Control | Precision Photoelectric Liquid-Level Sensor |
| Heating Element | PTC Semiconductor Heater |
| Material Construction | PFA/PTFE-lined Chamber & Fluid Pathways |
| Safety Features | Dual Liquid-Level Monitoring (Feed/Pure Acid), Dry-Run & Overflow Prevention, Redundant Temperature Sensing, Onboard Acid Gas Neutralization System (99% Efficiency) |
| Dimensions | 38 × 35 × 60 cm (W × D × H) |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP300S |
| Instrument Type | Fluoropolymer (PTFE/PFA) Distillation Apparatus |
| Heating Method | PTC Semiconductor Heating |
| Cooling Method | Integrated Air-Cooled Condenser (No External Chiller Required) |
| Distillation Rate | 70 mL/h (for 65% HNO₃) |
| Ramp Time | 60 min (from 25°C to 110°C) |
| Endpoint Control | Precision Photoelectric Liquid-Level Sensor |
| Dual Independent Pump System | Acid Feed + Waste Drain |
| Safety Interlocks | Real-Time Level Monitoring (Crude Acid Low/High, Pure Acid Overflow), RTC Immersion Temperature Sensing, Self-Limiting PTC Thermal Regulation |
| Acid Vapor Recovery Efficiency | >99% (Integrated Neutralization & Adsorption) |
| Dimensions | 38 × 35 × 60 cm (W × D × H) |
| Material Contact Path | PTFE, PFA, and Quartz Only |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AP400 |
| Instrument Type | Fluoropolymer Distillation System |
| Heating Method | PTC Semiconductor Heating |
| Cooling Method | Integrated Closed-Circuit Cooler (No External Chiller Required) |
| Distillation Rate | 45 mL/h |
| Ramp Time | 60 min (Room Temperature to 110 °C) |
| Endpoint Control | Precision Photoelectric Liquid-Level Sensor |
| Heating Element | PTC Semiconductor Heater |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Analab |
|---|---|
| Origin | France |
| Device Type | Sub-boiling Distiller |
| Capacity | 12 × 125 mL |
| Construction | PFA-coated (400 µm thickness) |
| Compliance | ISO Class 1 Cleanroom Certified |
| Heating Uniformity | ±0.5 °C across surface |
| Operating Principle | Controlled sub-boiling evaporation with condensate isolation |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Quartz Glass Distillation Apparatus |
| Heating Method | Ceramic Heating Element |
| Cooling Method | External Tap Water or Recirculating Chiller |
| Distillation Rate | 1–8 mL/min |
| Heating Ramp Time | 0–5 min |
| Endpoint Detection | Precise Automatic Endpoint Control |
| Sample Capacity | 6 Independent Stations |
| Flow Control | 6-Channel Independent Flow Regulation |
| Standard Method Integration | Preloaded Chinese National Standards (e.g., HJ 1226-2021, GB/T 16489-1996) |
| Temperature Control Accuracy | ±1 °C (Dry-Block Heating) |
| Condensation Options | Air-Cooled, Water-Cooled, or Chiller-Coupled |
| Drain Function | One-Touch Condensate Drain |
| Interface | Backlit Capacitive Touchscreen (≥7″) |
| Liquid Handling | Automated Reagent Dosing & Volume Quantification |
| System Self-Cleaning | Integrated Liquid Pathway Rinse Cycle |
| Brand | Berghof |
|---|---|
| Origin | Germany |
| Model | BSB-939-IR |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Construction Materials | TFM-PTFE, PTFE, and PFA only (no quartz or metal components) |
| Application | Ultra-high-purity acid production for trace elemental analysis |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | CH-1000 |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Capacity | 1000 mL |
| Production Rate | 50 mL/h |
| Temperature Control | PID Digital Display |
| Temperature Accuracy | ±1 °C |
| Construction Materials | FEP, PTFE, Silicone |
| Voltage | 220 V / 50 Hz |
| Power | 350 W |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Model | NJ-CH-2 |
| Capacity | 1000 mL |
| Material of Construction | PTFE (Teflon®-lined or fully PTFE chamber) |
| Compliance | Designed for trace-metal-free acid purification per ASTM D511, ISO 17294-2, and USP <643> guidelines |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Model | NJ-CH-500ml |
| Capacity | 500 mL |
| Purification Principle | Radiant Heating Sub-Boiling Distillation |
| Compatible Acids | HCl, HNO₃, HF, NaOH (aq), and Selected Organic Solvents |
| Construction Material | PTFE (Teflon®) and High-Purity Quartz/Fused Silica Components |
| Compliance | Designed for ISO/IEC 17025 Trace Metal Analysis Environments |
| Software Interface | None (Manual Temperature Control) |
| Brand | Binzhenghong |
|---|---|
| Model | NJ-CH-II-1L |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sub-boiling Distillation System |
| Heating Method | Silicone Heater Pad |
| Distillation Rate | 50 mL/h |
| Heating Units | 1 |
| Warm-up Time | 30 min |
| Capacity | 1000 mL |
| Material Compatibility | HNO₃, HCl, HF, NaOH, and Organic Solvents |
| Construction | PTFE (Teflon)-lined Chamber and Condensation Pathway |
| Compliance | Designed for ISO/IEC 17025-aligned trace metal analysis workflows |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Models | 1000 mL, 2000 mL, 4000 mL |
| Heating Method | Silicone Rubber Heating Sleeve |
| Cooling Method | Passive Ambient Air Cooling |
| Distillation Rate | 50–100 mL/h (model-dependent) |
| Temperature Control | PID Digital Display with ±1 °C Accuracy |
| Max Operating Temperature | Up to 180 °C |
| Power Consumption | ≤400 W (1000 mL), ≤500 W (2000/4000 mL), Variable Frequency Adjustable |
| Voltage | 220 V / 50 Hz |
| Liquid Level Options | Triple-level (1000 mL), Quadruple-level (2000/4000 mL) |
| Material | All-Wetted Parts Constructed from High-Purity Perfluoroalkoxy (PFA) |
| Safety Features | Dry-run Protection, Overheat Cutoff, Integrated Ventilation-Cabinet Compatibility |
| Metal Impurity Reduction | From ~10 ppb to ≤0.01 ppb (single-pass, ICP-MS-grade acids) |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Models | NJ-SCH-1 (1 L), NJ-SCH-2 (2 L), NJ-SCH-4 (4 L) |
| Heating Method | Silicone Rubber Heater |
| Cooling Method | Ambient Air Cooling |
| Distillation Rate | 50–100 mL/h |
| Warm-up Time | 30 min |
| Power Consumption | ≤400 W (Model 1), ≤500 W (Models 2 & 4), Variable-Frequency Adjustable |
| Temperature Control | PID Digital Display with ±1 °C Accuracy |
| Voltage | 220 V / 50 Hz |
| Liquid Level Options | 200/600/1000 mL |
| Material | High-Purity PFA (Perfluoroalkoxy Alkane) for All Wetted Parts |
| Safety Features | Dry-run Protection, Overheat Cutoff, Ventilation-Cabinet Compatible Operation |
| Metal Impurity Reduction | From ~10 ppb to ~0.01 ppb in Single-Stage Distillation |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sub-boiling Distillation Purifier |
| Model Variants | NJ-SCH-1 (1 L), NJ-SCH-2 (2 L), NJ-SCH-4 (4 L), NJ-SCH-6 (6 L) |
| Heating Method | Silicone Rubber Heater Sleeve with Overheat Protection |
| Cooling Method | Passive Ambient Air Cooling |
| Distillation Rate | 50 mL/h (for 1000 mL unit) |
| Temperature Control | PID Digital Controller with ±1 °C Accuracy |
| Operating Voltage | 220 V / 50 Hz |
| Material of Wetted Parts | High-Purity PFA (Perfluoroalkoxy Alkane) |
| Max. Working Temperature | 180 °C |
| Liquid Level Options | 200 / 600 / 1000 mL |
| Power Consumption | ≤400 W (Variable-Frequency Adjustable) |
| Brand | Binzhenghong |
|---|---|
| Model | NJ-SCH-II / NJ-SCH-III / NJ-SCH-IV |
| Capacity | 1 L / 2 L / 4 L |
| Acid Output Rate | 50 mL/h / 70 mL/h / 100 mL/h |
| Heating Method | Silicone Rubber Heater (Fully Enclosed, Overheat Protected) |
| Temperature Control | PID Digital Display, ±1 °C Accuracy |
| Max Operating Temp | Up to 180 °C |
| Cooling | Ambient Air Cooling (No External Water Required) |
| Power | ≤400 W (NJ-SCH-II) / ≤500 W (NJ-SCH-III & IV), Variable-Frequency Adjustable |
| Voltage | 220 V / 50 Hz |
| Wetted Materials | High-Purity PFA Only (Metal-Free Construction) |
| Liquid Level Options | 200/600/1000 mL |
| Dry-Out Protection | Yes |
| Collection Vessel | GL45-threaded PFA Bottle (Stretch-Blown, Seal-Intact Without Inner Cap) |
| Metal Impurity Reduction | From ~10 ppb → ~0.01 ppb (Single-Pass Distillation) |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NJ-SCH-I-1000ml |
| Instrument Type | Sub-boiling Distillation Unit |
| Heating Method | PID-Controlled Silicone Heater Sleeve |
| Cooling Method | Integrated Air-Cooled Condenser |
| Distillation Rate | 50 mL/h |
| Ramp-up Time | 30 min |
| Endpoint Control Capacity | 1000 mL |
| Heating Element | Cylindrical Silicone Rubber Heating Pad |
| Temperature Control Accuracy | ±1 °C |
| Construction Material | All-Wetted Parts in High-Purity PFA |
| Compliance | Designed for ISO/IEC 17025-aligned trace metal analysis workflows |
| Power Supply | 220 V / 50 Hz |
| Max. Power Consumption | ≤400 W (Variable-Frequency Adjustable) |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Heating Method | Silicone Rubber Heating Sleeve |
| Cooling Method | Ambient Air Cooling (No External Water Supply Required) |
| Distillation Rate | 70 mL/h |
| Temperature Control Range | Up to 180 °C (PID Digital Controller, ±1 °C Accuracy) |
| Power Consumption | ≤500 W (Variable Frequency Adjustable) |
| Voltage/Frequency | 220 V / 50 Hz |
| Liquid Capacity Options | 500 / 1000 / 1500 / 2000 mL |
| Material of Construction | High-Purity Perfluoroalkoxy (PFA) for All Fluid-Wetted Components |
| Compliance | Designed for Trace-Metal-Free Acid Purification per ASTM D512, ISO 17025-aligned operation, and GLP/GMP traceability requirements |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | NJ-SCH-I (1000 mL), NJ-SCH-II (2000 mL) |
| Instrument Type | Sub-boiling Distillation Apparatus |
| Heating Method | Silicone Heater Pad |
| Distillation Rate | 70 mL/h (NJ-SCH-II), 50 mL/h (NJ-SCH-I) |
| Warm-up Time | ≤60 min |
| Temperature Control | PID Digital Display with ±1 °C Accuracy |
| Voltage | 220 V / 50 Hz |
| Power Consumption | ≤400 W (Variable-Frequency Adjustable) |
| Construction Material | Entire Distillation Pathway in Transparent PFA |
| Compliance | Metal-Free Architecture, Suitable for Ultra-Trace Elemental Analysis |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Origin Category | Domestic |
| Model | ZL-250ml |
| Instrument Type | Fluoropolymer Distillation Apparatus |
| Heating Method | Water Bath or Oil Bath |
| Cooling Method | Integrated Air-Cooled Condensation |
| Material | Perfluoroalkoxy (PFA) |
| Capacity | 250 mL |
| Standard Joint Size | 19# or 24# |
| Configuration | Single-Neck with Optional Multi-Neck Adaptability (up to 4 necks) |
| Compatible Components | PFA Round-Bottom Flask, Constant-Pressure Dropping Funnel, Gas Scrubbing Bottle, PFA Thermometer Sleeve, Magnetic Stirrer Shaft Port, Customizable Separatory Funnel |
| Brand | Bode |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | BLC-12 |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Producer |
| Country of Origin | Domestic (China) |
| Model | BLC-8 |
| Pricing | Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Silicone Heater Pad |
| Cooling Method | Natural Air Cooling |
| Distillation Rate | 50 mL/h |
| Warm-up Time | 30 min |
| Power Consumption | ≤350 W (Variable Frequency Control) |
| Temperature Control | PID Digital Display |
| Temp. Accuracy | ±1 °C |
| Voltage | 220 V / 50 Hz |
| Material | All-PFA (Perfluoroalkoxy) Construction |
| Collection Volume | 1000 mL |
| Metal Impurity Reduction | From ~10 ppb to ~0.01 ppb (single-pass) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Auto-Continuous Distillation & Fractional Distillation System |
| Construction Material | Quartz Glass |
| Vacuum Performance | ≤10⁻⁶ mbar |
| Column Design | Vacuum-Silvered Double-Jacketed Column with Linear Observation Window and Thermal-Stress-Compensating Corrugated Expansion Section |
| Reflux Control | Programmable Electromagnetic Valve with PID-Controlled Reflux Ratio Setting |
| Automation Core | PLC-Based Control System Integrated with Quartz Fiber-Optic Level Sensor, Precision Temperature Sensors (Pt100), Absolute Vacuum Transducer, and Peristaltic Feed Pump |
| System Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | SHZ32-50 |
| Output | 50 L/h |
| Water Consumption Ratio | ≤1:14 |
| Weight | 90 kg |
| Dimensions (W×D×H) | 700×700×1000 mm |
| Construction Material | 304 Stainless Steel |
| Cooling System | Inline Water-Cooled Condenser |
| Heating System | Helical (Spiral) Electric Heating Element |
| Compliance | Chinese Pharmacopoeia (2000 Edition) for Purified Water |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | YA.ZD-20 |
| Output Capacity | 20 L/h |
| Power Supply | 380 V AC |
| Heating Power | 15 kW |
| Net Weight | 10 kg |
| Dimensions (L×W×H) | 900 × 360 × 370 mm |
| Construction Material | AISI 304 Stainless Steel |
| Control Type | Manual Flow Regulation |
| Distillation Type | Single-Stage Electric Steam Distillation |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YN-ZD-5 / YN-ZD-10 / YN-ZD-20 |
| Output Rate | 5 L/h / 10 L/h / 20 L/h |
| Power Supply | 220 V AC (YN-ZD-5) or 380 V AC (YN-ZD-10 & YN-ZD-20) |
| Heating Power | 4.5 kW / 7.5 kW / 15 kW |
| Construction Material | 304 Stainless Steel |
| Safety Feature | Automatic Dry-run Protection with Imported Sensor |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YN-ZD-Z-5 / YN-ZD-Z-10 / YN-ZD-Z-20 |
| Output Capacity | 5 L/h / 10 L/h / 20 L/h |
| Input Voltage | 220 V AC (all models) |
| Heating Power | 4.5 kW (all models) |
| Construction Material | AISI 304 stainless steel |
| Safety Certification | Compliant with GB/T 14710–2009 (Chinese National Standard for Environmental Adaptability of Medical Electrical Equipment) |
| Cooling Method | Recirculating tap water |
| Protection Mechanism | Imported dry-run sensor with automatic power cutoff |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Model | ZLSC-20 / ZLSC-10 / ZLSC-5 |
| Output Capacity | 5 L/h / 10 L/h / 20 L/h |
| Power Supply | 380 V AC |
| Power Consumption | 9 kW / 15 kW / 24 kW |
| Net Weight | 14–15 kg |
| Dimensions (W×D×H) | 770×380×860 mm (ZLSC-5/ZLSC-10), 860×380×860 mm (ZLSC-20) |
| Construction Material | ASTM A240 304 stainless steel |
| Safety Features | Dry-run auto-shutoff, water-level monitoring circuit, insulated control panel guard |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZLSC-5 |
| Instrument Category | Fluoropolymer-Lined Distillation Apparatus |
| Output Capacity | 5 L/h |
| Power Supply | 380 V AC |
| Heating Power | 9 kW |
| Net Weight | 14 kg |
| Dimensions (W×D×H) | 770 × 380 × 860 mm |
| Construction Material | AISI 304 Stainless Steel |
| Safety Features | Dual-level dry-run protection, thermal cutoff, insulated control panel shield, adjustable dual-direction flow valve, internal分流-type condensate separation structure |
| Compliance | Designed for GLP-compliant laboratory water purification |
| Brand | Chuanyu Instruments (chuanyuyiqi) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | CHSO2-4 |
| Instrument Category | Standard Quartz Glass Distillation Apparatus |
| Heating Method | Enclosed Infrared Ceramic Heating Mantles |
| Cooling Method | External Tap Water or Integrated Recirculating Chiller (Optional) |
| Distillation Rate | 15 mL/min |
| Heating Ramp Time | 8–15 min |
| Endpoint Control | Programmable Timer |
| Heating Stations | 4-position |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-ZLA |
| Price | USD 1,400 (FOB) |
| Heating Method | Far-Infrared Ceramic Radiant Heater (Flame-Free) |
| Cooling Method | External Chilled Water Circulator or Tap Water |
| Warm-up Time | <20 min |
| Distillation Endpoint Control | Time-Based & Mass-Based Dual Mode |
| Heating Units | 6 Independent Channels |
| Maximum Heating Power per Channel | 600 W |
| Rated Total Power | 3800 W |
| Operating Temperature Range | Ambient to 400 °C |
| Distillation Volume Range | 0–500 mL |
| Precision | ±0.1 mL |
| Distillation Flow Rate | 0–10 mL/min |
| Display | 7-inch Full-Color TFT Touchscreen |
| Built-in Methods | 18 Preloaded Standard Methods (e.g., HJ 537, HJ 1226, GB 5009.266) |
| Method Storage Capacity | ≤1000 Protocols |
| Safety Features | Anti-Suckback Valve, Overheating Protection, Dry-Run Prevention (Dual-Temperature + Flow Monitoring), Automatic Pressure Release, Leakage Current Protection |
| Auto-Cleaning Function | Yes |
| Airtightness Verification | Yes |
| OTA Firmware Update | Yes |
| Dimensions (W×D×H) | 920 × 417 × 555 mm |
| Net Weight (w/ Glassware) | 75 kg |
| Power Supply | 220 V, 50 Hz |