Cell Analysis
Filter
Showing 1–30 of 142 results
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuLift |
| Pricing | Upon Request |
| Separation Method | Automated |
| Microscope Platform | Olympus IX73 or Nikon Ti2 base |
| IR Capture Laser | 808 nm solid-state, adjustable power |
| UV Cutting Laser | 355 nm & 349 nm diode-pumped Q-switched solid-state, tunable current & pulse frequency |
| Illumination | 5W 24-LED ring light |
| Objectives | Olympus PLAPON/PLANAPO 2×, 4×, 10×, 20×, 40×, 60×, 100× (dry) |
| Stage | Motorized X/Y stage with 0.25 µm homing accuracy & bidirectional repeatability |
| Camera | Dual 5 MP CMOS (color & monochrome), 75 fps at full resolution, large FOV, low-noise |
| Contrast Mode | Brightfield |
| Software Interface | Proprietary LCM control suite with intuitive GUI |
| Brand | Advanced Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | VIPS® PRO |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies (BioTek Division) |
| Product Type | Imported Instrument |
| Model | AutoScratch |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | BioSpa 8 |
| Temperature Control | Up to 45 °C |
| Humidity Control | 80–95% RH |
| CO₂/O₂ Control | Yes |
| Microplate Capacity | 8 plates |
| Compatible Vessel Formats | 6–1536-well microplates, cell culture dishes |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Cytation 5 |
| Temperature Control Range | Up to 45 °C (Incubation) |
| Imaging Magnification | 1.25× to 60× (Air Objectives), 4× to 40× (Phase Contrast) |
| Microscope Type | Inverted |
| Camera | Sony CMOS, 16-bit color |
| Supported Vessels | 6–1536-well plates, slides, Petri dishes, T25 flasks, hemocytometers, chambered coverslips, Take3/Take3 Trio microplates |
| Environmental Control | Quad-zone temperature control (up to 65 °C), condensation management, CO₂/O₂ regulation, Peltier cooling |
| Detection Modes | UV-Vis absorbance, fluorescence intensity (filter & monochromator), luminescence, time-resolved fluorescence (TRF), TR-FRET, AlphaScreen/AlphaLISA, BRET, fluorescence polarization (FP) |
| Monochromator | Quad-grating system with tunable bandwidth |
| Automation Compatibility | BioSpa 8, BioStack, BenchCel, third-party robotic handlers |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Cytation 7 |
| Temperature Control Range | Up to 45 °C |
| Throughput | High-speed automated imaging and detection |
| Cooling Option | Optional Peltier-based cooling module |
| Environmental Control | Integrated gas control (CO₂/O₂) capability |
| Automation Interface | Compatible with robotic liquid handlers and stackers |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Cytation C10 |
| Temperature Control Range | Up to 45 °C |
| Environmental Control | Dual-gas (CO₂/O₂) regulation with condensation prevention |
| Imaging Modalities | Confocal fluorescence, widefield fluorescence, brightfield, phase contrast, high-contrast brightfield, color brightfield |
| Camera | Hamamatsu ORCA-Fusion BT sCMOS (16-bit), Sony IMX series CMOS (16-bit) |
| Objective Compatibility | Olympus air objectives (1.25×–60×), phase contrast (4×–40×), water immersion (20×–60×) |
| Plate Support | 6–1536-well microplates, slides, Petri dishes, T25 flasks, chambered coverslips, hemocytometers, Take3/Take3 Trio microvolume plates |
| Z-stack capability | Motorized focus with DSD (Deep Slice Disk) 60 µm pinhole option |
| Excitation Source | Tunable quad-grating monochromator (UV–Vis), laser-based confocal illumination |
| Automation Integration | BioSpa 8 incubator, BioStack stacker |
| Software Platform | Gen5 Image+ data acquisition and analysis suite |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Lionheart LX |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | NovoCyte Penteon |
| Product Category | Flow Cytometry Analyzer |
| Intended Use | Research-Only |
| Lasers | UV (355 nm), Violet (405 nm), Blue (488 nm), Yellow (561 nm), Red (640 nm) |
| Automated Sample Loading | Yes (integrated Agilent NovoSampler Q) |
| Fluorescence Detection Channels | 30 |
| Detector Technology | Silicon Photomultiplier (SiPM) |
| Scatter Resolution Limit | ≥0.1 µm particles |
| Software Platform | Agilent NovoExpress v4.x |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Seahorse XF Flex |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Seahorse XF Pro |
| Dimensions (W × D × H) | 38.74 cm × 45.72 cm × 58.42 cm |
| Sample Temperature Range | 16–42 °C |
| Operating Ambient Temperature | 4–30 °C |
| Relative Humidity | 20–80 % RH |
| Cell Seeding Density | 5,000–250,000 cells/well |
| Detection Wells | 92 per assay plate |
| Assay Volume per Well | 160–300 µL |
| Power Supply | 100–240 VAC, 9 A, 50/60 Hz |
| Controller OS | Windows 10 Enterprise (64-bit) |
| Memory | 16 GB |
| Connectivity | TCP/IP, USB, Wi-Fi |
| Weight | 22.2 kg |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Life Science Consumables |
| Model | XFe24 Consumables |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Seahorse XFe24 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | XFp Consumables |
| Product Category | Cell Analysis Systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | RTCA DP (3 × 16) |
| Pricing | Available upon request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | RTCA SP (1 × 96-well E-Plate) |
| Pricing | Available upon Request |
| Brand | Akoya |
|---|---|
| Origin | USA |
| Model | PhenoCycler-Fusion |
| Detection Modality | Cyclic Immunofluorescence (CyCIF) + In Situ Hybridization (ISH)-compatible |
| Pixel Resolution | 0.25 µm/pixel |
| Throughput | 5–100 tissue sections per week |
| Multiplex Capacity | >100 protein biomarkers per run |
| Imaging Speed | ~1 million cells imaged in ≤10 minutes |
| Compatible Analytes | Proteins and RNA in formalin-fixed paraffin-embedded (FFPE) and frozen tissue sections |
| Brand | Akoya |
|---|---|
| Origin | USA |
| Model | PhenoImager HT |
| Imaging Modes | Brightfield & Multispectral Fluorescence |
| Max Multiplexing | 9-plex fluorescence |
| Scan Speed | ~6 minutes per full-tissue section (7-color, 20× equivalent) |
| Objective Magnifications | 10×–40× |
| Autofocus | High-sensitivity dynamic autofocus |
| Excitation | Pulsed LED-based fluorescence excitation |
| Primary Application | Spatially resolved quantitative tissue biomarker analysis |
| Brand | Akoya |
|---|---|
| Origin | USA |
| Model | PhenoImager Fusion |
| Imaging Speed | Full-slide 7-color scan in ≤18 minutes |
| Spectral Range | 440–780 nm (tunable liquid crystal filter) |
| Objective Magnifications | 10×, 20×, 40× |
| Throughput | Up to 4 slides per automated run |
| Detection Modes | Multispectral fluorescence, brightfield RGB, conventional epi-fluorescence, optical density (OD)-based quantification |
| Compatibility | PhenoCycler™ integration (≥100-plex workflows), TMA analysis, .QPTIFF output |
| Regulatory Compliance | FDA 21 CFR Part 11–compliant image storage and audit trail |
| Brand | Akoya |
|---|---|
| Origin | USA |
| Model | Vectra 3 |
| Price Range | USD $420,000 – $700,000 |
| Application Domain | Multiplex Immunofluorescence (mIF) and Hematoxylin & Eosin (H&E) Digital Pathology |
| Imaging Modality | High-Resolution Multispectral Fluorescence Microscopy |
| Throughput | Up to 6 Tissue Sections per Run |
| Software Platform | inForm Advanced Image Analysis Suite |
| Brand | Akoya |
|---|---|
| Origin | USA |
| Model | Vectra Polaris |
| Imaging Modes | Brightfield & Multispectral Fluorescence |
| Max Multiplexing | 9-Color Fluorescence |
| Scan Speed | Full-slide 7-color fluorescence scan in ≤6 minutes (at 20× objective) |
| Objective Magnifications | 10×, 20×, 40× |
| Autofocus | High-sensitivity adaptive autofocus with Z-stack optimization |
| Excitation | Pulsed LED-based fluorescence excitation |
| Spectral Resolution | <5 nm FWHM |
| Pixel Size (at 20×) | 0.25 µm/pixel |
| Field of View | 1.3 mm × 1.0 mm per frame (20×) |
| Data Output Format | .qptiff (Quantitative Pathology TIFF), .czi, .ome.tiff |
| Software Platform | inForm Advanced Image Analysis Suite v2.7+ |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Leap-Count 100 / Leap-Count 100A |
| Measurement Principle | Brightfield optical imaging with AI-powered image segmentation |
| Cell Diameter Range | 3–60 µm |
| Cell Concentration Range | 1×10⁴–1×10⁹ cells/mL |
| Optimal Concentration Range | 1×10⁵–1×10⁷ cells/mL |
| Viability Detection Range | 0–100% |
| Sample Volume per Chamber | 10 µL |
| Analysis Time (Leap-Count 100) | ≤8 s |
| Analysis Time (Leap-Count 100A) | ≤2 s |
| Imaging Sensor | 6 MP CMOS |
| Objective Magnification | 3× |
| Repeatability (CV) | <5% |
| Storage Capacity | 1 TB (Leap-Count 100), External PC only (Leap-Count 100A) |
| Display | 10.1″ LCD, 1920×1200 (Leap-Count 100), None (Leap-Count 100A) |
| Data Export Formats | PDF, XLS, TIFF, PNG, JPG |
| Operating System | Windows 10 or later |
| Interface | USB 3.2 Gen 2 ×2 + Ethernet (Leap-Count 100) |
| Dimensions (W×D×H) | 260×268×246 mm (flat) / 260×268×376 mm (vertical) (Leap-Count 100) |
| Weight | 6.5 kg (Leap-Count 100), 5.0 kg (Leap-Count 100A) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Amnis |
|---|---|
| Origin | USA |
| Manufacturer | Luminex Corporation (acquired Amnis) |
| Product Type | Imaging Flow Cytometer |
| Model | ImageStreamX Mark II |
| Laser Configuration | Up to 7 lasers (standard: 488 nm, 642 nm, 785 nm |
| optional | 375 nm, 405 nm, 561 nm, 592 nm) |
| Detection Channels | Standard: 6 channels (1 brightfield, 1 darkfield, up to 4 fluorescence) |
| Objective Lenses | Standard 40× |
| Fluorescence Sensitivity | <5 MESF (Molecules of Equivalent Soluble Fluorochrome) |
| Imaging Rate | >1,000 cells/sec |
| Images per Cell | Up to 12 simultaneous high-resolution digital images (including BF, DF, and multiple fluorescence channels) |
| Pixel Resolution | 656 × 494 pixels per image |
| Field of View | ~100 µm × 75 µm per image |
| Sample Volume Range | 20–200 µL per acquisition |
| Brand | ANGLE |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Parsortix PR1 |
| Pricing | Available Upon Request |
| Separation Method | Fully Automated Microfluidic-Based Capture |
| Brand | Anvajo |
|---|---|
| Origin | Germany |
| Model | Fluidlab R-300 |
| Detection Time | ≤20 s (cell counting) |
| Cell Concentration Range | 1×10⁴–2×10⁷ cells/mL |
| Sample Volume | <20 µL |
| Sample Throughput | 3–80 µL |
| Wavelength Range | 375–700 nm |
| Weight | 240 g |
| Sterilization Method | Alcohol-wipe compatible surface |
| Brand | Anvajo |
|---|---|
| Origin | USA (Designed in Germany, Assembled/Qualified in USA) |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | fluidlab R-300 |
| Pricing | Available Upon Request |
| Brand | Applitech |
|---|---|
| Model | Countleader FL 100 |
| Detection Principle | Digital Imaging Cytometry with Dual-Channel Fluorescence (470/525 nm & 535/617 nm) |
| Sample Volume | 15 µL per well |
| Throughput | Up to 8 samples simultaneously |
| Analysis Modes | Brightfield, Trypan Blue Exclusion, AO/PI Dual-Fluorescence, GFP/RFP Transfection Efficiency |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Consumable | Proprietary FL8-slide (8-well, single-use) |
| Software | Integrated image analysis platform with audit trail, electronic signature, and 3Q validation support |
| Data Output | PDF, Excel, TIFF |
| User Management | Three-tier role-based access control (Administrator, Operator, Viewer) |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Countleader FL 1000 |
| Pricing | Upon Request |
| Brand | Applitech |
|---|---|
| Origin | Germany |
| Manufacturer | Cytena GmbH (distributed by Applitech) |
| Product Type | Imported |
| Model | F.SIGHT 2.0 |
| Pricing | Upon Request |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Co., Ltd. |
| Type | Imported Instrument |
| Model | AS ONE Cell Picking System |
| Separation Method | Fully Automated Microfluidic Single-Cell Isolation |
| Cell Viability | 60–90% |
| Chip Format | Array of >100,000 Microwells (Ø ≈ 10 µm) |
| Detection Mode | Fluorescence Intensity + Brightfield Imaging |
| Recovery Mechanism | Glass Capillary-Based Contact-Free Aspiration |