Particle/Powder Analysis Instruments
Filter
Showing 1–30 of 969 results
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 59986-30 |
| Sieve Capacity | 8 full-height or 16 half-height 20 cm diameter sieves |
| Drive Type | Electromagnetic 3D orbital motion |
| Control | Digital timer with interval pause function and digital amplitude control |
| Compliance | Supplied with NIST-traceable calibration certificate |
| Interface | RS-232 serial output |
| Accessories | Lid and sieves sold separately |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Acona 7000 APS |
| Instrument Type | Optical Single-Particle Counter |
| Detection Principle | SPOS (Single Particle Optical Sensing) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024-channel binning) |
| Sensitivity | 10 ppt (particles per trillion) |
| Dilution Capability | Auto-dilution up to 10¹¹ #/mL original concentration |
| Regulatory Compliance | FDA 21 CFR Part 11, USP <729>, Chinese Pharmacopoeia 2020 Edition |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | A7000 AD |
| Instrument Type | Optical Particle Counter (Single-Particle Optical Sizing, SPOS) |
| Detection Principle | Combined Extinction + Light Scattering |
| Dynamic Range | 0.5–400 µm |
| Resolution | 1024 channels, down to 0.01 µm bin width |
| Sensitivity | ≤10 ppt (particles per trillion) for large particle counting (LPC) |
| Compliance | FDA 21 CFR Part 11, cGMP/GLP-ready |
| Software | Embedded audit-trail-enabled control suite with role-based access, electronic signature, and LIMS integration capability |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Acona A7000 APS |
| Instrument Type | Optical Particle Counter (Light Obscuration / SPOS) |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5–400 µm |
| Resolution | 1024 channels, down to 0.01 µm bin width |
| Sensitivity | ≤10 ppt (particles per trillion) for ≥0.8 µm |
| Max Sample Concentration | 10¹¹ particles/mL (with integrated two-step auto-dilution) |
| Regulatory Compliance | 21 CFR Part 11, USP <729>, Chinese Pharmacopoeia 2020 Edition |
| Software | Audit-trail enabled, role-based access control, electronic signature, LIMS-compatible |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Acona A7000AD |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm |
| Channel Count | 1024 |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | FDA 21 CFR Part 11, cGMP, GLP |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | A7000APS |
| Instrument Type | Optical Particle Counter (SPOS-based) |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024 channels) |
| Sensitivity | 10 ppt (particles per trillion) |
| Max Sample Concentration | 10¹¹ #/mL |
| Compliance | 21 CFR Part 11, USP <729>, ChP 2020 |
| Dilution System | Patented Two-Step Automatic Dilution Module |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Acona A7000SIS |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single Particle Optical Sizing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5–400 µm |
| Minimum Sample Volume | 50 µL |
| Resolution | 0.01 µm |
| Data Channels | 1024 |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | USP <787>, USP <729>, 21 CFR Part 11, cGMP/GLP |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | Acona 7000 SIS |
| Instrument Type | Optical Particle Counter (SPOS-based) |
| Detection Principle | Dual-mode Extinction + Light Scattering |
| Dynamic Range | 0.5–400 µm |
| Minimum Sample Volume | 50 µL |
| Channel Resolution | 1024 channels |
| Size Resolution | 0.01 µm |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | USP <787>, USP <729>, 21 CFR Part 11, cGMP/GLP |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Acona7000APS |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single-Particle Optical Sensing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024-channel binning) |
| Sensitivity | 10 ppt (particles ≥ 0.8 µm) |
| Max Sample Concentration | 10¹¹ #/mL (with patented two-step auto-dilution) |
| Regulatory Compliance | USP <729>, CP 2020 Vol IV, 21 CFR Part 11, cGMP/GLP-ready |
| Brand | Colloidal Dynamics |
|---|---|
| Origin | USA |
| Model | AcoustoSizer II |
| Particle Size Range | 10 nm – 100 µm |
| Zeta Potential Range | 0.5 nm – 30 µm |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.1 °C |
| Ultrasonic Frequency Range | 1–20 MHz |
| Measurement Principle | Multi-frequency electroacoustic spectroscopy & ultrasonic attenuation spectroscopy |
| Sample Concentration Range | 0.1–40% v/v |
| Standard Sample Volume | 85 mL (optional 20 mL) |
| Measurement Time | Real-time, sub-second spectral acquisition per parameter |
| Brand | Advantech |
|---|---|
| Origin | USA |
| Model | L3P-25 |
| Operating Temperature | −18 °C to 49 °C |
| Operating Humidity | Non-condensing |
| Timer Accuracy | ±2 s per 24 h |
| Dimensions | 25 cm × 31 cm × 61 cm |
| Weight | 20 kg |
| Power Supply | 240 VAC, 50 Hz |
| Sieve Diameter | 76.2 mm (3″) |
| Particle Separation Range | 3 µm to 5.6 mm |
| Max. Sieves per Run | 6 standard airflow sieves or 3 precision sieves |
| Vibration Frequency | 60 Hz vertical oscillatory air column |
| Compliance | ASTM E11 certified sieves with full traceability |
| Brand | Advantech |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | L3P-25 |
| Price | Upon Request |
| Sieve Compatibility | 3-inch (76 mm) diameter |
| Timer Accuracy | ±2 sec per 24 hr |
| Processing Efficiency | >90% in ≤10 sec |
| Max Sieve Capacity | 6 standard sieves or 3 precision electroformed sieves |
| Particle Size Range | 3 µm – 5.6 mm |
| Standard Sieve Compliance | ASTM E11, ISO 3310-1 |
| Precision Sieve Material | Electroplated Nickel |
| Precision Sieve Compliance | ASTM E161, ISO 3310-2 |
| Vibration Frequency | 60 Hz |
| Operating Temperature | −18 °C to +49 °C (0 °F to 120 °F) |
| Non-Condensing Humidity Tolerance | Full Range |
| Storage Temperature Limit | −43 °C to +52 °C (−45 °F to +125 °F) |
| Dimensions (W×H×D) | 25 × 31 × 61 cm |
| Weight | 20 kg |
| Power Supply | 240 VAC, 50 Hz |
| Optional Accessory | L3-N8 Horizontal Pulse Generator (disaggregates clusters <45 µm) |
| Traceability | Serialized test sieves with batch-specific calibration metadata per ISO/IEC 17025-aligned QA system |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AccuSizer 780/SIS |
| Dispersion Method | Dry & Wet Dispersion |
| Standard Measurement Range | 0.5–400 µm |
| Optional Ranges | 1–400 µm |
| Channel Count | 32–512 |
| Syringe Volumes | 0.5, 1, 10, 25, 50 mL (user-selectable) |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | CGS-3 MD |
| Laser Wavelength Options | 660 nm (50 mW DPSS) or 532 nm (50 mW Nd:YAG) |
| Detector Configuration | 4 or 8 parallel APD/PMT detectors |
| Angular Spacing | 16° between adjacent detectors (8-detector mode) |
| Correlator | One or two ALV-7004 multi-tau digital autocorrelators (supporting 4- or 8-channel operation) |
| Application Focus | Time-resolved static and dynamic light scattering (SLS/DLS) of rapidly evolving colloidal, polymeric, and biomolecular systems |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | ALV-CorrTector-II |
| Detector Type | Integrated Avalanche Photodiode (APD) with Multi-τ Digital Correlator |
| Count Rate | >80 Mcps |
| Dark Count Rate | ~250 cps |
| Afterpulsing | Minimized with Embedded Correction Algorithm |
| Peak Quantum Efficiency | 60% |
| QE at 488 nm | 53% |
| QE at 532 nm | 40% |
| Operating Temperature Range | 15–35 °C |
| Dimensions | 120 × 58 × 30 mm |
| Weight | 250 g |
| Interface | Mini-USB 2.0 |
| OS Compatibility | Windows 10 (64-bit) |
| Power Consumption | <2 W |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | ALV/CGS-3 |
| Laser Source | 50 mW DPSS, 660 nm |
| Angular Range | 12°–152° |
| Angular Resolution | ±0.025° |
| Angular Accuracy | 0.003° at 25.000° |
| Detector | Dual APD (QE >65% @ 660 nm) |
| Correlation Method | Heterodyne quasi-cross-correlation & auto-correlation |
| Sample Cell | 85 mm OD quartz, centering ≤±5 µm, orthogonality ≤±10 µm, AR-coated 0°/180° windows |
| Temperature Control | Up to 70°C standard |
| Sample Volume Options | Standard cuvette + 5 mm NMR tube adapter |
| Attenuation | 8-step motorized optical density selection |
| Safety Class | EN 60825-1:2014 Class 1 (operational) |
| Compliance | GLP-ready architecture, audit-trail-capable software framework |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Manufacturer | FRITSCH GmbH |
| Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–2000 µm |
| Repeatability | <0.5% |
| Measurement Time | 5–10 s (per single measurement) |
| Dispersion Method | Dry & Wet |
| Optical Design | Inverse Fourier Configuration with Movable Detector Module |
| Laser Sources | 532 nm (green) and 940 nm (infrared) |
| Detection Channels | 108 |
| Sample Loop Volume | 300–500 mL (software-selectable) |
| Ultrasonic Probe | Adjustable Power & Frequency |
| Compliance | ISO 13320:2020 |
| Software | FRITSCH MaS v5.x (compliant with FDA 21 CFR Part 11 audit trail requirements) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Litesizer |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Accuracy | ±0.2 °C |
| Sample Concentration Range | 0.1 mg/L – 100 mg/L |
| Sample Volume Range | 12 µL – 1000 µL |
| Zeta Potential Range | −500 mV to +500 mV |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Litesizer DIA Series |
| Pricing | Upon Request |
| Dispersion Methods | Wet, Dry, and Free-Fall Dispersion |
| Instrument Type | Laboratory-Based Dynamic Image Analyzer |
| Measurement Range | 0.5 µm to 16,000 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–15 seconds per analysis |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Litesizer DIA Series |
| Measurement Principle | Dynamic Image Analysis (DIA) |
| Measurement Range | 0.5 µm to 16,000 µm (dependent on dispersion mode and magnification) |
| Camera Resolution | 5 MPix (2448 × 2048 pixels) with pixel sizes of 0.5 µm / 0.8 µm / 10 µm (model-dependent) |
| Dispersion Modes | Wet dispersion (liquid carrier + optional ultrasonication), dry dispersion (compressed air jet), free-fall dispersion (gravity-driven) |
| Shape & Size Parameters | Feret min/max, projected area-equivalent diameter, length, geodesic length (for fibers), Legendre ellipse major/minor axes, aspect ratio, ellipticity, irregularity, elongation, circularity, shape factor, compactness, convexity, solidity — all compliant with ISO 9276-6:2023 |
| Data Acquisition Rate | Up to 220 fps (Litesizer DIA 700, 5 MPix) |
| Optical Magnification | 0.3×, 1×, and 6× (DIA 700) |
| Interface | 1 × 10 GbE, 1 × USB-A 3.0 |
| Dimensions (H×W×D) | 400 mm × 790 mm × 290 mm |
| Weight | 41 kg |
| Power Supply | 100–240 V ±10%, 50/60 Hz |
| Compressed Air | 5–10 bar (72–145 psi) |
| Liquid Supply Pressure | ≤8 bar (116 psi) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 0.01–3500 µm (DIF 500) / 0.1–2500 µm (DIF 300) / 0.1–1000 µm (DIF 100) |
| Repeatability | Better than ±0.5% RSD |
| Measurement Time | <10 s |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Litesizer DIF |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | < 10 s |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DIF500 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | < 10 s |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | Litesizer DLS 101 |
| Particle Size Range | 0.3 nm – 12 µm |
| Size Measurement Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz (658 nm diode laser) |
| Measurement Principle | Dynamic Light Scattering (DLS) |
| Sample Concentration Range | up to 50% w/v |
| Minimum Sample Volume | 1.5 µL |
| Zeta Potential Range | –500 mV to +500 mV |
| Typical Measurement Time | <1 min |
| Molecular Weight Range | 1 kDa – 20 MDa |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | Litesizer DLS 501 |
| Zeta Potential Range | ±1000 mV |
| pH Range | 2–12 |
| Temperature Range | 0–120 °C |
| pH Resolution | 0.01 |
| Temperature Resolution | 0.01 |
| Accuracy | ±3% (Zeta), ±2% (DLS), ±10% (Molecular Weight) |
| Repeatability | ±3% (Zeta), ±2% (DLS), ±5% (Molecular Weight) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | Litesizer DLS |
| Particle Size Range | 0.3 nm – 15 µm (diameter) / 0.3 nm – 10 µm (diameter) |
| Size Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz |
| Size Measurement Principle | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS) |
| Zeta Potential Range | ±1000 mV |
| Zeta Potential Reproducibility | ±3% |
| Molecular Weight Range | 300 Da – 20 MDa |
| Sample Volume | 1.5 µL – 1 mL |
| Concentration Range | up to 50% w/v |
| Measurement Time | <1 min |
| Transmission Monitoring | Real-time, 0–100% |
| Refractive Index Measurement Accuracy | ±0.5% (range: 1.28–1.50) |
| Optical Configurations | Fluorescence & polarization filters (15°, 90°, 175°) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Litesizer DLS 101 / 501 / 701 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Sizing System |
| Measurement Range | 0.3 nm – 12 μm (particle diameter) |
| Repeatability | ±2% |
| Measurement Time | < 60 s |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Litesizer DLS Series |
| Particle Size Range | 0.3 nm – 15 µm (DLS, DLS 701) |
| Size Reproducibility | ±2% |
| Temperature Control Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Laser Frequency | 455 THz (658 nm diode laser) |
| Particle Sizing Method | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS) |
| Sample Volume | 1.5 µL – 1 mL |
| Sample Concentration | up to 50% w/v |
| Zeta Potential Range | ±1000 mV |
| Measurement Time | < 60 s |
| Molecular Weight Range | 300 Da – 20 MDa |
| Zeta Potential Reproducibility | ±3% |
| Refractive Index Accuracy | ±0.5% (for DLS 701/501) |
| Transmission Monitoring | 0–100%, resolution <1% |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MCR Powder Rheometer |
| Instrument Type | Multifunctional Powder Flowability Tester |
| Minimum Sample Volume | 4.3 mL / 18.9 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SurPASS 3 |
| Measurement Principle | Streaming Potential Method |
| pH Range | pH 2 – pH 12 |
| Temperature Range | 20 °C to 40 °C |
| Temperature Control | Integrated Peltier-based thermostating |
| Sample Compatibility | Flat solids (min. 20 mm × 10 mm, ≤2 mm thick |