Densitometer
Filter
Showing 1–30 of 210 results
| Brand | A.Krüss / A.Krüss Optronic |
|---|---|
| Origin | Germany |
| Model | DS7800 |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0.0000–1.9999 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Control Range | 10–40 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D4052-18, ASTM D5002, ISO 12185:1996, ISO 2811-3:2011, SH/T 0604-2000, GB/T 21862.3-2008 |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EJ-120D |
| Weighing Capacity | 120 g |
| Readability | 0.01 g |
| Density Resolution | 0.01 g/cm³ |
| Repeatability | 0.01 g |
| Pan Size | 110 mm |
| Display | Backlit LCD, 16 mm digit height |
| Interface Options | RS-232 or driver-free USB |
| Power Supply | AC adapter and rechargeable battery dual mode |
| Compliance | GLP/GMP/GCP and ISO-compliant calibration reporting |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / EK-3000iD |
| Instrument Type | Benchtop Solid Density Analyzer |
| Measurement Principle | Archimedean Buoyancy Method (Air Weight / (Air Weight − Immersed Weight) × Reference Liquid Density) |
| Density Range | 0–2.000 g/cm³ |
| Density Resolution | 0.001 g/cm³ (EK-300iD) / 0.01 g/cm³ (EK-3000iD) |
| Temperature Range | 0–100 °C |
| Minimum Sample Mass | 0.001 g |
| Reference Liquids | Water, Kerosene, or User-Defined Liquids (Density Input Range: 0.000–2.000 g/cm³) |
| Temperature Compensation | Automatic |
| Data Storage | 200 Records |
| Interface | RS-232 |
| Compliance | GLP/GMP/GCP Audit Trail Ready, ISO/IEC 17025 Support Enabled |
| Software | WinCT Data Acquisition Suite (Windows-compatible, Excel export, statistical analysis, graphing) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / GF-300D |
| Instrument Type | Buoyancy-Based Density Balance |
| Measurement Principle | Archimedes’ Principle |
| Weighing Capacity | 300 g (EK-300iD), 310 g (GF-300D) |
| Weighing Readability | 0.01 g (EK-300iD), 0.001 g (GF-300D) |
| Density Resolution | 0.001 g/cm³ |
| Display | Backlit LCD (16 mm character height, EK-iD series) |
| Stabilization Time | ≤1 s (GF-D series) |
| Internal Resolution | 1/10,000,000 |
| Environmental Response Modes | FAST / MID / SLOW |
| Calibration | Full-digital span calibration with user-adjustable reference weight input |
| Temperature Compensation | Direct water temperature or reference liquid density entry |
| Density Comparison Mode | Hi / OK / Lo alarm output (optional external relay module) |
| Auto Power-Off | Configurable after ≥10 min inactivity |
| Interface | RS-232C standard port |
| Software | WinCT v3.x (Windows-compatible, supports Excel/Office data export, statistical analysis, time-series logging, and chart-based visualization) |
| Compliance | Built-in GLP/GMP/ISO audit trail functions (date/time stamping, instrument ID, calibration history, operator ID, measurement statistics) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | VBC-1, VBC-2, VBC-3, VBC-4, VBC-1T, VBC-2T, VBC-3T, VBC-4T |
| Temperature Range | −50 °C to 0 °C (VBC-2/3/4/T variants) or −60 °F to 30 °F (VBC-1/VBC-1T) |
| Specific Gravity Range | 1.15–1.30 sg (standard) |
| Resolution | 0.01 sg or 0.01 kg/L |
| Temperature Resolution | 5 °C or 10 °C (model-dependent) |
| Dimensions | 27 × 40 × 160 mm |
| Weight | 176 g (standard), 215 g (T-series with enhanced thermal stability) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ElaTest |
| Density Measurement Range | 0.8–2.6 g/cm³ |
| Temperature Range | 0–40.0 °C |
| Repeatability | ±0.00001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 40–120 cm³ |
| Application | Density of uncured rubber and rubber compounds |
| Instrument Type | Benchtop Laboratory Densitometer |
| Detection Principle | Pneumatic (gas displacement) density measurement |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 1002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ±0.00005 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | 15–60 °C |
| Temperature Stability | ±0.02 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7″ TFT WVGA Touchscreen (800 × 480 px, PCAP) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DMA 1002/1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Category | Portable |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Accuracy | ±0.03 °C (from +15 °C to +100 °C) |
| Density Resolution | 5 significant digits |
| Viscosity Range (DMA 1102 only) | –0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP touch screen |
| Dimensions (L×W×H) | 365 mm × 265 mm × 180 mm |
| Weight | 6.6 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Application | Petroleum Products Density & Kinematic Viscosity Measurement |
| Detection Medium | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Resolution | 5 significant digits |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Stability | ±0.03 °C over full range |
| Viscosity Range | −0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Dimensions (L×W×H) | 365 × 265 × 180 mm |
| Weight | 6.6 kg |
| Power Supply | DC 24 V / 3 A |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DMA 35 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Portable |
| Sample State | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ (for samples with viscosity < 300 mPa·s and density < 2 g/cm³) |
| Temperature Range | 0 °C to 40 °C (32 °F to 104 °F) |
| Repeatability (std. dev.) | ±0.0005 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 2 mL |
| Environmental Rating | IP54 |
| ATEX/IECEx Certification | II 2G Ex ib IIB T4 Gb (DMA 35 Ex & DMA 35 Ex Petrol variants) |
| Compliance | ASTM D7777, IP 559 |
| Connectivity | Bluetooth® 4.2, RFID reader (integrated) |
| Data Storage | Up to 1,200 measurements, 250 sample IDs, 30 user-defined methods |
| Power | 3 × 1.5 V LR06 AA alkaline batteries |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 mm × 103 mm × 126 mm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 4002 / DMA 5002 / DMA 6002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ (DMA 4002), ±0.00001 g/cm³ (DMA 5002, 0–1.05 g/cm³ at 15–20 °C), ±0.000005 g/cm³ (DMA 6002, full range) |
| Temperature Range | 0 °C to 100 °C |
| Temperature Accuracy | ±0.02 °C (DMA 4002), ±0.01 °C (DMA 5002 & DMA 6002, 15–20 °C) |
| Density Repeatability (Std. Dev.) | 0.00001 g/cm³ (DMA 4002), 0.000003 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Density Resolution | 0.00001 g/cm³ (DMA 4002), 0.000005 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Minimum Sample Volume | 1 mL |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Compliance | ASTM D4052, D5002, D1250 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4100 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Range | 0 °C to 100 °C |
| Temperature Accuracy | ±0.03 °C |
| Density Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Measurement Time (after thermal equilibration) | 30 s |
| Repeatability (σ) | 0.00001 g/cm³ |
| Reproducibility (σ) | 0.00005 g/cm³ |
| Operating Pressure | up to 10 bar |
| Display | 10.4" TFT PCAP Touchscreen (640 × 480 px) |
| Interfaces | 4× USB, RS-232, CAN, VGA, Ethernet |
| Data Storage | 1000 measurements (circular buffer optional) |
| Wetted Materials | PTFE, borosilicate glass |
| Dimensions (L×W×H) | 495 × 330 × 230 mm |
| Weight | 22.5 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | 0.0001 g/cm³ (DMA 4100M) / 0.00005 g/cm³ (DMA 4500M) / 0.000005 g/cm³ (DMA 5000M) |
| Temperature Range | 0 °C to 95 °C |
| Temperature Accuracy | ±0.05 °C (4100M) / ±0.03 °C (4500M) / ±0.01 °C (5000M) |
| Minimum Sample Volume | 1 mL |
| Repeatability (Std. Dev.) | 0.00005 g/cm³ (4100M) / 0.00001 g/cm³ (4500M) / 0.000001 g/cm³ (5000M) |
| Display | 10.4" PCAP TFT Touchscreen (640 × 480 px) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP, ISO 12084, ASTM D4052, USP <841> |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4200 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³ (at ambient pressure, ideal conditions) |
| Density Repeatability | ±0.00005 g/cm³ (std. dev., ISO 5725) |
| Density Reproducibility | ±0.0001 g/cm³ (std. dev., ISO 5725) |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | –10 °C to +200 °C (14 °F to 392 °F) |
| Pressure Range | 0–500 bar (0–7250 psi) |
| Minimum Sample Volume | 2 mL |
| Temperature Accuracy | ±0.03 °C |
| Temperature Repeatability | ±0.01 °C |
| Viscosity Correction | Automatic, real-time, pressure- and temperature-compensated |
| Filling Verification | FillingCheck™ (ASTM D4052 / GB/T 29617 / ASTM D5002 compliant) |
| Thermal Equilibration Technology | Temperfect™ (enables immediate density measurement at any temperature from 0 °C to 150 °C under ambient pressure) |
| Excitation Method | Patented Pulsed Excitation Method (AT 516420 B1) |
| Cell Material | Hastelloy® C-276 |
| Dimensions | 510 mm × 330 mm × 380 mm (W × D × H) |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interfaces | 4× USB 2.0, 1× Ethernet (100 Mbit), 1× CAN Bus, 1× RS-232, 1× VGA |
| Wetted Parts | Hastelloy C-276 only |
| Compliance | ASTM D4052, ASTM D5002, GB/T 29617, ISO 12185, ISO 16554 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4200 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquid (including high-viscosity, solid-at-room-temperature, and pressurized samples) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ≤0.00005 g/cm³ (standard deviation) |
| Temperature Range | −10 °C to +200 °C (14 °F to 392 °F) |
| Temperature Accuracy | ±0.03 °C |
| Pressure Range | 0–500 bar (0–7,250 psi) |
| Minimum Sample Volume | 2 mL |
| Measuring Cell Material | Hastelloy C-276 |
| Cell Volume | ~2 mL |
| Dimensions | 510 × 330 × 230 mm (20 × 13 × 8.7 in) |
| Weight | 27.1 kg (59.7 lb) |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interfaces | 4 × USB 2.0, 2 × S-Bus, 1 × Ethernet (100 Mbit), 1 × CAN Bus, 1 × RS-232, 1 × VGA |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 4200M |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³ |
| Density Repeatability (s.d.) | ±0.00005 g/cm³ |
| Digital Resolution | 0.00001 g/cm³ |
| Temperature Range | −10 °C to 200 °C (14 °F to 392 °F) |
| Pressure Range | 0–500 bar (7250 psi) |
| Minimum Sample Volume | 2 mL |
| Viscosity Correction | Fully Automated, Real-Time |
| Filling Verification | FillingCheck™ |
| Thermal Equilibration Technology | Temperfect™ |
| Oscillation Excitation Method | Pulsed Excitation Method (Patent AT 516420 B1) |
| Wetted Materials | Hastelloy C-276 |
| Compliance Standards | ASTM D4052, ASTM D5002, GB/T 29617 |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interface Ports | 4× USB 2.0, 1× Ethernet (100 Mbit), 1× CAN Bus, 1× RS-232, 1× VGA, 1× 1/8″ OD metal pressure fitting |
| Brand | Anton Paar |
|---|---|
| Origin | Japan (manufactured in Austria) |
| Model | DMA 5001 |
| Instrument Type | Laboratory Benchtop Densitometer |
| Sample Type | Solid & Liquid Compatible |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Density Range | 0 to 3 g/cm³ |
| Temperature Range | 0 °C to 100 °C |
| Accuracy (Density) | ±0.000005 g/cm³ |
| Repeatability (Density) | ±0.000001 g/cm³ |
| Minimum Sample Volume | ~1 mL |
| Display | 10.1″ TFT WXGA Touchscreen (1280 × 800 px) |
| Data Storage | >10,000 measurements with embedded camera images |
| Measurement Time | ≤40 s per sample |
| Operating System | Real-time embedded OS (8× faster than previous generation) |
| CPU | Dual-core processor (2× speed increase) |
| Compliant | FDA 21 CFR Part 11, GLP/GMP audit trail, ISO/IEC 17025 traceability support |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 501 |
| Instrument Type | Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquids, Suspensions, Emulsions, Pastes, Aerosols |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 15–40 °C |
| Temperature Accuracy | ±0.3 °C |
| Repeatability (Std. Dev.) | ±0.0002 g/cm³ |
| Reproducibility (Std. Dev.) | ±0.0004 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Viscosity Correction | Full-range automatic |
| Compliance | ISO 5725, ASTM D4052, ISO 12185, USP <841>, GLP/GMP-ready |
| Dimensions (L×W×H) | 375 × 265 × 180 mm |
| Weight | 13.5 kg |
| Display | 7″ TFT WVGA Touchscreen (800 × 480 px) |
| Connectivity | Ethernet, 3× USB, RS232 |
| Data Storage | 5,000 measurements |
| Environmental Monitoring | Integrated temperature/humidity/pressure sensors |
| Optional Accessories | Aerosol adapter, peristaltic pump, paste sampling kit, ISO calibration certificate |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 502 |
| Instrument Type | Oscillating U-tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids and Low-Viscosity Suspensions |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 15–40 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Environmental Compensation | Automatic pressure, altitude, and ambient humidity correction |
| Data Storage | 5000 measurements |
| Method Library | 400 pre-validated methods |
| Conversion Tables | 140 built-in (alcohol, sugar, acids, API gravity, etc.) |
| Compliance | ASTM D4052, ASTM D5002, USP <841>, EP/JP pharmacopoeial density requirements, FDA 21 CFR Part 11 (when used with AP Connect) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids and Semi-solids (with optional kits) |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | 0.001 g/cm³ (DMA 502), 0.0001 g/cm³ (DMA 1002) |
| Density Repeatability | 0.0002 g/cm³ (DMA 502), 0.00005 g/cm³ (DMA 1002) |
| Temperature Range | 5–35 °C (ambient), 15–40 °C (measurement, DMA 502), 15–60 °C (measurement, DMA 1002) |
| Temperature Resolution | 0.01 °C |
| Minimum Sample Volume | ~1 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP capacitive touchscreen |
| Dimensions (L×W×H) | 375 × 280 × 180 mm |
| Weight | 13.5 kg |
| Connectivity | 1× Ethernet, 3× USB, 1× RS232 |
| Data Storage | 5000 measurements, 400 user-defined methods, 140 built-in conversion tables |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 6002 Sound Velocity |
| Instrument Type | Oscillating U-tube Densimeter & Sound Velocity Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Sound Velocity Range | 1000 m/s to 2000 m/s |
| Temperature Range | 0 °C to 100 °C (32 °F to 212 °F) |
| Pressure Range | 0 bar to 8 bar (0 psi to 116 psi) |
| Density Accuracy | ±0.000005 g/cm³ |
| Density Repeatability (Std. Dev.) | ±0.000001 g/cm³ |
| Sound Velocity Repeatability (Std. Dev.) | ±0.1 m/s |
| Density Reproducibility (Std. Dev.) | ±0.000005 g/cm³ |
| Sound Velocity Reproducibility (Std. Dev.) | ±0.5 m/s |
| Density Resolution | 0.000001 g/cm³ |
| Sound Velocity Resolution | 0.01 m/s |
| Minimum Sample Volume | 3.5 mL |
| Measurement Throughput | Up to 30 samples/hour |
| Compliance | ISO 5725, ASTM D4052, ASTM D1250, ISO 12185, ISO 17025 (when operated with certified calibration standards) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HPM |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Phase | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ≤0.00001 g/cm³ (standard deviation) |
| Temperature Range | −10 to +200 °C |
| Pressure Range | 0–1400 bar (0–20,300 psi) |
| Minimum Sample Volume | ~2 mL |
| Cell Material | Hastelloy C-276 |
| Digital Resolution | 0.00001 g/cm³ |
| Interface | 1/4″ metal tubing compression fittings |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | Oscillating U-tube (OUM) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability (std. dev.) | ±0.0005 g/cm³ |
| Temperature Range (Sample) | 0–40 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Repeatability | ±0.1 °C |
| Sample Volume | 1–2 mL |
| Resolution | 0.0001 g/cm³ (density), 0.1 °C (temperature) |
| Environmental Operating Range | −10 to +50 °C (standard) |
| Protection Rating | IP54 |
| ATEX/IECEx Certification | II 2G Ex ib IIB T4 Gb (DMA35 Ex & DMA35 Ex Petrol) |
| Data Storage | 1024 measurements, 30 methods, 250 sample IDs |
| Interface | Bluetooth®, RFID, IrDA |
| Power Supply | 3 × AA alkaline batteries (LR06) |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 × 103 × 126 mm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 |
| Instrument Type | Portable Oscillating Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 0–40 °C (operational range: −10 to +50 °C) |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Density Repeatability | ±0.0005 g/cm³ |
| Minimum Sample Volume | 1–2 mL |
| Viscosity Limit | ≤100 mPa·s (for samples <2 g/cm³) |
| Data Storage Capacity | 1024 measurements |
| Communication Interfaces | IrDA infrared, RFID (Tag&Log version only) |
| Ingress Protection Rating | IP54 |
| Power Supply | 2 × AA alkaline batteries (1.5 V) |
| Dimensions | 140 × 138 × 27 mm |
| Weight | 368 g |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Portable Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0005 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range (Measurement) | 0–40 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Repeatability | ±0.1 °C |
| Minimum Sample Volume | 1–2 mL |
| Operating Ambient Temperature | −10 to +50 °C |
| IP Rating | IP54 |
| Intrinsic Safety Certification | Ex II 2 G Ex ib IIC T4 (Ex and Ex Petrol versions) |
| Data Storage | 1024 measurements, 30 methods, 250 sample IDs |
| Connectivity | Bluetooth® v4.2, RFID reader (integrated) |
| Power Supply | 3 × AA LR06 alkaline batteries (1.5 V) |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 × 103 × 126 mm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 Standard |
| Instrument Type | Oscillating U-tube Density Meter |
| Portability | Portable |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 0 °C to 40 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D7777, IP 559 |
| Explosion Protection | Ex II 2 G Ex ib IIB T4 (DMA35 Ex & DMA35 Ex Petrol variants) |
| Data Storage | Up to 1024 measurements with timestamp and sample ID |
| Connectivity | Bluetooth® v4.2, RFID interface, USB-C for charging/data backup |
| Display | Capacitive touchscreen with auto-rotation and backlighted viewing window |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DMA35N |
| Accuracy | ±0.001 g/cm³ |
| Measurement Range | 0 to 1.999 g/cm³ |
| Temperature Range | 0 to 40 °C (operational), sample temperature up to 100 °C |
| Minimum Sample Volume | 2 mL |
| Weight | 275 g |
| Power Supply | Rechargeable battery |
| Interface Options | RS232 or infrared |
| Data Storage Capacity | 1024 measurements |
| Built-in Concentration Tables | H₂SO₄, Brix, % alcohol (v/v and w/w), API gravity, others |
| Automatic Temperature Compensation | Yes |
| Pump Type | Integrated high-performance micro-pump |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Perfume and Flavor Measurement System |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Temperature Control Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Integrated Parameters | Density, Refractive Index, Optical Rotation, Colorimetry, Turbidity |
| Automation | Fully Automated Sample Handling with Recovery (Xsample 5200/530), Integrated Cleaning & Drying |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Ultrapyc Series |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Solids (bulk & granular), Powders, Pastes, Slurries, Foams |
| Density Accuracy | ≤0.015% |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Temperature Range | 3–60 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Snap 41 |
| Instrument Type | Portable Digital Alcohol Meter |
| Measurement Principle | U-tube Oscillation Density Method |
| Density Range (for Ethanol-Water Solutions) | 0–100 % v/v alcohol |
| Temperature Range (Measurement) | 5–30 °C (41–86 °F) with Automatic Temperature Compensation |
| Accuracy | ±0.2 % v/v alcohol, ±0.2 °C temperature |
| Repeatability (Std. Dev.) | ±0.1 % v/v alcohol, ±0.1 °C |
| Resolution | 0.01 % v/v alcohol, 0.1 °C |
| Sample Volume | 2 mL |
| Operating Ambient Temperature | 0–35 °C (32–95 °F) |
| Display | Digital LCD |
| Environmental Rating | IP54 |
| Power Supply | 3 × 1.5 V LR06 (AA) alkaline batteries |
| Dimensions | 245 × 103 × 126 mm (9.6 × 4.0 × 5.0 in) |
| Weight | 660 g (23.3 oz) |
| Supported Units | % v/v (at 15 °C or 20 °C), Proof, °Brix, °Plato, and 10 programmable custom units |
| Data Storage | 1024 measurements, 250 sample IDs, 30 user-defined methods |
| Connectivity | Bluetooth® (firmware updates only) |
| Compliance | ASTM D1152, ISO 3696, OIML R 22, EN 15733, EU Regulation (EC) No 1234/2007 Annex XI (alcohol determination in spirits) |