Reflectance Tester
Filter
Showing all 17 results
| Brand | Advantest |
|---|---|
| Origin | Japan |
| Model | TS9000 |
| Type | TDR/TDT Integrated Measurement System |
| Application Domain | Non-destructive Fault Localization in IC Packages and PCB Interconnects |
| Compliance Context | Supports JEDEC JESD22-B111, IPC-TM-650 2.5.1, and IEEE Std 1149.1 (JTAG) auxiliary diagnostics |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | AUT GPS-200 |
| Signal-to-Noise Ratio | 600:1 |
| Wavelength Accuracy | ±0.3 nm |
| Transmittance Accuracy | <0.5% |
| Repeatability | ±0.4% (450–800 nm) |
| Spectral Range | 380–3000 nm |
| Detector | Hamamatsu linear array CCD |
| Grating | Holographic flat-field concave grating |
| Integrating Sphere Coating | PTFE-based polymer (reflectance >99% @ 400–1500 nm) |
| Brand | D&S |
|---|---|
| Origin | USA |
| Model | SSR-ER |
| Reflectance Repeatability | ±0.003 |
| Reflectance Accuracy | ±0.002 |
| Measurement Cycle Time | 8 s |
| Incident Angle | 20° (near-normal) |
| Detector Configuration | 6-channel filtered photodetectors (UV, Blue, Red, IR, plus dual re-sampling for low-CCT red/IR) |
| Sample Minimum Thickness | 6.4 mm |
| Calibration Standard Traceability | NIST-traceable diffuse and specular reflectance standards |
| Brand | HongKe |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HK-BOS Reflecting Objective |
| Magnification | 15× |
| Numerical Aperture | 0.28 |
| Working Distance | 190 mm |
| Clear Aperture | 120 mm |
| Optical Design | All-Reflective, Achromatic |
| Coating Options | Customizable Broadband Metallic (e.g., Al+MgF₂, Protected Au, or Enhanced Ag) |
| Brand | Labsphere |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | CSTM-RC |
| Wavelength Range | 300–1100 nm |
| Brand | Labsphere |
|---|---|
| Model | FOL-150-S |
| Light Source Type | Quartz-Tungsten-Halogen (QTH) |
| Output Power | 150 W |
| Spectral Range | 350 nm – 1000 nm (QTH core), extended usable range 400 nm – 1600 nm via fiber transmission |
| Fiber Interface | SMA 905 connector |
| Integrated Hot Mirror | Yes |
| Compatibility | Designed for Labsphere integrating spheres (e.g., RSA, UV-VIS-NIR series) |
| Cooling | Forced-air convection |
| Dimensions (H×W×D) | 140 × 220 × 320 mm |
| Weight | 4.8 kg |
| Regulatory Compliance | CE, RoHS, UL-listed power supply |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LCA-XXXXX-XXX |
| Price | Upon Request |
| Wavelength Range | 300–1100 nm |
| Brand | Labsphere |
|---|---|
| Model | LFHH-1000 |
| Origin | Shanghai, China |
| Wavelength Range | 350–1050 nm |
| Spectral Resolution | ~1.5 nm |
| Signal-to-Noise Ratio | 300:1 |
| Detector | Hamamatsu S11639 CCD |
| Pixel Count | 2048 × 1 |
| Wavelength Accuracy | <0.2 nm |
| A/D Conversion | 16-bit |
| Acceptance Angle | 25° |
| Standard Reference Panel | 30 × 30 cm Spectralon® (99% reflectance, NIST-traceable options available) |
| Integration Time | 10–65 ms |
| Power Supply | Internal rechargeable Li-ion battery |
| Dimensions (L×W×H) | 17.5 × 9 × 3.5 cm |
| Weight | 1.0 kg |
| GPS Module | Integrated |
| Fiber Interface | SMA 905 compatible |
| Operating System | Android-based embedded platform |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | RSA-FO-150 Fiber-Optic Single-Beam Integrating Sphere |
| Wavelength Range | 250 nm to 2500 nm |
| Brand | Labsphere |
|---|---|
| Model | RSA-FO-150-800-S |
| Wavelength Range | 360–1000 nm |
| Configuration | Dual-beam reflectance & transmittance measurement system with fiber-optic illumination and spectrometer integration |
| Integral Sphere Type | Dual-beam reflectance & transmittance sphere (150 mm diameter, barium sulfate coating, FO port configuration) |
| Compliance | ASTM E275, ASTM E903, ISO 9050, ISO 13468, ISO 14782, CIE S 014 |
| Brand | Labsphere |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RSA-FO-TW-76 |
| Pricing | Available Upon Request |
| Brand | Labsphere |
|---|---|
| Model | RSA-REF-50-DB |
| Illumination Geometry | 8°/h (8° illumination, hemispherical detection) |
| Sphere Diameter | 50 mm |
| Light Source | Integrated Tungsten-Halogen or Optional LED Module |
| Fiber Optic Interface | SMA 905 |
| Compliance | ISO/CIE Compliant Optical Design |
| Origin | Shanghai, China |
| Distribution Status | Authorized Distributor |
| Brand | Photonic Lattice |
|---|---|
| Origin | Japan |
| Model | KAMAKIRI |
| Wavelength | 520 nm |
| Birefringence Range | 0–130 nm (standard), 0–260 nm (optional) |
| Fast Axis Orientation Range | 0–180° |
| Repeatability | <1 nm (σ) |
| Measurement Width | 350 mm |
| Spatial Resolution (Width Direction) | 2560 points |
| Output Parameters | Retardation [nm], Fast Axis Angle [°] |
| Brand | Rhopoint |
|---|---|
| Origin | United Kingdom |
| Model | Novo-Shade Duo+ |
| Reflectance Repeatability | 0.2% |
| Reflectance Accuracy | ±0.1 |
| Measurement Geometry | 0°/45° |
| Display | Full-color LCD with adjustable brightness |
| Interface | 6 capacitive touch keys |
| Construction | Anodized aluminum housing, tempered glass front panel, integrated calibration stand with position detection |
| Data Storage | 8 MB (up to 999 readings), user-definable batch names |
| Connectivity | Bluetooth 4.2, USB Type-A (driver-free PC connection) |
| Battery | Rechargeable Li-ion, ≥17 hours continuous operation, ≥20,000 measurements per charge, 4-hour full recharge |
| Operating Environment | 15–40 °C, ≤85% RH non-condensing |
| Dimensions | 65 mm (H) × 140 mm (L) × 50 mm (W) |
| Weight | 790 g |
| Compliance | ISO 2814, ISO 6504, BS 3900-D4 & D7, ASTM E97, E1347, D4214, D2805, D589 |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | 410 DHR |
| Wavelength Bands | 0.9–1.1, 1.9–2.4, 3.0–4.0, 3.0–5.0, 4.0–5.0, 8.0–12.0 µm |
| Wavelength Resolution | Fixed-band spectral filtering (no scanning monochromator) |
| Measurement Time | 10 s per acquisition (after 90 s warm-up) |
| DHR Repeatability | ±0.5% absolute reflectance (typical, under controlled ambient conditions) |
| Incident Angles | 20° and 60° from normal |
| Sample Geometry Support | Flat, convex (≥6″ radius), concave (≥12″ radius) |
| IR Source | Kanthal® alloy resistive emitter |
| Probe Design | Modular, swappable optical heads |
| Display | Integrated touchscreen PDA with embedded control firmware |
| Operating Temperature | 0–40 °C (non-condensing) |
| Storage Temperature | −25–70 °C |
| Power | Dual rechargeable NiMH batteries |
| Weight | 2.1 kg (including batteries) |
| Calibration | NIST-traceable gold mirror reference standard included |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | 410 Solar |
| Wavelength Range | 335–2500 nm |
| Wavelength Bands | 7 discrete bands (335–380, 400–540, 480–600, 590–720, 700–1100, 1000–1700, 1700–2500 nm) |
| Incident Angle | 20° from normal |
| Measurement Modes | Total reflectance, diffuse reflectance, and 20° specular reflectance |
| Repeatability | ±0.5% (within 10 s per measurement |
| Calibration Traceability | NIST-traceable gold reference standard included |
| Compliance | ASTM E903, ASTM C1549 |
| Spot Size | 0.250" diameter at 20° incidence |
| Beam Divergence | 3° half-angle |
| Operating Temperature | 0–40 °C (non-condensing) |
| Storage | −25 to 70 °C |
| Power | Dual rechargeable NiMH batteries |
| Weight | 2.1 kg (with batteries) |
| Display | Integrated PDA-style touchscreen interface with on-board SD card data storage |
| Brand | TOP-UNISTAR |
|---|---|
| Origin | Hong Kong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | ultraLYZE VUV |
| Pricing | Upon Request |
| Wavelength Range | 115–350 nm |
| Measurement Modes | Transmittance (T), Reflectance (R) |
| Accuracy (R/T) | < 0.3% |
| Wavelength Resolution | < 0.1 nm |
| Operating Environment | High Vacuum (<10⁻⁶ mbar) or N₂ Purge |
| Detector | Angle-Adjustable PMT with Reference Channel |
| Optional Modules | Polarizer, Micro-Focusing Optics, Automated Sample Transfer System |