Carbon Dioxide Incubator
Filter
Showing 1–30 of 190 results
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BD Series |
| Capacity Range | 20–720 L |
| Temperature Range | Ambient +5 °C to 100 °C |
| Heating Technology | APT.line™ Preheating Chamber Technology |
| Air Circulation | Natural Convection |
| Ventilation | Adjustable 50 mm Rear Vent with Manual Dampers |
| Controller | DS Digital Controller with 99-h Timer |
| Temperature Resolution | 0.1 °C |
| Independent Temperature Safety Device | Class 3.1 per DIN 12880 |
| Door | Sealed Double-Glass Inner Door |
| Standard Accessories | 2 Adjustable Stainless-Steel Shelves |
| Stackability | Models ≤115 L Stackable |
| Interface | RS422 for APT-COM Software Integration |
| Certification | Factory-Tested & Supplied with BINDER Test Report |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| Temperature Range & Accuracy | Ambient +4–7 °C to 60 °C |
| Temperature Uniformity | ±0.4 °C |
| Humidity Control Range & Accuracy | 90–95 % RH |
| Chamber Volume | 267 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB |
| Internal Volume (L) | 53 / 170 / 260 |
| Net Weight (kg, empty) | 53 / 98 / 125 |
| Max Total Load (kg) | 30 / 30 / 40 |
| Max Load per Shelf (kg) | 10 / 10 / 10 |
| Rear Wall Clearance (mm) | 100 / 100 / 100 |
| Side Wall Clearance (mm) | 50 / 50 / 50 |
| Internal Dimensions (W×H×D, mm) | 400×400×330 / 560×600×505 / 620×750×575 |
| External Dimensions (W×H×D, mm) | 528×674×545 / 680×870×715 / 740×1020×785 |
| Temp. Range | RT+4–6°C to 60°C |
| Temp. Uniformity (±K @37°C) | 0.3 / 0.3 / 0.4 |
| Temp. Stability (±K @37°C) | 0.1 / 0.1 / 0.13 |
| Humidity Range | 90–95% RH |
| CO₂ Range | 0–20 vol.% |
| CO₂ Measurement Principle | Single-beam IR sensor |
| Recovery Time after 30-sec Door Opening (min @37°C) | 5 / 6 / 6 |
| Rated Power (230 V, kW) | 0.8 / 1.4 / 1.5 |
| Standard/Max Shelf Quantity | 2/3 / 3/6 / 3/8 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB Series |
| Sterilization | Dry-heat sterilization (180 °C, 2–4 h) |
| CO₂ Control Range | 0–20 % (±0.1 % typical accuracy) |
| Temperature Range | Ambient +5 °C to 50 °C (±0.1 °C stability at 37 °C) |
| Humidity Control | Active humidification with integrated water pan and saturation monitoring |
| Chamber Volume Options | 53 L to 216 L |
| Construction | Stainless steel interior (AISI 304), double-wall insulated chamber, HEPA-filtered air circulation (ISO Class 5 compliant) |
| Compliance | IEC 61010-1, EN 61326-1, CE marked for in vitro diagnostic use (IVDR Annex II) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB-S Solid.Line |
| Internal Volume (L) | 170 / 267 |
| Net Weight (kg, empty) | 96 / 122 |
| Max. Total Load (kg) | 30 / 40 |
| Max. Load per Shelf (kg) | 10 / 10 |
| Rear Clearance (mm) | 100 / 100 |
| Side Clearance (mm) | 50 / 50 |
| Internal Dimensions – W×H×D (mm) | 560×600×505 / 620×750×575 |
| External Dimensions – W×H×D (mm) | 680×870×715 / 740×1020×785 |
| Temp. Range | Ambient +6 °C to 50 °C |
| Temp. Uniformity (±K @37 °C) | 0.3 / 0.4 |
| Temp. Stability (±K @37 °C) | 0.1 / 0.13 |
| Recovery Time (min @37 °C, 30 s door open) | 6 / 8 |
| Humidity Range | 90–95 % RH |
| CO₂ Range | 0–20 vol.% |
| CO₂ Sensing Principle | Infrared (IR) |
| Rated Power (230 V) | 1.3 kW / 1.5 kW |
| Standard/Max. Shelves | 2 / 6 or 2 / 8 |
| Sterilization | Dry-heat at 180 °C |
| Interface | Ethernet, USB, Dry Contact Alarm Output |
| Data Logging | Internal, USB exportable |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Water-Jacketed CO₂ Incubator |
| Model | CB 170 |
| Temperature Range & Accuracy | Ambient +4 °C to 60 °C |
| Temperature Uniformity | ±0.3 °C |
| CO₂ Concentration Range & Accuracy | 0–20 vol.% |
| Humidity Control Range & Accuracy | 90–95 %RH |
| Chamber Capacity | 170 L |
| External Dimensions (W×H×D) | 680 × 870 × 715 mm |
| Sterilization Method | 180 °C Dry-Heat Sterilization |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB53 / CB150 / CB210 |
| Temperature Range | Ambient +7 °C to 60 °C |
| Temperature Uniformity | ±0.1 °C (at 37 °C) |
| CO₂ Range | 0–20 vol.% |
| O₂ Range (Tri-gas models) | 0.2–95 vol.% |
| Humidity | ≥95 % RH (Permadry® dual-disk system) |
| Chamber Volume | 53 L / 150 L / 210 L |
| Sterilization | 180 °C hot-air (DIN 58947) |
| CO₂ Sensing | Non-drift IR sensor |
| O₂ Sensing | Zirconia (ZrO₂) sensor |
| Control System | MCS microprocessor controller with LCD interface, real-time clock, and electronic chart recorder |
| Communication | RS 422 (APT-COM® compatible) |
| Construction | Seamless deep-drawn stainless steel chamber (1.4301 / AISI 304) |
| Safety | Independent temperature safety device (DIN 12880 Class 3.1), visual/audible alarms, self-diagnostic system |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CBF Series |
| Internal Volume | 170 L / 267 L |
| Net Weight (empty) | 95 kg / 125 kg |
| Max. Total Load | 30 kg / 40 kg |
| Max. Load per Shelf | 10 kg |
| Rear Wall Clearance | 100 mm |
| Side Wall Clearance | 50 mm |
| Internal Dimensions (W×H×D) | 560×600×505 mm / 620×750×575 mm |
| External Dimensions (W×H×D) | 680×870×715 mm / 740×1020×785 mm |
| Temp. Range | RT + 6 °C to 60 °C |
| Temp. Uniformity | ±0.4 K @ 37 °C |
| Temp. Stability | ±0.1 K @ 37 °C |
| Temp. Recovery Time (30 s door open) | 6 min @ 37 °C |
| Humidity Range | 50–95 %RH |
| CO₂ Range | 0–20 vol.% |
| CO₂ Sensing Principle | Single-beam IR |
| Rated Power (230 V) | 1.4 kW / 1.5 kW |
| Standard/Max. Shelves | 3/6 or 3/8 |
| Sterilization | 180 °C dry-heat |
| Chamber Material | Seamless stainless steel with shelf reinforcement system |
| Gas Mixing | Venturi-type CO₂ injection nozzle |
| Control Interface | Touchscreen controller with USB data export, Ethernet, zero-voltage alarm contacts |
| Data Logging | Internal recorder with open-format measurement values |
| Safety Systems | CO₂ Fail-Safe pH monitoring, optical & acoustic fault diagnostics |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Range & Accuracy | Ambient +6 °C to 50 °C |
| Temperature Uniformity | ±0.3 °C |
| CO₂ Concentration Range & Accuracy | 0–20 % vol |
| Humidity Control | Maintained at 37 °C (Relative Humidity ≥95% RH, typical) |
| Chamber Capacity | 170 L |
| External Dimensions (W×H×D) | 680 × 870 × 715 mm |
| Sterilization Method | Automatic 180 °C Dry-Heat Decontamination Cycle |
| Chamber Construction | Seamless, Weld-Free Stainless Steel Interior |
| Gas Mixing Principle | Venturi-Based Pre-Mixed CO₂ Inlet System |
| Humidification System | Condensation-Protected Water Reservoir with Evaporative Humidification |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BC-J160 (Gas-Jacketed, Thermal Conductivity Detection) |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Stability | ≤ ±0.2°C |
| Temperature Resolution | 0.1°C |
| CO₂ Range | 0–19.9% |
| CO₂ Sensing Method | Thermal Conductivity Detector (TCD) |
| CO₂ Recovery Time | ≤ (setpoint %) × 2 minutes |
| Chamber Volume | 160 L |
| Internal Dimensions (W×D×H) | 540 × 490 × 680 mm |
| External Dimensions (W×D×H) | 700 × 650 × 1030 mm |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 800 W |
| Humidification Method | Natural Evaporation |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm (dual HEPA filters) |
| Display | High-brightness LCD with simultaneous real-time display of temperature and CO₂ concentration |
| Safety Features | Dual independent temperature control systems, over-temperature audible/visual alarm, door-heating anti-condensation system, power-failure data retention and auto-recovery |
| Interface | RS-485 for PC or data logger connectivity |
| Optional Accessories | Thermal printer (curve printing), GPRS SMS alert module, remote PC monitoring software |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% |
| Capacity | 160 L |
| External Dimensions (W×D×H) | 700 × 650 × 1030 mm |
| Internal Chamber Dimensions (W×D×H) | 540 × 490 × 680 mm |
| Temperature Stability (Fluctuation) | ≤ ±0.2°C |
| Temperature Resolution | 0.1°C |
| CO₂ Recovery Time | ≤ (Setpoint %) × 1.2 min |
| Humidification Method | Natural Evaporation |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 800 W |
| Standard Shelving | 3 Adjustable Stainless Steel Shelves |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm (Dual HEPA-grade Filters) |
| Interface | RS-485 for PC/Logger Connectivity |
| Data Protection | Power-Failure Parameter Memory & Auto-Restore Function |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | BC-J160S (Water-Jacketed, Infrared CO₂ Sensor) |
| Temperature Range & Accuracy | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C at 37°C |
| Chamber Capacity | 160 L |
| CO₂ Range | 0–20% |
| CO₂ Recovery Time | ≤ (setpoint %) × 1.2 min |
| Temperature Fluctuation | ≤ ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Humidification Method | Natural Evaporation |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 900 W |
| Internal Dimensions (W×D×H) | 540 × 490 × 680 mm |
| External Dimensions (W×D×H) | 682 × 611 × 1090 mm |
| Shelving | 3 Adjustable Stainless Steel Shelves |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm |
| Interface | RS-485 for PC/Recorder Integration |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BC-J250 (Gas-Jacketed, Infrared CO₂ Sensing) |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Chamber Volume | 250 L |
| CO₂ Range | 0–20% |
| CO₂ Sensor Type | Infrared (IR) |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ≤ ±0.2°C |
| CO₂ Recovery Time | ≤ (Setpoint %) × 1.2 min |
| Humidification Method | Natural Evaporation |
| Internal Dimensions (W×D×H) | 600 × 600 × 770 mm |
| External Dimensions (W×D×H) | 840 × 775 × 1175 mm |
| Shelf Capacity | 3 Adjustable Stainless Steel Shelves |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 850 W |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm (Dual HEPA-grade filters) |
| Interface | RS-485 for external data logging or PC integration |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BC-J250 (Gas-Jacketed, Thermal Conductivity Detector) |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Stability | ≤ ±0.2°C |
| Temperature Resolution | 0.1°C |
| CO₂ Range | 0–19.9% (v/v) |
| CO₂ Control Method | Thermal Conductivity Detection (TCD) |
| CO₂ Recovery Time | ≤ [setpoint %] × 2 minutes |
| Chamber Volume | 250 L |
| Internal Dimensions (W×D×H) | 600 × 600 × 770 mm |
| External Dimensions (W×D×H) | 840 × 775 × 1175 mm |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 850 W |
| Humidification Method | Natural Evaporation |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm |
| Number of Shelves | 3 adjustable stainless steel shelves |
| Interface | RS-485 for external data logging or PC integration |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BC-J80 (Gas-Jacketed, TCD-based CO₂ Control) |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Fluctuation | ≤ ±0.2°C |
| Temperature Resolution | 0.1°C |
| CO₂ Range | 0–19.9% |
| CO₂ Control Method | Thermal Conductivity Detector (TCD) |
| CO₂ Recovery Time | ≤ (setpoint %) × 2 minutes |
| Chamber Volume | 80 L (nominal) |
| Internal Dimensions (W×D×H) | 420 × 400 × 550 mm |
| External Dimensions (W×D×H) | 580 × 560 × 900 mm |
| Shelf Capacity | 2 adjustable stainless-steel shelves |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 700 W |
| Humidification Method | Natural Evaporation |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm (dual-stage HEPA filtration) |
| Sterilization Mode | 90°C high-humidity thermal decontamination |
| Interface | RS-485 for PC/data logger connectivity |
| Backup Function | Parameter memory with power-fail recovery |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | BC-J80 (Water-Jacketed, Infrared CO₂ Sensing) |
| Temperature Range & Accuracy | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C at 37°C |
| Chamber Capacity | 80 L |
| CO₂ Range | 0–20% |
| CO₂ Sensor Type | Imported Infrared (IR) Sensor |
| CO₂ Recovery Time | ≤ (Setpoint %) × 1.2 min |
| Temperature Fluctuation | ≤ ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Humidity Control | Natural Evaporation |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 600 W |
| Chamber Dimensions (W×D×H) | 420 × 400 × 550 mm |
| External Dimensions (W×D×H) | 562 × 521 × 960 mm |
| Shelving | 2 Adjustable Stainless Steel Trays |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm |
| Interface | RS-485 for PC/Logger Connectivity |
| Backup Function | Power-Fail Parameter Memory & Auto-Restore |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Dual-Wavelength Infrared (IR) Sensor |
| Temperature Range & Accuracy | RT+3°C to 60°C, ±0.05°C stability, ≤±0.25°C uniformity |
| CO₂ Concentration Range & Accuracy | 0–20% vol, ±0.1% (full scale) |
| Humidity Control | High-Humidity Mode >90% RH, Low-Humidity Mode >80% RH |
| Chamber Volume | 185 L |
| External Dimensions (W×D×H) | 685 × 700 × 870 mm |
| Internal Dimensions (W×D×H) | 500 × 570 × 650 mm |
| Standard Configuration | 150°C Dry-Heat Sterilization, High-Efficiency Air Filtration (HEPA + 0.2 µm inlet filter), Triple-Zone Heated Air Jacket, BRIGHT II Touch Interface (7″ HD) |
| Brand | -- |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | BC-J80 |
| Quotation | Upon Request |
| Temperature Control Range & Accuracy | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.1°C (at 37°C) |
| Chamber Capacity | 80 L |
| CO₂ Control Range | 0–20% (v/v) |
| CO₂ Sensor Type | Infrared (NDIR) |
| CO₂ Recovery Time | ≤ Concentration Value × 1.2 min |
| Humidity Control | Natural Evaporation |
| Humidity Display | Yes (Capacitive Sensor) |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ≤ ±0.2°C at 37°C |
| Heating Method | Water-Jacketed |
| Internal Dimensions (W×D×H) | 420 × 400 × 550 mm |
| External Dimensions (W×D×H) | 562 × 521 × 960 mm |
| Net Weight | 51 kg |
| Gross Weight | 61 kg |
| Standard Shelving | 2 adjustable stainless-steel shelves (max 4) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 600 W |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm (HEPA-grade) |
| Communication Interface | RS-485 (1 port) |
| Data Protection | Auto-save on power interruption |
| Door Heating | Yes (anti-condensation) |
| Sterilization | Integrated UV lamp (254 nm) |
| Brand | Brookfield |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BC-J80 (Gas-Jacketed, Infrared CO₂ Sensing) |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Fluctuation | ≤ ±0.2°C |
| Temperature Resolution | 0.1°C |
| CO₂ Range | 0–20% vol |
| CO₂ Sensor Type | Infrared (IR) |
| CO₂ Recovery Time | ≤ (setpoint %) × 1.2 min |
| Chamber Volume | 80 L (nominal) |
| Internal Dimensions (W×D×H) | 420 × 400 × 550 mm |
| External Dimensions (W×D×H) | 580 × 560 × 900 mm |
| Shelf Capacity | 2 adjustable stainless-steel shelves |
| Humidification Method | Natural Evaporation |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 700 W |
| Interface | RS-485 for external data logging or PC integration |
| Optional Accessories | Thermal printer (curve printing), GPRS SMS alarm module, PC remote monitoring system |
| Brand | Brookfield |
|---|---|
| Origin | Netherlands |
| Model | BCI-180P |
| Capacity | 180 L |
| Temperature Uniformity | ±0.3 °C (at 37 °C / RT 20 °C) |
| Temperature Range | +20 to +60 °C |
| Temperature Resolution | 0.1 °C |
| CO₂ Range | 0–20 % |
| CO₂ Accuracy | ±0.1 % (at 5 %, 37 °C) |
| CO₂ Resolution | 0.1 % |
| CO₂ Sensor | Dual-beam infrared sensor |
| Sterilization | Dry-heat up to ≤125 °C |
| Heating Power | 320 W |
| CO₂ Inlet Pressure | 0.3–0.5 bar |
| Shelf Capacity | 3 standard / up to 8 optional |
| Internal Dimensions (W×D×H) | 473 × 528 × 710 mm |
| External Dimensions (W×D×H) | 560 × 620 × 945 mm |
| Net Weight | 85 kg |
| Jacket Type | Air-jacketed (6-sided gradient heating) |
| Chamber Material | AISI 304 stainless steel |
| Display | TFT touch screen |
| Control System | Digital PID |
| Brand | Chuanna Instrument |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +5°C to 65°C |
| Temperature Uniformity | ±0.2°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% |
| Chamber Capacity | 80 L |
| Standard Configuration | 90°C Humidified Sterilization Cycle |
| Brand | Chuanyu |
|---|---|
| Origin | Shanghai, China |
| Model | ZDX-100-CO₂ |
| Instrument Type | Air-jacketed CO₂ incubated shaker |
| CO₂ Detection | Infrared (IR) sensor |
| Temperature Range & Accuracy | RT + 5°C to 50°C, ±0.5°C |
| Temperature Uniformity | ±1.0°C |
| CO₂ Concentration Range & Accuracy | 0–20% v/v, ±0.5% |
| Humidity Range & Accuracy | 40–95% RH |
| Capacity | 100 L |
| External Dimensions (W×D×H) | 500 × 500 × 400 mm |
| Tray Size | 200 × 200 mm |
| Speed Range | 40–300 rpm |
| Orbit Diameter | ≥20 mm |
| Sterilization | Built-in UV lamp |
| Control Interface | Microprocessor-based LCD with menu-driven operation |
| Power Backup Function | Power-loss memory and automatic time compensation |
| Safety Features | Over-temperature alarm, real-time CO₂ monitoring, insulated tempered-glass door |
| Brand | Shanghai Shiping |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Sensing Method | Gas-Phase Infrared Detection |
| Temperature Range & Accuracy | RT+3°C to 60°C, ±0.1°C |
| Temperature Uniformity | ±0.3°C (at 37°C) |
| CO₂ Concentration Range & Accuracy | 0–20%, ±0.1% |
| Humidity Control | ≥95% RH (via water-jacketed humidification) |
| Chamber Volume | 175 L |
| External Dimensions (W×D×H) | 680 × 685 × 900 mm |
| Sterilization Mode | 90°C High-Temperature Humid Heat Cycle |
| Compliance | ISO 9001 Certified Manufacturing |
| Key Features | 7-inch Color Touchscreen (Bilingual UI), Triple-Level User Access Control, HEPA-Filtered Air Circulation (ISO Class 5 / Grade A Equivalent), 304 Mirror-Finish Stainless Steel Interior, Forced-Air Convection with Optimized Duct Design, Outer Door Heating, USB Data Export & Audit Trail Logging |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +3°C to 55°C (at 25°C ambient), ±0.1°C at 37°C |
| Temperature Uniformity | ±0.3°C at 37°C (25°C ambient) |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% at 5% CO₂ (37°C) |
| Dimensions | Cultiv8150 — Depth 560 mm × Width 540 mm × Height 580 mm |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CHP-80S |
| Capacity | 80 L |
| Temperature Range | RT+5 to 60 °C |
| Temperature Uniformity | ±1 °C |
| CO₂ Range | 0–20 % |
| CO₂ Control Accuracy | ±0.1 % (with infrared sensor) |
| CO₂ Uniformity | ±0.1 % at 5 % setting |
| CO₂ Recovery Time | ≤ concentration value × 1.2 min |
| Heating Method | Water-jacketed (S-series) |
| Power Consumption | ≤500 W |
| Working Environment | +5 to +35 °C |
| Voltage/Frequency | 220 V AC, 50 Hz |
| Chamber Dimensions (W×D×H) | 500 × 400 × 400 mm |
| External Dimensions (W×D×H) | 550 × 510 × 840 mm |
| Standard Shelving | 2 adjustable stainless steel shelves |
| Interior Material | Antibacterial stainless steel with rounded corners |
| CO₂ Inlet Filtration | HEPA-grade microbial filter (≥99.99 % efficiency for particles ≥0.3 µm) |
| UV Sterilization | Rear-mounted ultraviolet lamp |
| Door Design | Heated inner glass door to prevent condensation |
| Control System | Microprocessor-based intelligent controller with LCD display |
| Optional Interface | RS-485 port for data logging (printer/PC connectivity) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 15–45 °C (with humidity), 10–45 °C (without humidity) |
| Temperature Uniformity | Not specified |
| CO₂ Concentration Range | 0–20% |
| Humidity Control Range | 50–85% RH (customizable to 40–95% RH) |
| Chamber Capacity | 250 L |
| External Dimensions (W×D×H) | 580 × 500 × 850 mm |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 2500 W |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Accuracy | ±3–5% RH |
| Air Filtration | HEPA-grade filter (≥0.3 µm, 99.998% efficiency) |
| Recovery Time | <8 min to 37 °C, <3 min to 5% CO₂ after 30-sec door opening |
| Continuous Operation | ≥360 hours |
| Lighting | Programmable LED light source (red/blue optional), 0–30,000 lx, 6-level intensity control |
| Control Interface | Full-color capacitive touchscreen |
| Compliance | Designed for GLP-compliant cell culture environments |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 0–60 °C (dark), 10–50 °C (with illumination) |
| Temperature Uniformity | Not specified |
| CO₂ Concentration Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control Range & Accuracy | 50–95% RH, ±3–5% RH |
| Chamber Capacity | 250 L |
| External Dimensions (W×D×H) | 780 × 745 × 1560 mm |
| Heating Method | Air-jacketed |
| Humidification Method | Reservoir-based natural evaporation |
| Illumination Capability | Adjustable white-light LED array (0–20,000 lux) |
| Sterilization Options | Optional 90 °C high-humidity thermal decontamination cycle |
| Control System | Microprocessor-based integrated temperature, CO₂, humidity, and light controller with programmable day/night cycling |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range | 10–50°C (with illumination), 0–60°C (without illumination) |
| Temperature Uniformity | Not specified in technical documentation |
| CO₂ Concentration Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control Range & Accuracy | 50–95% RH, ±3–5% RH |
| Chamber Capacity | 800 L |
| Internal Dimensions (W×D×H) | 965 × 580 × 1430 mm |
| Heating Method | Air-jacketed |
| Humidification | Natural evaporation via integrated water reservoir |
| Optional Features | UV sterilization (ozone-free), 90°C high-humidity sterilization cycle, reversible door hinge, multi-layer stacking capability, programmable light cycles (0–30,000 lx), dual-mode (day/night) and ramp-soak temperature/humidity profiles |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT+5°C to 60°C, ±0.1°C |
| Temperature Uniformity | ±0.2°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control Range & Accuracy | 95% RH ±3% RH |
| Chamber Capacity | 160 L |
| External Dimensions (W×D×H) | 500 × 500 × 650 mm |
| Standard Features | Access Port for Sampling, Independent Over-Temperature Protector, RS485 Communication Interface, Programmable Controller, Micro-Printer Output, Real-Time Humidity Display System, Integrated Pressure-Reducing Valve |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Type | Water-Jacketed CO₂ Incubator |
| CO₂ Sensing | Thermal Conductivity (TC) Sensor |
| Temperature Control Range | RT + 5°C to 60°C |
| Temperature Uniformity | ±0.2°C |
| CO₂ Concentration Control Range | 0–20% vol |
| CO₂ Accuracy | ±0.1% vol |
| Humidity Control Method | Natural Evaporation (95% RH ±3%) |
| Capacity | 50 L – 270 L (ZCQ/ZCW standard models) |
| External Dimensions | 545×465×710 mm – 750×715×1030 mm |
| Standard Configuration | HEPA Air Filter (≥0.3 µm, 99.998% efficiency), Mirror-Finish Stainless Steel Interior, Water Jacket with Low-Water Alarm & Auto Cut-off, Door Heating System, Infrared CO₂ Sensor, 90°C Wet-Heat Sterilization (optional), Ozone-Free UV Lamp |